Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat conduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Results from the cascaded variable conductance heatpipe experiment on LDEF

A Variable Conductance Heat Pipe Experiment (CVCHPE) was successfully flown onboard the LDEF and demonstrated temperature control better than +/- 0.3 C during 50 days of on-orbit data collection in a widely varying external environment. The experiment used two series connected, dry reservoir variable conductance heat pipes which require no electrical power for operation. The heat pipes used a central artery design with ammonia working fluid and nitrogen control gas.

Grote, Michael G.↗

Results from the LDEF/A0076 cascaded variable conductance heatpipe experiment

The A0076 Variable Conductance Heat Pipe Experiment (CVCHPE) on the Long Duration Exposure Facility (LDEF) demonstrated temperature control better than +/- 0.3 C during fifty days on on-orbit data collection in a widely varying external environment. The experiment used two series connected, dry reservoir variable conductance heat pipes which require no electrical power for operation. The heat pipes used a central artery design with ammonia working fluid and nitrogen control gas. The LDEF was in orbit for almost six years rather than the planned one year mission. Although no additional data were taken during this extended period, post-test data indicated that the set point drifted upward less than 1 C per year. There were significant changes to the appearance of all external thermal control surfaces primarily due to atomic oxygen degradation, and one small anomaly in the electronics. These changes, though, had little effect on the CVCHPE performance.

Grote, Michael G.↗

The effect of gravity waves on the global mean temperature and composition structure of the upper atmosphere

Formulas are presented that parameterize the heating rate and coefficient of turbulent heat conduction produced by saturated internal gravity waves (IGW) in the upper atmosphere. Estimates of these values are made using observational data. The parameterization of IGW influences are introduced into a one-dimensional model of global mean thermal and composition balances of the upper atmosphere. Computations are performed for different values of IGW energy fluxes entering into the upper atmosphere from below. It is shown that realistic vertical profiles of the global mean temperature can be obtained using different values of IGW energy flux into the upper atmosphere. Increasing the IGW intensity leads not only to an increase of the heating rate due to wave enery dissipation, but also to an increase of the heating rate due to wave energy dissipation, but also to an increase in the coefficient of turbulent heat conduction and cooling rate produced by turbulence generated by the wave. So, near an altitude of 100 km the main part of solar heating is compensated by infrared cooling on one hand, and the main part of wave dissipation heating is compensated by turbulent cooling on the other hand. These quasi-balances generally hold for different values of IGW intensity.

Gavrilov, Nikolai M.↗

Improvement in finite element meshes: Heat transfer in an infinite cylinder

An extension of a structural finite element mesh improvement technique to heat conduction analysis is presented. The mesh improvement concept was originally presented by Prager in studying tapered, axially loaded bars. It was further shown that an improved mesh can be obtained by minimizing the trace of the stiffness matrix. These procedures are extended and applied to the analysis of heat conduction in an infinitely long hollow circular cylinder.

Kittur, Madan G.↗

Improvement of finite element meshes - Heat transfer in an infinite cylinder

An extension of a structural finite element mesh improvement technique to heat conduction analysis is presented. The mesh improvement concept was originally presented by Prager in studying tapered, axially loaded bars. It was further shown that an improved mesh can be obtained by minimizing the trace of the stiffnes matrix. These procedures are extended and applied to the analysis of heat conduction in an infinitely long hollow circular cylinder.

Kittur, Madan G.↗

Exercise thermoregulation with bed rest, confinement, and immersion deconditioning

Altered thermoregulation following exposure to prolonged (12-14 days) of bed rest and 6 hr of head-down thermoneutral water immersion in humans, and cage confinement (8 weeks) in male, mongrel dogs resulted in occasional increased core temperature (Tcore) at rest, but consistent "excessive" increase in Tcore during submaximal exercise. This excessive increase in Tcore in nonexercising and exercising subjects was independent of the mode (isometric or isotonic) of exercise training during bed rest, and was associated with the consistent hypovolemia in men but not in women taking estrogen supplementation (1.25 mg premarin/ day) which restored plasma volume during bed rest to ambulatory control levels. Post-bed rest exercise sweating (evaporative heat loss) was unchanged or higher than control levels; however, calculated tissue heat conductance was significantly lower in men, and forearm venoconstriction was greater (venous volume was reduced) in women during exercise after bed rest. Because sweating appeared proportional to the increased level of Tcore, these findings suggest that one major factor for the excessive hyperthermia is decreased core to periphery heat conduction. Exercising dogs respond like humans with excessive increase in both rectal (Tre) and exercising muscle temperatures (Tmu) after confinement and, after eight weeks of exercise training on a treadmill following confinement, they had an attenuated rate of increase of Tre even below ambulatory control levels. Intravenous infusion of glucose also attenuated not only the rise in Tre during exercise in normal dogs, but also the excessive rise in Tre and exercising Tmu after confinement. Oral glucose also appeared to reduce the rate of increase in excessive Tre in men after immersion deconditioning. There was a greater rate of rise in Tcore in two cosmonauts during supine submaximal exercise (65% VO2 max) on the fifth recovery day after the 115-day Mir 18 mission. Thus, the excessive rise in core temperature after deconditioning appears to be caused by decreased peripheral vasodilation in humans. Factors related to glucose metabolism may influence this mechanism.

NASA Program Space Physiology and Countermeasures↗

Towards understanding turbulent scalar mixing

In an effort towards understanding turbulent scalar mixing, we study the effect of molecular mixing, first in isolation and then by accounting for the effects of the velocity field. The chief motivation for this approach stems from the strong resemblance of the scalar probability density function (PDF) obtained from the scalar field evolving from the heat conduction equation that arises in a turbulent velocity field. However, the evolution of the scalar dissipation is different for the two cases. We attempt to account for these differences, which are due to the velocity field, using a Lagrangian frame analysis. After establishing the usefulness of this approach, we use the heat-conduction simulations (HCS), in lieu of the more expensive direct numerical simulations (DNS), to study many of the less understood aspects of turbulent mixing. Comparison between the HCS data and available models are made whenever possible. It is established that the beta PDF characterizes the evolution of the scalar PDF during mixing from all types of non-premixed initial conditions.

Girimaji, Sharath S.↗

Thermal histories of the samples of two KOSI comet nucleus simulation experiments

Temperatures recorded during two KOSI comet nucleus simulation experiments strongly suggest that heat transport by vapor flow into the interior of the sample is very important. Two comet nucleus simulation experiments have been done by the KOSI team in a big space simulator. The thermal evolution of the sample during insolation and the results of simplified thermal evolution calculations are discussed. The observed thermal histories cannot be explained by a simple model with heat transferred by heat conduction at a constant conductivity, so a coupled heat and mass transfer problem was considered. The porous ice matrix was assumed to have a constant thermal conductivity and to be in thermal equilibrium with vapor in the pores, the internal pressure being the vapor pressure. The vapor was modelled as an ideal gas because, at the temperatures relevant to the problem, the mean free path length of the vapor molecules is large in comparison with the pore dimensions. The heat capacity at constant volume per unit mass of the two phase mixture was also assumed constant. The vapor was allowed to flow and transfer heat in response to an internal pressure gradient.

Spohn, T.↗

Thermal Management and Thermal Protection Systems

During my internship in the Thermal Design Branch (ES3), I contributed to two main projects: i) novel passive thermal management system for future human exploration, ii) AVCOAT undercut thermal analysis. i) As NASA prepares to further expand human and robotic presence in space, it is well known that spacecraft architectures will be challenged with unprecedented thermal environments. Future exploration activities will have the need of thermal management systems that can provide higher reliability, mass and power reduction and increased performance. In an effort to start addressing the current technical gaps the NASA Johnson Space Center Passive Thermal Discipline has engaged in technology development activities. One of these activities was done through an in-house Passive Thermal Management System (PTMS) design for a lunar lander. The proposed PTMS, functional in both microgravity and gravity environments, consists of three main components: a heat spreader, a novel hybrid wick Variable Conductance Heat Pipe (VCHP), and a radiator. The aim of this PTMS is to keep electronics on a vehicle within their temperature limits (0 and 50 C for the current design) during all mission phases including multiple lunar day/night cycles. The VCHP was tested to verify its thermal performance. I created a thermal math model using Thermal Desktop (TD) and analyzed it to predict the PTMS performance. After testing, the test data provided a means to correlate the thermal math model. This correlation took into account conduction and convection heat transfer, representing the actual benchtop test. Since this PTMS is proposed for space missions, a vacuum test will be taking place to provide confidence that the system is functional in space environments. Therefore, the model was modified to include a vacuum chamber with a liquid nitrogen shroud while taking into account conduction and radiation heat transfer. Infrared Lamps were modelled and introduced into the model to simulate the sun's rays directly impinging on the system. Heating rate of the lamps were calculated by knowing fraction of emitted energy in a wavelength interval and the filament temperature. This version of the model can be used to predict performance of the system under vacuum with extreme cold or hot conditions. Initial testing of the PTMS showed promise, and the thermal math model predicts even better performance in thermal vacuum testing. ii) Thermal Protection Systems (TPS) are required for vehicles which enter earth's atmosphere to protect from aerodynamic heating caused by the friction between the vehicle and atmospheric gases. Orion's heat shield design has two aspects which needed to be analyzed thermally: i) a small excess of adhesive used to bond the outer AVCOAT layer to the inner composite structure tends to seep from under the AVCOAT and form a small bead in between two bricks of AVCOAT, ii) a silicone rubber with different thermophysical properties than AVCOAT fills the gap between two bricks of AVCOAT. I created a thermal model using TD to determine temperature differences that are caused by these two features. To prevent false results, all TD models must be verified against something known. In this case, the TD model was correlated to CHAR, an ablation modelling software used to analyze TPS. Analyzing a node far from the concerning features, we saw that the TD model data match CHAR data, verifying the TD model. Next, the temperature of the silicone rubber as well as the bead of adhesive were analyzed to determine if they exceeded allowable temperatures. It was determined that these two features do not have a significant effect on the max temperature of the heat shield. This model can be modified to check temperatures at various locations of the heat shield where the composite thickness varies.

Hasnain, Aqib↗

Life characteristics assessment of the communications technology satellite transmitter experiment package

The performance characteristics of the transmitter experiment package (TEP) aboard the Communications Technology Satellite (CTS) measured during its first 2 years in orbit are presented. The TEP consists of a nominal 200 watt output stage tube (OST), a supporting power processing system (PPS), and a variable conductance heat pipe system (VCHPS). The OST, a traveling wave tube augmented with a 10 stage depressed collector has an overall saturated average efficiency of 51.5 percent and an average saturated radio frequency (rf) output power at center band frequency of 240 watts. The PPS operated with a measured efficiency of 86.5 to 88.5 percent. The VCHPS, using three pipes to conduct heat from the PPS and the OST to a 52 by 124 centimeter radiator fin, maintained the PPS baseplate temperature below 50 C for all operating conditions. The TEP performance characteristics presented include frequency response, rf output power, thermal performance, and efficiency. Communications characteristics were evaluated by using both video and audio modulated signals. On four occasions, the TEP experienced temporary thermal control system malfunctions. The anomalies were terminated safely, and the problem was investigated because of the potential for TEP damage due to the signficant temperature increases. Safe TEP operating procedures were established.

Smetana, J.↗

Gas dynamics in the impulsive phase of solar flares. I Thick-target heating by nonthermal electrons

A numerical investigation is carried out of the gas dynamical response of the solar atmosphere to a flare energy input in the form of precipitating nonthermal electrons. Rather than discussing the origin of these electrons, the spectral and temporal characteristics of the injected flux are inferred through a thick-target model of hard X-ray bremsstrahlung production. It is assumed that the electrons spiral about preexisting magnetic field lines, making it possible for a one-dimensional spatial treatment to be performed. It is also assumed that all electron energy losses are due to Coulomb collisions with ambient particles; that is, return-current ohmic effects and collective plasma processes are neglected. The results are contrasted with earlier work on conductive heating of the flare atmosphere. A local temperature peak is seen at a height of approximately 1500 km above the photosphere. This derives from a spatial maximum in the energy deposition rate from an electron beam. It is noted that such a feature is not present in conductively heated models. The associated localized region of high pressure drives material both upward and downward.

Nagai, F.↗

Early performance of the 12-GHz, 200-watt transmitter experiment package in the communications technology satellite

Measured performance characteristics of the transmitter experiment package (TEP) aboard the Communications Technology Satellite for the first 90 operating days in orbit are presented. The TEP consists of a nominal 200-watt output stage tube (OST), a supporting power processing system (PPS), and a variable-conductance heat pipe system (VCHPS). The OST, a traveling-wave tube augmented with a 10-stage depressed collector, has an overall saturated average efficiency of 51.5 percent and an average saturated radiofrequency (RF) output power at center-band frequency of 240 watts. The PPS operated with a measured efficiency of 86.5 percent to 88.5 percent. The VCHPS, using three pipes to conduct heat from the PPS and the body of the OST to a 52-centimeter by 124-centimeter (20.5-in. by 48.75-in.) radiator fin, maintained by the PPS baseplate temperature below 50 C for all operating conditions. The TEP performance characteristics presented include frequency response, RF output power, efficiency, and distortions. Communications characteristics were evaluated by using both video and audio modulated signals.

Source record↗

Numerical simulation of two-dimensional heat transfer in composite bodies with application to de-icing of aircraft components

Transient, numerical simulations of the de-icing of composite aircraft components by electrothermal heating were performed for a two dimensional rectangular geometry. The implicit Crank-Nicolson formulation was used to insure stability of the finite-difference heat conduction equations and the phase change in the ice layer was simulated using the Enthalpy method. The Gauss-Seidel point iterative method was used to solve the system of difference equations. Numerical solutions illustrating de-icer performance for various composite aircraft structures and environmental conditions are presented. Comparisons are made with previous studies. The simulation can also be used to solve a variety of other heat conduction problems involving composite bodies.

Chao, D. F. K.↗

Lunar thermal regime to 300 km

Coupling of the global heat flow, crustal heat source enrichment, thermal conductivity, and temperature in the crust and upper mantle of the moon is examined. A steady-state moon in which conductive heat transfer dominates is assumed. Heat-flow measurements from the Apollo 15 and 17 missions and gamma-ray mapping of thorium conducted by the Apollo 15 and 16 missions provide data for the study of the lunar thermal regime. Temperatures in the range of 1100 to 1600 K are found for the 300-km depth level. In the upper mantle, temperature gradients are in the range of 1.8 to 3.2 K/km.

Keihm, S. J.↗

Solar wind theory and modelling

The outflow of coronal plasma into interplanetary space is a consequence of the coronal heating process. Therefore the formation of the corona and the acceleration of the solar wind should be treated as a single problem. Traditionally the mass or particle flux emanating from the extended corona has been thought of as being determined by the coronal temperature or scale height and the coronal (base) density. This argument follows from considerations of the momentum balance of the corona-wind system from which one obtains models of a close to hydrostatic corona out to the critical point where the flow becomes supersonic. With this approach to the acceleration of the wind is has been difficult to reconcile the relatively small variation observed in the proton flux at 1 AU with the predicted exponential dependence of the proton flux on the coronal temperature. In this talk we would like to emphasize another approach in which coronal energetics play the primary role. The deposition of energy into the corona through some 'mechanical' energy flux is balanced by the various energy sinks available to the corona and the sum of these processes determine the coronal structure, i.e. its temperature and density. The corona loses energy through heat conduction into the transition region, through radiative losses, and through the gravitational potential energy and kinetic energy put into the solar wind itself. We will show from a series of models of the chromosphere transition region-corona-solar wind system that most of the energy deposited in a magnetically open region will go into the solar wind, with roughly half going into kinetic energy and half into lifting the plasma out of the solar gravity field. The coronal base density will adjust itself in such a way that the heat conductive flux flowing into the transition region is radiated away in the upper chromosphere. The coronal temperature is set by the requirements that most of the deposited energy goes into accelerating the solar wind; the coronal scale height will adjust itself so that the solar wind energy losses conform to the amplitude of the input energy. These processes are modified by the 'mode' of energy deposition, and we will show the effects on coronal structure of changing the parameters describing coronal heating as well as the effects of including a helium fluid in the models. However, the location, scale height and/or form of the energy deposition (i.e. heating or direct acceleration) are not too important for the solar wind, the coronal density and temperature structure will vary with the 'mode' of energy deposition, but the solar wind mass flux depends mainly on the amplitude of the energy flux.

Hansteen, Viggo H.↗

Thermal Technology Development Activities at the Goddard Space Flight Center: 2001

Activities include the development of two phase systems which are composed of 1) heat pipes and variable conductance heat pipes, 2)capillary pumped loops, 3) loop heat pipes, 4) vapor compression systems (heat pumps), 5) phase change materials. Also in the development phase are variable emittance surfaces, advanced coatings, high conductivity materials, and electrohydrodynamic (EHD) thermal control systems.

Butler, Dan↗

The friable sponge model of a cometary nucleus

The mantle/core model of cometary nuclei, first suggested by Whipple and subsequently developed by Mendis and Brin, is modified and extended. New terms are added to the heat conduction equation for the mantle, which is solved in order to obtain the temperature distribution in the mantle and the gas production rate as a function of mantle thickness and heliocentric distance. These results are then combined with some specific assumptions about the mantle structure (the friable sponge model) in order to make predictions for the variation of gas production rate and mantle thickness as functions of heliocentric distance for different comets. A solution of the time-dependent heat conduction equation is presented in order to check some of the assumptions.

Horanyi, M.↗

Macroscopic Lagrangian description of warm plasmas. I Formulation of the Lagrangian

A macroscopic Lagrangian is derived which includes a pressure tensor, heat conduction, and elastic collisions. Its Euler-Lagrange equations are shown to be the Maxwell equations and the macroscopic force law. The corresponding Hamiltonian is derived, and Hamilton's canonical equations are also demonstrated to lead to the Maxwell equations and the macroscopic force law. The treatment is facilitated by working in a mixture of Eulerian coordinates (for the fields) and Lagrangian coordinates (for the particle motions), and the introduction of a macroscopic potential expressed in terms of the plasma thermal energy and the energy losses by heat conduction.

Peng, Y.-K. M.↗