Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Non-perturbative cathodoluminescence microscopy of beam-sensitive materials

Cathodoluminescence microscopy is now a wellestablished and powerful tool for probing the photonic properties of nanoscale materials, but in many cases, nanophotonic materials are easily damaged by the electronbeam doses necessary to achieve reasonable cathodoluminescence signal-to-noise ratios. Two-dimensional materials have proven particularly susceptible to beam-induced modifications, yielding both obstacles to high spatial-resolution measurement and opportunities for beam-induced patterning of quantum photonic systems. Here pan-sharpening techniques are applied to cathodoluminescence microscopy in order to address these challenges and experimentally demonstrate the promise of pan-sharpening for minimally-perturbative high-spatial-resolution spectrum imaging of beam-sensitive materials.

2D materials↗

Adaptation of ion beam technology to microfabrication of solid state devices and transducers

A number of areas were investigated to determine the potential uses of ion beam techniques in the construction of solid state devices and transducers and the packaging of implantable electronics for biomedical applications. The five areas investigated during the past year were: (1) diode-like devices fabricated on textured silicon; (2) a photolithographic technique for patterning ion beam sputtered PVC (polyvinyl chloride); (3) use of sputtered Teflon as a protective coating for implantable pressure sensors; (4) the sputtering of Macor to seal implantable hybrid circuits; and (5) the use of sputtered Teflon to immobilize enzymes.

Topich, J. A.↗

Magnetic strip patterns induced by focused ion beam irradiation

Focused ion beam exposure was used to locally alter the magnetic properties of a continuous Co/Pd multilayer film with perpendicular magnetic anisotropy. The saturation magnetization, coercivity, and magnetic anisotropy of the films can be tuned by Ga irradiation depending on exposure dose. As a result, a periodic strip pattern consisting of 80 nm wide exposed strips which are magnetically soft, separated by 170 nm wide magnetically hard, unexposed areas was created. Due to strong magnetostatic coupling between the strips, a number of magnetic domain configurations could be stabilized and these have been observed by magnetic force microscopy and magneto-optic Kerr effect measurements. The magnetic domain configurations and their reversal behavior were investigated by micromagnetic simulations as a function of exposure dose and strip period.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and characterization of a W‐band wide‐beam horn for radio holography

Abstract A W‐band wide‐beam horn suitable for prime‐focus feed is described in this paper. It was designed to provide better illuminations for outer panels of larger reflector antennas and to improve performance of radio holography systems. Much effort has been spent on precise characterization of the amplitude and phase patterns of the wide beam horn which has a direct impact on the measurement accuracy of the radio holography. A far‐field measurement setup with the correction of phase errors due to cable flexing has been developed. Good beam pattern agreement has been achieved between simulation and measurement.

Zhang, Xiaoling↗

Mandrels For Microtextured Small-Vessel Implants

Research shows artificial blood-vessel and heart-valve implants made more compatible with their biological environments by use of regularly microtextured surfaces. In new manufacturing process, ion beam etches patterned array of small pillars on mandrel used to mold tubular plastic implant. Pillars create tiny regularly spaced holes in inner surface of tube. Holes expected to provide sites for attachment of healthy lining. Polytetrafluoroethylene (PTFE) used as mandrel material because it can be etched by ion beam.

Deininger, William D.↗

One-Dimensional Photonic Crystal Superprisms

Theoretical calculations indicate that it should be possible for one-dimensional (1D) photonic crystals (see figure) to exhibit giant dispersions known as the superprism effect. Previously, three-dimensional (3D) photonic crystal superprisms have demonstrated strong wavelength dispersion - about 500 times that of conventional prisms and diffraction gratings. Unlike diffraction gratings, superprisms do not exhibit zero-order transmission or higher-order diffraction, thereby eliminating cross-talk problems. However, the fabrication of these 3D photonic crystals requires complex electron-beam substrate patterning and multilayer thin-film sputtering processes. The proposed 1D superprism is much simpler in structural complexity and, therefore, easier to design and fabricate. Like their 3D counterparts, the 1D superprisms can exhibit giant dispersions over small spectral bands that can be tailored by judicious structure design and tuned by varying incident beam direction. Potential applications include miniature gas-sensing devices.

Ting, David↗

One-Dimensional Scanning Approach to Shock Sensing

Measurement tools for high speed air flow are sought both in industry and academia. Particular interest is shown in air flows that exhibit aerodynamic shocks. Shocks are accompanied by sudden changes in density, pressure, and temperature. Optical detection and characterization of such shocks can be difficult because the medium is normally transparent air. A variety of techniques to analyze these flows are available, but they often require large windows and optical components as in the case of Schlieren measurements and/or large operating powers which precludes their use for in-flight monitoring and applications. The one-dimensional scanning approach in this work is a compact low power technique that can be used to non-intrusively detect shocks. The shock is detected by analyzing the optical pattern generated by a small diameter laser beam as it passes through the shock. The optical properties of a shock result in diffraction and spreading of the beam as well as interference fringes. To investigate the feasibility of this technique a shock is simulated by a 426 m diameter optical fiber. Analysis of results revealed a direct correlation between the optical fiber or shock location and the beam s diffraction pattern. A plot of the width of the diffraction pattern vs. optical fiber location reveals that the width of the diffraction pattern was maximized when the laser beam is directed at the center of the optical fiber. This work indicates that the one-dimensional scanning approach may be able to determine the location of an actual shock. Near and far field effects associated with a small diameter laser beam striking an optical fiber used as a simulated shock are investigated allowing a proper one-dimensional scanning beam technique.

Tokars, Roger↗

Chapter 19B - Antenna Radiation Patterns

Modern civil and military aircraft are equipped with a variety of communication devices, radio navigation equipment, and air traffic control systems. For all of these devices appropriate antennas must be available to transmit and receive the signals. As a result, as many as 30 antennas, and sometimes even more, are mounted around today's aircraft. For this reason, it is necessary to know the capabilities of the receiving/transmitting equipment on board. These capabilities are driven by the antenna characteristics. Therefore, coverage, shading, and beam pointing pattern data are necessary for optimum electronic coverage. The aircraft antenna has to convert the available power density of the electromagnetic field to an electric voltage at its connector. This voltage level must be sufficiently high to operate the connected equipment. The reciprocity principle states that it makes no difference if the antenna is receiving or transmitting. For the certification of the aircraft antennas it must be proven that the antennas are at least generating the minimum receiver input voltage which is required for each radio service. The prime condition is, of course, that the specified field power densities of the different radio navigation and communication services are available. An important property of a radio frequency link is the electro-magnetic field intensity at every point in space for a given output power of the antenna. As the propagation of radio frequency waves in free space is well known, the spatial distribution of the field intensity needs only be measured at one spatial sphere around the antenna. The information is usually given as distributions along the circumference of flat sections through this sphere: each of these is called an ARP. Several ARPs are usually required to describe the complete spatial antenna pattern of an antenna. In addition to mathematical modeling, measurements on sub-scale models, and static measurements on full size models or aircraft on the ground, dynamic measurements on aircraft in flight play the most important role in the aircraft antenna testing and certification. [19B-1] The shape of an ARP, for one given frequency, is determined by the shape of the antenna and the shape and material of the surface it is mounted on. As the directly transmitted waves interfere with waves reflected by the aircraft skin with its complex geometry, and the surface material parameters are only roughly known, it is not possible to predict the ARP with the required accuracy. In ground measurements the earth's surface also acts as a reflector thereby causing the ground ARP to be different from the in-flight ARP. As the in-flight ARP is the ARP we are actually interested in it becomes clear that it is necessary to conduct in-flight ARP measurements. The Flight Test Engineer must be aware of the needs of the specialists who are establishing the test program for measuring antenna patterns and radar cross sections. These tests will require special test equipment and dedicated flights to obtain the data that they require. This Section provides an introduction to the principles of determining antenna patterns and the flight techniques for determining both antenna patterns and radar cross section. Reference 19B-1 provides detailed information.

Helmut Bothe↗

Real-time analysis keratometer

A computer assisted keratometer in which a fiducial line pattern reticle illuminated by CW or pulsed laser light is projected on a corneal surface through lenses, a prismoidal beamsplitter quarterwave plate, and objective optics. The reticle surface is curved as a conjugate of an ideal corneal curvature. The fiducial image reflected from the cornea undergoes a polarization shift through the quarterwave plate and beamsplitter whereby the projected and reflected beams are separated and directed orthogonally. The reflected beam fiducial pattern forms a moire pattern with a replica of the first recticle. This moire pattern contains transverse aberration due to differences in curvature between the cornea and the ideal corneal curvature. The moire pattern is analyzed in real time by computer which displays either the CW moire pattern or a pulsed mode analysis of the transverse aberration of the cornea under observation, in real time. With the eye focused on a plurality of fixation points in succession, a survey of the entire corneal topography is made and a contour map or three dimensional plot of the cornea can be made as a computer readout in addition to corneal radius and refractive power analysis.

Adachi, Iwao P.↗

Evolution of solidification texture during additive manufacturing

Striking differences in the solidification textures of a nickel based alloy owing to changes in laser scanning pattern during additive manufacturing are examined based on theory and experimental data. Understanding and controlling texture are important because it affects mechanical and chemical properties. Solidification texture depends on the local heat flow directions and competitive grain growth in one of the six <100> preferred growth directions in face centered cubic alloys. Furthermore, the heat flow directions are examined for various laser beam scanning patterns based on numerical modeling of heat transfer and fluid flow in three dimensions. Here we show that numerical modeling can not only provide a deeper understanding of the solidification growth patterns during the additive manufacturing, it also serves as a basis for customizing solidification textures which are important for properties and performance of components.

36 MATERIALS SCIENCE↗

Advancing next generation nanolithography with infiltration synthesis of hybrid nanocomposite resists

Organic–inorganic hybrid resists are emerging as an effective way of addressing stringent process requirements for aggressive down-scaling of semiconducting devices. Yet, hybrid resists generally require complex chemical synthesis while being predominantly negative-tone with high dose requirements. For positive-tone processes and high-aspect-ratio pattern transfers, resist choices are limited to costly, non-hybrid alternatives, whose etch resistance is still inferior compared with hybrid resists. In this work, we demonstrate a novel hybrid positive-tone resist platform utilizing simple ex situ vapor-phase inorganic infiltration into standard resist materials. A model system based on poly(methyl methacrylate) (PMMA) thin film hybridized with aluminum oxide has been demonstrated for electron-beam lithography patterning, featuring a fully controllable critical exposure dose, contrast, and etch resistance. The hybrid resist not only achieves contrast as high as ~30, six-fold enhancement over standard PMMA, but also enables Si nanostructures with resolution down to ~30 nm and an aspect ratio as high as ~17, owing to enhancement of the Si etch selectivity to ~70, with an estimated achievable maximum of ~300, far exceeding known commercial positive-tone resist systems. The easy implementabilility, combined with versatile ex situ control of resist characteristics, makes this hybrid resist synthesis method uniquely suited for addressing the resist performance and high throughput required for advanced nanolithography techniques, such as extreme ultraviolet lithography, possibly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-E-T-562: Scanned Percent Depth Dose Curve Discrepancy for Photon Beams with Physical Wedge in Place (Varian IX) Using Different Sensitive Volume Ion Chambers

Purpose: To investigate and report the discrepancy of scanned percent depth dose (PDD) for photon beams with physical wedge in place when using ion chambers with different sensitive volumes. Methods/Materials: PDD curves of open fields and physical wedged fields (15, 30, 45, and 60 degree wedge) were scanned for photon beams (6MV and 10MV, Varian iX) with field size of 5x5 and 10x10 cm using three common scanning chambers with different sensitive volumes - PTW30013 (0.6cm3), PTW23323 (0.1cm3) and Exradin A16 (0.007cm3). The scanning system software used was OmniPro version 6.2, and the scanning water tank was the Scanditronix Wellhoffer RFA 300.The PDD curves from the three chambers were compared. Results: Scanned PDD curves of the same energy beams for open fields were almost identical between three chambers, but the wedged fields showed non-trivial differences. The largest differences were observed between chamber PTW30013 and Exradin A16. The differences increased as physical wedge angle increased. The differences also increased with depth, and were more pronounced for 6MV beam. Similar patterns were shown for both 5x5 and 10x10 cm field sizes. For open fields, all PDD values agreed with each other within 1% at 10cm depth and within 1.62% at 20 cm depth. For wedged fields, the difference of PDD values between PTW30013 and A16 reached 4.09% at 10cm depth, and 5.97% at 20 cm depth for 6MV with 60 degree physical wedge. Conclusion: We observed a significant difference in scanned PDD curves of photon beams with physical wedge in place obtained when using different sensitive volume ion chambers. The PDD curves scanned with the smallest sensitive volume ion chamber showed significant difference from larger chamber results, beyond 10cm depth. We believe this to be caused by varying response to beam hardening by the wedges.

07 ISOTOPE AND RADIATION SOURCES↗

Shape transitions and island nucleation for Si/Ge molecular beam epitaxy on stripe-patterned Si (001) substrate

Si and Ge growth on the stripe patterned Si (001) substrates is studied using scanning tunneling microscopy. During Si buffer growth, the stripe morphology rapidly evolves from multifaceted ''U'' to ''V''-shaped forms. This involves successive transitions between different low energy (11n) side facets, where n continuously decreases from n=3 to 20. Ge growth on such stripes induces the formation of a pronounced side wall ripple structure when the Ge thickness exceeds three monolayers. This ripple structure consists of alternating (105) microfacets oriented perpendicularly to the stripes. Depending of the side wall geometry, Ge nanoislands subsequently nucleate either on the side walls or at the bottom of grooves. The latter only occurs for ''V''-shaped stripes, where the side wall ripples extend all the way from the top to the bottom of the grooves, allowing efficient downward mass transport. For multifaceted ''U'' stripes, the side wall ripples are interrupted by steeper side wall segments such that mounds and subsequently, pyramids and domes grow on the side walls instead of at the bottom of the grooves. The island shapes strongly depend on their position on the pattern topography, which also affects the critical coverage for island nucleation as well as for the transition from pyramids to domes. The mechanisms for nucleation at different positions are clarified by detailed analysis and the role of kinetic as well as energetic factors identified.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Asymptotic theory of ponderomotive dynamics of an electron in the field of a focused relativistically intense electromagnetic envelope

Based on a formal asymptotic solution of Maxwell’s equations for a field propagating in a vacuum and of the relativistic Newton equation for an electron driven by the corresponding Lorentz force, we construct a description of the relativistic ponderomotive dynamics of an electron in the field of an intense focused electromagnetic envelope. A small parameter for the asymptotic expansion is proportional to the ratio of the radiation wavelength to the focal spot radius. Using the obtained averaged model of ponderomotive dynamics, electron beam scattering patterns are plotted with regard to an angle relative to the electromagnetic field propagation axis for laser pulses with a Gaussian transverse intensity distribution, as well as the energy spectra of scattered electrons corresponding to individual ranges of this angle. Scattered particles are absent in some ranges of the polar angle. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal imaging diagnostics of high-current electron beams

The thermal imaging diagnostics of measuring pulsed electron beam energy density is presented. It provides control of the electron energy spectrum and a measure of the density distribution of the electron beam cross section, the spatial distribution of electrons with energies in the selected range, and the total energy of the electron beam. The diagnostics is based on the thermal imager registration of the imaging electron beam thermal print in a material with low bulk density and low thermal conductivity. Testing of the thermal imaging diagnostics has been conducted on a pulsed electron accelerator TEU-500. The energy of the electrons was 300-500 keV, the density of the electron current was 0.1-0.4 kA/cm{sup 2}, the duration of the pulse (at half-height) was 60 ns, and the energy in the pulse was up to 100 J. To register the thermal print, a thermal imager Fluke-Ti10 was used. Testing showed that the sensitivity of a typical thermal imager provides the registration of a pulsed electron beam heat pattern within one pulse with energy density over 0.1 J/cm{sup 2} (or with current density over 10 A/cm{sup 2}, pulse duration of 60 ns and electron energy of 400 keV) with the spatial resolution of 0.9-1 mm. In contrast to the method of using radiosensitive (dosimetric) materials, thermal imaging diagnostics does not require either expensive consumables, or plenty of processing time.

43 PARTICLE ACCELERATORS↗

Magnetic domain wall manipulation in (Ga,Mn)As nanostructures for spintronic applications

Ring-shaped nanostructures have been designed and fabricated by electron-beam lithography patterning and chemical etching from thin epitaxial layers of the ferromagnetic semiconductor (Ga,Mn)As. The nanostructures, in a form of planar rings with a slit, were supplied with four electrical terminals and subjected to magneto-transport studies under planar weak magnetic field. Magnetoresistive effects caused by manipulation of magnetic domain walls and magnetization reversal in the nanostructures have been investigated and possible applications of the nanostructures as four-terminal spintronic devices are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

External Beam Radiotherapy for Colon Cancer: Patterns of Care

Purpose: Despite its common and well characterized use in other gastrointestinal malignancies, little is known about radiotherapy (RT) use in nonmetastatic colon cancer in the United States. To address the paucity of data regarding RT use in colon cancer management, we examined the RT patterns of care in this patient population. Methods and Materials: Patients with nonmetastatic colon cancer, diagnosed between 1988 and 2005, were identified in the Surveillance, Epidemiology, and End Results (SEER) database. Univariate and multivariate methods were used to identify factors associated with RT use. Results: On univariate analysis, tumor location, age, sex, race, T stage, N stage, and geographic location were each associated with differences in RT use (all p < 0.01). In general, younger patients, male patients, and patients with more advanced disease were more likely to receive RT. On multivariate analysis, tumor location, age, gender, T and N stage, time of diagnosis and geographic location were significantly associated with RT use (all p < 0.001). Race, however, was not associated with RT use. On multivariate analysis, patients diagnosed in 1988 were 2.5 times more likely to receive RT than those diagnosed in 2005 (p = 0.001). Temporal changes in RT use reflect a responsiveness to evolving evidence related to the therapeutic benefits of adjuvant RT. Conclusions: External beam RT is infrequently used for colon cancer, and its use varies according to patient and tumor characteristics. RT use has declined markedly since the late 1980s; however, it continues to be used for nonmetastatic disease in a highly individualized manner.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ferromagnetic (Ga,Mn)As nanostructures for spintronic applications

Magneto-resistive, cross-like nanostructures have been designed and fabricated by electron-beam lithography patterning and chemical etching from thin epitaxial layers of the ferromagnetic semiconductor (Ga,Mn)As. The nanostructures, composed of two perpendicular nanostripes crossing in the middle of their length, represent four-terminal devices, in which an electric current can be driven through any of the two nanostripes. In these devices, a novel magneto-resistive memory effect, related to a rearrangement of magnetic domain walls in the central part of the device, has been demonstrated. It consists in that the zero-field resistance of a nanostripe depends on the direction of previously applied magnetic field. The nanostructures can thus work as two-state devices providing basic elements of nonvolatile memory cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗