Search NASA⌕ Search

SEARCH · Search NASA

Results for “software estimate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Swift Mission Gyro Patch and Re-Calibration Without A Calibration Campaign

The Swift spacecraft has three Two-Axis-Rate-Assemblies (TARAs) (designated as TARA 1, TARA 2, and TARA 3, and generically referred to as gyros) which until March of 2024 were all used in rate estimation as an operational workaround (dubbed “corrector-gyro”) of a software defect discovered in 2007. TARA 1 performance degraded throughout 2023 and 2024, making it an unreliable rate source. It was determined that shifting TARA 1 to be the corrector-gyro and using mainly TARAs 2 and 3, with the existing flight software (FSW) defect, would not meet performance requirements for science operations. Rather the FSW was patched to remove the defect found in 2007. This patch was delivered by the vendor in 2009, but was not fully tested or installed at that time. A decision was made in 2024 to install the patch despite limited simulation and testing capabilities. The problem facing the team was to come up with a set of alignment parameters that would work with the new patch, using data from the spacecraft operating normally in the old configuration. Calibration activities would have been possible in either the old or new FSW configuration, but were ultimately deemed unnecessary, saving staff time and pre-serving time on the spacecraft for science data collection. This paper describes the old and new FSW configurations related to gyro processing and alignment, and how the raw gyro and star tracker data from normal operation were used with a multidimensional unconstrained nonlinear minimization in MATLAB (Nelder-Mead1) to produce a fully calibrated set of gyro alignment parameters compatible with the patched FSW. Flight data is presented showing that not only did the process work, it improved performance significantly, rivaling the best slew performance of the mission to date.

MATLAB↗

An Inertial Dual-State State Estimator for Precision Planetary Landing with Hazard Detection and Avoidance

The navigation filter architecture successfully deployed on the Morpheus flight vehicle is presented. The filter was developed as a key element of the NASA Autonomous Landing and Hazard Avoidance Technology (ALHAT) project and over the course of 15 free fights was integrated into the Morpheus vehicle, operations, and flight control loop. Flight testing completed by demonstrating autonomous hazard detection and avoidance, integration of an altimeter, surface relative velocity (velocimeter) and hazard relative navigation (HRN) measurements into the onboard dual-state inertial estimator Kalman flter software, and landing within 2 meters of the vertical testbed GPS-based navigation solution at the safe landing site target. Morpheus followed a trajectory that included an ascent phase followed by a partial descent-to-landing, although the proposed filter architecture is applicable to more general planetary precision entry, descent, and landings. The main new contribution is the incorporation of a sophisticated hazard relative navigation sensor-originally intended to locate safe landing sites-into the navigation system and employed as a navigation sensor. The formulation of a dual-state inertial extended Kalman filter was designed to address the precision planetary landing problem when viewed as a rendezvous problem with an intended landing site. For the required precision navigation system that is capable of navigating along a descent-to-landing trajectory to a precise landing, the impact of attitude errors on the translational state estimation are included in a fully integrated navigation structure in which translation state estimation is combined with attitude state estimation. The map tie errors are estimated as part of the process, thereby creating a dual-state filter implementation. Also, the filter is implemented using inertial states rather than states relative to the target. External measurements include altimeter, velocimeter, star camera, terrain relative navigation sensor, and a hazard relative navigation sensor providing information regarding hazards on a map generated on-the-fly.

Bishop, Robert H.↗

ProZES: the methodology and software tool for assessment of assigned share of radiation in probability of cancer occurrence

ProZES is a software tool for estimating the probability that a given cancer was caused by preceding exposure to ionising radiation. ProZES calculates this probability, the assigned share, for solid cancers and hematopoietic malignant diseases, in cases of exposures to low-LET radiation, and for lung cancer in cases of exposure to radon. User-specified inputs include birth year, sex, type of diagnosed cancer, age at diagnosis, radiation exposure history and characteristics, and smoking behaviour for lung cancer. Cancer risk models are an essential part of ProZES. Linking disease and exposure to radiation involves several methodological aspects, and assessment of uncertainties received particular attention. ProZES systematically uses the principle of multi-model inference. Models of radiation risk were either newly developed or critically re-evaluated for ProZES, including dedicated models for frequent types of cancer and, for less common diseases, models for groups of functionally similar cancer sites. The low-LET models originate mostly from the study of atomic bomb survivors in Hiroshima and Nagasaki. Risks predicted by these models are adjusted to be applicable to the population of Germany and to different time periods. Adjustment factors for low dose rates and for a reduced risk during the minimum latency time between exposure and cancer are also applied. The development of the methodology and software was initiated and supported by the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (BMU) taking up advice by the German Commission on Radiological Protection (SSK, Strahlenschutzkommission). These provide the scientific basis to support decision making on compensation claims regarding malignancies following occupational exposure to radiation in Germany.

97 MATHEMATICS AND COMPUTING↗

The NASA Analogy Software Cost Model: A Web-Based Cost Analysis Tool

This paper provides an overview of the many new features and algorithm updates in the release of the NASA Analogy Software Cost Tool (ASCoT). ASCoT is a web-based tool that provides a suite of estimation tools to support early lifecycle NASA Flight Software analysis. ASCoT employs advanced statistical methods such as Cluster Analysis to provide an analogy based estimate of software delivered lines of code and development effort, a regression based Cost Estimating Relationships (CER) model that estimates cost (dollars), and a COCOMO II based estimate. The ASCoT algorithms are designed to primarily work with system level inputs such as mission type (earth orbiter vs. planetary vs. rover), the number of instruments, and total mission cost. This allows the user to supply a minimal number of mission-level parameters which are better understood early in the life-cycle, rather than a large number of complex inputs.

Hihn, Jairus↗

MO-F-CAMPUS-I-01: Accuracy of Radiologists Interpretation of Mammographic Breast Density

Purpose: Several commercial and non-commercial software and techniques are available for determining breast density from mammograms. However, where mandated by law the breast density information communicated to the subject/patient is based on radiologist’s interpretation of breast density from mammograms. Several studies have reported on the concordance among radiologists in interpreting mammographic breast density. In this work, we investigated the accuracy of radiologist’s interpretation of breast density. Methods: Volumetric breast density (VBD) determined from 134 unilateral dedicated breast CT scans from 134 subjects was considered the truth. An MQSA-qualified study radiologist with more than 20 years of breast imaging experience reviewed the DICOM “for presentation” standard 2-view mammograms of the corresponding breasts and assigned BIRADS breast density categories. For statistical analysis, the breast density categories were dichotomized in two ways; fatty vs. dense breasts where “fatty” corresponds to BIRADS breast density categories A/B, and “dense” corresponds to BIRADS breast density categories C/D, and extremely dense vs. fatty to heterogeneously dense breasts, where extremely dense corresponds to BIRADS breast density category D and BIRADS breast density categories A through C were grouped as fatty to heterogeneously dense breasts. Logistic regression models (SAS 9.3) were used to determine the association between radiologist’s interpretation of breast density and VBD from breast CT, from which the area under the ROC (AUC) was determined. Results: Both logistic regression models were statistically significant (Likelihood Ratio test, p<0.0001). The accuracy (AUC) of the study radiologist for classification of fatty vs. dense breasts was 88.4% (95% CI: 83–94%) and for classification of extremely dense breast was 94.3% (95% CI: 90–98%). Conclusion: The accuracy of the radiologist in classifying dense and extremely dense breasts is high. Considering the variability in VBD estimates from commercial software, the breast density information communicated to the patient should be based on radiologist’s interpretation. This work was supported in part by NIH R21 CA176470 and R21 CA134128. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Parametric analysis on optimized design of hybrid solar power plants

There is increasing interest in utility-scale solar power plants with storage which can flexibly dispatch renewable energy to the grid. However, plant design possesses many degrees of freedom and non-obvious trade-offs in performance. Software tools can estimate or optimize the performance of a specific plant configuration under market and weather conditions of interest; the associated cost parameters and operating assumptions strongly influence estimates of plant performance and decisions regarding optimal sizing. We employ the National Renewable Energy Laboratory's Hybrid Optimization and Performance Platform, which incorporates optimal dispatch when evaluating plant performance, and investigate the sensitivity to weather and market conditions, operating limitations, and the presence of a capacity-based incentive. We demonstrate changes in plant performance and optimal sizing with respect to these inputs and discuss implications. Here results show that PV-with-battery designs are more profitable under our assumptions, but that designs including a concentrated solar power (CSP) system produce significantly greater annual energy; and that CSP-with-thermal energy storage designs maximizing the benefit-to-cost ratio have an input-dependent linear relationship between the CSP field solar multiple and the hours of storage as the project budget varies.

14 SOLAR ENERGY↗

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Oscillator-Qubit Quantum Processors: Instruction Set Architectures, Abstract Machine Models, and Applications

This tutorial offers a pedagogical guide to hybrid quantum processors that integrate discrete-variable (DV) qubits and continuous-variable (CV) oscillators. Aimed at computer scientists, engineers, and physicists, it provides an overview of the experimental, algorithmic, and architectural aspects of this novel and rapidly developing hardware model. Experimental realizations of this model include superconducting, trapped-ion, and neutral-atom platforms. By combining DV and CV components, hybrid oscillator-qubit processors enable a powerful new paradigm that offers complementary strengths for quantum control, error correction, computation, and simulation. Working toward the goal of a full-stack system connecting applications to CV-DV hardware, we define and formulate abstract machine models and instruction set architectures. These essential abstractions enable codesign of hardware and software, and resource estimation for exploring the potential of current and future hardware for computational and simulation tasks. Using these abstractions, we present both new and existing examples that illustrate the benefits of hybrid CV-DV processors relative to traditional DV-only hardware in computation as well as quantum simulation of physical models. Examples include algorithms for transferring states between DV and CV systems, performing the quantum Fourier transform, and simulation of lattice gauge theories. Relative to qubit-only hardware, the bosonic degrees of freedom natively available in hybrid architectures can substantially reduce the circuit complexity of simulations for physical models containing bosons. A key technique is the extension of quantum signal processing ideas to CV-DV systems. This work is intended to serve as a timely and comprehensive guide to this relatively unexplored yet promising approach to quantum computation and to provide a road map to guide future development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and analysis of magnetic coil for relativistic magnetron

This paper presents the design of magnetic coil for relativistic magnetron (RM) for LIA (Linear Induction Accelerator)-400 systems. Vacuum improves the efficiency of RM for HPM generation. Magnetic field in RM is very critical parameter and should be nearly constant in the active region. Typical coils are helical in nature, which have multi turns of varying radius. Magnetic field calculation of such coils with basic equations of Helmholtz coils or solenoid with mean radius can only give estimation. Field computational softwares like CST require small mesh size and boundary at very far so consume large memory and take very much time. Helical coils are simplified such that the basic law of magnetic field calculation i.e. Bio-Savart law can be applied with less complexity. Pairs of spiral coils have been analyzed for magnetic field and Lorenz's force. The approach is field experimentally validated. (author)

43 PARTICLE ACCELERATORS↗

Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA

Purpose: The purpose of this work is to explore the usefulness of the gamma passing rate metric for per-patient, pretreatment dose QA and to validate a novel patient-dose/DVH-based method and its accuracy and correlation. Specifically, correlations between: (1) gamma passing rates for three 3D dosimeter detector geometries vs clinically relevant patient DVH-based metrics; (2) Gamma passing rates of whole patient dose grids vs DVH-based metrics, (3) gamma passing rates filtered by region of interest (ROI) vs DVH-based metrics, and (4) the capability of a novel software algorithm that estimates corrected patient Dose-DVH based on conventional phan-tom QA data are analyzed. Methods: Ninety six unique ''imperfect'' step-and-shoot IMRT plans were generated by applying four different types of errors on 24 clinical Head/Neck patients. The 3D patient doses as well as the dose to a cylindrical QA phantom were then recalculated using an error-free beam model to serve as a simulated measurement for comparison. Resulting deviations to the planned vs simulated measured DVH-based metrics were generated, as were gamma passing rates for a variety of difference/distance criteria covering: dose-in-phantom comparisons and dose-in-patient comparisons, with the in-patient results calculated both over the whole grid and per-ROI volume. Finally, patient dose and DVH were predicted using the conventional per-beam planar data as input into a commercial ''planned dose perturbation'' (PDP) algorithm, and the results of these predicted DVH-based metrics were compared to the known values. Results: A range of weak to moderate correlations were found between clinically relevant patient DVH metrics (CTV-D95, parotid D{sub mean}, spinal cord D1cc, and larynx D{sub mean}) and both 3D detector and 3D patient gamma passing rate (3%/3 mm, 2%/2 mm) for dose-in-phantom along with dose-in-patient for both whole patient volume and filtered per-ROI. There was considerable scatter in the gamma passing rate vs DVH-based metric curves. However, for the same input data, the PDP estimates were in agreement with actual patient DVH results. Conclusions: Gamma passing rate, even if calculated based on patient dose grids, has generally weak correlation to critical patient DVH errors. However, the PDP algorithm was shown to accurately predict the DVH impact using conventional planar QA results. Using patient-DVH-based metrics IMRT QA allows per-patient dose QA to be based on metrics that are both sensitive and specific. Further studies are now required to analyze new processes and action levels associated with DVH-based metrics to ensure effectiveness and practicality in the clinical setting.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

MO-D-213-04: The Proximity to the Skin of PTV Affects PTV Coverage and Skin Dose for TomoTherapy

Purpose: The proximity to the skin surface of the PTV for the patients with skin disease could be a concern in terms of the PTV coverage and actual surface dose (SD). IMRT optimization algorithms increase the beam intensity close to the skin in order to compensate for lack of scattering material, leading to enhanced SD but potential hot spots. This study aims to investigate the effect of PTV proximity to the skin on planning and measured SD Methods: All measurements were done for 6 MV X-ray beam of Helical TomoTherapy. An anthropomorphic phantom was scanned in a CT simulator in a routine manner with thermoplastic mask immobilization. PTVs were created with varying distances to the skin of 0 mm -(PTV1), 1 mm- (PTV2), 2 mm-(PTV3) and 3 mm-(PTV4). Also, a 5 mm bolus was used with PTV1 (PTV5). All planning constraints were kept the same in all studies (hard constraint: 95% of the prescription dose covered 95% of the PTV). Gafchromic film (EBT3) was placed under the mask on the phantom surface, and the resulting dose was estimated using RIT software. Results: Optimizing the dose using different PTVs lead to average planned target doses of 10.8, 10.3, 10.2, 10.3 and 10.0 Gy, with maximum doses 12.2, 11.2, 11.1, 11.1 and 10.0 Gy for PTV1, PTV2, PTV3, PTV4 and PTV5, respectively. EBT3 measurements indicated a significant decrease of SD with skin distance by 12.7% (PTV1), 21.9% (PTV2), 24.8% (PTV3) and 28.4% (PTV4) comparing to prescription dose. Placement of a 5 mm bolus on the phantom surface resulted in a SD close to prescribed (+0.5%). Conclusion: This work provides a clear demonstration of the relationship between the skin dose and the PTV to the skin distance. The results indicate the necessity of a bolus even for TomoTherapy when high skin dose is required.

60 APPLIED LIFE SCIENCES↗

scANN

SAND2025-00656O scANN, also known as sampling by coinflips artificial neural networks, is a software tool that estimates uncertainty in artificial intelligence by performing Monte Carlo analysis on the weight matrices of feedforward neural networks. This computationally intensive process aims to explore the potential value added by future probabilistic hardware. The program’s output helps researchers gain insights into how probabilistic neural networks work. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

Platform Li-Ion Battery Risk Assessment Tool (CRADA Final Report)

Creare was awarded a Phase 1 STTR contract from the US Office of Naval Research, with a seven month period of performance from 6/28/2010 to 1/28/2011. The objectives of the STTR were to determine the feasibility of developing a software package for estimating reliability of battery packs, and develop a user interface to allow the designer to assess the overall impact on battery packs and host platforms for cell-level faults. NREL served as sub-tier partner to Creare, providing battery modeling and battery thermal safety expertise.

25 ENERGY STORAGE↗

A Computer Design Tool for Ceramic Receivers

Gen3 solar receivers and other components will experience a combination of high temperatures and high stress caused by thermal stress and internal pressure. Under these conditions metallic components, even those manufactured from nickel-based superalloys, have poor reliability. Engineering ceramics could be a solution, as these materials have excellent high temperature strength. However, accurately assessing the reliability of a ceramic component operating in these conditions requires an entirely different approach compared to metallic materials. This paper describes the implementation of statistical models for evaluating the reliability of high temperature ceramic components in srlife – an open-source software package for estimating the life of high temperature concentrating solar power equipment. This new capability allows users to make fair comparisons between competing metallic and ceramic component designs and to accurately assess the plant efficiency and economics of ceramic solar receivers and other components.

Messner, Mark (ORCID:0000000200404385)↗

Time-Dependent Failure Assessment of Ceramic Receivers

The outlet temperature targets for Gen 3 Concentrating Solar Power (CSP) systems pose a significant challenge to the structural reliability of high temperature metallic components, including those manufactured from nickel-based superalloys. Advanced ceramics present a potential solution due to their excellent high-temperature strength. However, accurate assessment of ceramic components requires an entirely different approach compared to metallic components. This paper describes the implementation of time-dependent reliability analysis of ceramic components in srlife – an open-source software package for estimating the life of high temperature CSP components. This new capability will allow high temperature CSP designers to make fair comparisons between competing metallic and ceramic designs and accurately assess the performance of different ceramic materials for CSP receivers and other components. The current version of the tool is available at https://github.com/Argonne-National-Laboratory/srlife.

Barua, Bipul (ORCID:0000000247184113)↗

MAGSAT for geomagnetic studies over Indian region

The external current field due to ring current and the associated induced part were removed. Adjacent passes over India were elected and best function to account for the trend correction was estimated. The UPCON software sent from Canada was made operational and features of equatorial electrojet were studied from MAGSAT records.

Rastogi, R. G.↗

Life cycle cost modeling of conceptual space vehicles

This paper documents progress to date by the University of Dayton on the development of a life cycle cost model for use during the conceptual design of new launch vehicles and spacecraft. This research is being conducted under NASA Research Grant NAG-1-1327. This research effort changes the focus from that of the first two years in which a reliability and maintainability model was developed to the initial development of a life cycle cost model. Cost categories are initially patterned after NASA's three axis work breakdown structure consisting of a configuration axis (vehicle), a function axis, and a cost axis. The focus will be on operations and maintenance costs and other recurring costs. Secondary tasks performed concurrent with the development of the life cycle costing model include continual support and upgrade of the R&M model. The primary result of the completed research will be a methodology and a computer implementation of the methodology to provide for timely cost analysis in support of the conceptual design activities. The major objectives of this research are: to obtain and to develop improved methods for estimating manpower, spares, software and hardware costs, facilities costs, and other cost categories as identified by NASA personnel; to construct a life cycle cost model of a space transportation system for budget exercises and performance-cost trade-off analysis during the conceptual and development stages; to continue to support modifications and enhancements to the R&M model; and to continue to assist in the development of a simulation model to provide an integrated view of the operations and support of the proposed system.

Ebeling, Charles↗