Electrooptic modulation methods for high sensitivity tunable diode laser spectroscopy

A CdTe phase modulator and low power RF sources have been used with Pb-salt tunable diode lasers operating near 8 microns to generate optical sidebands for high sensitivity absorption spectroscopy. Sweep averaged, first-derivative sample spectra of CH4 were acquired by wideband phase sensitive detection of the electrooptically (EO) generated carrier-sideband beat signal. EO generated beat signals were also used to frequency lock the TDL to spectral lines. This eliminates low frequency diode jitter, and avoids the excess laser linewidth broadening that accompanies TDL current modulation frequency locking methods.

Glenar, David A.↗

Continuous-Wave Single-Frequency Operation of Fabry-Perot Laser Diodes by Self-Injection Phase Locking Using Feedback from a Fiber Bragg Grating

Single-frequency operation of uncoated Fabry-Perot laser diodes is demonstrated by phase- locking the laser oscillations through self-injection seeding with feedback from a fiber Bragg grating. By precisely tuning the laser temperature so that an axial-mode coincides with the short-wavelength band edge of the grating, the phase of the feedback is made conjugate to that of the axial mode, locking the phase of the laser oscillations to that mode.

Duerksen, Gary L.↗

High sensitivity detection of trace gases at atmospheric pressure using tunable diode lasers

A detailed study of the detection of trace gases at atmospheric pressure using tunable diode lasers is described. The influence of multipass cells, retroreflectors and topographical targets is examined. The minimum detectable infrared absorption ranges from 0.1 percent for a pathlength of 1.2 km to 0.01 percent over short pathlengths. The factors which limit this sensitivity are discussed, and the techniques are illustrated by monitoring atmospehric CO2 and CH4.

Reid, J.↗

High-power diode lasers for optical communications applications

High-power, single-mode, double-heterojunction AlGaAs diode lasers are being developed to meet source requirements for both fiber optic local area network and free space communications systems. An individual device, based on the channeled-substrate-planar (CSP) structure, has yielded single spatial and longitudinal mode outputs of up to 90 mW CW, and has maintained a single spatial mode to 150 mW CW. Phase-locked arrays of closely spaced index-guided lasers have been designed and fabricated with the aim of multiplying the outputs of the individual devices to even higher power levels in a stable, single-lobe, anastigmatic beam. The optical modes of the lasers in such arrays can couple together in such a way that they appear to be emanating from a single source, and can therefore be efficiently coupled into optical communications systems. This paper will review the state of high-power laser technology and discuss the communication system implications of these devices.

Carlin, D. B.↗

Stable isotope analysis using tunable diode laser spectroscopy

Ratios of C-12/C-13 in CO2 have been measured using a tunable diode laser (TDL) spectrometer to an accuracy of better than 0.4 percent. These results were made possible by the use of state-of-the-art high-temperature TDLs, an etalon and wavenumber calibration technique, high-speed assembly language controlled data acquisition, and the ratioing of absorbances from simultaneously acquired sample and reference data scans. The dual beam spectrometer that is employed uses the sweep integration technique in a spectral region where adjacent spectral lines are of approximately equal absorbance at the expected isotopic abundances.

Becker, Joseph F.↗

Measurements of Trace Gases Using a Tunable Diode Laser

This report is the final report for "Measurements of Trace Gases Using a Tunable Diode Laser." The tasks outlined in the proposal are listed below with a brief comment. The publications and the conference presentations are listed. Finally, the important publications are attached. The Cooperative Agreement made possible a research effort to produce high- precision and high-accuracy in-situ measurements of carbon monoxide, methane and nitrous oxide on the WB-57 during the CRYSTAL-FACE and pre-AVE field campaigns and to analyze these measurements. These measurements of CO and CH4 were of utmost importance to studies of the radiative effects of clouds. Some important results of the CRYSTAL-FACE program were contained in two scientific papers (attached). This Cooperative Agreement allowed the participation of the Argus instrument in the program and the analysis of the data.

Jost, Hans-Juerg↗

Characteristics of the Single-Longitudinal-Mode Planar-Waveguide External Cavity Diode Laser at 1064 nm

We describe the characteristics of the planar-waveguide external cavity diode laser (PW-ECL). To the best of our knowledge, it is the first butterfly-packaged 1064 nm semiconductor laser that is stable enough to be locked to an external frequency reference. We evaluated its performance from the viewpoint of precision experiments. Using a hyperfine absorption line of iodine, we suppressed its frequency noise by a factor of up to 104 at 10 mHz. The PWECL's compactness and low cost make it a candidate to replace traditional Nd:YAG nonplanar ring oscillators and fiber lasers in applications that require a single longitudinal mode.

planar-waveguide↗

Diagnostics and control of wavenumber stability and purity of tunable diode lasers relevant to their use as local oscillators in heterodyne systems

Initial operation of the tunable diode lasers (TDL) showed that it was not possible to adjust the wavenumber to one selected a priori in the TDL tuning range. During operation, the operating point would change by 0.1/cm over the longer term with even larger changes occurring during some thermal cycles. Most changes during thermal cycling required using lower temperatures and higher currents to reach the former wavenumber (when it could be reached). In many cases, an operating point could be selected by changing TDL current and temperature to give both the desired wavenumber and most of the power in a single mode. The selection procedure had to be used after each thermal cycling. Wavenumber nonlinearities of about 10% over a 0.5 cm tuning range were observed. Diagnostics of the single mode selected by a grating monochromator showed wavenumber fine structure under certain operating conditions. The characteristics due to the TDL environment included short term wavenumber stability, the instrument lineshape function, and intermediate term wavenumber stability.

Poultney, S.↗

Correlation-based technique for automated tunable diode laser scan stabilization

A software-based method for real-time, active stabilization of tunable diode laser spectral scans is described. The procedure is suitable for use with field and laboratory instrumentation where automated, unattended spectrometer operation is required. An autocorrelation of two high-resolution reference gas infrared spectra is computed at regular intervals, and the location of the maximum value of the autocorrelation provides the relative abscissa shift between the spectra. Small adjustments to the laser scan parameters are thereby made to ensure that drifts in the laser output frequency are tracked and compensated. Calculations required for stabilization of a 512-point spectrum can be completed in under 25 ms using an inexpensive, moderate-speed, array processor installed in a PC.

May, Randy D.↗

Laser diode ignition characteristics of Zirconium Potassium Perchlorate (ZPP)

Hi-Shear Technology, Corp., (HSTC) has designed and built a Laser equivalent NASA Standard Initiator (LNSI). Langlie tests with a laser diode output initiating ZPP were conducted as a part of this effort. The test parameters include time to first pressure, laser power density requirements, and ignition time. The data from these laser tests on ZPP are presented.

Callaghan, Jerry D.↗

Heterodyne spectroscopy of astronomical and laboratory sources at 8.5 microns using diode laser local oscillators

The first 8.5 microns infrared heterodyne spectrometer has been constructed using tuneable semiconductor (PbSe) diode lasers and was used to measure absorption line profiles of N2O in the laboratory, as well as black-body emission from the moon and from Mars. Spectral information was recorded over a 200 MHz bandwidth using an 8-channel filter bank. The resolution was 25 MHz (6 millionths of a micron), and the minimum detectable (black-body) power was approximately 1 times 10 to the minus 16th power W for 8 min of integration. The results demonstrate the usefulness of heterodyne spectroscopy for the study of remote and local sources in the infrared.

Mumma, M.↗

Optically coupling tunable diode lasers

Proposed opticle coupling, using lenses and mirrors that replace complex mechanical systems, can combine separate tunable diode laser outputs and expand wavelength range. Method uses single cooler housing and requires no moving parts within cooler assembly.

Robinson, D. M.↗

Laboratory simulation of tunable diode laser remote measurement of atmospheric gases using topographic targets

In order to test the possibility that tunable diode laser (TDL) systems using topographic targets can be applied to the measurement of a variety of gases at concentrations and distances characteristic of industrial gas leaks, a single-ended TDL system was assembled for use with selected topographic targets to detect NO2 at atmospheric pressure and NO2 and NH3 at low pressures. In both cases, the intensity distribution of radiation backscattered from selected targets was found to be heavily weighted to a specular rather than a Lambertian distribution. A sensitivity of 5 ppm-m has been demonstrated for the case of NO2.

Webster, C. R.↗

Diode laser measurements of the band strengths of nu(3) and nu(6) in (C-12)H3D

A diode laser spectrometer has been used to measure line strengths for 143 transitions in the nu(6) fundamental band of (C-12)H3D near 9 microns. These line-strength measurements have been used to derive a band strength for nu(6) and nu(3). The band strength derived for nu(6) is 61.7 + or - 1.8/sq cm/atm and that for nu(3) is 49.3 + or - 1.4/sq cm/atm at 295 K.

Boyle, R. J.↗

Fiber-optic interferometer using frequency-modulated laser diodes

This paper describes an electrically passive fiber-optic interferometer which uses dual frequency-modulated laser diodes. Experimental results show that this type of interferometer can attain a displacement range of 100 micron with subnanometer resolution. This technique can serve as the basis for a number of high-precision fiber-optic sensors.

Beheim, G.↗

Tunable diode laser spectral diagnostic studies of a pressure modulator radiometer

The successful application of high-resolution tunable diode laser spectroscopy to the diagnostic measurement of a pressure modulator radiometer (PMR) is reported, and recorded line transmission profiles for a single N2O line at 1272/cm are presented. PMR measurements obtained for mean cell pressures of about 10, 20, and 30 Torr were found to be consistent with theoretical predictions. The validity of single-pressure and two-pressure approximation representations of the mean and modulated PMR transmission spectra has been verified.

May, Randy D.↗

Linear laser diode arrays for improvement in optical disk recording for space stations

The design and fabrication of individually addressable laser diode arrays for high performance magneto-optic recording systems are presented. Ten diode arrays with 30 mW cW light output, linear light vs. current characteristics and single longitudinal mode spectrum were fabricated using channel substrate planar (CSP) structures. Preliminary results on the inverse CSP structure, whose fabrication is less critically dependent on device parameters than the CSP, are also presented. The impact of systems parameters and requirements, in particular, the effect of feedback on laser design is assessed, and techniques to reduce feedback or minimize its effect on systems performance, including mode-stabilized structures, are evaluated.

Alphonse, G. A.↗