Search NASA⌕ Search

SEARCH · Search NASA

Results for “installed power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

TEAMER: MADWEC Techno-Economic Analysis

The objective of this project was for the facility to conduct a techno-economic assessment (TEA) of the Maximal Asymmetric Drag Wave Energy Converter (MADWEC), developed by the University of Massachusetts Dartmouth (UMass Dartmouth). MADWEC is used for powering remote monitoring and Autonomous Underwater Vehicle (AUV) charging systems compared to other existing power supply options. The assessment estimates capital expenditures (CapEx), operational expenditures (OpEx), and power performance for 18 scenarios with the purpose of identifying key cost drivers, comparing total system cost, and comparing the power performance of the power supply options in terms of required installed capacity and estimated theoretical annual energy performance. The 18 assessed scenarios include two end-uses: 1) AUV charging and 2) offshore remote monitoring); three power sources: 1) MADWEC), 2) photovoltaic (PV) solar buoy, 3) and traditional battery swapping); and three locations; 1) nearshore, 2) far-offshore, and 3) high-latitude). In addition, other project goals included developing high level installation, operation, and maintenance plans for each scenario. The techno-economic model, created in Microsoft Excel, estimates CapEx, OpEx, and the power performance of each power supply source. The model has a dynamic format that allows custom inputs to accommodate future changes to the systems being assessed. This is a TEA for the MADWEC project, TEAMER RFTS 7 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Conceptual Design of Propulsors for the SUSAN Electrofan Transport Aircraft

Conceptual designs of the propulsor modules for the SUSAN electro-fan aircraft are sought after. Shaft power requirement is reduced by using boundary layer ingesting propulsion technology. There are several obstacles to designing feasible BLI propulsion systems such as inlet distortion, flow blockage from ingesting low-momentum flow, strong coupling between airframe and propulsion systems. Thus, the high fidelity CFD tool is indispensable to assess the performance of the propulsion systems and evaluate the inlet profiles during the design process. Consequently, the CFD data is used to update the inputs for the NPSS model from the initial stage of the system design. Hence, the inlet sizing, fan design, and estimation of the power saving are carried out. Various installation concepts of the mail-slot nacelle, such as under-/over-wing and trailing edge configurations, are investigated for the wing-mounted turbo-electric distributed propulsor module, and their power-saving is evaluated. As for the tail-mounted turbofan engine, the fan diameter and inlet captured area is determined based on the CFD profiles. An appropriate area ratio of the bypass and core ducts is derived from meeting the target bypass ratio from the system design. The baseline fan stage is analyzed by full annulus URANS CFD to assess the efficiency penalty due to the ingested pressure and swirl distortions.

SUSAN Electro-Fan Aircraft↗

Conceptual Design of Propulsors for the SUSAN Electrofan Transport Aircrafts

Conceptual designs of the propulsor modules for the SUSAN electro-fan aircraft are sought after. Shaft power requirement is reduced by using boundary layer ingesting propulsion technology. There are several obstacles to designing feasible BLI propulsion systems such as inlet distortion, flow blockage from ingesting low-momentum flow, strong coupling between airframe and propulsion systems. Thus, the high fidelity CFD tool is indispensable to assess the performance of the propulsion systems and evaluate the inlet profiles during the design process. Consequently, the CFD data is used to update the inputs for the NPSS model from the initial stage of the system design. Hence, the inlet sizing, fan design, and estimation of the power saving are carried out. Various installation concepts of the mail-slot nacelle, such as under-/over-wing and trailing edge configurations, are investigated for the wing-mounted turbo-electric distributed propulsor module, and their power-saving is evaluated. As for the tail-mounted turbofan engine, the fan diameter and inlet captured area is determined based on the CFD profiles. An appropriate area ratio of the bypass and core ducts is derived from meeting the target bypass ratio from the system design. The baseline fan stage is analyzed by full annulus URANS CFD to assess the efficiency penalty due to the ingested pressure and swirl distortions.

Electric Aircraft↗

Smart Microgrids

The Nation’s electrical power depends on one bulk power grid to support security and economic prosperity. According to the Department of Homeland Security’s Homeland Threat Assessment of 2020, the largest cyber threat to homeland security is potential disruption to critical infrastructure, including power grids. Critical infrastructure includes the physical and cyber systems which generate, transmit, and distribute electricity with an impact on economic security, public health, or safety. The surety of the Nation’s power grid is vital for providing essential services and would put the population at risk if disrupted. Power outages can have catastrophic consequences for critical organizations such as hospitals and military installations. Additionally, the current fossil-fuel dependent power grid is extremely fragile and vulnerable to overloads, storms that destroy power lines, and cyber-attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power components for the space station 20-kHz power distribution system

Since 1984, NASA Lewis Research Center was developing high power, high frequency space power components as part of The Space Station Advanced Development program. The purpose of The Advanced Development program was to accelerate existing component programs to ensure their availability for use on the Space Station. These components include a rotary power transfer device, remote power controllers, remote bus isolators, high power semiconductor, a high power semiconductor package, high frequency-high power cable, high frequency-high power connectors, and high frequency-high power transformers. All the components were developed to the prototype level and will be installed in the Lewis Research Center Space Station power system test bed.

Renz, David D.↗

Power components for the Space Station 20-kHz power distribution system

Since 1984, NASA Lewis Research Center was developing high power, high frequency space power components as part of The Space Station Advanced Development program. The purpose of the Advanced Development program was to accelerate existing component programs to ensure their availability for use on the Space Station. These components include a rotary power transfer device, remote power controllers, remote bus isolators, high power semiconductor, a high power semiconductor package, high frequency-high power cable, high frequency-high power connectors, and high frequency-high power transformers. All the components were developed to the prototype level and will be installed in the Lewis Research Center Space Station power system test bed.

Renz, David D.↗

Multi-Timescale Integrated Dynamic and Scheduling Model (MIDAS-Solar)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power system operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power systems steady-state and dynamic performance. This project helps meet and exceed the Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for electric grid planning and operation. This will be accomplished by developing temporally comprehensive, closed-loop simulation models that seamlessly simulate power systems operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). Both a multi-timescale grid model and an integrated PV model will be developed in this project to accurately study the impacts of PV variability and uncertainty on system reliability at multiple timescales. Using quasi-dynamic simulation methods and data-driven security assessment (DSA) criteria will allow the dynamic characteristics of PV to be fed forward into longer-timescale scheduling models for a complete understanding of the effect of short-term PV dynamics on bulk systems operations (e.g., reserve scheduling and deployment). Upon completion of the proposed model, this project will help operators accurately assess system reliability by deploying energy and reserve scheduling under critical contingency conditions and studying interactions among all types of essential reliability services provided by modern PV power plants.

14 SOLAR ENERGY↗

Power system interface and umbilical system study

System requirements and basic design criteria were defined for berthing or docking a payload to the 25 kW power module which will provide electrical power and attitude control, cooling, data transfer, and communication services to free-flying and Orbiter sortie payloads. The selected umbilical system concept consists of four assemblies and command and display equipment to be installed at the Orbiter payload specialist station: (1) a movable platen assembly which is attached to the power system with EVA operable devices; (2) a slave platen assembly which is attached to the payload with EVA operable devices; (3) a fixed secondary platen permanently installed in the power system; and (4) a fixed secondary platen permanently installed on the payload. Operating modes and sequences are described.

Source record↗

An electric propulsion long term test facility

An existing test facility was modified to provide for extended testing of multiple electric propulsion thruster subsystems. A program to document thruster subsystem characteristics as a function of time is currently in progress. The facility is capable of simultaneously operating three 2.7-kW, 30-cm mercury ion thrusters and their power processing units. Each thruster is installed via a separate air lock so that it can be extended into the 7m x 10m main chamber without violating vacuum integrity. The thrusters exhaust into a 3m x 5m frozen mercury target. An array of cryopanels collect sputtered target material. Power processor units are tested in an adjacent 1.5m x 2m vacuum chamber or accompanying forced convection enclosure. The thruster subsystems and the test facility are designed for automatic unattended operation with thruster operation computer controlled. Test data are recorded by a central data collection system scanning 200 channels of data a second every two minutes. Results of the Systems Demonstration Test, a short shakedown test of 500 hours, and facility performance during the first year of testing are presented.

Trump, G.↗

Hydrogen Mitigation Process Installation at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) have developed and are implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure—from 1.33 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. We demonstrated the performance of a laboratory-scale version of this module. Testing showed that the module performed as expected: the accuracy of the sensing function was ±7%, and the hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP planned, specified, and designed a mitigation process that is based on the integrated module. We are currently completing installation of this process at ASP's Nevada Solar One power plant in Boulder City, Nevada, USA. The mitigation process is being installed at ground level below the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. In this paper, we report progress on the installation and describe some of the many design details and challenges that we addressed during the past year. We will generate initial performance data from the Nevada Solar One mitigation process in early 2020.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Development of a uninterrupted power system: ac and dc to dc converter

This program covered the design, fabrication and testing of an advanced development model uninterrupted power system. The input and output requirements imposed on the power processor were specified such that the unit is electrically interchangeable with existing power systems used by the Federal Aviation Administration in installations which have a history of failure due to electrical transient conditions. Input power is from either of two single-phase ac power sources or batteries with electronic selection and transfer between power sources. Battery reconditioning is automatic when either ac source is present. The output power is rated at 84OW; the nominal output is 24V at 35A. Within the 84OW limit, the regulated output voltage is adjustable from 22V to 30Vdc. Protection against continuous overloading or short circuit is provided. The unit is packaged in a standard 19-inch rack mount configuration with 7-inch panel height. Controls are on the front panel with power input and output through connectors on the rear surface. Cooling is by free convection from fin areas located on the side and rear panels. The packaged unit weighs 52.8 lbs., which can be reduced significantly if a three-phase ac power source is used.

Cronin, D. L.↗

Wind turbine generator interaction with conventional diesel generators on Block Island, Rhode Island. Volume 1: Executive summary

Primary results are summarized for a three-part study involving the effects of connecting a MOD-OA wind turbine generator to an isolated diesel power system. The MOD-OA installation considered was the third of four experimental nominal 200 kW wind turbines connected to various utilities under the Federal Wind Energy Program and was characterized by the highest wind energy penetration levels of four sites. The study analyses address: fuel displacement, dynamic interaction, and three modes of reactive power control. These analyses all have as their basis the results of the data acquisition program conducted on Block Island, Rhode Island.

Wilreker, V. F.↗

COG User's Manual: A Multiparticle Monte Carlo Transport Code (Sixth Edition)

COG is a high-resolution code for the Monte Carlo simulation of coupled particle transport in arbitrary 3-D geometry. COG will transport neutrons, protons, deuterons, alpha particles with energies up to hundreds of GeV, and photons with energy ranges limited by the available cross section sets and physics models. Electrons can be transported via the EGS5 electron transport kernel, electrons can also be transported. The COG code is a significant upgrade from earlier Monte Carlo transport codes and has been written specifically to make it more versatile, accurate, and easy to use. COG has provisions for calculating deep penetration (shielding) problems, criticality problems, and neutron activation problems while retains all of the standard capabilities found in other Monte Carlo transport codes. COG uses high-resolution pointwise cross-section databases and makes no compromises in the transport physics, so that the results of a COG run are limited only by the accuracy of the databases used. COG runs primarily on Linux Operating System workstations with MPICH software installed – currently, Red Hat 7 & 8, Windows 10 (Windows Subsystem for Linux –WSL), Ubuntu 16, 18 & 20, OpenSUSE Leap 15.2, Fedora 32, Apple Power Mac with Intel CPU (with MacPorts installed) workstations, and LLNL LC supercomputer CTS-1 cluster with TOSS 3 are supported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Considerations for Fire Service Response to Residential Battery Energy Storage System Incidents

Renewable energy sources (e.g., rooftop photovoltaics, wind turbines) are capable of addressing our grid-level energy challenges by reducing environmental impacts, increasing resiliency, and increasing the supply of input energy. However, renewable energy sources alone are not a complete solution. The generation of power from major renewable energy sources fluctuates with the weather, creating significant challenges in matching electrical power generation to electrical power consumption. The value of renewable power generation sources is multiplied when paired with battery energy storage systems (ESS), which can store excess power generated from renewable energy sources when it is not consumed and deliver that power later when demand exceeds base power generation. Residential ESS units are frequently installed to support renewable energy initiatives by storing energy from intermittent sources such as photovoltaic panels. Residential ESS units also offer an alternative to gas-powered generators or other backup power means. Lithium-ion batteries are the most common residential ESS technology due to their affordability and energy density. Though lithium-ion systems come with benefits, there is also a risk of thermal runaway within this technology which can result in flammable gas release, fire, and explosion. As the installations of these products increase, the frequency of response to fire incidents involving these products will increase. In response to this new and evolving hazard, UL Solutions (ULS) and UL Fire Safety Research Institute (FSRI) have partnered with the International Association of Fire Fighters (IAFF) to conduct a series of large-scale tests sponsored by the US Department of Energy to characterize the challenges for fire fighters responding to fires involving residential energy storage systems. The project focuses on developing size-up and tactical considerations to support the fire service in navigating the evolving modern fireground.

25 ENERGY STORAGE↗

Analysis of payload bay magnetic fields due to dc power multipoint and single point ground configurations

An analysis of magnetic fields in the Orbiter Payload Bay resulting from the present grounding configuration (structure return) was presented and the amount of improvement that would result from installing wire returns for the three dc power buses was determined. Ac and dc magnetic fields at five points in a cross-section of the bay are calculated for both grounding configurations. Y and Z components of the field at each point are derived in terms of a constant coefficient and the current amplitude of each bus. The dc loads assumed are 100 Amperes for each bus. The ac noise current used is a spectrum 6 db higher than the Orbiter equipment limit for narrowband conducted emissions. It was concluded that installing return wiring to provide a single point ground for the dc Buses in the Payload Bay would reduce the ac and dc magnetic field intensity by approximately 30 db.

Lawton, R. M.↗

Internal Radio-Frequency Instrumentation System (IRIS) Overview

Wireless instrumentation has long been sought for spaceflight applications, but practical implementations capable of providing the utility of wired sensors have proven elusive. The power needed to drive transmitters/receivers in traditional "active" wireless sensor radios requires either frequent battery replacement or prohibitive duty cycling. This prevents installing such sensors early in a vehicle's integration and treating them as always-on throughout its operation. "Passive" solutions such as radio frequency identification (RFID) techniques provide an appealing alternative, though most common RFID sensing approaches such as surface acoustic wave (SAW) RFID do not lend themselves easily to integrating arbitrary suites of sensors and sensor processors. In this talk we detail the design, fabrication, and evaluation of the Internal Radio-frequency Instrumentation System (IRIS), an RFID-enabled instrumentation solution that integrates an EPC Global Class 1 Generation 2 interface with processor-based wireless sensors. IRIS thermocouple sensors can operate in a low-power hibernation state with instantaneous over-the-air wakeup for nearly a decade on a small (255 mAh) coin cell battery. In their active state, they can acquire and stream 10 Hz data for more than 200 days. This allows wireless sensors to be installed and powered on early in vehicle integration and continue to operate after launch through a lengthy mission, opening the vehicle design trade space to wireless sensing in a meaningful and unprecedented way.

Wagner, Raymond↗

A photovoltaic power system and a low-power satellite earth station for Indonesia

A photovoltaic power system and a low-power, two-way satellite earth station have been installed at Wawotobi, Sulawesi, Indonesia to provide university classroom communications for audio teleconferencing and video graphics. This project is a part of the Agency for International Development's Rural Satellite Program. The purpose of this program is to demonstrate the use of satellite communications for development assistance applications. The purpose of the photovoltaic power system is to demonstrate the suitability of a hybrid photovoltaic/engine-generator power system for a remote satellite earth station. This paper describes the design, installation and initial operation of the photovoltaic power system and the earth station.

Delombard, Richard↗

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗