Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Factors governing extracellular DNA degradation dynamics in soil

We examined the impacts of soil moisture, temperature, agricultural management and habitat type on the degradation dynamics of eDNA in soils. Synthetic eDNA was added to soil microcosms, and its disappearance over time was measured using both high-throughput sequencing and qPCR. The synthetic eDNA was degraded rapidly, but a small fraction remained detectable throughout the experiments (39–80 days). The eDNA degradation rate was positively correlated with moisture and temperature, but negatively correlated with soil organic carbon content. End-point stabilization of eDNA was highest at low moisture and temperature, but exhibited no relationship with soil organic carbon. Tilled soils had higher rates of degradation and less stabilization than no-till soils. Among different habitats we observed that forest soils had the slowest degradation rate, and meadow soils had the greatest stabilization of eDNA. While eDNA was detectable by qPCR in all treatments across all time-points, it became inconsistently detectable with high-throughput gene sequencing in less than 1 week. We conclude that eDNA degradation and stabilization dynamics vary with moisture, temperature and habitat characteristics, that small amounts of eDNA may persist in soils indefinitely, and that the ability of persistent eDNA to impact microbial community estimates depends on method sensitivity and experimental objectives.

59 BASIC BIOLOGICAL SCIENCES↗

Growth of epitaxial iron nitride ultrathin film on zinc-blende gallium nitride

The authors report the growth of iron nitride on zinc-blende gallium nitride using molecular beam epitaxy. First, zinc-blende GaN is grown on a magnesium oxide substrate having (001) orientation; second, an ultrathin layer of FeN is grown on top of the GaN layer. In situ reflection high-energy electron diffraction is used to monitor the surface during growth, and a well-defined epitaxial relationship is observed. Cross-sectional transmission electron microscopy is used to reveal the epitaxial continuity at the gallium nitride-iron nitride interface. Surface morphology of the iron nitride, similar to yet different from that of the GaN substrate, can be described as plateau valley. The FeN chemical stoichiometry is probed using both bulk and surface sensitive methods, and the magnetic properties of the sample are revealed.

36 MATERIALS SCIENCE↗

Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET

Purpose: Side readout of scintillation light from crystal elements in positron emission tomography (PET) is an alternative to conventional end-readout configurations, with the benefit of being able to provide accurate depth-of-interaction (DOI) information and good energy resolution while achieving excellent timing resolution required for time-of-flight PET. This paper explores different readout geometries of scintillation crystal elements with the goal of achieving a detector that simultaneously achieves excellent timing resolution, energy resolution, spatial resolution, and photon sensitivity. Methods: The performance of discrete LYSO scintillation elements of different lengths read out from the end/side with digital silicon photomultipliers (dSiPMs) has been assessed. Results: Compared to 3 × 3 × 20 mm{sup 3} LYSO crystals read out from their ends with a coincidence resolving time (CRT) of 162 ± 6 ps FWHM and saturated energy spectra, a side-readout configuration achieved an excellent CRT of 144 ± 2 ps FWHM after correcting for timing skews within the dSiPM and an energy resolution of 11.8% ± 0.2% without requiring energy saturation correction. Using a maximum likelihood estimation method on individual dSiPM pixel response that corresponds to different 511 keV photon interaction positions, the DOI resolution of this 3 × 3 × 20 mm{sup 3} crystal side-readout configuration was computed to be 0.8 mm FWHM with negligible artifacts at the crystal ends. On the other hand, with smaller 3 × 3 × 5 mm{sup 3} LYSO crystals that can also be tiled/stacked to provide DOI information, a timing resolution of 134 ± 6 ps was attained but produced highly saturated energy spectra. Conclusions: The energy, timing, and DOI resolution information extracted from the side of long scintillation crystal elements coupled to dSiPM have been acquired for the first time. The authors conclude in this proof of concept study that such detector configuration has the potential to enable outstanding detector performance in terms of timing, energy, and DOI resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Van der Waals engineering of ferromagnetic semiconductor heterostructures for spin and valleytronics

The integration of magnetic material with semiconductors has been fertile ground for fundamental science as well as of great practical interest toward the seamless integration of information processing and storage. We create van der Waals heterostructures formed by an ultrathin ferromagnetic semiconductor CrI 3 and a monolayer of WSe 2 . We observe unprecedented control of the spin and valley pseudospin in WSe 2 , where we detect a large magnetic exchange field of nearly 13 T and rapid switching of the WSe 2 valley splitting and polarization via flipping of the CrI 3 magnetization. The WSe2 photoluminescence intensity strongly depends on the relative alignment between photoexcited spins in WSe 2 and the CrI 3 magnetization, because of ultrafast spin-dependent charge hopping across the heterostructure interface. The photoluminescence detection of valley pseudospin provides a simple and sensitive method to probe the intriguing domain dynamics in the ultrathin magnet, as well as the rich spin interactions within the heterostructure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accelerated discovery of metallic glasses through iteration of machine learning and high-throughput experiments

With more than a hundred elements in the periodic table, a large number of potential new materials exist to address the technological and societal challenges we face today; however, without some guidance, searching through this vast combinatorial space is frustratingly slow and expensive, especially for materials strongly influenced by processing. We train a machine learning (ML) model on previously reported observations, parameters from physiochemical theories, and make it synthesis method–dependent to guide high-throughput (HiTp) experiments to find a new system of metallic glasses in the Co-V-Zr ternary. Experimental observations are in good agreement with the predictions of the model, but there are quantitative discrepancies in the precise compositions predicted. We use these discrepancies to retrain the ML model. The refined model has significantly improved accuracy not only for the Co-V-Zr system but also across all other available validation data. We then use the refined model to guide the discovery of metallic glasses in two additional previously unreported ternaries. Although our approach of iterative use of ML and HiTp experiments has guided us to rapid discovery of three new glass-forming systems, it has also provided us with a quantitatively accurate, synthesis method–sensitive predictor for metallic glasses that improves performance with use and thus promises to greatly accelerate discovery of many new metallic glasses. We believe that this discovery paradigm is applicable to a wider range of materials and should prove equally powerful for other materials and properties that are synthesis path–dependent and that current physiochemical theories find challenging to predict.

36 MATERIALS SCIENCE↗

Biogeochemical controls of surface ocean phosphate

Surface ocean phosphate is commonly below the standard analytical detection limits, leading to an incomplete picture of the global variation and biogeochemical role of phosphate. A global compilation of phosphate measured using high-sensitivity methods revealed several previously unrecognized low-phosphate areas and clear regional differences. Both observational climatologies and Earth system models (ESMs) systematically overestimated surface phosphate. Furthermore, ESMs misrepresented the relationships between phosphate, phytoplankton biomass, and primary productivity. Atmospheric iron input and nitrogen fixation are known important controls on surface phosphate, but model simulations showed that differences in the iron-to-macronutrient ratio in the vertical nutrient supply and surface lateral transport are additional drivers of phosphate concentrations. Our study demonstrates the importance of accurately quantifying nutrients for understanding the regulation of ocean ecosystems and biogeochemistry now and under future climate conditions.

54 ENVIRONMENTAL SCIENCES↗

Editors’ Choice—Rapid Deactivation Convolutes Electrochemical CO 2 Reduction Selectivity Measurements on Gold Rotating Ring Disk Electrodes

Voltammetric measurements of electrochemical CO 2 reduction reaction (CO 2 RR) selectivity on rotating ring disk electrodes (RRDE) are a rapid and sensitive method for quantifying an electrocatalyst’s selectivity, i.e. faradaic efficiency (FE). This method has been applied to polycrystalline Au electrocatalysts where a Au disk electrode catalyzes both the CO 2 RR and hydrogen evolution reaction while the concentric Au ring electrode selectively senses CO by oxidizing CO back to CO 2 . Such measurements enabled fundamental mechanistic studies but suffer from poor inter-laboratory reproducibility. This work identifies causes of variability in RRDE selectivity measurements by comparing protocols with different electrochemical methods, reagent purities, and glassware cleaning procedures. We observed FE CO decrease by 56% during 5 min chronoamperometry measurements, a phenomenon that is not readily apparent in voltammetric scans due to their dynamic nature. Electroplating of electrolyte impurities onto the disk and ring surfaces were identified as a major contributor to Au deactivation. Additionally, the oxygen reduction reaction may lead to higher disk currents in inadequately purged electrolytes, causing an apparent underestimation of FE CO at low overpotentials. Lastly, we propose operational bounds for CO 2 RR selectivity measurements on Au using the RRDE method and provide suggestions on steps for improving the accuracy of this technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DARHT Axis-I Diode Simulations II: Geometrical Scaling

Flash radiography of large hydrodynamic experiments driven by high explosives is a venerable diagnostic technique in use at many laboratories. Many of the largest hydrodynamic experiments study mockups of nuclear weapons, and are often called hydrotests for short. The dual-axis radiography for hydrodynamic testing (DARHT) facility uses two electron linear-induction accelerators (LIA) to produce the radiographic source spots for perpendicular views of a hydrotest. The first of these LIAs produces a single pulse, with a fixed ~60-ns pulsewidth. The second axis LIA produces as many as four pulses within 1.6-μs, with variable pulsewidths and separation. There are a wide variety of hydrotest geometries, each with a unique radiographic requirement, so there is a need to adjust the radiographic dose for the best images. This can be accomplished on the second axis by simply adjusting the pulsewidths, but is more problematic on the first axis. Changing the beam energy or introducing radiation attenuation also changes the spectrum, which is undesirable. Moreover, using radiation attenuation introduces significant blur, increasing the effective spot size. The dose can also be adjusted by changing the beam kinetic energy. This is a very sensitive method, because the dose scales as the ~2.8 power of the energy, but it would require retuning the accelerator. This leaves manipulating the beam current as the best means for adjusting the dose, and one way to do this is to change the size of the cathode. This method has been proposed, and is being tested. This article describes simulations undertaken to develop scaling laws for use as design tools in changing the Axis-1 beam current by changing the cathode size.

43 PARTICLE ACCELERATORS↗

Developing a New Accelerator Mass Spectrometry Assay for Quantitation of Platinum DNA Adducts for Response to Platinum-Based Chemotherapy

Platinum-based drugs are the most successful class of compounds for the treatment of cancer. These drugs kill cancer cells through toxic DNA damage. However, many patients are unresponsive to treatment or acquire drug resistance. We will address this problem using 14C-labeled carboplatin and 14C-labeled oxaliplatin, both platinum-based anticancer drugs, and accelerator mass spectrometry (AMS), the most sensitive method for studying long-lived isotopes. We will measure platinum-DNA adducts in cultured cancer cells and mice exposed to the compounds. This study aims to develop an assay for determining which patients will benefit from carboplatin treatment and which will be resistant. This project is being conducted in collaboration with researchers from the UC Davis Cancer Center.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary Tests For Development Of A Non-Pertechnetate Analysis Method

The objective of this task was to develop a non-pertechnetate analysis method that 222-S lab could easily implement. The initial scope involved working with 222-S laboratory personnel to adapt the existing Tc analytical method to fractionate the non-pertechnetate and pertechnetate. SRNL then developed and tested a method using commercial sorbents containing Aliquat ® 336 to extract the pertechnetate (thereby separating it from non-pertechnetate), followed by oxidation, extraction, and stripping steps, and finally analysis by beta counting and Mass Spectroscopy. Several additional items were partially investigated, including impacts of a 137 Cs removal step. The method was initially tested on SRS tank waste samples to determine its viability. Although SRS tank waste does not contain non-pertechnetate, testing with it was useful to investigate the compatibility, separation efficiency, interference removal efficacy, and method sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of FRET clusters for CBRN Detection

Advanced sensor capabilities for the simultaneous on-site detection of specific chemical, biological, and radiological/nuclear (CBRN) threats is important to significantly limit the risk of exposure to personnel and allow the rapid collection of essential scientific data and critical evidence. Commercially available sensor capabilities are generally complex, and/or require highly specific and ultra-sensitive methods that are often power demanding or require offsite post-analysis for positive detection, leaving personnel vulnerable. The goal of this project is to develop a portable sensor capable of simultaneously detecting CBRN signatures using a multiplexed Förster Resonance Energy Transfer (FRET) based sensor. FRET sensors are tailorable, specific, and highly dependent on the donor-acceptor distance. In this project, nanoparticles were functionalized with aptamers that were designed for the detection of methylphosphonate, a sarin metabolite. FRET was measured between quantum dot donors and dye and metal nanoparticle acceptors using optical spectroscopy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of COTS Electronics by Power Spectrum Analysis and Multivariate Data Analysis

Power spectrum analysis (PSA) is a fast, non-destructive, sensitive method for examining commercial off-the-shelf ( COTS ) electronic components. These features make PSA attractive for both component screening and surveillance in support of component reliability efforts. Current analysis methods limit the utility of PSA due to the need to manually examine the results of analysis to identify anomalous parts. This study demonstrates the development and application of a workflow to automate the screening of COTS electronic components. Further, this study demonstrates the use of multivariate algorithms to assess aging of Zener diodes. These workflows can be readily extended to other components, combining the benefits of PSA and multivariate analysis to screen and evaluate COTS electronic components.

42 ENGINEERING↗

Neutrons and Complementary Techniques for Quantum Materials

The virtual workshop “Neutrons and Complementary Techniques for Quantum Materials” was held September 6-8, 2022. As the investigation of quantum materials progresses, researchers can no longer deal with the bulk properties and surface states separately. Many open questions require the combination of complementary methods sensitive to different degrees of freedom to provide a more comprehensive view. This workshop intends to create a bridge for the science community focusing on different techniques to educate each other so we will gain a better understanding of the strength, weakness/limits, the most recent new developments, and future directions for each technique. Through this workshop we intended to raise the awareness of developments in techniques complimentary to neutron scattering, thereby maximizing the impact of our work and strengthening collaborations across experimental techniques in the research of quantum materials.

36 MATERIALS SCIENCE↗

Automated Algorithms for Screening Electronic Parts for Aging using Power Spectra Analysis (PSA) Data

Understanding the age of semiconductor parts being built into devices and systems is of interest for manufacturing quality control. Power spectrum analysis (PSA) is a fast, non-destructive, sensitive method for examining semiconductor parts. This talk will cover the use of multivariate analysis on both PSA data and conventional current-voltage data generated prior to PSA analysis to create algorithms that can be automated to screen semiconductor parts for aging.

Multari, Rosalie A↗

Development of a Lateral Flow Strip-Based Recombinase-Aided Amplification for Active Chlamydia psittaci Infection

Chlamydia psittaci is the causative agent of psittacosis, a worldwide zoonotic disease. A rapid, specific, and sensitive diagnostic assay would be benefit for C. psittaci infection control. In this study, an assay combining recombinase-aided amplification and a lateral flow strip (RAA-LF) for the detection of active C. psittaci infection was developed. The RAA-LF assay targeted the CPSIT_RS02830 gene of C. psittaci and could be accomplished in 15 min at a single temperature (39°C). The analytical sensitivity of the assay was as low as 1 × 10 0 copies/μl and no cross-reaction with some other intracellular pathogens was observed. Moreover, all feces samples from mice infected with C. psittaci at day-1 post-infection were positive in the RAA-LF assay. In conclusion, the RAA-LF assay provides a convenient, rapid, specific and sensitive method for detection of active C. psittaci infection and it is also suitable for C. psittaci detection in field.

Jiao, Jun↗

Identification and evaluation of linear damping models in beam vibrations

Sensitive method, identifying effective damping mechanisms, involves comparing experimentally determined ratio of first to second mode magnification factors related to common point on beam. Cluster size has little effect on frequencies of elements, magnification factor decreases with cluster size, and viscous and stress damping are dominant damping mechanisms.

Boers, B. L.↗

The use of the transmission windows of the Fabry-Perot interferometer in the detection of Raman scattered radiation from atmospheric gases.

Demonstration that the use of the Fabry-Perot interferometer as a filter with transmission windows occurring at regular intervals in wave numbers provides a highly sensitive method for detection of atmospheric gases using their rotational Raman spectra excited by a suitable laser. Some of the operating advantages include signal gains of several orders of magnitude, a simple direct interpretation of the results in terms of the density and types of the gaseous constituents, size and weight reductions from conventional apparatus, ease of operation, and relative freedom from interference from other molecules in the scattering volume. This method is compared with the techniques that have been discussed in the literature by other workers in the field.

Smith, W. H.↗

The simultaneous quantitation of ten amino acids in soil extracts by mass fragmentography

A specific and sensitive method for the identification and simultaneous quantitation by mass fragmentography of ten of the amino acids present in soil was developed. The technique uses a computer driven quadrupole mass spectrometer and a commercial preparation of deuterated amino acids is used as internal standards for purposes of quantitation. The results obtained are comparable with those from an amino acid analyzer. In the quadrupole mass spectrometer-computer system up to 25 pre-selected ions may be monitored sequentially. This allows a maximum of 12 different amino acids (one specific ion in each of the undeuterated and deuterated amino acid spectra) to be quantitated. The method is relatively rapid (analysis time of approximately one hour) and is capable of the quantitation of nanogram quantities of amino acids.

Pereira, W. E.↗