Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Long life assurance study for manned spacecraft long life hardware. Volume 3: Long life assurance studies of components

The guidelines for selecting hardware to be used in manned spacecraft to obtain a five year operational lifetime without maintenance were developed. An analysis was conducted on the design, application, failure mechanisms, manufacturing processes and controls, screen and burn-in techniques, and quality control of hardware items. The equipment considered for evaluation include: (1) electric motors and bearings; (2) accelerometers; (3) gyroscopes and bearings; (4) compressors and pumps, (5) magnetic tape recorders; (6) plumbing components and tubing; (7) check valves; (8) pressure regulators and solenoid valves; (9) thermal control valves; (10) pressure vessels and positive expulsion devices; (11) nickel cadmium batteries; and (12) transducers.

Source record↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

Operational Parameter Database for Molten Salt Thermal Energy Storage Tank Modeling

The second generation of concentrated solar power (CSP) plants is characterized by the use of a central receiver (either cavity or external), two molten nitrate salt tanks (60 wt.% NaNO 3 and 40 wt.% KNO 3 ), and a steam Rankine power-generation cycle connected through a primary heat exchanger. Molten salt thermal energy storage (TES) tanks have been widely deployed in commercial CSP plants worldwide and have been essential for increasing plant dispatchability and capacity factor, while also reducing the levelized cost of electricity (LCOE). These systems enable energy storage at the gigawatt-hour scale, typically providing 6 to 17 hours of storage duration. Despite being a commercial technology, the multiple failures observed after only a few months or years of operation in plants around the world demonstrate the technology's relative infancy and highlight the need for further research to improve its reliability. The National Laboratory of the Rockies (NLR), in collaboration with industry partners and academic and research institutions, has been leading multiple projects funded by the U.S. Department of Energy (DOE). These projects focus on addressing molten salt tank failures by improving tank design and welding fabrication practices, evaluating new alloys and weld fillers, and providing guidelines for tank commissioning and safe operation. In particular, this report presents modeling results on the effect of key tank operation parameters during 60 minutes of operation, including the mass flow rate and temperature of the salt inflow, tank salt inventory temperature, and inventory level for a representative molten salt tank design. These results form a database of tank operation behaviors that captures the effects of each specific parameter during charging, charging/discharging, and discharging processes.

14 SOLAR ENERGY↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Design guide: Designing and building high voltage power supplies, volume 2

This report contains an accumulation of publications and analyses aimed at developing guidelines for improving both high voltage and low voltage power supplies for the U.S. Air Force systems command. It is the intent of the report to supply good design and manufacturing techniques for the packaging and the building of high quality, reliable, long-life power supplies. These data are based on the wealth of engineering practices established by design and manufacturing engineers. The contents are: Fundamentals of Insulation: Gases, Liquid Dielectrics, Solid Insulation; Environment: Pressure, Particulates, Environmental Interactions with Space Power Systems, Surface Charging, System Design Criteria; Configuration and Design Data: Designs, Transients, Grounding and Bonding, Thermal Control; Materials and Processes: Insulation, Processes, Process Variables; Manufacturing: Yield, Government and Industrial Survey, Analysis, Problem Areas and Suggested Solutions, Designs That Have Worked in High Voltage Equipment, Manufacturing Summary; and Tests: Performance, Insulation Tests, Materials Testing, Component and Equipment Tests, Performance Testing, Facility and Environment, Accelerated Life Test; Maintenance and Repair: Maintenance, Test Sets, Pilots and Crewmen, Air Logistic Centers, Design Problem Recommendations.

W G Dunbar↗

Effect of the Ionic Liquid Structure on the Melt Processability of Polyacrylonitrile Fibers

The production of high-strength carbon fibers is an energy-intensive process, where a significant cost involves the wet or dry-spinning of polyacrylonitrile (PAN) fiber precursors. Melt-spinning PAN fibers would allow for significant reduction in the production cost and production hazards. Ionic liquids (ILs) are an attractive fiber-processing medium because of their negligible vapor pressure and low toxicity. In addition, they are carbon-forming precursors; upon carbonization, residual ILs can enhance the carbon yield, although primarily useful for plasticized melt-spinning of PAN precursor fibers. Here, we investigated the influence of the molecular structure of ILs and the control of plasticizing interactions with PAN during melt-spinning. The structural, thermal, and mechanical properties of the melt-spun PAN fibers were obtained by a combination of various characterization methods, such as differential scanning calorimetry, thermogravimetric analysis, Fourier transform infrared spectroscopy, scanning electron microscopy, X-ray diffraction, and mechanical testing. These results demonstrated that the IL structure and counteranions influence the PAN fiber formation. More specifically, ILs containing bromide counteranions produced PAN precursor fibers with increased mechanical properties compared to ILs containing chloride anions. Our research can provide a foundation to understand the influence of ILs on melt-spinning of PAN fibers and provides us the guidelines for a higher cost-/energy-efficient production of PAN-based carbon fibers.

36 MATERIALS SCIENCE↗

Quantitative non-destructive testing

The work undertaken during this period included two primary efforts. The first is a continuation of theoretical development from the previous year of models and data analyses for NDE using the Optical Thermal Infra-Red Measurement System (OPTITHIRMS) system, which involves heat injection with a laser and observation of the resulting thermal pattern with an infrared imaging system. The second is an investigation into the use of the thermoelastic effect as an effective tool for NDE. As in the past, the effort is aimed towards NDE techniques applicable to composite materials in structural applications. The theoretical development described produced several models of temperature patterns over several geometries and material types. Agreement between model data and temperature observations was obtained. A model study with one of these models investigated some fundamental difficulties with the proposed method (the primitive equation method) for obtaining diffusivity values in plates of thickness and supplied guidelines for avoiding these difficulties. A wide range of computing speeds was found among the various models, with a one-dimensional model based on Laplace's integral solution being both very fast and very accurate.

Welch, C. S.↗

Chemistry, Structure, and Function of Lone Pairs in Extended Solids

The lone pair has been a known feature of the electronic structure of molecules for over 100 years. Beginning with the pioneering work of Lewis and others that was later developed into useful guidelines for predicting molecular structure, lone pairs and their steric consequences are now taught at the very earliest stages of a chemistry education. In the crystalline solid state, lone pairs have perhaps had a less visible yet equally consequential role, with a significant impact on a range of properties and functionalities. Important properties associated with s 2 electron-derived lone pairs include their role in creating conditions favorable for ion transport, in the formation and correlation of local dipoles and the resulting polar behavior leading to ferroics and multiferroics, in increasing the refractive index of glass, in reducing the thermal conductivity of thermoelectric materials, and in breaking local symmetry permitting second-harmonic light generation.. In recent years, the role of the lone pair in developing the electronic structure of some topological quantum materials has also been recognized. While structural distortions due to lone pairs have traditionally been characterized through their crystallography, recent advances in scattering and spectroscopy have revealed the presence of local lone pair-driven distortions that do not correlate over long length scales. The role of these crystallographically “hidden” lone pairs, their detection, and their impact on properties have become a growing body of work in the literature. Hidden lone pairs are an effective argument for considering a role for lone pairs that goes beyond their being objects that occupy space in the coordination polyhedra of cations. This Account introduces the chemistry of lone pairs in extended crystalline solids, including a discussion of when they are stereochemically active, how they manifest in the structure, and how their chemistry can be tuned by the chemical environment around them. Eventually, all of these factors work in unison to help develop and tune properties of interest. Certain specific examples of structure–property relationships in materials that are driven by lone pair behavior are described here, including the potential impact of lone pairs on the optical and electronic properties of hybrid halide perovskite compounds that are relevant to their photovoltaic applications. Here, we highlight the role of lone pairs in the dielectric behavior of geometrically frustrated pyrochlores, the temperature-dependent optoelectronic behavior of halide perovskites, the polar phase transitions in lead-free ferroelectric perovskites, and the compositional insulator-to-metal transition in ruthenium pyrochlores. The theme underpinning this Account is that the lone pair can be considered to be a powerful design element for a broad range of material function.

36 MATERIALS SCIENCE↗

Process-informed adsorbent design guidelines for direct air capture

Direct air capture using solid adsorbents is a proven technology critical to reducing our net greenhouse gas emissions to zero and beyond. Currently, academic research into the technology mainly focuses on the development of new adsorbents. However, there is a discord between the adsorbent design and process performance. Many materials scientists focus on maximising metrics such as the CO 2 capacity of their adsorbent. Here, we combine detailed process modelling, machine learning, and extensive global sensitivity analysis, which entails varying all of the model parameters together, on a direct air capture process to show that the dry CO 2 adsorption capacity does not influence process performance for an amine-functionalised adsorbent operating in a temperature vacuum swing adsorption (TVSA) process, while it is important in a steam-assisted TVSA (S-TVSA) process. In fact, adsorption kinetics, density, and thermal conductivity are all critical attributes to obtaining a low energy penalty and reduced costs. The analysis also highlights the importance of heat transfer, directing process engineers to (alternative) adsorber designs that maximise this. By an in-depth evaluation of how process performance indicators are affected by materials properties and process operating parameters, this work provides guidance to both material scientists and process engineers towards the design of a “unicorn adsorbent” and intensified DAC processes. This will improve the performance of solid adsorbent direct air capture and help drive down the costs of this vital technology to avert the worst impacts of climate change.

42 ENGINEERING↗

Ducted Assembly Steady-State Heat Transfer Software (DASSH)

The Ducted Assembly Steady-State Heat transfer software (DASSH) is being developed at Argonne National Laboratory to perform a steady-state thermal fluids calculation to determine the coolant flow and temperature distribution for a hexagonal reactor core configuration with ducted assemblies. DASSH is intended to be used in the early stages of the reactor design process when assembly components can be undefined or are undergoing considerable design changes. DASSH provides a rapid assessment of the temperature and flow distribution to allow quick characterization of the system and identification of problem areas. This document is a guide for DASSH users. It summarizes the core capabilities of DASSH and highlights differences between DASSH and SE2-ANL. Instructions for obtaining and installing DASSH are provided along with some guidelines and recommendations for newer Python users. It covers the structure of the input file, provides directions for running DASSH, describes the various output files produced by the code, and provides instructions for visualizing data. Examples demonstrating various DASSH options are included. DASSH is under active development, so it is anticipated that this guide will grow and evolve as the code is updated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Thermal Characterization of a Fully-Passive Wireless Backscattering Neuro-Recording Microsystem

We present analytical and experimental thermal characteristics of a battery-less, fully-passive wireless backscattering microsystem for recording of neuropotentials. A major challenge for cortically implantable microsystems involves minimizing the heat dissipated by on-chip circuitry, which can lead to permanent brain damage. Therefore, knowledge of temperature changes induced by implantable microsystems while in operation is of utmost importance. In this work, a discrete diode appended to the neuro-recording microsystem has been used to indirectly monitor the aforesaid temperature changes. Using this technique, the maximum temperature rise measured for the microsystem while in operation was 0.15 +/- 0.1 C, which is significantly less than current safety guidelines. Specific absorption ratio (SAR) due to the microsystem was also computed to further demonstrate fully-passive functionality of the neuro-recording microsystem.

Schwerdt, H. N.↗

Crystalline Mesoporous Complex Oxides: Porosity-Controlled Electromagnetic Response

A colloidal--amphiphile--templated growth is developed to synthesize mesoporous complex oxides with highly crystalline frameworks. Organosilane-containing colloidal templates can convert into thermally stable silica that prevents the overgrowth of crystalline grains and the collapse of the mesoporosity. Using ilmenite CoTiO 3 as an example, the high crystallinity and the extraordinary thermal stability of its mesoporosity are demonstrated at 800 °C for 48 h under air. This synthetic approach is general and applicable to a series of complex oxides that are not reported with mesoporosity and high crystallinity, such as NiTiO 3 , FeTiO 3 , ZnTiO 3 , Co 2 TiO 4 , Zn 2 TiO 4 , MgTi 2 O 5 , and FeTi 2 O 5 . Those novel materials make it possible to build up correlations between mesoscale porosity and surface-sensitive physicochemical properties, e.g., electromagnetic response. For mesoporous CoTiO 3 , there is a 3 K increase of its antiferromagnetic ordering temperature, compared with that of nonporous one. Lastly, this finding provides a general guideline to design mesoporous complex oxides that allow exploring their unique properties different from bulk materials.

36 MATERIALS SCIENCE↗

Preliminary base heating environments for a generalized ALS LO2/LH2 launch vehicle, appendix 1 and 2

A secondary objective of contract NAS8-39141 is to provide base heating assessments, as required, to support Advanced Launch System (ALS) preliminary launch vehicle and propulsion system design studies. The ALS propulsion systems integration working group meeting (No. 3) recently completed in San Diego, California, focused attention on the need for base heating environment determination to provide preliminary requirements for LO2/LH2 propulsion systems currently being considered for ALS. We were requested to provide these environments for a range of possible propellant mixture and nozzle area ratios. Base heating environments can only be determined as a function of altitude when the engine operating conditions and vehicle base region geometry (engine arrangement) are known. If time dependent environments are needed to assess thermal loads, a trajectory must also be provided. These parameters are not fixed at this time since the ALS configurations and propulsion operating conditions are varied and continue to be studied by Phase B contractors. Therefore, for this study, a generalized LO2/LH2 system was selected along with a vehicle configuration consisting of a seven-engine booster and a three-engine core. MSFC provided guidance for the selection. We also selected a limited number of body points on the booster and core vehicles and engines for the environment estimates. Environments at these locations are representative of maximum heating conditions in the base region and are provided as a function of altitude only. Guidelines and assumptions for this assessment, methodology for determining the environments, and preliminary results are provided in this technical note. Refinements in the environments will be provided as the ALS design matures.

Bender, Robert L.↗

Energy Master Planning for Resilient Public Communities—Best Practices from U.S. Military Installations

Until recently, most planners at military installations addressed energy systems for new facilities on an individual facility basis without consideration of community-wide goals relevant to energy sources, renewables, storage, or future energy generation needs. Building retrofits of public buildings typically do not address energy needs beyond the minimum code requirements making it difficult, if not impossible, to achieve community-level targets on a building-by-building basis. Planning on the basis of cost and general reliability may also fail to deliver community-level resilience. For example, many building code requirements focus on hardening to specific threats, but in a multi-building community, only a few of these buildings may be mission-critical. Over the past two decades, the frequency and duration of regional power outages and water utility disruptions from weather, man-made events, and aging infrastructure have increased. Major disruptions of electric and thermal energy have degraded critical mission capabilities and caused significant economic impacts. In 2016, the U.S. Department of Defense issued guidance that each Service (Army, Navy, Air Force, Marines) complete comprehensive energy plans for the installations that consumed 75% of total building energy. Guidance was updated in 2017 to include metrics for energy resilience, and in some cases, water. This paper describes how community level quantitative and qualitative resilience analysis and metrics have been incorporated into community energy and water planning best practices for military installations in three geographically diverse locations. It is based on research performed under the International Energy Agency’s “Energy in Buildings and Communities Program Annex 73,” focusing on development of guidelines and tools that support the planning of Net Zero Energy Resilient Public Communities as well as research performed under the Department of Defense Environmental Security Technology Certification Program project EW18-D1- 5281, “Technologies Integration to Achieve Resilient, Low- Energy Military Installations.” The first case study reviews progress made on an energy and water planning study conducted at Fort Bliss, Texas. The second and third describes planning conducted at Fort Bragg, North Carolina and the Joint Region Marianas, Guam, respectively, under the updated guidance from 2017 regarding energy and water resilience. Analysis methods, key metrics, and key infrastructure and operational constraints are described, as well as technical, economic and business concepts used during the planning process.

Urban, Angela B.↗

International Space Station (ISS) External Thermal Control System (ETCS) Loop A Pump Module (PM) Jettison Options Assessment

On December 11, 2013, the International Space Station (ISS) experienced a failure of the External Thermal Control System (ETCS) Loop A Pump Module (PM). To minimize the number of extravehicular activities (EVA) required to replace the PM, jettisoning the faulty pump was evaluated. The objective of this study was to independently evaluate the jettison options considered by the ISS Trajectory Operations Officer (TOPO) and to provide recommendations for safe jettison of the ETCS Loop A PM. The simulation selected to evaluate the TOPO options was the NASA Engineering and Safety Center's (NESC) version of Program to Optimize Simulated Trajectories II (POST2) developed to support another NESC assessment. The objective of the jettison analysis was twofold: (1) to independently verify TOPO posigrade and retrograde jettison results, and (2) to determine jettison guidelines based on additional sensitivity, trade study, and Monte Carlo (MC) analysis that would prevent PM recontact. Recontact in this study designates a propagated PM trajectory that comes within 500 m of the ISS propagated trajectory. An additional simulation using Systems Tool Kit (STK) was run for independent verification of the POST2 simulation results. Ultimately, the ISS Program removed the PM jettison option from consideration. However, prior to the Program decision, the retrograde jettison option remained part of the EVA contingency plan. The jettison analysis presented showed that, in addition to separation velocity/direction and the atmosphere conditions, the key variables in determining the time to recontact the ISS is highly dependent on the ballistic number (BN) difference between the object being jettisoned and the ISS.

Murri, Daniel G.↗

Guidelines for predicting stress in cemented doublets undergoing temperature change

This work explores quick predictive methods for calculating potentially risky stresses and deflections in cemented doublets experiencing temperature change that agree well with finite element analysis. There are three failure modes of interest: cohesive failure of the adhesive, delamination (surface bond failure or debonding), and glass fracture. Adhesive theory, confirmed by finite element analysis, predicts stress singularities that complicate interpretation of the stress calculations. The presence of a stress singularity indicates the breakdown of linear elastic assumptions, but damage initiation and stress singularities are related. The authors find that geometry details near a bond edge can exacerbate or minimize damage initiation and stress concentrations. Because the interpretation of the stress results is complicated, the authors investigated predicted stresses in doublets that have been successfully tested between -40 and 85 °C. This study found that the product (ΔT ∙ Δα) should be less than 189 ppm, where ΔT is the temperature excursion and Δα is the difference in glass coefficient of thermal expansion. If the product (ΔT ∙ Δα) is equal to or greater than 189 ppm, further analysis and testing is warranted. But the authors also show that the fabrication process can significantly influence stress failure, particularly with large diameter doublets.

47 OTHER INSTRUMENTATION↗

Guidelines for predicting stress in cemented doublets undergoing temperature change

This work explores quick predictive methods for calculating potentially risky stresses and deflections in cemented doublets experiencing temperature change that agree well with finite element analysis. There are three failure modes of interest: cohesive failure of the adhesive, delamination (surface bond failure or debonding), and glass fracture. Adhesive theory, confirmed by finite element analysis, predicts stress singularities that complicate interpretation of the stress calculations. The presence of a stress singularity indicates the breakdown of linear elastic assumptions, but damage initiation and stress singularities are related. The authors find that geometry details near a bond edge can exacerbate or minimize damage initiation and stress concentrations. Because the interpretation of the stress results is complicated, the authors investigated predicted stresses in doublets that have been successfully tested between -40 and 85 °C. This study found that the product (∆T ∙ ∆α) should be less than 189 ppm, where ∆T is the temperature excursion and ∆α is the difference in glass coefficient of thermal expansion. If the product (∆T ∙ ∆α) is equal to or greater than 189 ppm, further analysis and testing is warranted. But the authors also show that the fabrication process can significantly influence stress failure, particularly with large diameter doublets

42 ENGINEERING↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗