Search NASA⌕ Search

SEARCH · Search NASA

Results for “High vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Semi-metallic SrIrO 3 films using solid-source metal-organic molecular beam epitaxy

Perovskite SrIrO 3 films and its heterostructures are very promising, yet less researched, avenues to explore interesting physics originating from the interplay between strong spin–orbit coupling and electron correlations. Elemental iridium is a commonly used source for molecular beam epitaxy (MBE) synthesis of SrIrO 3 films. However, elemental iridium is extremely difficult to oxidize and evaporate while maintaining an ultra-high vacuum and a long mean free path. Here, we calculated a thermodynamic phase diagram to highlight these synthesis challenges for phase-pure SrIrO 3 and other iridium-based oxides. We addressed these challenges using a novel solid-source metal-organic MBE approach that rests on the idea of modifying the metal-source chemistry. Phase-pure, single-crystalline, coherent, epitaxial (001) pc SrIrO 3 films on (001) SrTiO 3 substrate were grown. Films demonstrated semi-metallic behavior, Kondo scattering, and weak antilocalization. Our synthesis approach has the potential to facilitate research involving iridate heterostructures by enabling their atomically precise syntheses.

36 MATERIALS SCIENCE↗

Silicon source for vacuum deposition

Device using two independent silicon sources for ultra-high-vacuum deposition on large substrates can deposit P and N types of silicon simultaneously. Efficient water cooled copper shield supports and cools structure and isolates two filaments.

Racette, G. W.↗

Enhanced surface superconductivity in Ba(Fe 0.95 Co 0.05 ) 2 As 2

We present direct evidence for an enhanced superconducting Tc on the surface of cleaved single crystals of Ba(Fe 0.95 Co 0.05 ) 2 As 2 . Transport measurements performed on samples cleaved in ultra-high vacuum show a significantly enhanced superconducting transition when compared to equivalent measurements performed in air. Deviations from the bulk resistivity appear at 21 K, well above the 10 K bulk Tc of the underdoped compound. We demonstrate that the excess conductivity above the bulk Tc can be controllably suppressed by application of potassium ions on the cleaved surface, indicating that the enhanced superconductivity is strongly localized to the sample surface. Additionally, we find that the effects of the potassium surface dosing are strongly influenced by the presence of residual gas absorbates on the sample surface, which may prevent effective charge transfer from the potassium atoms to the FeAs plane. This further supports the conclusion that the effects of the dosing (and enhanced superconductivity) are localized within a few layers of the surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thoughts on the past, present and future of UHV surface chemistry and the birth of Single-Atom Alloys

Throughout its relatively short lifetime, ultra-high vacuum (UHV) surface chemistry has progressed quickly. In the 1960's, pioneers like Ertl and Somorjai started the field using single crystals and gained significant insight into catalytic processes by relating surface structure to reactivity. The more recent proliferation of scanning probes has significantly increased the power of the single crystal approach by enabling the atomic-scale structure of active sites to be correlated with their reactivity. In this perspective we briefly discuss how the field developed, identify some challenges, and highlight Single-Atom Alloys (SAAs), a new class of heterogeneous catalyst that was developed from a fundamental surface science approach. However, despite recent successes, funding for fundamental surface science has declined. Academic hires in the discipline are also declining in part due to the start-up costs. We make the case that fundamental UHV surface chemistry is still too young a field to be in recession.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single layer graphene protective layer on GaAs photocathodes for spin-polarized electron source

GaAs-based photocathodes are the primary choice for polarized electron sources, commonly used in polarized electron microscopes and polarized positron sources. GaAs photocathodes are typically activated with cesium and oxygen, which are highly reactive and require an ultra-high vacuum (⁠~ 10 -11 Torr or lower) to operate reliably, resulting in substantial operational difficulties. A short exposure to a mediocre vacuum results in an instantaneous loss of cathode quantum efficiency (QE) due to the chemical reaction of the active layer with residual gas molecules or back-bombardment ions during operation. Covering the GaAs cathode with a 2D material, such as monolayer graphene, could provide protection against such damage due to the inhibition of chemical reactions with residual gas molecules. In this paper, we have incorporated a method known as intercalation to pass the active material underneath the graphene and activate the superlattice GaAs/GaAsP (SL-GaAs) photocathode. X-ray photoelectron spectroscopy, low-energy electron microscopy, and Mott scattering measurements were performed to evaluate the formation of the photocathode under graphene, as well as its spectral response and electron spin polarization. Our results demonstrate that the successful activation of the SL-GaAs photocathode with a graphene protection layer is achieved with a moderate QE. Furthermore, we found that the electron spin polarization of the cathode with a surface protection layer is higher than the conventional cathode without a protection layer.

2D materials↗

Ion Storage Tests with the High Performance Antimatter Trap (HiPAT)

The NASA/Marshall Space Flight Centers (NASA/MSFC) Propulsion Research Center (PRC) is evaluating an antiproton storage system, referred to as the High Performance Antiproton Trap (HiPAT). This interest stems from the sheer energy represented by matter/antimatter annihilation process with has an energy density approximately 10 order of magnitude above that of chemical propellants. In other terms, one gram of antiprotons contains the equivalent energy of approximately 23 space shuttle external tanks or ET's (each ET contains roughly 740,000 kgs of fuel and oxidizer). This incredible source of stored energy, if harnessed, would be an enabling technology for deep space mission where both spacecraft weight and propulsion performance are key to satisfying aggressive mission requirements. The HiPAT hardware consists of a 4 Tesla superconductor system, an ultra high vacuum test section (vacuum approaching 10(exp -12) torr), and a high voltage confinement electrode system (up to 20 kvolts operation). The current laboratory layout is illustrated. The HiPAT designed objectives included storage of up to 1 trillion antiprotons with corresponding lifetimes approaching 18 days. To date, testing has centered on the storage of positive hydrogen ions produced in situ by a stream of high-energy electrons that passes through the trapping region. However, due to space charge issues and electron beam compression as it passes through the HiPAT central field, current ion production is limited to less then 50,000 ions. Ion lifetime was determined by counting particle populations at the end of various storage time intervals. Particle detection was accomplished by destructively expelling the ions against a micro-channel plate located just outside the traps magnetic field. The effect of radio frequency (RF) stabilization on the lifetime of trapped particles was also examined. This technique, referred to as a rotating wall, made use of a segmented electrode located near the center of the trap on which various phases of a particular frequency were applied. Various experiments were performed illustrating the ability of an RF drive to both prolong and reduced the lifetimes of various ion species depending on the selected frequency. HiPAT is now being reconfigured for testing with an ion source that will provide both positive and negative hydrogen ions from an external source. This ion system shall provide higher fill capacity (order of million of ions per shot), stacking of multiple shots, and injection schemes typical of a realistic antiproton delivery system.

Martin, James J.↗

Compound Walls For Vacuum Chambers

Proposed compound-wall configuration enables construction of large high-vacuum chambers without having to use thick layers of expensive material to obtain necessary strength. Walls enclose chambers more than 1 m in diameter and several kilometers long. Compound wall made of strong outer layer of structural-steel culvert pipe welded to thin layer of high-quality, low-outgassing stainless steel.

Frazer, Robert E.↗

Solid-film lubricant is effective at high temperatures in vacuum

Calcium fluoride with a suitable inorganic binder forms a stable solid-film lubricant when fused to the surface to be lubricated. It is effective in environments at elevated temperatures and gas pressures ranging from atmospheric to high vacuum. It is not stable in reducing atmospheres.

Sliney, H. E.↗

Housing protects laser in vacuum

Airtight housing encloses laser for easy alinement and operation in high-vacuum chamber. Beam is transmitted through window into vacuum chamber. Flexible line runs through vacuum chamber to outside, maintaining laser enclosure at atmospheric pressure.

Canali, V. G.↗

Laser Induced Rotation of a Levitated Sample in Vacuum

A method of systematically controlling the rotational state of a sample levitated in a high vacuum using the photon pressure is described. A zirconium sphere was levitated in the high-temperature electrostatic levitator and it was rotated by irradiating it with a narrow beam of a high power laser on a spot off the center of mass.

laser induced rotation electrostatic levitator↗

Correlating Nb-SRF Surface Processing with Evolution of Surface Electronic States

The few nanometers of the surface exposed to RF field plays a major role in defining the RF performance of superconducting cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in cavity performance by simultaneously achieving high Q with increasing Eacc. These processing methods include: thermal treatment under ultra-high vacuum (UHV) conditions across lo¬¬¬¬¬¬¬w-, mid-, and high-temperature ranges and high temperature treatments under controlled N2 atmosphere. These processes also produce distinct surface oxide configurations with different valence states, thicknesses, and uniformity, as well as different oxygen concentration profiles in bulk Nb. In this work, we are trying to understand how do surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity? With the help of Fermilab’s in-house X-ray photoemission facility and, in collaboration with the synchrotron-based angle-resolved photoemission (ARPES) facility at Argonne National Laboratory, we are investigating how the valence band structure and density of states (DoS) near the Fermi level modify with different surface treatments. Our observations show that different surface-processing methods lead to distinct evolutions of the valence-band states near the Fermi level during the superconducting transition. This behavior suggests variations in Nb-O orbital hybridizations and points towards the possibility of different underlying mechanisms of superconductivity governed by the surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in SRF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of SRF cavities.

Tripathi, Malvika [Fermilab]↗

Vacuum in the wake of space vehicles

Vacuum conditions to be encountered in the wakes of high altitude unmanned space vehicles are calculated in order to demonstrate possibilities for conducting experiments using the high pumping speeds and very high vacuum (down to 10 to the -15th torr) attainable. The flux of ambient particles backscattered by emissions from spacecraft surfaces is modelled for an idealized Long Duration Exposure Facility spacecraft structure in an orbit of 550 km altitude. The total backscattered fluxes are found to be between 3 x 10 to the 4th and 3 x 10 to the 5th per sq cm sec for H and between 10 to the 6th and 10 to the 7th per sq cm sec for He and O, depending on the angle with respect to the wake axis. It is found that the direct ambient hydrogen flux is an order of magnitude greater than the backscattered flux, while the backscattered fluxes of He and O are greater than the direct fluxes. It is pointed out that care should be taken in designing space experiments to enable these theoretical conditions to be met.

Oran, W. A.↗

Testing Long-Term Exposure To Vacuum

Facility for studying long-term effects of vacuum on materials described in report. Vacuum storage system maintains specimens at constant temperature and high vacuum. Enables specimens to be removed easily and safely for analysis. Nitrogen storage system maintains specimens at 77 degree F in pure, dry nitrogen gas under gauge pressure of 2 to 4 psi. Enables comparison of control specimens with specimens exposed to vacuum. Instrumentation-and-control system measures and records operating parameters and generates control signals and alarm indications as necessary.

Clark, D. L.↗

Fluid Dynamics of Small, Rugged Vacuum Pumps of Viscous-Drag Type

The need to identify spikes in the concentration of hazardous gases during countdowns to space shuttle launches has led Kennedy Space Center to acquire considerable expertise in the design, construction, and operation of special-purpose gas analyzers of mass-spectrometer type. If such devices could be miniaturized so as to fit in a small airborne package or backpack them their potential applications would include integrated vehicle health monitoring in later-generation space shuttles and in hazardous material detection in airports, to name two examples. The bulkiest components of such devices are vacuum pumps, particularly those that function in the low vacuum range. Now some pumps that operate in the high vacuum range (e.g. molecular-drag and turbomolecular pumps) are already small and rugged. The present work aims to determine whether, on physical grounds, one may or may not adopt the molecular-drag principle to the low-vacuum range (in which case viscous-drag principle is the appropriate term). The deliverable of the present effort is the derivation and justification of some key formulas and calculation methods for the preliminary design of a single-spool, spiral-channel viscous-drag pump.

Russell, John M.↗

Rod and dish cathode improves penning-type vacuum gage

Improved penning-type ionization gage provides range and sensitivity required to measure gas pressure below .01 torr under high vacuum conditions. The gage uses a highly conductive cathode composed of two disks of high magnetic permeability separated by a rod of low magnetic permeability.

Peppin, G. B.↗

Advanced Engraving Of Angle-Encoder Disks

Precision increased over mechanical engravers. Laser pulses timed according to rotational speed of rotor electrostatically suspended in vacuum marks angular-encoder disk mounted on lower end of rotor. Precision of timing circuitry and low rotational damping (damping time about 700 years in high vacuum) results in highly-precise angular intervals. System conceived to meet need for increased precision of angular measurements in advanced scientific instruments.

Polstorff, Walter K.↗