Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic threat recognition system and method using material disambiguation informed by physics in x-ray CT images of baggage

An automatic threat recognition (ATR) system is disclosed for scanning an article to recognize contraband items or items of interest contained within the article. The ATR system uses a CAT scanner to obtain a CT image scan of objects within the article, representing a plurality of 2D image slices of the article and its contents. Each 2D image slice includes information forming a plurality of voxels. The ATR system includes a computer and determines which voxels have a likelihood of representing materials of interest. It then aggregates those voxels to produce detected objects. The detected objects are further classified as items of interest vs. not of interest. The ATR system is based on learned parameters for a novel interaction of global and object context mechanisms. ATR system performance may be optimized by using jointly optimal global and object context parameters learned during training. The global context parameters may apply to the article as a whole and facilitate object detection. The object context parameters may apply to the individual object detections.

Paglieroni, David W.↗

Single-shot in-line x-ray phase-contrast imaging of void-shockwave interactions in fusion energy materials

Recent breakthroughs in nuclear fusion, specifically the report of reactions exceeding scientific breakeven at the National Ignition Facility (NIF), highlight the potential of inertial fusion energy (IFE) as a sustainable and virtually limitless energy source. However, further progress in IFE requires characterization of defects in ablator materials and how they affect fuel capsule compression. Voids within the ablator can degrade energy yield, but their impact on the density distribution has primarily been studied through simulations, with limited high-resolution experimental validation. To address this, we used the x-ray free-electron laser (XFEL) at the matter in extreme conditions (MECs) instrument at the Linac coherent light source (LCLS) to capture 2D x-ray phase-contrast (XPC) images of a void-bearing sample with a composition similar to inertial confinement fusion (ICF) ablators. By driving a compressive shockwave through the sample using MEC's long-pulse laser system, we analyzed how voids influence shockwave propagation and density distribution during compression. To quantify this impact, we extracted phase information using two phase retrieval algorithms. First, we applied the contrast transfer function (CTF) method, paired with Tikhonov regularization and a fast optimization approach to generate an initial phase estimate. We then refined the result using a projected gradient descent (PGD) method that works directly with the sample's refractive index. Comparing these results with radiation adaptive grid Eulerian (xRAGE) radiation hydrodynamic simulations enables identification of model validation needs or improvements. By calculating phase maps in situ, it becomes possible to reconstruct areal density maps, improving understanding of laser-capsule interactions and advancing IFE research.

Hodge, D. S. [Colorado State Univ., Fort Collins, ↗

Life Expectancy of Evaporating Capillary Bridges Predicted by Tertiary Creep Modeling

The evaporation of capillary bridges is experimentally investigated at the microscale through a three-grain capillary cluster. This setting provides the minimum viable description of Haines jumps during evaporation, that is, capillary instabilities stemming from air entry into a saturated granular material. The displacement profile of a meniscus is obtained via digital image correlation for different grain materials, geometries, and separations. While it is well known that Haines jumps are triggered at the pore throat, we find that these instabilities are of three types depending on the separation. We also provide a temporal characterization of Haines jumps; we find that they are accurately described, as tertiary creep instabilities, by Voight’s relation, similarly to landslides and volcanic eruptions. This finding extends the description of capillary instabilities beyond their onset predicted by Laplace equilibrium. Our contribution also paves the way for a microscopically-informed description of desiccation cracks, of which Haines jumps are the precursors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis‐Related Nanoscale Defects in Mo‐Based Janus Monolayers Revealed by Cross‐Correlated AFM and TERS Imaging

2D Janus transition metal dichalcogenides (TMDs) are promising candidates for various applications including non-linear optics, energy harvesting, and catalysis. These materials are usually synthesized via chemical conversion of pristine TMDs. Nanometer-scale characterization of the obtained Janus materials’ morphology and local composition is crucial for both the synthesis optimization and the future device applications. In this work, we present the results of cross-correlated atomic force microscopy (AFM) and tip-enhanced Raman spectroscopy (TERS) study of Janus monolayers synthesized by the hydrogen plasma-assisted chemical conversion of MoSe 2 and MoS 2 . We demonstrate that the choice of both the growth substrate and the starting TMD influences the residual strain, thereby shaping the nanoscale morphology of the resulting Janus material. Furthermore, by employing TERS imaging, we show the presence of nanoscale islands (≈20 nm across) of MoSe 2 - ${\mathrm{Mo}}_{{\mathrm{Se}}}^{\mathrm{S}}$ (MoS 2 -${\mathrm{Mo}}_{\mathrm{S}}^{{\mathrm{Se}}}$) vertical heterostructures originating from the bilayer nanoislands in the precursor monolayer crystals. The understanding of the origins of nanoscale defects in Janus TMDs revealed in this study can help with further optimization of the Janus conversion process towards uniform and wrinkle-/crack-free Janus materials. Moreover, this work shows that cross-correlated AFM and TERS imaging is a powerful and accessible method for studying nanoscale composition and defects in Janus TMD monolayers.

2D materials↗

Tutorial on In Situ and Operando (Scanning) Transmission Electron Microscopy for Analysis of Nanoscale Structure–Property Relationships

In situ and operando (scanning) transmission electron microscopy [(S)TEM] is a powerful characterization technique that uses imaging, diffraction, and spectroscopy to gain nano-to-atomic scale insights into the structure–property relationships in materials. This technique is both customizable and complex because many factors impact the ability to collect structural, compositional, and bonding information from a sample during environmental exposure or under application of an external stimulus. In the past two decades, in situ and operando (S)TEM methods have diversified and grown to encompass additional capabilities, higher degrees of precision, dynamic tracking abilities, enhanced reproducibility, and improved analytical tools. Much of this growth has been shared through the community and within commercialized products that enable rapid adoption and training in this approach. This tutorial aims to serve as a guide for students, collaborators, and nonspecialists to learn the important factors that impact the success of in situ and operando (S)TEM experiments and assess the value of the results obtained. As this is not a step-by-step guide, readers are encouraged to seek out the many comprehensive resources available for gaining a deeper understanding of in situ and operando (S)TEM methods, property measurements, data acquisition, reproducibility, and data analytics.

(S)TEM↗

Effect of grain size on damage and failure in two-phase materials: Homogenized CuPb

It is well known that spall failure strongly depends on the microstructure of a material. There have been numerous studies to study the effect of grain size on the overall spall strength and the total amount of damage in single element metals like copper. However, such systematic studies remain rare in two-phase materials and alloys. In this work, two incipient spall experiments were performed on a Cu–1%Pb alloy to understand the effect of grain size on the damage and failure in a two-phase material. Overall, these results showed that even though the spall strength did not change as a function of grain size, there were significant differences in the total amount of damage as a function of grain size. A clear increase in the total damage present in the material was seen as the grain size was increased from 32 to either 70 or 75 μm in either of the experiments. Furthermore, this difference was attributed to variations in the void growth rate as the grain size was increased.

36 MATERIALS SCIENCE↗

Scaling behavior of low-temperature orthorhombic domains in the prototypical high-temperature superconductor La 1.875 Ba 0.125 CuO 4

Structural symmetry breaking and recovery in condensed-matter systems are closely related to exotic physical properties such as superconductivity (SC), magnetism, spin density waves, and charge density waves (CDWs). The interplay between different order parameters is intricate and often subject to intense debate, as in the case of CDW order and superconductivity. In La 1.875 Ba 0.125 CuO 4 (LBCO), the low-temperature structural domain walls are hypothesized as nanometer-scale pinning sites for the CDWs. Coherent x-ray diffraction techniques have been employed here to visualize the domain structures associated with these symmetry changes directly during phase transition. We have pushed Bragg coherent diffractive imaging (BCDI) into the cryogenic regime where most phase transitions in quantum materials reside. Utilizing BCDI, we image the structural evolution of LBCO microcrystal samples during the high-temperature tetragonal to low-temperature orthorhombic (LTO) phase transition. Our results show the formation of LTO domains close to the transition temperature and how the domain size decreases with temperature. In conclusion, the number of domains follows the secondary order parameter (or orthorhombic strain) measurement with a critical exponent that is consistent with the three-dimensional universality class.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ELASTOMERIC MICROVASCULAR SELF-HEALING MATERIALS

Damaged elastomeric diaphragms within pneumatic controllers used in the oil and gas industry lead to an unintended release of methane. Self-healing microvascular materials capable of healing various types of damage have been fabricated. These microvascular materials are designed to replace currently available commercial diaphragms found in pneumatic controllers and provide a solution to reduce unintended methane leaks. Poly(dimethylsiloxane) (PDMS) was used as the main matrix material, with additional testing conducted on polyurethane and flexibilised epoxy materials. Microvascular networks were implemented into the elastomeric membranes to act as ves- sels to deliver healing agents to the damaged areas. The complex, interdigitated channel networks were created using a 3D printed custom compounded filament composed of polylactic acid (PLA) and tin(II) oxalate. Two-part liquid casting polymers were poured around the channels into a mould to create samples with the scaffolding of the microvascular channels intact. Hollow microvascular networks were created by placing the samples within a vacuum oven at 250◦C which causes the thermal depolymerisation of PLA into its gaseous monomers. The manufactured materials were placed in test stands and pressurized using nitrogen gas to determine their healing and mechanical behaviour. Self-healing behaviour was demonstrated using PDMS matrix materials and healing chemistries within a pressure test cell. This test cell was designed to detect any damage to a sample by record- ing an outlet pressure. Damages including puncture holes, diagonal cuts and star-shaped central iv cuts were applied to the samples and a reduction in the outlet pressure was recorded for all sam- ples. A variation in channel spacing and diameter was studied to determine the optimal design of the microvascular network for self-healing performance. The mechanical performance of elastomeric membrane materials within a diaphragmatic pressurised stand was observed. Deformations and strains around the channels and channel inter- sections at the midplane of the materials were recorded using digital image correlation. Normal stresses were calculated using Hooke’s law and the material properties of the PDMS matrix. A reduction in leak rate, implying the success of self-healing, was recorded within manu- factured diaphragm samples tested within a commercial valve. PDMS is the favourable material when compared to polyurethane and flexibilised epoxy for creating

03 NATURAL GAS↗

2D perovskite-based high spatial resolution X-ray detectors

Abstract X-ray radiography is the most widely used imaging technique with applications encompassing medical and industrial imaging, homeland security, and materials research. Although a significant amount of research and development has gone into improving the spatial resolution of the current state-of-the-art indirect X-ray detectors, it is still limited by the detector thickness and microcolumnar structure quality. This paper demonstrates high spatial resolution X-ray imaging with solution-processable two-dimensional hybrid perovskite single-crystal scintillators grown inside microcapillary channels as small as 20 µm. These highly scalable non-hygroscopic detectors demonstrate excellent spatial resolution similar to the direct X-ray detectors. X-ray imaging results of a camera constructed using this scintillator show Modulation Transfer Function values significantly better than the current state-of-the-art X-ray detectors. These structured detectors open up a new era of low-cost large-area ultrahigh spatial resolution high frame rate X-ray imaging with numerous applications.

2D perovskite↗

Cryogenic electron tomography by the numbers: Charting underexplored lineages in structural cell biology

Imaging cells and their interactions across the whole biosphere with molecular-scale resolution is key for understanding structure–function relations. Cryogenic electron tomography (cryo-ET) is a powerful method for obtaining this critical information. However, cryo-ET studies are challenging and often limited to a small number of cell types per study. Here, we collate cryo-ET data from hundreds of cells and tissues across the biosphere to i) identify emerging methodological trends, ii) pinpoint strategies to reduce imaging time and costs, iii) quantitatively compare methods for cell freezing and sectioning, and iv) census cryo-ET species coverage across all domains of life. Comparing the fraction of cellular material within a single lamella across all domains of life reveals an order of magnitude difference between eukaryotes (1%) compared to bacteria (9%) and archaea (14%). We calculate the fraction of cellular material which can be imaged using distinct sectioning methods on multicellular communities and tissues—identifying serial lift-out as a powerful approach for obtaining more complete cellular depictions. Finally, we show that the biodiversity of current cryo-ET studies is 2 to 3 orders of magnitude lower than in sequence libraries and 4 to 5 lower than the total predicted on Earth. Our analyses reveal major evolutionary lineages which remain critically understudied and highlight where future cryo-ET research would be most impactful.

HPF↗

Imaging the electron charge density in monolayer MoS 2 at the Ångstrom scale

Four-dimensional scanning transmission electron microscopy (4D-STEM) has recently gained widespread attention for its ability to image atomic electric fields with sub-Ångstrom spatial resolution. These electric field maps represent the integrated effect of the nucleus, core electrons and valence electrons, and separating their contributions is non-trivial. In this paper, we utilized simultaneously acquired 4D-STEM center of mass (CoM) images and annular dark field (ADF) images to determine the projected electron charge density in monolayer MoS 2 . We evaluate the contributions of both the core electrons and the valence electrons to the derived electron charge density; however, due to blurring by the probe shape, the valence electron contribution forms a nearly featureless background while most of the spatial modulation comes from the core electrons. Our findings highlight the importance of probe shape in interpreting charge densities derived from 4D-STEM and the need for smaller electron probes.

36 MATERIALS SCIENCE↗

An image-driven machine learning approach to kinetic modeling of a discontinuous precipitation reaction

Micrograph quantification is an essential component of several materials science studies. Machine learning methods, in particular convolutional neural networks, have previously demonstrated performance in image recognition tasks across several disciplines (e.g. materials science, medical imaging, facial recognition). Here, we apply these well-established methods to develop an approach to microstructure quantification for kinetic modeling of a discontinuous precipitation reaction in a case study on the uranium-molybdenum system. Prediction of material processing history based on image data (classification), calculation of area fraction of phases present in the micrographs (segmentation), and kinetic modeling from segmentation results were performed. Results indicate that convolutional neural networks represent microstructure image data well, and segmentation using the k-means clustering algorithm yields results that agree well with manually annotated images. Classification accuracies of original and segmented images are both 94% for a 5-class classification problem. Kinetic modeling results agree well with previously reported data using manual thresholding. The image quantification and kinetic modeling approach developed and presented here aims to reduce researcher bias introduced into the characterization process, and allows for leveraging information in limited image data sets.

36 MATERIALS SCIENCE↗

High-Energy Coherent X-Ray Dffraction Microscopy of Polycrystal Grains: First Steps Towards a Multi-Scale Approach

Here, we present proof-of-concept imaging measurements of a polycrystalline material that integrate the elements of conventional high-energy x-ray diffraction microscopy with coherent diffraction-imaging techniques, and that can enable in situ strain-sensitive imaging of lattice structure in ensembles of deeply embedded crystals over five decades of length scale upon full realization. We demonstrate that the combination of these two characterization methods enables a more complete picture of the crystal-lattice strain than either method is capable of providing individually. Such complementary imaging capabilities are critical to addressing questions in a variety of research areas such as materials science and engineering, chemistry, and solid-state physics. Towards this eventual goal, the following key aspects are demonstrated: (1) high-energy Bragg coherent diffraction imaging (HE BCDI) of submicron-scale crystallites at 52 keV at current third-generation synchrotron light sources, (2) HE BCDI performed in conjunction with far-field high-energy diffraction microscopy (FF HEDM) on the grains of a polycrystalline sample in a smoothly integrated manner, and (3) the orientation information of an ensemble of grains obtained via FF HEDM used to perform complementary HE BCDI on multiple Bragg reflections of a single targeted grain. The imaged structures are seen to be 477 ± 50 nm or smaller in size, with an estimated strain resolution of 2.5 x 10 -4 . These steps lay the foundation for integration of HE BCDI, which typically provides a spatial resolution tens of nanometers, into a broad suite of well-established HEDM methods, extending HEDM beyond the few-micrometer resolution bound and into the nanoscale, and positioning the approach to take full advantage of the orders-of-magnitude improvement of x-ray coherence expected at fourth-generation light sources presently being built and commissioned worldwide.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parameters, Properties, and Process: Conditional Neural Generation of Realistic SEM Imagery Toward ML-Assisted Advanced Manufacturing

Abstract The research and development cycle of advanced manufacturing processes traditionally requires a large investment of time and resources. Experiments can be expensive and are hence conducted on relatively small scales. This poses problems for typically data-hungry machine learning tools which could otherwise expedite the development cycle. We build upon prior work by applying conditional generative adversarial networks (GANs) to scanning electron microscope (SEM) imagery from an emerging advanced manufacturing process, shear-assisted processing and extrusion (ShAPE). We generate realistic images conditioned on temper and either experimental parameters or material properties. In doing so, we are able to integrate machine learning into the development cycle, by allowing a user to immediately visualize the microstructure that would arise from particular process parameters or properties. This work forms a technical backbone for a fundamentally new approach for understanding manufacturing processes in the absence of first-principle models. By characterizing microstructure from a topological perspective, we are able to evaluate our models’ ability to capture the breadth and diversity of experimental scanning electron microscope (SEM) samples. Our method is successful in capturing the visual and general microstructural features arising from the considered process, with analysis highlighting directions to further improve the topological realism of our synthetic imagery.

36 MATERIALS SCIENCE↗

High-throughput terahertz imaging: progress and challenges

Abstract Many exciting terahertz imaging applications, such as non-destructive evaluation, biomedical diagnosis, and security screening, have been historically limited in practical usage due to the raster-scanning requirement of imaging systems, which impose very low imaging speeds. However, recent advancements in terahertz imaging systems have greatly increased the imaging throughput and brought the promising potential of terahertz radiation from research laboratories closer to real-world applications. Here, we review the development of terahertz imaging technologies from both hardware and computational imaging perspectives. We introduce and compare different types of hardware enabling frequency-domain and time-domain imaging using various thermal, photon, and field image sensor arrays. We discuss how different imaging hardware and computational imaging algorithms provide opportunities for capturing time-of-flight, spectroscopic, phase, and intensity image data at high throughputs. Furthermore, the new prospects and challenges for the development of future high-throughput terahertz imaging systems are briefly introduced.

36 MATERIALS SCIENCE↗

Atomic-Scale Imaging of Polarization Switching in an (Anti-)Ferroelectric Memory Material: Zirconia (ZrO2)

Direct, atomic-scale visualization of polarization switching in a functional, polycrystalline, binary oxide via in-situ high-resolution transmission electron microscopy (HRTEM) biasing is reported for the first time. Antiferroelectric (AFE) ZrO2 was used as the model system, which is important for commercial DRAMs and as emerging NVMs (through work-function engineering). We observed (1) clear shifting and coalescing of domains within a single grain, and (2) dramatic changes of the atomic arrangements and crystalline phases—both at voltages above the critical voltage measured for AFE switching. Similar synergistic in-situ structural-electrical characterization can pave the way to understand and engineer microscopic mechanisms for retention, fatigue, variability, sub-coercive switching and analog states in ferroelectric and AFE-based memory devices.

Lombardo, Sarah↗