Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RPC background studies at CMS experiment

During Run2 the high instantaneous luminosity, up to 2.2 · 10 34 cm -2 s -1 , lead to a substantial hit rate in the Compact Muon Solenoid experiment’s muon chambers due to multiple background sources to physics processes sought for at LHC. In this article we will describe the analysis method devised to measure and identify the contributions to such background in the Resistive Plate Chambers. Thorough understanding of the background rates provides the base for the upgrade of the muon detectors for the High-Luminosity LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider

The Belle II experiment at the SuperKEKB electron–positron collider aims to collect an unprecedented data set of 50 ab -1 to study CP -violation in the B -meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world’s highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of 6 x 10 35 cm −2 s −1 by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to β $^*_y$ = 0.3 mm. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least 2.8 x 10 35 cm −2 s −1 is reached for β $^*_y$ = 0.6 mm. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates.

Detector background↗

Performance of a triple-GEM detector with capacitive-sharing 3-coordinate (X–Y–U)-strip anode readout

The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X--Y--U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using simple standard PCB fabrication techniques. Capacitive-sharing (X--Y--U)-strip readout allows simultaneous measurement of the Cartesian coordinates x and y of the position of the particles together with a third coordinate u along the diagonal axis in a single readout PCB. This provides a powerful tool to address multiple-hit ambiguity and enable pattern recognition capabilities in moderate particle flux environment of collider or fixed target experiments in high energy physics HEP) and nuclear physics (NP). We present in this paper the performance of a 10 cm × 10 cm triple-GEM detector with capacitive-sharing (X--Y--U)-strip anode readout. Spatial resolutions of the order of $\sigma_{x}^{res}$ = 71.6 $\pm$ 0.8 $\mu$m for X-strips, $\sigma_{y}^{res}$ = 56.2 $\pm$ 0.9 $\mu$m for Y-strips and $\sigma_{u}^{res}$ = 75.2 $\pm$ 0.9 $\mu$m for U-strips have been obtained at a beam test at Thomas Jefferson National Accelerator Facility (Jefferson Lab). Modifications of the readout design of future prototypes to improve the spatial resolution and challenges in scaling to large-area MPGDs are discussed.

(X-Y-U) strip↗

Design and construction of the CMS Outer Tracker for the phase-2 upgrade

The High-Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000–4000 fb −1 over 10 years of operation with the peak instantaneous luminosity reaching about 5–7.5 × 1 0 34 cm −2 s −1 . During Long Shutdown 3, several components of the CMS detector will undergo major improvements, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS tracker will be replaced. The Phase-2 Outer Tracker (OT) will have increased radiation tolerance, higher granularity, and the capability to handle higher data rates. Moreover, the OT will provide tracking information to the Level-1 trigger for the first time at a hadron collider, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules with two closely-spaced silicon sensors read out by front-end ASICs that can correlate hits in the two sensors to create short track segments, used in the Level-1 track finder. The modules come in two flavors: strip-strip and pixel-strip, containing different sensor configurations and multiple ASICs. This contribution presents the Phase-2 OT, the finalization of the OT module design, and the quality assurance and control procedures used to ensure that the modules fulfill both the specifications from the assembly steps as well as the proper communication among the ASICs.

Zoi, Irene [Fermilab] (ORCID:0000000257389446)↗

The imaging Time-of-Propagation detector at Belle II

Here, we report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB e + e - collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/ c . To date, the detector has been used to record and analyze almost 600 fb −1 of Belle II data.

43 PARTICLE ACCELERATORS↗

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test results of the Intermediate Silicon Tracker for sPHENIX

The Intermediate Silicon Tracker (INTT), a two-layer barrel silicon strip tracker, is a key component of the tracking system for sPHENIX at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The INTT is designed to enable the association of reconstructed tracks with individual RHIC bunch crossings. To evaluate the performance of preproduction INTT ladders and the readout chain, a beam test was conducted at the Research Center for Accelerator and Radioisotope Science, Tohoku University, Japan. This paper presents the performance of the INTT evaluated through studies of the signal-to-noise ratio, residual distribution, spatial resolution, hit-detection efficiency, and multiple track reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel↗

Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from to $\mathscr{L}$ = 4 x 10 32 cm -2 s -2 to $\mathscr{L}$ = 2 x 10 33 cm -2 s -1 . Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

Gaseous detectors↗

STK35L1 regulates host cell cycle-related genes and is essential for Plasmodium infection during the liver stage of malaria

Protein kinases of both the parasite and the host are crucial in parasite invasion and survival and might act as drug targets against drug-resistant malaria. STK35L1 was among the top five hits in kinome-wide screening, suggesting its role in malaria's liver stage. However, the role of host STK35L1 in malaria remains elusive. In this study, we found that STK35L1 was highly upregulated during the infection of Plasmodium berghei (P. berghei) in HepG2 cells and mice liver, and knockdown of STK35L1 remarkably suppressed the sporozoites' infection in HepG2 cells. We showed that STAT3 is upregulated and phosphorylated during P. berghei sporozoites' infection, and STAT3 activation is required for both the upregulation of STK35L1 and STAT3. Furthermore, we found that ten cell cycle genes were upregulated in the sporozoite-infected hepatocytes. Knockdown of STK35L1 inhibited the basal expression of these genes except CDKN3 and GTSE1 in HepG2 cells. Thus, we identified STK35L1 as a host kinase that plays an obligatory role in malaria's liver stage and propose that it may serve as a potential drug target against drug-resistant malaria.

60 APPLIED LIFE SCIENCES↗

Evaluation of Nanostructured β-Mn 2 V 2 O 7 Thin Films as Photoanodes for Photoelectrochemical Water Oxidation

β-Mn 2 V 2 O 7 (β-MVO) was recently reported to be a promising candidate for photoelectrochemical (PEC) water splitting, with a suitable band gap and band edge positions and reasonable stability and photoactivity in preliminary tests in alkaline solution. Here, we present an in-depth evaluation of the PEC performance and stability of phase-pure nanostructured β-Mn 2 V 2 O 7 films made by calcination of a spin-cast molecular ink. We show that β-Mn 2 V 2 O 7 dissolves in pure water, corrodes in aqueous electrolytes at pH 7 and 9, and converts to amorphous manganese (hydr)oxides within minutes at pH 13. Our β-Mn 2 V 2 O 7 films yielded only miniscule photocurrents (~uA cm -2 ) for the oxidation of iodide, sulfite, or water and the reduction of iodate or water in borate- and phosphate-buffered electrolytes at pH 7 and 9, the oxidation of [Fe(CN) 6 ] 4- or water at pH 13, and the oxidation of bromide in acetonitrile, regardless of film calcination temperature and time, film thickness, and illumination geometry. Minimal photoactivity was observed even in electrolytes in which film degradation was insignificant over the duration of the PEC tests. Ultrafast transient absorption spectroscopy shows that the poor photoactivity is likely the result of fast hole trapping and recombination at the MVO surface that leaves few free charge carriers beyond the picosecond time scale. Given its poor charge transport/extraction and chemical stability, native nanostructured β-Mn 2 V 2 O 7 is ineffective for solar water splitting and future research on this material should focus on the development of superior syntheses and film morphologies, MVO alloys, heterostructures, and surface coatings to alleviate recombination and boost operational stability. This work underscores the importance of careful follow-up studies of materials identified as "hits" in combinatorial materials discovery campaigns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Silico Guidance for In Vitro Androgen and Glucocorticoid Receptor ToxCast Assays

Molecular initiating events (MIEs) are key events in adverse outcome pathways (AOPs) that link molecular chemistry to target biology. As they are based in chemistry, these interactions are excellent targets for computational chemistry approaches to in silico modelling. In this work, we aim to link ligand chemical structure to MIEs for androgen receptor (AR) and glucocorticoid receptor (GR) binding using ToxCast data. This has been done using an automated computational algorithm to perform maximal common substructure searches on chemical binders for each target from the ToxCast dataset. The models developed show a high level of accuracy, correctly assigning 87.20% of AR binders and 96.81% of GR binders in a 25% test set using holdout cross-validation. The 2D structural alerts developed can be used as in silico models to predict these MIEs, and as guidance for in vitro ToxCast assays to confirm hits. These models can target such experimental work, reducing the number of assays to be performed to gain required toxicological insight. Development of these models has also allowed some structural alerts to be identified as predictors for agonist or antagonist behavior at the receptor target. This work represents a first step in using computational methods to guide and target experimental approaches.

Allen, Timothy H.↗

PubChemLite Plus Collision Cross Section (CCS) Values for Enhanced Interpretation of Nontarget Environmental Data

Finding relevant chemicals in the vast (known) chemical space is a major challenge for environmental and exposomics studies leveraging nontarget high resolution mass spectrometry (NT-HRMS) methods. Chemical databases now contain hundreds of millions of chemicals, yet many are not relevant. This article details an extensive collaborative, open science effort to provide a dynamic collection of chemicals for environmental, metabolomics, and exposomics research, along with supporting information about their relevance to assist researchers in the interpretation of candidate hits. The PubChemLite for Exposomics collection is compiled from ten annotation categories within PubChem, enhanced with patent, literature and annotation counts, predicted partition coefficient (logP) values, as well as predicted collision cross section (CCS) values using CCSbase. Monthly versions are archived on Zenodo under a CC-BY license, supporting reproducible research, and a new interface has been developed, including historical trends of patent and literature data, for researchers to browse the collection. This article details how PubChemLite can support researchers in environmental and exposomics studies, describes efforts to increase the availability of experimental CCS values, and explores known limitations and potential for future developments. The data and code behind these efforts are openly available.

PubChem↗

AI-Accelerated Design of Targeted Covalent Inhibitors for SARS-CoV-2

Direct-acting antivirals for the treatment of the COVID-19 pandemic caused by the SARS-CoV-2 virus are needed to complement vaccination efforts. Given the ongoing emergence of new variants, automated experimentation, and active learning based fast workflows for antiviral lead discovery remain critical to our ability to address the pandemic’s evolution in a timely manner. While several such pipelines have been introduced to discover candidates with noncovalent interactions with the main protease (M pro ), here we developed a closed-loop artificial intelligence pipeline to design electrophilic warhead-based covalent candidates. Here, this work introduces a deep learning-assisted automated computational workflow to introduce linkers and an electrophilic “warhead” to design covalent candidates and incorporates cutting-edge experimental techniques for validation. Using this process, promising candidates in the library were screened, and several potential hits were identified and tested experimentally using native mass spectrometry and fluorescence resonance energy transfer (FRET)-based screening assays. We identified four chloroacetamide-based covalent inhibitors of M pro with micromolar affinities (K I of 5.27 μM) using our pipeline. Experimentally resolved binding modes for each compound were determined using room-temperature X-ray crystallography, which is consistent with the predicted poses. The induced conformational changes based on molecular dynamics simulations further suggest that the dynamics may be an important factor to further improve selectivity, thereby effectively lowering KI and reducing toxicity. These results demonstrate the utility of our modular and data-driven approach for potent and selective covalent inhibitor discovery and provide a platform to apply it to other emerging targets.

60 APPLIED LIFE SCIENCES↗

Simulations of Attosecond Metallization in Quartz and Diamond Probed with Inner-Shell Transient Absorption Spectroscopy

When dielectrics are hit with intense infrared (IR) laser pulses, transient metalization can occur. The initial attosecond dynamics behind this metallization are not entirely understood. Therefore, simulations are needed to understand this process and to help interpret experimental observations of it, such as with attosecond transient absorption (ATA). In this paper, we present first-principles simulations of ATA based on bulk-mimicking clusters and real-time time-dependent density functional theory (RT-TDDFT), with Koopmans-tuned range-separated hybrid functionals and Gaussian basis sets. Our method gives good agreement with the experiment for the breakdown threshold in silica and diamond. This breakdown voltage corresponds to a Keldysh parameter of approximately one and thus involves a transition to a regime where the dynamics are driven by tunneling. Pumping at an amplitude just below this value causes a mixture of multiphoton and tunneling excitations across the band gap to occur. The computed extreme ultraviolet and X-ray attosecond transient spectra also agree well with the experiment and show a decrease in optical density due to the transient population of the conduction band from the IR field. First-principles approaches such as this are valuable for interpreting the complicated modulations in a spectrum and for guiding future attosecond experiments on solids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗