Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

'Self-consistent' production of ion conics on return current region auroral field lines - A time-dependent, semi-kinetic model

We describe initial results from a time-dependent, semi-kinetic model of plasma outflow incorporating wave-particle interactions along current-carrying auroral field lines. Electrostatic waves are generated by the current driven ion cyclotron instability (CDICI), causing perpendicular velocity diffusion of ions plus electron heating via anomalous resistivity when and where the relative drift between electrons and ions exceeds certain critical velocities. Using the local bulk parameters we calculate these critical velocities, and so are able to self-consistently switch on and off the heating of the various particle species. Due to the dependence of these critical velocities on the bulk parameters of the species the heating effects exhibit quite complex spatial and temporal variations. A wide range of ion distribution functions are observed in these simulations, including conics with energies of a few electron volts and 'ring' distributions. The rings are seen to be a natural result of transverse heating and velocity filter effects and do not require coherent acceleration processes. We also observe the formation of a density depletion in hydrogen and enhanced oxygen densities at high altitudes.

Brown, David G.↗

Strain-Modulated Exciton Localization and Enhanced Emission in Multilayer GaSe

Strain engineering is one of the most effective routes for tuning the electrical and optical properties of two-dimensional layered materials. Besides reproducing the results of other groups on the tunability and photoluminescence (PL) enhancement of free and bound excitons under mechanical deformation or thermal effects, we systematically studied the mechanical strain (wrinkle) and local thermal strain (laser heating) effects on the PL lifetime and polarization in GaSe multilayers and their interplay, revealing their coupled impact on excitonic dynamics. Here, the PL intensity of localized excitons in the wrinkle region of GaSe increases superlinearly with the excitation laser power. The polarization effect has been observed for the bound exciton in GaSe under mechanical strain, but not in GaSe under thermal strain. Fluorescence lifetime imaging (FLIM) measurements reveal strain-tunable lifetimes for both free and bound excitons, and the lifetime of the bound exciton is longer than the free exciton in the mechanical strain region, correlating with the enhanced emission of the bound exciton. These results highlight previously uncharacterized optoelectronic tunability in GaSe and broaden the design space for strain (or thermally)-controlled 2D layered devices.

, GaSe, Exciton localization↗

Characterization of the Heat Extraction Capability of a Compliant, Sliding, Thermal Interface for Use in a High Temperature, Vacuum Microgravity Furnace

Much of the material science gained in microgravity research requires processing a sample in a high performance furnace. One such furnace currently being designed is the Quench Module Insert (QMI). The Principle Investigators, for whom the furnace is proposed, require high temperature gradients in their cylindrical samples to achieve the science objectives. One of the components critical to achieving high sample axial temperature gradients in the Quench Module Insert is a high performance cold zone to extract the heat from the sample. This cold zone employs a compliant, sliding thermal interface based on a Vel-Therm felt. This felt provides a conductive path between the Sample Cartridge Assembly (SCA) exterior surface and the interior surface of the water cooled chill block while allowing movement of the sample relative to the chill block. The Vel-Therm felt is composed of long polymer-based fibers affixed to a thin flexible substrate layer. The fibers are oriented perpendicular to this substrate giving the felt the appearance of a velvet fabric. The Vel-Therm felt heat extraction capability was quantified in earlier tests performed in an inert gas environment. The current activity, described in this paper, is intended to characterize the extraction capability of Vel-Therm felt in a vacuum environment similar to the QMI environment. This testing is necessary to quantify the thermal performance of the Vel-Therm felt and the sensitivity of that performance to key variables. The data derived from these tests will be incorporated into the current thermal models to improve the quality of the models and reduce uncertainty of the analytical results. In addition, the data will be used to help select the appropriate Vel-Therm felt and set proper operating limits as well as assess the performance range of the furnace. The objective of this test is to measure the heat extraction rate of the Vel-Therm felt as specified by the effective heat transfer coefficient. Therefore, the test setup was designed to force the bulk of the heat transfer through the area where the Vel-Therm felt was applied. A heat source, consisting of a ceramic heating element encased in a Copper (Cu) housing is mounted on four isolated support rods. A 6-layer molybdenum radiation shield is used to insulate against heat loss from the heater and prevent heat exchange between the hot and cold sides of the test apparatus. The Vel-Therm felt is affixed to the surface of the cold sink, a water-cooled Cu chill block. An adjustable plate supports and isolates the cold sink from above and is used to control the amount of the deflection of the Vel- Therm when in contact with the Cu heating element housing. The primary means of establishing the power being conducted through the felt is to measure the energy being transferred to the water passing through the chill block. Analysis was performed to support the assumption that the source and sink surfaces were approximately isothermal under the specific test conditions. As a check on the amount of power passing through the felt, the power supplied to the heater was also measured. Thermocouples were strategically located throughout the test apparatus for measurement purposes. A bell jar was lowered over the assembly to impose vacuum conditions. Currently, variables tested have been fiber compression and fiber type and surface temperatures (both the hot and cold side temperatures are hypothesized to be important to the performance of the Vel-Therm.) Selected runs were repeated to ensure consistency and repeatability. Results obtained thus far reveal that Vel-Therm performance is significantly degraded by fibers being exposed to high compression. It also shows that performance is somewhat negatively impacted by previous compression, thereby, raising the question of repeatability. In addition, early results show a significant dependence on temperature. A computer aided mathematical analysis of the test setup is ongoing. The results will be correlated to actual results. The correlation will examine such details as parasitic loses, conduction down the power leads and many other concerns.

Bellomy-Ezell, Jenny↗

Environmental Exposure Effects on Composite Materials for Commercial Aircraft

The test program concentrates on three major areas: flight exposure; ground based exposure; and accelerated environmental effects and data correlation. Among the parameters investigated were: geographic location, flight profiles, solar heating effects, ultraviolet degradation, retrieval times, and test temperatures. Data from the tests can be used to effectively plan the cost of production and viable alternatives in materials selection.

Hoffman, D. J.↗

Review and analysis of high temperature chemical reactions and the effect of non-equilibrium conditions

Chemical reactions at high temperatures have been considered extensively because of their importance to the heating effects on re-entry of space vehicles. Data on these reactions however, are not abundant and even when found there are discrepancies in data collected by various investigators. In particular, data for recombination reactions are calculated from the dissociation reactions or vice versa through the equilibrium constant. This involves the use of the principle of detailed balancing. This principle is discussed in reference to conditions where it is valid as well as to those where it is not valid. Related topics that merit further study or for which applicable information was available are briefly mentioned in an appendix to this report.

Johnson, R. E.↗

Ablative liner locates hotspots

Ablative liner quantifies local-heating effects in combustion chambers and other applications. By identifying hotspots and helping to map heat-flux patterns, liner is useful tool for research in engine design. Liner permanently records heat flux at each point by depth of ablation due to local heating. Technique determines best locations for thermocouples for more extensive testing.

Mercer, S. D.↗

Glass shell manufacturing in space

Highly-uniform, hollow glass spheres (shells), which are used for inertial confinement fusion targets, were formed from metal-organic gel powder feedstock in a vertical furnace. As a result of the rapid pyrolysis caused by the furnace, the gel is transformed to a shell in five distinct stages: (a) surface closure of the porous gel; (b) generation of a closed-cell foam structure in the gel; (c) spheridization of the gel and further expansion of the foam; (d) coalescence of the closed-cell foam to a single-void shell; and (e) fining of the glass shell. The heat transfer from the furnace to the falling gel particle was modeled to determine the effective heating rate of the gel. The model predicts the temperature history for a particle as a function of mass, dimensions, specific heat, and absorptance as well as furnace temperature profile and thermal conductivity of the furnace gas. A model was developed that predicts the gravity-induced degradation of shell concentricity in falling molten shells as a function of shell characteristics and time.

Downs, R. L.↗

Transpiring Cooling of a Scram-Jet Engine Combustion Chamber

The peak cold-wall heating rate generated in a combustion chamber of a scram-jet engine can exceed 2000 Btu/sq ft sec (approx. 2344 W/sq cm). Therefore, a very effective heat dissipation mechanism is required to sustain such a high heating load. This research focused on the transpiration cooling mechanism that appears to be a promising approach to remove a large amount of heat from the engine wall. The transpiration cooling mechanism has two aspects. First, initial computations suggest that there is a reduction, as much as 75%, in the heat flux incident on the combustion chamber wall due to the transpirant modifying the combustor boundary layer. Secondly, the heat reaching the combustor wall is removed from the structure in a very effective manner by the transpirant. It is the second of these two mechanisms that is investigated experimentally in the subject paper. A transpiration cooling experiment using a radiant heating method, that provided a heat flux as high as 200 Btu/sq ft sec ( approx. 234 W/sq cm) on the surface of a specimen, was performed. The experiment utilized an arc-lamp facility (60-kW radiant power output) to provide a uniform heat flux to a test specimen. For safety reasons, helium gas was used as the transpirant in the experiments. The specimens were 1.9-cm diameter sintered, powdered-stainless-steel tubes of various porosities and a 2.54cm square tube with perforated multi-layered walls. A 15-cm portion of each specimen was heated. The cooling effectivenes and efficiencies by transpiration for each specimen were obtained using the experimental results. During the testing, various test specimens displayed a choking phenomenon in which the transpirant flow was limited as the heat flux was increased. The paper includes a preliminary analysis of the transpiration cooling mechanism and a scaling conversion study that translates the results from helium tests into the case when a hydrogen medium is used.

Choi, Sang H.↗

The effect of thermal stresses on the integrity of three built-up aircraft structures

A Mach 6 flight was simulated in order to examine heating effects on three frame/skin specimens. The specimens included: a titanium truss frame with a lockalloy skin; a stainless steel z-frame with a lockalloy skin; and a titanium z-frame with a lockalloy skin. Thermal stresses and temperature were measured on these specimens for the purpose of examining their efficiency, performance, and integrity. Measured thermal stresses were examined with respect to material yield strengths, buckling criteria, structural weight, and geometric locations. Principal thermal stresses were studied from the standpoint of uniaxial stress assumptions. Measured thermal stresses were compared to predicted values.

Jenkins, J. M.↗

Brightness curve and porosity of cometary nuclei

The brightness curve of a comet is analyzed in terms of porosity and nature of volatiles in its nucleus. Mobility of pores, densification, phase changes, differential thermal expansion and heat flow into and out of the nucleus are discussed leading to a method for estimating the effective heat conductivity and porosity of the nucleus. The method is applied to comets P/Giacobini-Zinner, P/Halley, P/Kopff, P/Encke, P/Tempel 2 and P/d'Arrest.

Smoluchowski, R.↗

High Temperature Microwave Dielectric Properties of JSC-1AC Lunar Simulant

Microwave heating has many potential lunar applications including sintering regolith for lunar surface stabilization and heating regolith for various oxygen production reactors. The microwave properties of lunar simulants must be understood so this technology can be applied to lunar operations. Dielectric properties at microwave frequencies for a common lunar simulant, JSC-1AC, were measured up to 1100 C, which is approximately the melting point. The experimentally determined dielectric properties included real and imaginary permittivity (epsilon', epsilon"), loss tangent (tan delta), and half-power depth, the di stance at which a material absorbs 50% of incident microwave energy. Measurements at 2.45 GHz revealed tan delta of JSC-1A increases from 0.02 at 25 C to 0.31 at 110 C. The corresponding half-power depth decreases from a peak of 286 mm at 110 C, to 13 mm at 1100 C. These data indicate that JSC-1AC becomes more absorbing, and thus a better microwave heater as temperature increases. A half-power depth maximum at 100-200 C presents a barrier to direct microwave heating at low temperatures. Microwave heating experiments confirm the sluggish heating effect of weak absorption below 200 C, and increasingly strong absorption above 200 C, leading to rapid heating and melting of JSC-1AC.

Allan, Shawn M.↗

Technical Considerations on MURR Control Blade Design Change and Testing using a New Metal Matrix Composite

The University of Missouri Research Reactor (MURR) is one of six research reactors, including a critical facility, that are pursuing conversion as part of a collaboration with the U.S. Department of Energy National Nuclear Security Administration Material Management and Minimization Office of Reactor Conversion and Uranium Supply, under the U.S. High Performance Research Reactors (USHPRR) conversion project. Five of the six USHPRR are planned to convert from highly enriched uranium (HEU) fuel using a low-enriched uranium (LEU) high assay monolithic alloy of uranium-10 wt% molybdenum (U-10Mo). As part of the conversion safety analysis, it is necessary to demonstrate the safety performance of the proposed core fueled with LEU as compared to the current HEU cores. The MURR reactor is planning to switch to a new control blade design that uses a metal matrix composite of boron carbide (B 4 C) and aluminum as the absorber in place of Boral®. Since MURR is expected to adopt the new metal matrix composite control blade design prior to conversion, the impact of the new blade design on the neutronics characteristics of the MURR cores for conversion are analyzed in this work through updates to incorporate the changes to the blade design in conversion models as they directly impact the LEU conversion safety analysis. The quantitative comparison shows that the neutronics and thermal hydraulic behavior of one metal matrix composite blade replacing a Boral blade is comparable for the two example MURR LEU and HEU cores states considered. Geometrical changes in the metal matrix composite blade design, combined with a 4% increase in areal boron density, showed local heating effects up to 20% higher than the Boral design. As expected, the metal matrix composite showed slightly lower heat depositions and absorber region temperatures for the LEU cases compared to HEU. Although this analysis was comparative for a single blade, maximum control blade temperatures for both Boral, metal matrix composite, and HEU/LEU remained below 100 °C, though additional analysis at a core level could differ. A qualitative irradiation behavior assessment concludes that the mechanisms that may drive swelling and blistering in the current Boral design are eased by the adoption of the metal matrix composite design. The work concludes that the two blade designs are essentially equivalent with regards to neutronics, thermal hydraulics, and expected material behavior under irradiation. However, due to the geometrical changes to the blades including redesigned and thinner cladding, new testing and increased surveillance for distortion and swelling are recommended to confirm the performance of the metal matrix composite control blade design. Where testing is completed prior to conversion, the only anticipated impacts on conversion to LEU U-10Mo fuel would be the need for models and safety analysis incorporating the metal matrix composite control blades.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of convection electric field on upwelling and escape of ionospheric O(+)

A Monte Carlo code is used to explore the full effects of the convection electric field on distributions of upflowing O(+) ions from the cusp/cleft ionosphere. Trajectories of individual ions/neutrals are computed as they undergo multiple charge-exchange collisions. In the ion state, the trajectories are computed in realistic models of the magnetic field and the convection, corotation, and ambipolar electric fields. The effects of ion-ion collisions are included, and the trajectories are computed with and without simultaneous stochastic heating perpendicular to the magnetic field by a realistic model of broadband, low frequency waves. In the neutral state, ballistic trajectories in the gravitational field are computed. The initial conditions of the ions, in addition to ambipolar electric field and the number densities and temperatures of O(+), H(+), and electrons as a function of height in the cusp/cleft region were obtained from the results of Gombosi and Killeen (1987), who used a hydrodynamic code to simulate the time-dependent frictional-heating effects in a magnetic tube during its motion though the convection throat. The distribution of the ion fluxes as a function of height are constructed from the case histories.

Cladis, J. B.↗

Augmented orbiter heat rejection study

Spacecraft radiator concepts are presented that relieve attitude restrictions required by the shuttle orbiter space radiator for baseline and extended capability STS missions. Cost effective heat rejection kits are considered which add additional capability in the form of attached spacelab radiators or a deployable radiator module.

Hixon, C. W.↗

Global projections of heat exposure of older adults

The global population is aging at the same time as heat exposures are increasing due to climate change. Age structure, and its biological and socio-economic drivers, determine populations’ vulnerability to high temperatures. Here we combine age-stratified demographic projections with downscaled temperature projections to mid-century and find that chronic exposure to heat doubles across all warming scenarios. Moreover, >23% of the global population aged 69+ will inhabit climates whose 95th percentile of daily maximum temperature exceeds the critical threshold of 37.5 °C, compared with 14% today, exposing an additional 177–246 million older adults to dangerous acute heat. Effects are most severe in Asia and Africa, which also have the lowest adaptive capacity. Our results facilitate regional heat risk assessments and inform public health decision-making.

60 APPLIED LIFE SCIENCES↗