Abstract for CRADA between NETL and Louisiana State University

The National Energy Technology Laboratory (NETL) and Louisiana State University (PARTICIPANT) will collaborate in developing and testing distributed optical fiber CO 2 sensors for CO 2 storage site monitoring. Safe and reliable monitoring of CO 2 storage sites and transport infrastructure is critical for ensuring the long-term effectiveness and integrity of carbon capture and storage (CCS). In this project, the objective is to develop a novel optical fiber-based distributed CO 2 sensor for long-term monitoring of CCS sites and CO 2 pipelines and also implement machine learning to automate leak and structural anomaly detection. This effort aligns with NETL’s mission in reliable and sustainable energy and decarbonization.

47 OTHER INSTRUMENTATION↗

TRUST Contact Thermal Conductance (TRUST-CTC) Report: FY24

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainties in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. Staff development will include cross-discipline collaboration to provide engineers with experience in both numerical simulations and experimental methods. This work uses and provides feedback on analysis tools and experimental results databases for efficient and responsive engineering which are currently under development. TRUST currently includes five testbeds and their associated engineering analysis baseline models (EABMs): 1. contact thermal conductivity, (CTC) 2. nonlinear dynamics, (ND) 3. sensors in environments for accelerometers, (SEA) 4. sensors in environments for fiber optic displacement gages, and (SEFOD) 5. sensors in environments for thermocouples (SETC). The TRUST project uses single-feature testbeds to quantify uncertainties in specific models and experiments and to identify capability development needs that can help to reduce these uncertainties. Each testbed is designed, configured, and tested in collaboration with groups with design and experimental capability: E-14 and MPA-CINT. The complementary simulations are conducted using W-13 analysis tools and stored in model repositories with plans for incremental progress toward EABM requirements. W-13 extends and exercises the testbed simulations in collaboration with experimentalists for uncertainty quantification of current and future materials, geometries, and environments. Additionally, TRUST is intended to provide engineers in W-13 and E-14 with experience in both numerical simulations and experimental methods through cross-discipline collaborations. Following the introduction to the TRUST project, the remainder of this report focuses on experimental and analytical efforts conducted in Fiscal Year (FY) 2024 relevant to the TRUST Contact Thermal Conductance (CTC) testbed.

42 ENGINEERING↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Fiber optic sensing system for grid-based assets

A sensor system includes a sensor network comprising at least one optical fiber having one or more optical sensors. At least one of the optical sensors is arranged to sense vibration of an electrical device and to produce a time variation in light output in response to the vibration. A detector generates an electrical time domain signal in response to the time variation in light output. An analyzer acquires a snapshot frequency component signal which comprises one or more time varying signals of frequency components of the time domain signal over a data acquisition time period. The analyzer detects a condition of the electrical device based on the snapshot frequency component signal.

Kiesel, Peter↗

Fiber optic sensing system for grid-based assets

A sensor system includes a sensor network comprising at least one optical fiber having one or more optical sensors. At least one of the optical sensors is arranged to sense vibration of an electrical device and to produce a time variation in light output in response to the vibration. A detector generates an electrical time domain signal in response to the time variation in light output. An analyzer acquires a snapshot frequency component signal which comprises one or more time varying signals of frequency components of the time domain signal over a data acquisition time period. The analyzer detects a condition of the electrical device based on the snapshot frequency component signal.

Kiesel, Peter↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Glass Additive and Subtractive Manufacturing of a Fiber Optic Rotary Encoder for Downhole Pressure Sensing

This article presents a fiber optic rotary encoder-based pressure sensor for downhole applications. The rotary encoder, which is composed of an encoding pad and an all-glass optical fiber sensing head, converts the rotation angles of a pressure transducer to digital codes. The optical fiber only serves as the telemetry channel to directly transmit the data in digital format such that the environmental temperature influence and the long-time drift are minimized. The glass additive and subtractive manufacturing (ASM) techniques are used to embed the multichannel optical fibers into a bulk-fused silica glass substrate. Because the fused silica glass shares a similar material property to the optical fiber (e.g., thermal expansion coefficient), the optical fiber sensing head is well sealed and fixed even at an elevated temperature. The picosecond laser blackening technique is used to fabricate the high reflectivity contrast encoding pad with high accuracy. Here, the proposed pressure sensor was manufactured and experimentally verified to have a signal-to-noise ratio (SNR) of 23 dB and a linear pressure response with a root-mean-square error (RMSE) of 0.37. During the 400-h 250 °C long-term stability test, there was no digital code variation. In addition, a mathematical model to study the relationships between the sensor’s performances and design parameters was established. According to the model, a 12-bit encoder (0.02% pressure sensitivity) can be achieved with a radius of 20 mm.

02 PETROLEUM↗

Integrating Radio-Over-Fiber Communication System and BOTDR Sensor System

In this paper, we propose and experimentally demonstrate for the first time, the integration of a radio-over-fiber (RoF) communication system and a Brillouin optical time-domain reflectometry (BOTDR) distributed sensor system using a single optical fiber link. In this proof-of-concept integrated system, the communication system is composed of three modulation formats of quadrature phase-shift keying (QPSK), 16-quadrature amplitude modulation (16-QAM) and 64-QAM, which are modulated onto an orthogonal frequency division multiplexing (OFDM) signal. Whereas, the BOTDR sensor system is used for strain and/or temperature monitoring over the fiber distance with a spatial resolution of 5 m using a 25 km single-mode silica fiber. The error vector magnitude (EVM) is analyzed in three modulation formats in the presence of various BOTDR input pump powers. Using QPSK modulation, optimized 18 dBm sensing and 10 dBm data power, the measured EVM values with and without bandpass filter are 3.5% and 14.5%, respectively. The proposed system demonstrates a low temperature measurement error (±0.49 °C at the end of 25 km) and acceptable EVM values, which were within the 3GPP requirements. The proposed integrated system can be effectively applied for practical applications, which significantly reduces the fiber infrastructure cost by effective usage of a single optical fiber link.

42 ENGINEERING↗

Liquid Core Detection and Strand Condition Monitoring in a Continuous Caster Using Optical Fiber

Real-time monitoring of the liquid core position during the continuous casting of steel has been demonstrated using low-cost distributed optical-fiber-based strain sensors. These sensors were installed on the containment roll support structures in the segments of a production continuous caster to detect the position of the solid–liquid interface and monitor the strand condition during the continuous casting. Distributed Fiber Bragg Grating sensors (FBGs) were used in this work to monitor strain at six roll positions in the caster. The sensor performance was first validated by comparing optical strain measurements with conventional strain gauge measurements in the lab. Next, optical strain measurements were performed on an isolated caster segment in a segment maintenance facility using hydraulic jacks to simulate the presence of a liquid core under the roll. Finally, the sensors were evaluated during caster operation. The sensors successfully detected the load increase associated with the presence of a liquid core under each instrumented roll location. Incidents of bulging and roll eccentricity were also detected using frequency analysis of the optical strain signal. The liquid core position measurements were compared using predictions from computer models (digital twins) in use at the production site. The measurements were in good agreement with the model predictions, with a few exceptions. Under certain transient caster operating conditions, such as spraying practice changes and SEN exchanges, the model predictions deviated slightly from the liquid core position determined from strain measurements.

47 OTHER INSTRUMENTATION↗

Comparison of Surface Phenomena Created by Underground Chemical Explosions in Dry Alluvium and Granite Geology From Fully Polarimetric VideoSAR Data

Phase I of the Source Physics Experiment (SPE) series involved six underground chemical explosions, all of which were conducted at the same experimental pad. Research from the sixth explosion of the series (SPE-6) demonstrated that polarimetric synthetic aperture radar (PolSAR) is a viable technology for monitoring an underground chemical explosion when the geologic structure is Cretaceous granitic intrusive. It was shown that a durable signal is measurable by the H/A/α polarimetric decomposition parameters. After the SPE-6 experiment, the SPE program moved to the Phase II location, which is composed of dry alluvium geology (DAG). The loss of wavefront energy is greater through dry alluvium than through granite. In this article, we compare the SPE-6 analysis to the second DAG (DAG-2) experiment. We hypothesize that despite the geology at the DAG site being more challenging than at the Phase I location, combined with the DAG-2 experiment having a 3.37 times deeper scaled depth of burial than the SPE-6, a durable nonprompt signal is still measurable by a PolSAR sensor. We compare the PolSAR time-series measures from videoSAR frames, from the SPE-6 and DAG-2 experiments, with accelerometer data. We show which PolSAR measures are invariant to the two types of geology and which are geology dependent. We compare a coherent change detection (CCD) map from the DAG-2 experiment with the data from a fiber-optic distributed acoustic sensor to show the connection between the spatial extent of coherence loss in CCD maps and spallation caused by the explosion. Finally, we also analyze the spatial extent of the PolSAR measures from both explosions.

42 ENGINEERING↗

Active Compensation of Radiation Effects on Optical Fibers for Sensing Applications

Neutron and gamma irradiation is known to compact silica, resulting in macroscopic changes in refractive index (RI) and geometric structure. The change in RI and linear compaction in a radiation environment is caused by three well-known mechanisms: (i) radiation-induced attenuation (RIA), (ii) radiation-induced compaction (RIC), and (iii) radiation-induced emission (RIE). These macroscopic changes induce errors in monitoring physical parameters such as temperature, pressure, and strain in optical fiber-based sensors, which limit their application in radiation environments. We present a cascaded Fabry–Perot interferometer (FPI) technique to measure macroscopic properties, such as radiation-induced change in RI and length compaction in real time to actively account for sensor drift. The proposed cascaded FPI consists of two cavities: the first cavity is an air cavity, and the second is a silica cavity. The length compaction from the air cavity is used to deduce the RI change within the silica cavity. We utilize fast Fourier transform (FFT) algorithm and two bandpass filters for the signal extraction of each cavity. Inclusion of such a simple cascaded FPI structure will enable accurate determination of physical parameters under the test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inference of Induced Fracture Geometries Using Fiber-Optic Distributed Strain Sensing in Hydraulic Fracture Test Site 2

Fiber-optic Distributed Strain Sensor observations in a vertical well allow rapid inference of the time evolution of nearby hydraulic fracture heights and their vertical aperture distributions during stimulation and depressurization. We describe a computationally efficient deconvolutional model based on an elastostatic kernel for fracture opening within an isotropic, homogeneous, linear elastic medium. Furthermore, an application of this model to observations from the Hydraulic Fracture Test Site 2 reveals that ultimate fracture heights are typically greater than those indicated by microseismic monitoring, and some hydraulic fractures continue their upward growth for several hours after high-pressure injections ceased.

58 GEOSCIENCES↗

Accurate Monitoring of an Electrically Energized Casing Source using Fiber Optic Sensing

This report summarizes an investigation of utilizing a Piezoelectric coating on fiber optics to monitor electric fields. The application of interest was monitoring the electric field emitted from a borehole casing being used an an Electromagnetic source in geophysical monitoring. Testing consists of using a water filled vessel with plate electrodes on opposing sides to generate electric fields while lowering a custom designed sensor into the water. The results are compared to what is conventionally available via simulations.

03 NATURAL GAS↗