Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample thickness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Solar Array in Simulated LEO Plasma Environment

Six different types of solar arrays have been tested in large vacuum chambers. The low Earth orbit plasma environment was simulated in plasma vacuum chambers, where the parameters could be controlled precisely. Diagnostic equipment included spherical Langmuir probes, mass spectrometer, low-noise CCD camera with optical spectrometer, video camera, very sensitive current probe to measure arc current, and a voltage probe to register variations in a conductor potential. All data (except video) were obtained in digital form that allowed us to study the correlation between external parameters (plasma density, additional capacitance, bias voltage, etc) and arc characteristics (arc rate, arc current pulse width and amplitude, gas species partial pressures, and intensities of spectral lines). Arc inception voltages, arc rates, and current collections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness causes the increase in arc inception voltage. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 m coverglass thickness and 60 V for the sample with 150 m coverglass thickness. Installation of cryogenic pump in large vacuum chamber provided the possibility of considerable outgassing of array surfaces which resulted in significant decrease of arc rate. Arc sites were determined by employing a video-camera, and it is shown that the most probable sites for arc inception are triple-junctions, even though some arcs were initiated in gaps between cells. It is also shown that the arc rate increases with increasing of ion collection current. The analysis of optical spectra (240-800 nm) reveals intensive narrow atomic lines (Ag, H) and wide molecular bands (OH, CH, SiH, SiN) that confirms a complicated mechanism of arc plasma generation. The results obtained seem to be important for the understanding of the arc inception mechanism, which is absolutely essential for progress toward the design of high-voltage solar array for space application.

Vayner, Boris↗

PNNL's Characterization Summary for MP-2 Experiment

Characterization of as-fabricated fuel was performed at Pacific Northwest National Laboratory (PNNL) in accordance with the characterization plan for the fabrication of U 10Mo plate fuel for the U.S. High Performance Research Reactor conversion program’s Fuel Fabrication Pillar (INL 2021). Similar characterization work is also being performed at Idaho National Laboratory to provide a detailed understanding of the as-fabricated foils that would be irradiated in the Mini-Plate 2 (MP 2) experiment. Under the MP 2 characterization plan, foils are studied that have different fabrication parameters (such as rolling condition, rolling thickness reduction, co-rolling with Zr layers). Similar samples from master foils were sent to both the organizations, so that the testing and analysis can be done independently using similar equipment and standardized measurement and analysis procedures. A final, consolidated report will be prepared based on this work and will summarize all the information obtained from the two laboratories. The MP 2 experiment will provide an opportunity to understand the effects of processing conditions on the final fuel microstructure, to compare results obtained independently, and achieve a two-way validation. In Fiscal Year 2022, PNNL received five MP 2 cast (PD STD2) samples to examine the foils’ chemistry and microstructure. For each cast sample, PNNL received samples from three different locations. PNNL also received and characterized 24 U 10Mo foil samples, by sectioning four pieces/specimens from each foil, in accordance with the MP 2 Characterization Plan (INL 2021). These 24 samples consist of four types of foils from BWX Technologies: 0.047 in. thick hot-rolled and annealed samples with Zr layers; 0.025 in. thick cold-rolled and annealed samples with Zr layers; 0.0105 in. thick cold-rolled and annealed samples with Zr layers. Along with these, PNNL also received four plates with Zr layers that were 0.025 in. and 0.0105 in. thick. This report describes the results of PNNL’s MP 2 foil characterization. Microstructure, Mo homogeneity, carbide fraction and morphology, U 10Mo foil thickness, and Zr thickness were evaluated in both the longitudinal and transverse directions for all the foils of the three different thicknesses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preparative electrophoresis for space

A premise of continuous flow electrophoresis is that removal of buoyancy-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chambers are used, distortion of the injected sample stream due to electrohydrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field have not been considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection.

Rhodes, Percy H.↗

Preparative electrophoresis for space

A premise of continuous flow electrophoresis is that removal of buoyance-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chamber are used, distortion of the injected sample stream due to electrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field were not considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection.

Rhodes, Percy H.↗

Absolute Thickness Measurements on Coatings Without Prior Knowledge of Material Properties Using Terahertz Energy

This study investigates the applicability of a novel noncontact single-sided terahertz electromagnetic measurement method for measuring thickness in dielectric coating systems having either dielectric or conductive substrate materials. The method does not require knowledge of the velocity of terahertz waves in the coating material. The dielectric coatings ranged from approximately 300 to 1400 m in thickness. First, the terahertz method was validated on a bulk dielectric sample to determine its ability to precisely measure thickness and density variation. Then, the method was studied on simulated coating systems. One simulated coating consisted of layered thin paper samples of varying thicknesses on a ceramic substrate. Another simulated coating system consisted of adhesive-backed Teflon adhered to conducting and dielectric substrates. Alumina samples that were coated with a ceramic adhesive layer were also investigated. Finally, the method was studied for thickness measurement of actual thermal barrier coatings (TBC) on ceramic substrates. The unique aspects and limitations of this method for thickness measurements are discussed.

Nondestructive evaluation↗

The Two-Cavity Method for Characterizing Acoustical Materials—an Interlaboratory Study

This study focuses on understanding the sound absorption characteristics of porous acoustic materials, which are determined by two key parameters independent of material thickness: characteristic impedance and propagation constant. These parameters can be characterized by testing a porous sample concept in a normal incidence impedance tube using either the two-thickness or the two-cavity method. In the two-thickness method, two samples of varying thicknesses are required. In contrast, the two-cavity method requires testing one sample at two different air cavity depths behind the porous material. This method is particularly advantageous for materials that are costly or challenging to fabricate. This interlaboratory study evaluates the variability of characteristic properties determined using the two-cavity method. Porous acoustic materials were additively manufactured and tested in the Liner Technology Facility(LTF)at NASA Langley Research Center and the Mechanics, Acoustics and Dynamics Lab (MADLab) at Michigan Technological University. The characteristic properties derived from various cavity depth combinations were used to predict the surface impedance of the sample with a rigid backing. The prediction was then compared the measured impedance spectrum. It was also found that the combinations of cavity depths can significantly influence the accuracy of the deduced properties.

acoustic liners↗

Reexamination of hydrodynamic phonon transport in thin graphite

The recent hydrodynamic phonon transport theory for graphitic materials has been supported by the measurements of the second sound at temperatures up to about 100 K. When boundary scattering becomes comparable to momentum-conserving normal phonon scattering processes that are responsible for phonon hydrodynamics, Poiseuille phonon flow phenomena can emerge to give rise to unique size-dependent thermal conductivity in thin graphite. Here, we examine the thickness range for the Poiseuille phonon flow to become observable in thin graphite with the use of both deviational Monte Carlo simulation of the Peierls-Boltzmann transport equation and four-probe thermal transport measurements. As the basal-plane thermal conductivity calculated by prior first-principles theories saturates to the graphite value when the thickness is increased to five graphene layers, the phonon dispersion of graphite is used in the current calculations of thin graphite of micrometer thickness and a 23-layer thick ultrathin graphite (UTG) sample. The calculations show that diffuse surface scattering by surface defects can lead to Poiseuille phonon flow at 50 K in thin graphite with the thickness close to several micrometers but not in the 65 μm thin graphite and 23-layer UTG, where phonon scattering by the top and bottom surfaces become, respectively, much less and more frequent than the normal processes. In addition, the calculation results with the bulk graphite dispersion and diffuse surface scattering show decreased basal-plane thermal conductivity with decreasing thickness, opposite to recent thermocouple measurements of thin graphite samples. In comparison, the calculation results reveal that partially diffuse surface defect scattering can yield the four-probe measurement results of UTG samples, which are prepared here with an improved process to minimize surface contamination.

36 MATERIALS SCIENCE↗

Effects on LDEF exposed copper film and bulk

Two forms of copper were exposed to the Long Duration Exposure Facility (LDEF) Mission 1 environment: a copper film, initially 74.2 plus or minus 1.1 nm thick sputter coated on a fused silica flat and a bulk piece of oxygen-free, high conductivity (OFHC) copper. The optical density of the copper film changed from 1.33 to 0.70 where exposed, and the film thickness increased to 106.7 plus or minus 0.5 nm where exposed. The exposed area appears purple by reflection and green by transmission for the thin film and maroon color for the bulk copper piece. The exposed areas increased in thickness, but only increase in the thickness of the thin film sample could be readily measured. The increase in film thickness is consistent with the density changes occurring during conversion of copper to an oxide. However, we have not been able to confirm appreciable conversion to an oxide by x-ray diffraction studies. We have not yet subjected the sample to e-beams or more abusive investigations out of concern that the film might be modified.

Peters, Palmer N.↗

Probing the lattice structure of dynamically compressed and released single crystal iron through the alpha to epsilon phase transition

In this work, experiments using broadband Laue x-ray diffraction (XRD) were used to examine the lattice structure of dynamically compressed [100]-oriented single crystal iron samples at the Dynamic Compression Sector at the Advanced Photon Source. These experiments used 1 μm thick iron single crystal samples sandwiched between a polyimide ablator and a polycarbonate window. A 100 J, 10 ns duration laser pulse incident on the polyimide ablator was used to shock compress the iron samples to initial stresses greater than 25 GPa, exceeding the ~13 GPa alpha (body-centered-cubic or bcc structure) to epsilon (hexagonal-close-packed or hcp structure) phase transition stress. XRD measurements were performed at various times relative to the shock wave entering the iron sample: early times, <~150 ps while the initial shock waves propagated through the iron; intermediate times, after the iron equilibrated with the ablator and window reaching a plateau stress state (12 or 17 GPa) lasting several nanoseconds; and late times, during uniaxial strain release. The early time measurements show that in <~150 ps, the high-pressure hcp phase is relaxed with a c/a ratio of 1.61, contrary to previous laser shock experiments where a c/a ratio of 1.7 was inferred. In the plateau stress state and partially released states, XRD measurements showed that the hcp structure retained a c/a ratio of 1.61 with no observable changes in the microstructure. Upon stress release at ~1 GPa/ns release rate, the reverse phase transition (hcp to bcc) to the original single crystal orientation (implying a transformation memory effect) was observed to reach completion somewhere between 13 and 11 GPa, indicating little stress hysteresis under rapid uniaxial strain release. A similar memory effect for the reverse hcp to bcc transformation has been previously observed under hydrostatic compression. However, the bcc/hcp orientation relationships differ somewhat between dynamic and static compression experiments, implying that the transformation pathway under uniaxial dynamic strain differs from the Burgers mechanism.

36 MATERIALS SCIENCE↗

Characterization Report for the MP-1 Experiment Fabrication Campaign

This report covers the results of MP 1 fuel characterization analysis to provide a detailed understanding of the as-fabricated fuel that would be irradiated in the MP 1 (Mini-Plate 1) experiment. The work was performed at Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL), and Los Alamos National Laboratory (LANL). Characterization of the as-fabricated fuel was performed in accordance with Characterization Plan for the Fabrication of U 10Mo for the MP 1 Experiment, hereinafter the MP 1 Characterization Plan (MAQP 2016). Under the MP 1 Characterization Plan, fuel foils at different points in the foil fabrication process (e.g., hot rolled annealed, cold rolled annealed) were studied to understand the effect of various thermomechanical processes on the fuel microstructure. Samples were sent to each of the three organizations so that testing and analysis could be performed independently using similar equipment and a standardized set of measurement and analysis procedures. The MP 1 experiment will provide an opportunity to understand the effects of processing conditions on the final fuel microstructure, to compare independently obtained results, and achieve a three-way validation. PNNL characterized 28 uranium–10 wt% molybdenum (U 10Mo) samples. Six pieces/specimens from each sample/foil were sectioned, in accordance with the MP 1 Characterization Plan. Similarly, INL and LANL also examined 24 and 17 U 10Mo specimens, respectively. These total 69 samples consist of six types of MP 1 characterization foils fabricated by Babcock and Wilcox Technologies (BWXT) from ingots produced by the Y-12 National Security Complex: • 0.047 in.-thick hot-rolled and annealed samples with and without Zr layers • 0.02 in.-thick cold-rolled and annealed samples with and without Zr layers • 0.01 in.-thick cold-rolled and annealed samples with and without Zr layers. Microstructure, chemical composition, carbide morphology, U 10Mo foil thickness, Zr thickness, mechanical properties (microhardness), and density were evaluated in both longitudinal and transverse directions for foils of the three different thicknesses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LCO Synthesis by Sol-Gel Method

The synthesis of Lanthanum Cobalt Oxide (LCO) via Sol-Gel method provides a potentially low-cost method of production for a P-type photocatalytic. LCO was prepped from Lanthanum and Nitrate Precursors in Aqueous solution. After a significant amount of water is evaporated, the solution is deposited onto SiO2 substrate via spin-deposition method. After annealing, the samples produce thin film LCO that display thickness of sub-500 nanometers. The samples material profile is confirmed by both Raman spectroscopy and X-Ray Diffraction spectroscopy (XRD). Additionally, two-point probing tested the conductivity of the samples. The thin film samples display characteristics of a P-type photocatalytic and may potentially be used in the formation of a P-N junction for user in water-splitting applications.

36 MATERIALS SCIENCE↗

Hypervelocity Impact Performance of 3D Printed Aluminum Panels

With the continued development of additive manufacturing methods, control over the shape of ligaments, cell regularity, and macroscopic shape can all be easily tuned. This capability allows for tailoring of component architecture and promotes potential mass savings in a space vehicle structure. Additionally, it allows one the flexibility of combining structural elements such as MMOD protection and vehicle stiffness for launch loads for an overall mass reduction. At NASA JSC this technology is being explored in many different ways with the goal being a multifunctional structural component. For this study, four different types of aluminum panels have been 3D printed for testing, three being of a body centric cubic (BCC) lattice structure core and one being kelvin cell structure core. All samples have a 5.33 cm (0.05”) nominally thick aluminum face sheet printed on the front and back side of each panel, with all core materials having a 5.08 cm (2.0”) nominal thickness (see Table 1 for test sample summary and Figures 1 – 2 for sample illustrations). These tests will evaluate the performance of 3D printed aluminum panels under hypervelocity impact (HVI) conditions. The hypervelocity impact tests are being conducted at the JSC White Sands Test Facility (WSTF) Remote Hypervelocity Test Laboratory (RHTL), located in Las Cruces, New Mexico. All tests will be conducted with a 3.4mm Al 2017-T4 sphere at 6.8 km/s impacting at 0° to surface normal (i.e., impacting with no obliquity). Each sample will be trapped between two metal frames, with gasket material residing between the sample and frame, which will be the shipping and testing configuration for all tests. There will be an Al 2017-T4 witness plate staged 5.08 cm (2.0”) from each sample to capture signature of debris, if the rear face sheet of the sample were to perforate from the HVI test event.

Davis, B. A.↗

Ion irradiation effects on Cr-coated zircaloy-4 surface wettability and pool boiling critical heat flux.

The concept of coating the currently used nuclear fuel cladding (zirconium-based alloy, typically Zircaloy-4 or Zirc-4) with an oxidation preventive layer is a progressing Accident tolerant Fuel (ATF) candidate alloys. The coated Zirc-4-based alloys could be a solution to suppress undesirable fast reaction kinetics with high-temperature steam. Zirc-4 has been the most preferred cladding material in pressurized water reactors (PWRs). Chromium (Cr) based alloys as a coating material provides excellent corrosion protection and good strength and wear resistance. In this paper, we present the surface wettability measurements and pool boiling Critical Heat Flux (CHF) for Cr-coated Zirc-4 claddings pre- and post-exposure to an ion irradiation environment. The wettability measurements, including static contact angle (contact angle, θ) and average surface roughness (surface roughness, Ra), are introduced for samples of different coating thicknesses (5–30 μm thick). The coatings fabricated by the cold spray of Cr-Al particles to 10 mm × 10 mm × 1.95 mm Zirc-4 substrates. Post fabrication, a Pilgering (cold rolling) process, was applied to finalize the coating thickness and resulted in a significant reduction in surface roughness of initially fabricated rough surfaces. The process produced three distinguished samples 5-μm unpolished (as machined), 5-μm, and 30-μm polished (cold rolled). The measurements are presented for the three surfaces and bare Zirc-4 as a baseline surface. The contact angle analyses were implemented in theoretical models from the literature to predict pool boiling CHF. Pool boiling experiments were conducted to measure the pool boiling CHF values and compare them to the predicted values. Scanning Electron Microscope (SEM) images and Energy Dispersive X-ray Spectroscopy (EDS) analysis was performed to characterize the surfaces for better understanding and interpreting the results. The SEM images showed localized surface damage due to ion irradiation. No recognized change in the measured surface roughness due to ion irradiation. The contact angles of irradiated Cr-coated surfaces are consistently higher (10°) than pre-irradiated surfaces. Decreasing the Cr-coating layer thickness resulted in lower contact angle pre- and post- ion irradiation. The predicted pool boiling CHF using the Kandlikar model is in good agreement with the experimentally measured CHF values within ±12% for all samples.

36 MATERIALS SCIENCE↗

Characterization Report for the MP-1 Experiment Fabrication Campaign (Rev.1)

This report covers the results of MP 1 fuel characterization analysis to provide a detailed understanding of the as-fabricated fuel that would be irradiated in the MP 1 (Mini-Plate 1) experiment. The work was performed at Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL), and Los Alamos National Laboratory (LANL). Characterization of the as-fabricated fuel was performed in accordance with Characterization Plan for the Fabrication of U 10Mo for the MP 1 Experiment, hereinafter the MP 1 Characterization Plan (MAQP 2016). Under the MP 1 Characterization Plan, fuel foils at different points in the foil fabrication process (e.g., hot rolled annealed, cold rolled annealed) were studied to understand the effect of various thermomechanical processes on the fuel microstructure. Samples were sent to each of the three organizations so that testing and analysis could be performed independently using similar equipment and a standardized set of measurement and analysis procedures. The MP 1 experiment will provide an opportunity to understand the effects of processing conditions on the final fuel microstructure, to compare independently obtained results, and achieve a three-way validation. PNNL characterized 28 uranium–10 wt% molybdenum (U 10Mo) samples. Six pieces/specimens from each sample/foil were sectioned, in accordance with the MP 1 Characterization Plan. Similarly, INL and LANL also examined 24 and 17 U 10Mo specimens, respectively. These total 69 samples consist of six types of MP 1 characterization foils fabricated by Babcock and Wilcox Technologies (BWXT) from ingots produced by the Y-12 National Security Complex: (a.) 0.047 in.-thick hot-rolled and annealed samples with and without Zr layers; (b.) 0.02 in.-thick cold-rolled and annealed samples with and without Zr layers; and (c.) 0.01 in.-thick cold-rolled and annealed samples with and without Zr layers. Microstructure, chemical composition, carbide morphology, U 10Mo foil thickness, Zr thickness, mechanical properties (microhardness), and density were evaluated in both longitudinal and transverse directions for foils of the three different thicknesses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

A study of the properties of beryllium doped silicon with particular emphasis on diffusion mechanisms: Profiles of depth dependent conductivity as determined by electrical surface probes

Very large diffusion coefficients were encountered and required the determination of impurity profiles for samples approximately 1 cm thick. Since conductivity values are readily converted into concentrations of electrically active impurities, the major problem became that of accurately determining the conductivity profiles of beryllium diffused silicon samples. Four-point probe measurements on samples having depth conductivities are interpreted in terms of conductivity profiles, based on an exact solution of the problem of exponentially depth dependent conductivity. Applications include surface conductivity determination where the form of the conductivity profile is known, and conductivity profile determination from probe measurements taken as the sample surface is progressively lapped away. The application is limited to samples having conductivity monotonically decreasing with depth from the probed surface.

Franks, R. K.↗

Thermal Analysis and Design of Multi-layer Insulation for Re-entry Aerodynamic Heating

The combined radiation/conduction heat transfer in high-temperature multi-layer insulations was modeled using a finite volume numerical model. The numerical model was validated by comparison with steady-state effective thermal conductivity measurements, and by transient thermal tests simulating re-entry aerodynamic heating conditions. A design of experiments technique was used to investigate optimum design of multi-layer insulations for re-entry aerodynamic heating. It was found that use of 2 mm foil spacing and locating the foils near the hot boundary with the top foil 2 mm away from the hot boundary resulted in the most effective insulation design. A 76.2 mm thick multi-layer insulation using 1, 4, or 16 foils resulted in 2.9, 7.2, or 22.2 percent mass per unit area savings compared to a fibrous insulation sample at the same thickness, respectively.

Daryabeigi, Kamran↗

Interaction of atomic oxygen with thin film and bulk copper: An XPS, AES, XRD, and profilometer study

The University of Alabama in Huntsville (UAH) experiment A-0114 was designed primarily to study degradation of material surfaces due to low earth orbital (LEO) atmospheric oxygen. The experiment contained 128 one inch circular samples: metals, polymers, carbons, and semiconductors. Among metal samples, copper has shown some interesting new results. Two types of copper samples, a film sputter coated on fused silica and a bulk piece of OFHC copper, were characterized employing a variety of techniques such as X-ray and Auger electron spectroscopies, X-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to characterize the presence of Cu2O and CuO in addition to Cu Auger LMM lines. These results are supported by our recent X-ray diffraction studies which clearly establish the presence of Cu oxides which we were unable to prove in our earlier work. Profilometry showed an increase in thickness of the film sample where exposed to 106.7 +/- 0.5 nm from an initial thickness of 74.2 +/- 1.1 nm. Further studies with SEM and ellipsometry are underway.

Raikar, Genesh N.↗