Search NASA⌕ Search

SEARCH · Search NASA

Results for “GRIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Tensile testing apparatus

An improved mechanical extensometer is described for use with a constant load creep test machine. The dead weight of the extensometer is counterbalanced by two pairs of weights connected through a pulley system and to rod extension and leading into the furnace where the test sample is undergoing elevated temperature (above 500 F.) tensile testing. Novel gripper surfaces, conical tip and flat surface are provided in each sampling engaging platens to reduce the grip pressure normally required for attachment of the extensometer to the specimen and reduce initial specimen bending normally associated with foil-gage metal testing.

Blackburn, L. B.↗

A balloon-borne imaging gamma-ray telescope

A balloon-borne coded-aperture gamma-ray telescope for galactic and extragalactic astronomy observations is described. The instrument, called Gamma Ray Imaging Payload (GRIP), is designed for measurements in the energy range from 30 keV to 5 MeV with an angular resolution of 0.6 deg over a 20 deg field of view. Distinguishing characteristics of the telescope are a rotating hexagonal coded-aperture mask and a thick NaI scintillation camera. Rotating hexagonal coded-apertures and the development of thick scintillation cameras are discussed.

Althouse, W. E.↗

Effect of hand-arm exercise on venous blood constituents during leg exercise

Contributions by ancillary hand and arm actions to the changes in blood constituents effected by leg exercises on cycle ergometer were assessed. Static or dynamic hand-arm exercises were added to the leg exercise (50 percent VO2 peak)-only control regimens for the subjects (19-27 yr old men) in the two experimental groups. Antecubital venous blood was analyzed at times 0, 15, and 30 min (T0, T15, and T30) for serum Na(+), K(+), osmolality, albumin, total CA(2+), and glucose; blood hemoglobin, hematocrit, and lactic acid; and change in plasma volume. Only glucose and lactate values were affected by additional arm exercise. Glucose decreased 4 percent at T15 and T30 after static exercise, and by 2 percent at T15 (with no change at T30) after dynamic arm exercise. Conversely, lactic acid increased by 20 percent at T30 after static exercise, and by 14 percent by T15 and 6 percent at T30 after dynamic arm exercise. It is concluded that additional arm movements, performed usually when gripping the handle-bar on the cycle ergometer, could introduce significant errors in measured venous concentrations of glucose and lactate in the leg-exercised subjects.

Wong, N.↗

Laser Holder Aids Centering of X-Ray Head

Laser holder used when alining X-ray head makes procedure safer and more reliable. Laser holder assembly attached to X-ray head to enable head to be alined optically before X-ray exposure. When laser in operating position laser beam shines on spot later illuminated with X-rays. New holder grips laser securely, maintains alinement, does not interfere with head placement, and requires only one 110-V power cord.

Bulthuis, D. V.↗

Quick-Connect Heavy-Duty Fastener

Attaching device combines fast connection and disconnection with high strength. T-shaped stud engages groove in receptacle after one-quarter turn. Further turning tightens nut on receptacle. Like quarter-turn attaching devices, connected and disconnected quickly. Like threaded devices, adjusted to desired preload, withstand high loads, and accommodate wide range of grip lengths.

Moore, D. M.↗

Gentle End Effector for Robots

Gripper handles electronic components without damaging them. Driven by dc motor, movable jaw gently clamps electronic component. Grips such electronic components as resistors, capacitors, and transistors without damaging them and holds them during soldering or other processing.

Webb, W. S.↗

Void-Free Lid for Food Packaging

Flexible cover eliminates air pockets in sealed container. Universal food-package lid formed from flexible plastic. Partially folded, lid unfolded by depressing center portion. Height of flat portion of lid above flange thereby reduced. Pressure of food against central oval depression pops it out, forming dome that provides finger grip for mixing contents with water or opening lid. Therefore food stays fresh, allows compact stacking of partially filled containers, and resists crushing. Originally developed for packaging dehydrated food for use in human consumption on Space Shuttle missions. Other uses include home canning and commercial food packaging.

Watson, C. D.↗

Tether pointing platform and space elevator mechanisms analysis of the key concepts for SATP and scaled SATP

The key concepts for a scaled and full model Science and Applications Tethered Platform (SATP) are analysized. This includes a tether pointing platform and a space elevator. The mechanism concepts and technological solutions are given. The idea of the tether pointing platform mechanism is to control and stabilize the attitude of a platform by means of a movable tether. The idea of the space elevator mechanism for a scaled SATP is to drag the tether gripping it between two rotating wheels.

Turci, E.↗

Pilot usage of decoupled flight path and pitch controls

Data from decoupled flight maneuvers have been collected and analyzed for four AFTI-F-16 pilots operating this aircraft's highly augmented fly-by-wire control system, in order to obtain spectral density, cross spectra, and Bode amplitude data, as well as coherences and phase angles for the two longitudinal axis control functions of each of 50 20-sec epochs. The analysis of each epoch yielded five distinct plotted parameters for the left hand twist grip and right hand sidestick controller output time series. These two control devices allow the left hand to generate vertical translation, direct lift, or pitch-pointing commands that are decoupled from those of the right hand. Attention is given to the control patterns obtained for decoupled normal flight, air-to-air gun engagement decoupled maneuvering, and decoupled air-to-surface bombing run maneuvering.

Berkhout, J.↗

The WPI space glove design project

Worcester Polytechnic Institute (WPI) was one of four colleges and universities awarded NASA grants for student design and development of an improved glove for space suits. This paper traces the design, development and testing of the WPI prototype glove. Test results showed that the glove did not significantly limit hand and finger motion when pressurized at 8 psi, except in the spherical grip mode. This project demonstrated that problems originating from space technology provide excellent vehicles for student learning and can generate creative solutions.

Durgin, W. W.↗

Prehensile Foot Restraint

Proposed prehensile foot restraint enables such workers as astronauts and divers to maintain fixed positions in zero gravity or in buoyancy with minimal effort. With foot restraint worker devotes attention fully to task at hand, with little concern about holding on to supporting structure. Claw near toe of shoe grips rail. Wearer uses flexible shaft, first to lock claw tightly on bar; then, when work is done, to open claw. Underwater or in space, device boosts productivity.

Willits, Charles A.↗

Development of a Pre-Prototype Power Assisted Glove End Effector for Extravehicular Activity

The purpose of this program was to develop an EVA power tool which is capable of performing a variety of functions while at the same time increasing the EVA crewmember's effectiveness by reducing hand fatigue associated with gripping tools through a pressurized EMU glove. The Power Assisted Glove End Effector (PAGE) preprototype hardware met or exceeded all of its technical requirements and has incorporated acoustic feedback to allow the EVA crewmember to monitor motor loading and speed. If this tool is to be developed for flight use, several issues need to be addressed. These issues are listed.

Source record↗

Rotary stepping device with memory metal actuator

A rotary stepping device includes a rotatable shaft which is driven by means of a coiled spring clutch which is alternately tightened to grip and rotate the shaft and released to return it to a resting position. An actuator formed of a memory metal is used to pull the spring clutch to tighten it and rotate the shaft. The actuator is activated by heating it above its critical temperature and is returned to an elongated configuration by means of the force of the spring cloth.

Jamieson, Robert S.↗

Design of test specimens and procedures for generating material properties of Douglas fir/epoxy laminated wood composite material: With the generation of baseline data at two environmental conditions

In support of the design of wind turbine generator airfoils/blades utilizing Douglas Fir/West System Epoxy laminated composite material, a program was undertaken to define pertinent material properties utilizing small scale test specimens. Task 1 was the development of suitable monotonic tension, compression, short beam shear and full reversed cyclic specimen designs and the companion grips and testing procedures. Task 2 was the generation of the material properties at two environmental conditions utilizing the specimens and procedures developed in Task 1. The monotonic specimens and procedures generated results which compare favorably with other investigators while the cyclic results appear somewhat conservative. Adding moisture and heat or scarf joints degraded the monotonic performance but had a more nebulus effect with cyclic loading.

Johnson, Paul E.↗

Robot Gripper With Signal Processing

Single-chip computer and sensor-circuit chips preprocess sensor data. Self-contained circuitry combines sensor signals for serial digital transmission. Gripping surfaces crossed with grooves for grasping differently shaped objects. Gripper cavities house sensors and preprocessing circuitry. Sensors and preprocessing circuitry in robot gripper reduce amount of data being transmitted between robot controller and gripper. Placement in gripper reduces signal delays and vulnerability to electromagnetic interference.

Killion, Richard R.↗

Handheld Controller For Robotic End Effector

Controller provides both position and force feedback. Hand grip houses controller. End-effector force and position fed back to operator's hand through rotation of trigger and rocking of trigger guard.

Jau, Bruno M.↗

Tool For Tinning Integrated-Circuit Leads

As many as eight flatpacks held. Tool made of fiberglass boards. Clamps row of flatpacks by their leads so leads on opposite side of packages dipped. After dipping, nuts on boards loosened, flatpacks turned around, nuts retightened, and untinned leads dipped. Strips of magnetic material grip leads of flatpacks (made of Kovar, magnetic iron/nickel/cobalt alloy) while boards repositioned. Micrometerlike screw used to adjust exposed width of magnetic strip to suit dimensions of flatpacks. Holds flatpack integrated circuits so leads tinned. Accommodates several flatpacks for simultaneous dipping of leads in molten solder. Adjusts to accept flatpacks in range of sizes.

Prosser, Gregory N.↗

High temperature tensile testing of ceramic composites

The various components of a high temperature tensile testing system are evaluated. The objective is the high temperature tensile testing of SiC fiber reinforced reaction bonded Si3N4 specimens at test temperatures up to 1650 C (3000 F). Testing is to be conducted in inert gases and air. Gripping fixtures, specimen configurations, furnaces, optical strain measuring systems, and temperature measurement techniques are reviewed. Advantages and disadvantages of the various techniques are also noted.

Gyekenyesi, John Z.↗