Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIODE LASERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

New PbSnTe heterojunction laser diode structures with improved performance

Several recent advances in the state-of-the-art of lead tin telluride double heterojunction laser diodes are summarized. Continuous Wave operation to 120 K and pulsed operation to 166 K with single, lowest order transverse mode emission to in excess of four times threshold at 80 K were achieved in buried stripe lasers fabricated by liquid phase epitaxy in the lattice-matched system, lead-tin telluride-lead telluride selenide. At the same time, liquid phase epitaxy was used to produce PbSnTe distributed feedback lasers with much broader continuous single mode tuning ranges than are available from Fabry-Perot lasers. The physics and philosophy behind these advances is as important as the structures and performance of the specific devices embodying the advances, particularly since structures are continually being evolved and the performance continues to be improved.

Fonstad, C. G.↗

Tunable diode laser measurements of line strengths in the nu4 band of C-12H4

Absolute intensities have been measured, using a diode laser spectrometer for several vibration-rotation lines in the nu4 fundamental of methane. The data have been analyzed, with the inclusion of Coriolis interactions, to obtain a transition moment of (0.0508 plus or minus 0.0015) x 10 to the minus 18th esu cm. This work appears to resolve some earlier difficulties in interpreting measurements and calculations of intensities in nu4 of CH4.

Fox, K.↗

long wavelength Pb(1-x)Sn(X)Se and Pb(1-x)Sn(x)Te diode lasers as local oscillators

A breadboard heterodyne receiver is described which was used to establish the characteristics of lead salt diode lasers pertinent to their use as local oscillators using laser devices operating in the 15-25 micrometer spectral region. Heterodyne detection efficiency is directly correlated with the transverse mode structure and emphasizes the necessity of stable lowest order mode operation for lasers when used as local oscillators. The results obtained indicate that the continued development of these lasers provide suitable local oscillators for a variety of applications.

Washwell, E. R.↗

Tunable diode laser measurements of formaldehyde foreign-gas broadening parameters and line strengths in the 9-11-micron region

A tunable diode laser spectrometer has been used to determine pressure broadening coefficients due to collision with the foreign gases air, H2, O2, and N2 in the nu4 and nu6 bands of H2CO between 9 and 11 microns. Absolute line strengths for twenty-eight transitions have also been determined. The broadening coefficients are very similar to theoretical literature values in the cases of air, N2, and O2. The H2-H2CO values are in good agreement with earlier experimental millimeter-wave results.

Nadler, Shachar↗

Tunable diode laser mesurements of widths of air- and nitrogen-broadened lines in the nu(4) band of C-13H4

Tunable diode laser measurements of air-broadened and N2-broadened halfwidths are reported for 23 lines in the nu(4) band of C-13H4, between 1260 and 1360/cm. For all lines, at least three scans of each of four or more pressures were recorded. The experimental halfwidths presently obtained for C-13H4 are both larger and smaller than the U.S. Air Force Geophysics Laboratory values.

Devi, V. M.↗

Diode laser absorption sensors for gas-dynamic and combustion flows

Recent advances in room-temperature, near-IR and visible diode laser sources for tele-communication, high-speed computer networks, and optical data storage applications are enabling a new generation of gas-dynamic and combustion-flow sensors based on laser absorption spectroscopy. In addition to conventional species concentration and density measurements, spectroscopic techniques for temperature, velocity, pressure and mass flux have been demonstrated in laboratory, industrial and technical flows. Combined with fibreoptic distribution networks and ultrasensitive detection strategies, compact and portable sensors are now appearing for a variety of applications. In many cases, the superior spectroscopic quality of the new laser sources compared with earlier cryogenic, mid-IR devices is allowing increased sensitivity of trace species measurements, high-precision spectroscopy of major gas constituents, and stable, autonomous measurement systems. The purpose of this article is to review recent progress in this field and suggest likely directions for future research and development. The various laser-source technologies are briefly reviewed as they relate to sensor applications. Basic theory for laser absorption measurements of gas-dynamic properties is reviewed and special detection strategies for the weak near-IR and visible absorption spectra are described. Typical sensor configurations are described and compared for various application scenarios, ranging from laboratory research to automated field and airborne packages. Recent applications of gas-dynamic sensors for air flows and fluxes of trace atmospheric species are presented. Applications of gas-dynamic and combustion sensors to research and development of high-speed flows aeropropulsion engines, and combustion emissions monitoring are presented in detail, along with emerging flow control systems based on these new sensors. Finally, technology in nonlinear frequency conversion, UV laser materials, room-temperature mid-IR materials and broadly tunable multisection devices is reviewed to suggest new sensor possibilities.

Non-NASA Center↗

Intermode calibration of diode-laser spectra using tandem etalons

The paper deals with an approach which can improve the accuracy of etalon calibration of tunable diode-laser (TDL) spectra in the IR and extend absolute calibration among several isolated modes. Two etalons placed in the laser beam produce a combined fringe pattern that, with the aid of a monochromator mode selector, can be used to establish the number of fringes between any two spectral points separated by a large frequency interval. This technique has been applied to several similar cases for calibration of isolated modes or verification of the identity of lines of known frequency.

Jennings, D. E.↗

Efficient second harmonic generation of a diode-laser-pumped CW Nd:YAG laser using monolithic MgO:LiNbO3 external resonant cavities

56-percent efficient external-cavity-resonant second-harmonic generation of a diode-laser pumped, CW single-axial-mode Nd:YAG laser is reported. A theory of external doubling with a resonant fundamental is presented and compared to experimental results for three monolithic cavities of nonlinear MgO:LiNbO3. The best conversion efficiency was obtained with a 12.5-mm-long monolithic ring cavity doubler, which produced 29.7 mW of CW, single-axial model 532-nm radiation from an input of 52.5 mW.

Kozlovsky, William J.↗

A modified equivalent-width technique for diode-laser line strength measurements

A modified equivalent-width method is introduced that improves the accuracy of spectral line strength measurements using diode lasers. This method differs from the standard method in that no attempt is made to calculate the true equivalent width in order to determine the line strength. Instead, the line strength is derived directly from a measurement of the area under the line close to the line center and ignore the normal correction terms. Tests with actual spectra and simulations indicate that this method is accurate to better than 1 percent with lines broadened by up to 50 percent by the laser instrument function.

Strow, L. Larrabee↗

Range finding using frequency-modulated laser diode

A coherent-optical time-of-flight range-finding technique is proposed which uses a simple inexpensive device. Target range is determined by modulating a laser diode's optical frequency and measuring the change in the phase of the light reflected back into the laser. Target velocity as well as range can be measured using this approach. The device is described, and experimental evidence is presented to show the feasibility of measuring distance with subcentimeter resolution over a 1.5-m range.

Beheim, G.↗

Phase-front measurements of an injection-locked AlGaAs laser-diode array

The phase-front quality of the primary spatial lobe emitted from an injection-locked gain-guided AlGaAs laser-diode array is measured by using an equal-path, phase-shifting Mach-Zehnder interferometer. Root-mean-square phase errors of 0.037 + or - 0.003 wave are measured for the single spatial lobe, which contained 240-mW cw output power in a single longitudinal mode. This phase-front quality corresponds to a Strehl ratio of S = 0.947, which results in a 0.23-dB power loss from the single lobe's ideal diffraction-limited power. These values are comparable with those measured for single-stripe index-guided AlGaAs lasers.

Cornwell, Donald M., Jr.↗

Observation of nuclear quadrupole hyperfine structure in the infrared spectrum of hydrogen iodide using a tunable-diode laser

Nuclear quadrupole hyperfine structure has been observed in the 1-0 vibration-rotation band of hydrogen iodide with a tunable-diode laser. The measured splittings agree well with microwave measurements of the HI molecule. Evidence for a slight change in the iodine nuclear quadrupole coupling constant from the ground to first excited vibrational state in hydrogen iodide was found.

Strow, L. L.↗

Dynamic characteristics of far-field radiation of current modulated phase-locked diode laser arrays

A versatile and powerful streak camera/frame grabber system for studying the evolution of the near and far field radiation patterns of diode lasers was assembled and tested. Software needed to analyze and display the data acquired with the steak camera/frame grabber system was written and the total package used to record and perform preliminary analyses on the behavior of two types of laser, a ten emitter gain guided array and a flared waveguide Y-coupled array. Examples of the information which can be gathered with this system are presented.

Elliott, R. A.↗

Tunable diode laser measurements of line widths in the nu1-fundamental band of (N-14)2(O-16) at atmospheric temperatures

A tunable diode-laser spectrometer and a low-temperature absorption cell have been employed to measure the N2-broadened and O2-broadened half-widths of rotational lines in the nu1 fundamental band of (N-14)2(O-16) at 185, 235, 263, and 295 K. The temperature dependence of the line widths has been observed to be practically identical, thereby leading to the suggestion that air-broadening would exhibit the same dependence.

Varanasi, P.↗

Active frequency stabilization of a 1.062-micron, Nd:GGG, diode-laser-pumped nonplanar ring oscillator to less than 3 Hz of relative linewidth

Results are presented on the frequency stabilization of two diode-laser-pumped ring lasers that are independently locked to the same high-finesse interferometer. The relative frequency stability is measured by locking the lasers one free spectral range apart and observing the heterodyne beat note. The resultant beat note width of 2.9 Hz is consistent with the theoretical system noise-limited linewidth and is approximately 20 times that expected for shot-noise-limited performance.

Day, T.↗

In situ measurement of stratospheric nitric oxide using a balloon-borne tunable diode laser spectrometer

The stratospheric mixing ratio of nitric oxide at an altitude of 36 km has been measured using a balloon-borne tunable diode laser (TDL) instrument operating in the 5.2-micron wavelength region. Currently the instrument operates with two TDLs, and the capability exists to measure four stratospheric species simultaneously: NO, NO2, O3, and H2O. During the NO measurements reported here, the second TDL operating near 6.2 microns was used to monitor water vapor concentration in the vicinity of the gondola by observing the 1889.57 per cm line absorption in the reference channel path length (1 m).

Webster, C. R.↗