Search NASA⌕ Search

SEARCH · Search NASA

Results for “reverse current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

An Active Broad Area Cooling Model of a Cryogenic Propellant Tank with a Single Stage Reverse Turbo-Brayton Cycle Cryocooler

As focus shifts towards long-duration space exploration missions, an increased interest in active thermal control of cryogenic propellants to achieve zero boil-off of cryogens has emerged. An active thermal control concept of considerable merit is the integration of a broad area cooling system for a cryogenic propellant tank with a combined cryocooler and circulator system that can be used to reduce or even eliminate liquid cryogen boil-off. One prospective cryocooler and circulator combination is the reverse turbo-Brayton cycle cryocooler. This system is unique in that it has the ability to both cool and circulate the coolant gas efficiently in the same loop as the broad area cooling lines, allowing for a single cooling gas loop, with the primary heat rejection occurring by way of a radiator and/or aftercooler. Currently few modeling tools exist that can size and characterize an integrated reverse turbo-Brayton cycle cryocooler in combination with a broad area cooling design. This paper addresses efforts to create such a tool to assist in gaining a broader understanding of these systems, and investigate their performance in potential space missions. The model uses conventional engineering and thermodynamic relationships to predict the preliminary design parameters, including input power requirements, pressure drops, flow rate, cycle performance, cooling lift, broad area cooler line sizing, and component operating temperatures and pressures given the cooling load operating temperature, heat rejection temperature, compressor inlet pressure, compressor rotational speed, and cryogenic tank geometry. In addition, the model allows for the preliminary design analysis of the broad area cooling tubing, to determine the effect of tube sizing on the reverse turbo-Brayton cycle system performance. At the time this paper was written, the model was verified to match existing theoretical documentation within a reasonable margin. While further experimental data is needed for full validation, this tool has already made significant steps towards giving a clearer understanding of the performance of a reverse turbo-Brayton cycle cryocooler integrated with broad area cooling technology for zero boil-off active thermal control.

Guzik, Monica C.↗

New process produces high-power Schottky diodes

Processing procedure using low-temperature platinum silicide, results in successful high-yield fabrication of large-area mesa-geometry Schottky diodes, with reverse breakdown voltages as high as 150 volts and leak currents less than 5 milliamps at 212 F.

Cordes, L. F.↗

Apparatus for electrohydrodynamically assembling patterned colloidal structures

A method apparatus is provided for electrophoretically depositing particles onto an electrode, and electrohydrodynamically assembling the particles into crystalline structures. Specifically, the present method and apparatus creates a current flowing through a solution to cause identically charged electrophoretically deposited colloidal particles to attract each other over very large distances (<5 particle diameters) on the surface of electrodes to form two-dimensional colloidal crystals. The attractive force can be created with both DC and AC fields and can modulated by adjusting either the field strength or frequency of the current. Modulating this lateral attraction between the particles causes the reversible formation of two-dimensional fluid and crystalline colloidal states on the electrode surface. Further manipulation allows for the formation of two or three-dimensional colloidal crystals, as well as more complex designed structures. Once the required structures are formed, these three-dimension colloidal crystals can be permanently frozen or glued by controlled coagulation induced by to the applied field to form a stable crystalline structure.

Trau, Mathias↗

Method for electrohydrodynamically assembling patterned colloidal structures

A method apparatus is provided for electrophoretically depositing particles onto an electrode, and electrohydrodynamically assembling the particles into crystalline structures. Specifically, the present method and apparatus creates a current flowing through a solution to cause identically charged electrophoretically deposited colloidal particles to attract each other over very large distances (<5 particle diameters) on the surface of electrodes to form two-dimensional colloidal crystals. The attractive force can be created with both DC and AC fields and can modulated by adjusting either the field strength or frequency of the current. Modulating this lateral attraction between the particles causes the reversible formation of two-dimensional fluid and crystalline colloidal states on the electrode surface. Further manipulation allows for the formation of two or three-dimensional colloidal crystals, as well as more complex designed structures. Once the required structures are formed, these three-dimension colloidal crystals can be permanently frozen or glued by controlled coagulation induced by to the applied field to form a stable crystalline structure.

Trau, Mathias↗

Reverse bias protected solar array with integrated bypass battery

A method for protecting the photovoltaic cells in a photovoltaic (PV) array from reverse bias damage by utilizing a rechargeable battery for bypassing current from a shaded photovoltaic cell or group of cells, avoiding the need for a bypass diode. Further, the method mitigates the voltage degradation of a PV array caused by shaded cells.

Landis, Geoffrey A↗

Galvanic Vestibular Reduction Modifies Perception of Coriolis Cross-Coupling and Delays Motion Sickness Onset

INTRODUCTION: Alterations in vestibular sensory processing following G-transitions lead to head movement sensitivity and motion sickness upon return to Earth’s gravity. The purpose of this study was to evaluate whether a non-pharmaceutical tool using galvanic vestibular reduction (GVR) could suppress disorienting illusions and mitigate motion sickness. A similar approach using anodal (inhibitory) currents delivered to both ears has been shown to result in a selective reversible ablation of irregular vestibular afferents [1]. METHODS: Using a repeated measures counter-balanced design, motion sickness and perception were obtained in 26 subjects during Coriolis cross-coupling stimuli on a rotating chair across three GVR treatment interventions: throughout stimulus testing (prevention), following symptom onset (rescue), and placebo control. The GVR peak current was maintained at 2.5 mA across subjects and across prevention / rescue sessions. Subjects performed up to 10 sets of pitch head movements during constant rotation. For each set, head movement was cued every 10 seconds, alternating between pitch forward (chin resting to chest) and pitch backward (head upright) for a total of 7 forward and backward movements. During each head movement, subjects were asked to use a joystick to record the magnitude of their perceived rotation along three axes. During the 2-minute pause between sets, motion sickness symptom scoring was obtained using the Pensacola Diagnostic Index and subject discomfort (0-20) ratings. Performance on a sensorimotor and cognitive test battery was measured during a fourth session to map changes in GVR level with functional performance. RESULTS: Fourteen of the 26 subjects were not susceptible to the motion stressor (i.e., did not reach an endpoint in the control condition). While the time to endpoint, or number of head movements, did not significantly vary across the three GVR conditions in the remaining subjects, the symptom levels were significantly lower through the third set of head movements when GVR was on throughout the testing. Initiating GVR following symptom onset did not appear to alter the symptom progression nor time to motion sickness endpoint. Based on the joystick measures, GVR significantly modified the perceived roll and pitch sensation during head movements, reducing the amplitude of tilt in most subjects. It is important to note that comparable levels of GVR did not impair performance on a functional test battery including mobility, balance and cognitive tasks. DISCUSSION: Our findings suggest GVR may be useful in reducing disorienting roll and pitch illusions and delaying the onset of motion sickness. Further enhancements will be required to individualize the stimulation amplitude and optimize the waveform delivery. Adapting this non-pharmaceutical countermeasure approach to allow self-administered titration of current amplitude during recovery would enable transfer to post-flight treatment of motion sickness. [1] Minor L. B. and Goldberg J. M. (1991) J Neurosci 11, 1636-48. 109, 889-894.

G N Pradhan↗

Investigation from Japanese MAGSAT Team. Part A. Crustal structure near Japan and in Antarctic station. Part B. Electric currents and hydromagnetic waves in the ionosphere and the magnetosphere

Preliminary results of MAGSAT data analysis are described. Regional anomaly maps (deviations from the MGST model field) for X,Y,Z, and F in the area of 115 to 155 deg E and 20 to 60 deg N were obtained. A similar map for the geomagnetic total force anomaly in the vicinity of Japan showed that the observed anomaly can be explained by the difference in crustal magnetization between the Japan Sea and the Japan Island, which reflects a difference of 25 km in the thickness of the magnetized layer. The MAGSAT record of a sudden commencement of a magnetic storm above the South Atlantic Ocean showed a reverse impulse particularly in the D-component. Results relating to toroidal currents in the ionosphere, transverse and parallel perturbations over the polar regions, the relationship between field aligned currents and precipitating electrons, and the calculation of the subsatellite electric field are also discussed.

Fukushima, N.↗

Current sheet crossings in the distant magnetotail

A computer search of crossings of the field reversal region in the middle of the distant magnetotail has been done with ISEE-3 data. It is found that the instantaneous direction of the magnetic field at the crossings Bz is northward on average at a distance of 220 earth radii, with moderate values of the plasma flow. This result suggests that the magnetic field lines are closed; since the flow is tailward, the Dungey (1961) model with a steady state reconnection line across the magnetotail earthward of the spacecraft is invalidated. The present result gives strong support to a model in which tailward boundary layer flow provides the viscous interaction proposed by Axford and Hines (1961). At higher values of the plasma velocity, negative values of Bz are found.

Heikkila, W. J.↗

The electrochemical generation of useful chemical species from lunar materials

The current status of work on an electrochemical technology for the simultaneous generation of oxygen and lithium from a Li2O containing molten salt (Li2O-LiCl-LiF) is discussed. The electrochemical cell utilizes an oxygen vacancy conducting solid electrolyte, yttria-stabilized zirconia, to effect separation between the oxygen evolving and lithium reduction half-cell reactions. The cell, which operates at 700 to 800 C, possesses rapid electrode kinetics at the lithium-alloy electrode with exchange current density values being greater than 60 mA/sq cm, showing high reversibility for this reaction. When used in the electrolytic mode, lithium produced at the negative electrode would be continuously removed from the cell for later use (under lunar conditions) as an easily storable reducting agent (compared to H2) for the chemical refining of lunar ores via the general reaction: 2Li + MO yields Li2O + M where MO represents a lunar ore. Emphasis to this time has been on the simulated lunar ore ilmenite (FeTiO3), which we have found becomes chemically reduced by Li at 432 C. Furthermore, both Fe2O3 and TiO2 have been reduced by Li to give the corresponding metal. This electrochemical approach provides a convenient route for producing metals under lunar conditions and oxygen for the continuous maintenance of human habitats on the Moon's surface. Because of the high reversibility of this electrochemical system, it has also formed the basis for the lithium-oxygen secondary battery. This secondary lithium-oxygen battery system posses the highest theoretical energy density yet investigated.

Tsai, Kan J.↗

Inertial currents in isotropic plasma

The magnetospheric convection electric field contributes to Birkeland currents. The effects of the field are to polarize the plasma by displacing the bounce paths of the ions from those of electrons, to redistribute the pressure so that it is not constant along magnetic field lines, and to enhance the pressure gradient by the gradient of the bulk speed. Changes in the polarization charge during the convection of the plasma are neutralized by electrons in the form of field-aligned currents that close through the ionosphere. The pressure drives field-aligned currents through its gradient in the same manner as in quasi-static plasma, but with modifications that are important if the bulk speed is of the order of the ion thermal speed; the variations in the pressure along field lines are maintained by a weak parallel potential drop. These effects are described in terms of the field-aligned currents in steady state, isotropic, magnetohyrodynamic (MHD) plasma. Solutions are developed by taking the MHD limit of two-fluid solutions and illustrated in the special case of Maxwellian plasma for which the temperature is constant along magnetic field lines. The expression for the Birkeland current density is a generalization of Vasyliunas' expression for the field-aligned current density in quasi-static plasma and provides a unifying expression when both pressure gradients and ion inertia operate simultaneously as sources of field-aligned currents. It contains a full account of different aspects of the ion flow (parallel and perpendicular velocity and vorticity) that contribute to the currents. Contributions of ion inertia to field-aligned currents will occur in regions of strong velocity shear, electric field reversal, or large gradients in the parallel velocity or number density, and may be important in the low-latitude boundary layer, plasma sheet boundary layer, and the inner edge region of the plasma sheet.

Heinemann, M.↗

Inertial currents in isotropic plasma

The magnetospheric convection electric field contributes to Birkeland currents. The effects of the field are to polarize the plasma by displacing the bounce paths of the ions from those of electrons, to redistribute the pressure so that it is not constant along magnetic field lines, and to enhance the pressure gradient by the gradient of the bulk speed. Changes in the polarization charge during the convection of the plasma are neutralized by electrons in the form of field-aligned currents that close through the ionosphere. The pressure drives field-aligned currents through its gradient in the same manner as in quasi-static plasmas, but with modifications that are important if the bulk speed is of the order of the ion thermal speed; the variations in the pressure along field lines are maintained by a weak parallel potential drop. These effects are described in terms of the field-aligned currents in steady state, isotropic, MHD plasma. Solutions are developed by taking the MHD limit ot two-fluid solutions and illustrated in the special case of Maxwellian plasma for which the temperature is constant along magnetic field lines. The expression for the Birkeland current density is a generalization of Vasyliunas' expression for the field-aligned current density in quasi-static plasma and provides a unifying expression when both pressure gradients and ion inertia operate simultaneously as sources of field-aligned currents. It contains a full account of different aspects of the ion flow (parallel and perpendicular velocity and vorticity) that contribute to the currents. Contributions of ion inertia to field-aligned currents will occur in regions of strong velocity shear, electric field reversal, or large gradients in the parallel velocity or number density, and may be important in the low-latitude boundary layer, plasma sheet boundary layer, and the inner edge region of the plasma sheet.

Heinemann, M.↗

Inertial Currents in Isotropic Plasma

The magnetospheric convection electric field contributes to Birkeland currents. The effects of the field are to polarize the plasma by displacing the bounce paths of the ions from those of electrons, to redistribute the pressure so that it is not constant along magnetic field lines, and to enhance the pressure gradient by the gradient of the bulk speed. Changes in the polarization charge during the convection of the plasma are neutralized by electrons in the form of field-aligned currents that close through the ionosphere. The pressure drives field-aligned currents through its gradient in the same manner as in quasi-static plasma, but with modifications that are important if the bulk speed is of the order of the ion thermal speed; the variations in the pressure along field lines are maintained by a weak parallel potential drop. These effects are described in terms of the field-aligned currents in steady state, isotropic, MED plasma. Solutions are developed by taking the MHD limit of two-fluid solutions and illustrated in the special case of Maxwellian plasma for which the temperature is constant along magnetic field lines. The expression for the Birkeland current density is a generalization of Vasyliunas' expression for the field-aligned current density in quasi-static plasma and provides a unifying expression when both pressure gradients and ion inertia operate simultaneously as sources of field-aligned currents. It contains a full account of different aspects of the ion flow (parallel and perpendicular velocity and vorticity) that contribute to the currents. Contributions of ion inertia to field-aligned currents will occur in regions of strong velocity shear, electric field reversal, or large gradients in the parallel velocity or number density, and may be important in the low-latitude boundary layer, plasma sheet boundary layer, and the inner edge region of the plasma sheet.

Heinemann, M.↗

Fast Turn-Off Times Observed in Experimental 4H SiC Thyristors

Room temperature measurements of the turn-off time (t(sub q)) are reported for several packaged, npnp developmental power thyristors based on 4H-type SiC and rated 400 V, 2 A. Turn-off is effected by a 50 V pulse of applied reverse voltage, from a state of a steady 1 A forward current. Plots of t(sub q) against the ramp rate (dV(sub AK)/dt) of reapplied forward voltage are presented for preset values of limiting anode-to-cathode voltage (V(sub AK,max)). The lowest t(sub q) measured was about 180 ns. A rapid rise of these t(sub q) curves was observed for values of V(sub AK,max) that are only about a fifth of the rated voltage, whereas comparative t(sub q) plots for a commercial, fast turn-off, Si-based thyristor at a proportionately reduced V(sub AK,max) showed no such behavior. Hence these SiC thyristors may have problems arising from material defects or surface passivation. The influence the R-C-D gate bypass circuit that was used is briefly discussed.

Niedra, Janis M.↗

Solar Wind Stream Interaction Regions without Sector Boundaries

During periods of high solar activity when there are many sources of solar wind on the solar disk, a spacecraft occasionally encounters consecutive solar wind streams with the same magnetic polarity. The low-speed wind in the region of interaction between the two streams exhibits many of the same features as, but has some differences from, the low-speed wind that includes crossings of the heliospheric current sheet (HCS) where the direction of the heliospheric magnetic field reverses. The non-HCS slow wind exhibits many of the same small-scale structures usually associated with the slow wind around the HCS; these include discontinuous stream interfaces and other discontinuities, magnetic holes, and low-entropy structures. These entropy holes do not appear to have the same origin as the plasma sheets observed near the HCS, however. The helium abundances and heavy ion charge states in the non-HCS regions are not significantly different from those in HCS-associated regions. Some of the dynamical properties of the non-HCS regions differ from those found near the HCS; the regions between leading and trailing stream interfaces have a shorter duration or scale size, greater minimum speed, and lower peak and average densities. No correlation could be found between the non-HCS slow wind and visible coronal streamers.

interaction regions↗

Apparatus for Pumping a Fluid

An electrochemically actuated pump and an electrochemical actuator for use with a pump. The pump includes one of various stroke volume multiplier configurations with the pressure of a pumping fluid assisting actuation of a driving fluid bellows. The electrochemical actuator has at least one electrode fluidically coupled to the driving fluid chamber of the first pump housing and at least one electrode fluidically coupled to the driving fluid chamber of the second pump housing. Accordingly, the electrochemical actuator selectively pressurizes hydrogen gas within a driving fluid chamber. The actuator may include a membrane electrode assembly including an ion exchange membrane with first and second catalyzed electrodes in contact with opposing sides of the membrane, and first and second hydrogen gas chambers in fluid communication with the first and second electrodes, respectively. A controller may reverse the polarity of a voltage source electrically coupled to the current collectors.

van Boeyen, Roger W.↗

Calculating Conductance of Ion Channels

We have simulated two small ion channels in a water/membrane system, which consists of 71,000-72,000 atoms, and have estimated the conductance by way of counting ions crossing these channels in applied field. The calculated values of conductance have been compared with predictions of the electrodiffusion model. In a recently developed theoretical framework, all commonly used assumptions of the model can be tested. If they are satisfied, which is often the case, the approach provides a rigorous way to extrapolate conductance calculated at one voltage to other voltages. This, in turn, allows for efficient estimations of current-voltage dependence, examining rectifying behavior of channels and calculating the reversal potential. Furthermore, the consistency of the results can be precisely tested. Simulations at microsecond time scales are required to sufficiently reduce statistical errors and separate them from possible systematic errors. Only then the accuracy of the proposed approach can be properly tested. Linking simulations with electrophysiology provides a stringent, highly relevant test for the correctness of computer simulations of ion channels. Considering biological, medical and pharmaceutical importance of these proteins, results of the proposed study might motivate the development of improved hardware and software that would enable applying a similar strategy to more complex channels at longer times.

Ion↗

Angle Dependence of Focused X-Ray-Induced Single Event Transients in an Epitaxial Silicon Diode

Focused X-Ray single event transient (SET) experiments are performed at small angles on an epitaxial silicon diode at two reverse bias conditions. For both biases, the collected charge and peak current results follow the cosine law, while the transient fall time remains independent of incident angle. This demonstrates that only the amount of charge being generated is affected by angle and not the fundamental device response.

Heavy ions↗

Angle Dependence of Focused X-Ray-Induced Single Event Transients in an Epitaxial Silicon Diode

Focused X-Ray single event transient (SET) experiments are performed at small angles on an epitaxial silicon diode at two reverse bias conditions. For both biases, the collected charge and peak current results follow the cosine law, while the transient fall time remains independent of incident angle. This demonstrates that only the amount of charge being generated is affected by angle and not the fundamental device response for these relatively large devices.

Focused X-ray↗