Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Dynamic STEM-EELS for single-atom and defect measurement during electron beam transformations

This study introduces the integration of dynamic computer vision–enabled imaging with electron energy loss spectroscopy (EELS) in scanning transmission electron microscopy (STEM). This approach involves real-time discovery and analysis of atomic structures as they form, allowing us to observe the evolution of material properties at the atomic level, capturing transient states traditional techniques often miss. Rapid object detection and action system enhances the efficiency and accuracy of STEM-EELS by autonomously identifying and targeting only areas of interest. This machine learning (ML)–based approach differs from classical ML in that it must be executed on the fly, not using static data. We apply this technology to V-doped MoS 2 , uncovering insights into defect formation and evolution under electron beam exposure. This approach opens uncharted avenues for exploring and characterizing materials in dynamic states, offering a pathway to increase our understanding of dynamic phenomena in materials under thermal, chemical, and beam stimuli.

47 OTHER INSTRUMENTATION↗

Capture Cavities for the CW Polarized Positron Source Ce+BAF

The initial design of the capture cavities for a continuous wave (CW) polarized positron beam for the Continuous Electron Beam Accelerator Facility (CEBAF) up-grade at Jefferson Lab is presented. A chain of standing wave multi-cell copper cavities inside a solenoid channel are selected to capture positrons in CW mode. The cavity shunt impedance is surveyed by tuning the cavity geometry while considering accommodating large phase space distribution positron beams with large beam pipe radius while ensuring a large enough passband mode separation. The RF field wall loss power and maximum wall loss power density are considered in cavity and waveguide design. A range of design parameters are given for larger system optimization when the capture cavities are considered together with thermal calculation and beam dynamics in next phase of work.

Wang, S.↗

Enhanced Monte Carlo Simulations for Electron Energy Loss Mitigation in Real-Space Nanoimaging of Thick Biological Samples and Microchips

High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.

36 MATERIALS SCIENCE↗

Desorption characteristics of selenium and tellurium thin films

The temperature-dependent desorption behavior of selenium and tellurium is investigated using a heated quartz crystal microbalance. Prior to heating the quartz crystal microbalance, selenium and tellurium films with varying thickness were deposited using thermal effusion cells in a molecular beam epitaxy system for subsequent determination of temperature-dependent mass loss of the deposited films. The desorption rate for tellurium was found to exhibit one sharp peak around 190°C, indicating the loss of the entire film irrespective of film thickness within a temperature window of 20°C, which was completely evaporated at 200°C. Similar experiments for selenium revealed that the thermal desorption took place via a two-stage process with a smaller portion of the material desorbing within an even narrower temperature window of 5°C at a much lower peak temperature of 65°C, while most selenium desorbed within a temperature range of 10°C around 90°C. This two-stage behavior indicated the presence of at least two chemically distinct selenium species or binding states. The direct and quantitative determination of the chalcogen desorption process provides important insights into the kinetics of chalcogenide-based film growth and is in addition of applied benefit to the research community in the area of Se/Te capping and decapping of air sensitive materials as it provides temperature ranges and rates at which full desorption is achieved. Our work furthermore points toward the need for a more detailed understanding of the chemical composition state of atomic and molecular beams supplied from thermal evaporation sources during growth.

36 MATERIALS SCIENCE↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Formation of Mn-rich interfacial phases in Co 2 Fe x Mn 1-x Si thin films

Here, we report the formation of Mn-rich regions at the interface of Co 2 Fe x Mn 1-x Si thin films grown on GaAs substrates by molecular beam epitaxy (MBE). Scanning transmission electron microscopy (STEM) with electron energy loss (EEL) spectrum imaging reveals that each interfacial region: (1) is 1–2 nm wide, (2) occurs irrespective of the Fe/Mn composition ratio and in both Co-rich and Co-poor films, and (3) displaces both Co and Fe indiscriminately. We also observe a Mn-depleted region in each film directly above each Mn-rich interfacial layer, roughly 3 nm in width in the x = 0 and x = 0.3 films, and 1 nm in the x = 0.7 (less Mn) film. We posit that growth energetics favor Mn diffusion to the interface even when there is no significant Ga interdiffusion into the epitaxial film. Element-specific X-ray magnetic circular dichroism (XMCD) measurements show larger Co, Fe, and Mn orbital to spin magnetic moment ratios compared to bulk values across the Co 2 Fe x Mn 1-x Si compositional range. The values lie between reported values for pure bulk and nanostructured Co, Fe, and Mn materials, corroborating the non-uniform, layered nature of the material on the nanoscale. Finally, SQUID magnetometry demonstrates that the films deviate from the Slater-Pauling rule for uniform films of both the expected and the measured composition. The results inform a need for care and increased scrutiny when forming Mn-based magnetic thin films on III-V semiconductors like GaAs, particularly when films are on the order of 5 nm or when interface composition is critical to spin transport or other device applications.

36 MATERIALS SCIENCE↗

Sequential Bond Dissociation Energies of Th + (CO) x , x = 3–6: Guided Ion Beam Collision-Induced Dissociation and Quantum Computational Studies

Collision-induced dissociation (CID) of [Th,xC,xO] + , x = 3–6, with Xe is performed using a guided ion beam tandem mass spectrometer (GIBMS). Products are formed exclusively by the loss of CO ligands. Analyses of the kinetic energy-dependent CID product cross sections yield bond dissociation energies (BDEs) of (CO) x–1 Th + –CO at 0 K as 1.09 ± 0.05, 0.82 ± 0.07, 0.63 ± 0.05, and 0.70 ± 0.05 eV, respectively. Different structures of [Th,xC,xO] + were explored using various electronic structure methods, and BDEs for CO ligand loss from precursor [Th,xC,xO] + complexes were computed. Both experimental and theoretical results corroborate that the structures of [Th,xC,xO] + , x = 3–6, formed experimentally are homoleptic thorium cation carbonyl complexes, Th + (CO) x . The nonmonotonic trend in experimental BDEs is reproduced theoretically, although ambiguities in the spin states of the x = 4–6 complexes (doublet or quartet) remain. BDEs calculated at the coupled cluster with single, double, and perturbative triple excitations (CCSD(T))/cc-pVXZ//B3LYP/cc-PVXZ (X = T and Q) level and a complete basis set (CBS) extrapolation agree reasonably well with the experimental values for all complexes. Thorium oxide ketenylidene carbonyl cations, OTh + CCO(CO) y , y = 1–4, were calculated to be the most stable structures of [Th,xC,xO] + , x = 3–6, respectively; however, these are not observed in our experiment. Potential energy profiles (PEPs) having either quartet or doublet spin calculated at the B3LYP/cc-pVQZ level suggest that the failure to observe OTh + CCO(CO) y , y = 1–4, is the result of a barrier corresponding to the C–C bond formation, making the formation of OTh + CCO(CO) y inaccessible kinetically under the present experimental conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing electronic structure in berkelium and californium via an electron microscopy nanosampling approach

Due to their rarity and radioactive nature, comparatively little is known about the actinides, particularly those with atomic numbers higher than that of plutonium, and their compounds. In this work, we describe how transmission electron microscopy can provide comprehensive, safe, and cost-effective characterization using only single nanogram amounts of highly-radioactive, solid compounds. Chlorides of the rare elements berkelium and californium are dropcast and then converted in situ to oxides using the electron beam. The f-band occupancies are probed using electron energy loss spectroscopy and an unexpectedly weak spin-orbit-coupling is identified for berkelium. In contrast, californium follows a jj coupling scheme. These results have important implications for the chemistries of these elements and solidify the status of californium as a transitional element in the actinide series.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative phase imaging by gradient retardance optical microscopy

Abstract Quantitative phase imaging (QPI) has become a vital tool in bioimaging, offering precise measurements of wavefront distortion and, thus, of key cellular metabolism metrics, such as dry mass and density. However, only a few QPI applications have been demonstrated in optically thick specimens, where scattering increases background and reduces contrast. Building upon the concept of structured illumination interferometry, we introduce Gradient Retardance Optical Microscopy (GROM) for QPI of both thin and thick samples. GROM transforms any standard Differential Interference Contrast (DIC) microscope into a QPI platform by incorporating a liquid crystal retarder into the illumination path, enabling independent phase-shifting of the DIC microscope's sheared beams. GROM greatly simplifies related configurations, reduces costs, and eradicates energy losses in parallel imaging modalities, such as fluorescence. We successfully tested GROM on a diverse range of specimens, from microbes and red blood cells to optically thick (~ 300 μm) plant roots without fixation or clearing.

47 OTHER INSTRUMENTATION↗

Detectors and beam monitors based on wide bandgap semiconductors at cryogenic temperatures

Wide-bandgap semiconductors, such as single-crystal diamond and sapphire, can be used to measure the flux of passing particles through a particle-induced conductivity effect. We recently demonstrated a diamond-based, electrodeless electron beam halo monitor. This monitor utilized a thin diamond blade placed within an open, high-quality microwave resonator. The blade partially intercepted the beam and changes in the RF properties of the resonator were used to infer beam parameters. To enhance the sensitivity of our semiconductor sensors, we propose two new techniques: (1) biasing the semiconductor sensor to support avalanche multiplication of free carriers, and (2) operating at cryogenic temperatures to reduce intrinsic semiconductor losses and increase the mobility of induced carriers. These techniques are applicable not only to particle beam diagnostics but also to the detection of various types of ionizing radiation.

Accelerator Physics↗

Conceptual Design of a Scintillator-Based Fast-Ion Loss Detector for the Wendelstein 7-X Stellarator

Here, a conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co-and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity–space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion Beam Propagation Through the FNAL LEBT

The Fermilab 750keV injector sends 25mA H- beam for 30µs at a rep-rate of 15Hz. The beam transmission through the FNAL injector is currently less than 50% from the ion source to the entrance of the drift tube linac. Recently it was uncovered that the primary loss point is within the region prior to the RFQ which houses the solenoid focal elements that match the beam to the RFQ. Recent diagnostic measurements indicate that the cause of the transmission efficiency could be the non-linear effects of the solenoid elements on the beam. An aperture restriction was placed just upstream of the first solenoid element to restrict the beam size and reduce the non-linear effects of the solenoid element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic Aperture of the PIP-II Accumulator Ring (PAR)

The Proton Improvement Plan-II (PIP-II) will include a superconducting linear accelerator which will accelerate H- ions to 800MeV, at an intensity never seen before. A proposed PIP-II Accumulator Ring (PAR) can reduce the injection losses to the booster, enhance the ramp up of the Long Baseline Neutrino Facility (LBNF) and support experiments in Dark Sector Physics. When the beam is circulating in PAR at its full intensity, it will then be transferred to the Booster via single turn injection. Strong PAR focusing results in larger phase advances, shorter focal lengths and higher machine tunes, which creates robust beam envelope control. Particles will be able to survive modest excursions from the elliptical phase-space trajectories of linear optics, and any loss of particles would be due to reduced dynamic aperture. The values for tunes and chromaticities are flexible and will continue to evolve as the lattice matures. Since there will be non-linear terms impacting the particles’ trajectories, tracking will include realistic magnetic field errors and installation alignment errors to determine the dynamic aperture as a function of the machine tunes. This will allow us to determine the optimum operating point in phase-space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-throughput injection-acceleration of electron bunches from a linear accelerator to a laser wakefield accelerator

Plasma-based accelerators (PBAs) driven by either intense lasers (laser wakefield accelerators, LWFAs) or particle beams (plasma wakefield accelerators, PWFAs), can accelerate charged particles at extremely high gradients compared to conventional radio-frequency (RF) accelerators. In the past two decades, great strides have been made in this field, making PBA a candidate for next-generation light sources and colliders. However, these challenging applications necessarily require beams with good stability, high quality, controllable polarization and excellent reproducibility. To date, such beams are generated only by conventional RF accelerators. As such, it is important to demonstrate the injection and acceleration of beams first produced using a conventional RF accelerator, by a PBA. In some recent studies on LWFA staging and external injection-acceleration in PWFA only a very small fraction (from below 0.1% to few percent) of the injected charge (the coupling efficiency) was accelerated. For future colliders where beam energy will need to be boosted using multiple stages, the coupling efficiency per stage must approach 100%. Here we report the first demonstration of external injection from a photocathode-RF-gun-based conventional linear accelerator (LINAC) into a LWFA and subsequent acceleration without any significant loss of charge or degradation of quality, which is achieved by properly shaping and matching the beam into the plasma structure. Furthermore, this is an important step towards realizing a high-throughput, multi-stage, high-energy, hybrid conventional-plasma accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A combined theoretical and experimental study of small anthracene–water clusters

Water-cluster interactions with polycyclic aromatic hydrocarbons (PAHs) are of paramount interest in many chemical and biological processes. Here we report a study of anthracene monomers and dimers with water (up to four)-cluster systems utilizing molecular beam vacuum-UV photoionization mass spectrometry and density functional calculations. Structural loss in photoionization efficiency curves when adding water indicates that various isomers are generated, while theory indicates only a slight shift in energy in photoionization states of different isomers. Calculations reveal that the energetic tendency of water is to remain clustered and not to disperse around the PAH. Theoretically, we observe water confinement exclusively in the case of four water clusters and only when the anthracenes are in a cross configuration due to optimal OH∙∙∙π interactions, indicating dependence on the size and structure of the PAH. Furthermore theory sheds light on the structural changes that occur in water upon ionization of anthracene, due to the optimal interactions of the resulting hole and water hydrogen atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial calibration and synthetic diagnostic of a multi-energy hard x-ray camera at WEST tokamak

WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam–target emission of tungsten at the target due to fast electron losses interacting with the divertor plates. The diagnostic is a pinhole camera based on a 2D pixel array detector (Pilatus 3 CdTe CMOS Hybrid-Pixel detector produced by DECTRIS). The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space and energy-resolved x-ray measurements. This contribution details two important steps in the preparation of the diagnostic operation. First, the in-vessel spatial calibration that was carried out with a radioactive source. Second, the synthetic diagnostic is obtained by the suite of codes ALOHA/C3PO/LUKE/R5-X2, which simulates LH wave propagation and absorption, as well as the fast electron bremsstrahlung production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding Interfacial Electrochemical Reactions through in situ ec-STEM and IL-Cryo-STEM

A major criterion in the design of next generation materials for electrical energy storage applications is a comprehensive understanding of interfacial electrochemical reactions as well as correlating the structure and chemistry across site-specific electrode/electrolyte interfaces with electron, charge, and mass transport processes as they govern performance characteristics. Scanning transmission electron microscopy (STEM) based techniques have emerged as an indispensable materials characterization tool that provides high spatial resolution imaging and chemical analysis and has been effectively utilized to obtain an atomic to nanoscale view of the interfacial structure before and after electrochemical cycling. More recently, there have been several advances that now allows us to obtain more detailed mechanistic insight into evolving reactions through in situ ec-STEM and electrical biasing platforms such as in the understanding of the mechanisms of solid electrolyte interphase formation, lithium dendrite nucleation and growth mechanisms and ionic transport mechanisms within intercalation, conversion, and alloying electrode materials. Several major advantages of the in situ ec-STEM approach is the quantitative electrochemical measurement of charge passed during cycling with simultaneous analysis of the electrochemical processes with STEM imaging and diffraction. Here, while spectroscopic analysis of the electrochemical reactions products has been performed, there is the issue of beam sensitivity and therefore, Cryo-STEM imaging combined with electron energy loss spectroscopy (EELS) techniques have been employed to analyze the chemistry of the SEI and Li dendrites. In this talk, we discuss the potential for combining identical location (IL) STEM techniques with Cryo-EM. The advantage of using this approach is that the sample is placed on a conventional TEM grid and the exact same location of the specimen can be analyzed before and after quantitative electrochemical measurements. Moreover, since the sample is on the TEM grid, the grid itself can be prepared for further Cryo-TEM experiments by plunge freezing in liquid nitrogen then transferred to the Cryo-TEM under liquid nitrogen. Results obtain from these experiments can be used to enhance our scientific understanding of interfacial chemistry at electrode/electrolyte interfaces and may be useful in the design of new materials.

36 MATERIALS SCIENCE↗

ERLs and Sustainability

In any new accelerator proposal, sustainability issues will be heavily scrutinized, be that in electricity and water use, the overall efficiency of the facility, including reusing the heat for other purposes (space heating, biogas production, etc.) or energy recycling. These aspects are important for all new facilities, but ERLs bring a new dimension. Directly returning the energy of an unused beam into RF that can be used for acceleration with practically no losses is a unique feature of ERLs. While not all of the energy can be recovered, the overall efficiency of the process is extremely high. This advantage starts with a reduction in the RF power needed for acceleration, which translates into smaller RF sources and their associated power transformers (reducing the resources needed for their production), and less electric power and water cooling required (reduced operating costs as well as a reduced carbon footprint). Given the inherent advantages of ERLs, it is to be expected that their sustainability profile will eclipse other colliders with similar physics potential.

Hutton, Andrew↗