A Stokes' velocity photographic method for measuring the size distribution of aerosols

Aerosol particles are allowed to settle in a vertical glass walled vessel, and their settling velocity is determined by photographing them while the light entering the camera is being chopped at a known rate. The settling velocity of each particle can be determined from the photographs, and by applying the Stokes' law, one can calculate the radius of each particle. The Stokes' law for a sphere settling freely in a quiet medium is given. If the volume of the photographed region of the illumination is known, the aerosol number density and size distribution can be obtained. Experiments with alumina particles of given size distributions indicate that the method works accurately. One set of a typical experiment with 3.0-micrometer Al2O3 particles is presented, which shows that the measured size distribution peaks at approximately 3.0 micrometer.

Deepak, A.↗

An Evaluation of Four Experimental Methods for Measuring Mean Properties of a Supersonic Turbulent Boundary Layer

Surveys were made through a turbulent boundary layer on a flat plate by means of a pitot probe, an x-ray densitometer, and hot-wire and cold-wire probes. Results from these surveys were analyzed to determine (a) the reliability of the basic data and hence the methods by which they were obtained, and (b) how well the actual distributions of properties in the boundary layer compare with those commonly assumed in semiempirical and theoretical analyses. All surveys were made at the same longitudinal station on the flat plate. The tests were conducted in a an 8- by 8-inch supersonic nozzle. The free-stream Mach number was 3.03 and the Reynolds number was approximately 210,000 based on boundary-layer thickness.

Nothwang, George J↗

A new method of measurement of tension on a moving magnetic tape

The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

Kurtinaytis, A. K.↗

Quantitative Method of Measuring Metastatic Activity

The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated uroldnase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

Morrison, Dennis R.↗

A simple method to measure the isosteric energy of adsorption

The effect of temperature on water vapour desorption isotherms can be described simply using the Clausius-Clapeyron equation and the isosteric energy of adsorption, the latter conventionally estimated using two (or more) isotherms obtained at different temperatures. This approach has some disadvantages, however, and this article puts forward a simple alternative methodology for characterising this isosteric energy experimentally. Our method is based on monitoring the relative humidity of a cementitious material heated under sealed conditions. The evolution of the relative humidity as a function of temperature makes it possible to directly evaluate the isosteric energy. In practice, the tests are performed using a cell of the type that is used for self-desiccation studies.

36 MATERIALS SCIENCE↗

Area-based composition predictions of materials fabricated using simultaneous wire-powder-directed energy deposition

Functionally graded materials are an emergent method for designing components with programmable site-specific material properties. These materials are typically fabricated using metal additive manufacturing tools by simultaneously feeding multiple wire and/or powder feedstocks at various rates to achieve spatial composition change. The wire-powder-directed energy deposition (WP-DED) technique is of particular interest for many functionally graded material applications by balancing the low raw materials cost of wire with the high resolution of powder. However, feeding wire and powder are inherently different processes since all extruded wire enters the melt pool, while much of the blown powder is scattered, which makes determining the composition of the build challenging. In this study, we devise a simple area-based measurement method for estimating the composition of WP-DED structures. WP-DED single beads are printed using 309L stainless steel wire and commercially pure Fe powder at five wire feed rates (0.5, 0.75, 1.00, 1.25, 1.50 mm/mm) and five powder feed rates (2, 4, 6, 8, 10 rpm). Characteristic defects including interface gaps and macrosegregation (lack of mixing) tendencies are examined. High powder feed rates (8, 10 rpm) result in interface gaps at all wire feed rates, but smooth deposition and complete mixing is achieved at low powder feed rates, particularly with lower wire feed rates as well. The area-based composition measurement method is within ±20% of energy dispersive x-ray spectroscopy measurements for all samples, showing its effectiveness as a rapid composition estimate for WP-DED materials development.

36 MATERIALS SCIENCE↗

Quantitative method of measuring cancer cell urokinase and metastatic potential

The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated urokinase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

Morrison, Dennis R.↗

Instrumentation for Application Number 1: Mass Spectrometric Analysis of the Boundary Layer Associated with the Tethered Satellite

Knowledge about the boundary layer associated with high enthalpy flow fields has mostly been derived from measurements of physical properties. To further this understanding, the chemistry of the gaseous layer must be studied as well. This requires that instrumentation and measurement methods be developed that can analyze the gases while having a minimal effect on the flow field and composition. Because of its sensitivity and ability to identify species, the mass spectrometer is the most promising instrument for this application, although other spectroscopic methods are being evaluated as well. There are, however, several non-trivial problems that must be solved in order to apply the mass spectrometer, including the obtaining of a representative sample from near the model surface. These problems are being addressed in a research program to develop qualitative and quantitative measurement methods to examine the gas chemistry in several large hot-gas blowdown facilities, and to study the aerodynamics of the boundary layer associated with models in these facilities and in instrumented hypersonic vehicles. These methods can also be applied to the tethered satellite, which will provide a unique opportunity to obtain aerothermodynamic data that is unaltered by effects from the test facility.

Wood, G. M.↗

Technical and investigative support for high density digital satellite recording systems

Methods and results of examinations and tests conducted on magnetic recording tapes under consideration for a high density digital (HDDR) satellite recording system are described. The examinations and tests investigate the performance of tapes with respect to their physical, magnetic and electrical characteristics. The objective of the tests, the likely significance of typical results, and the importance of the characteristics under investigation to the application are included. Theoretical discussions of measurement methods are provided where appropriate. Methods and results are discussed; the results of some sections are tabulated together to facilitate their comparison. The conclusion of each test section relates the test results to their possible significance and attempts to correlate the results of that section with the results of other tests. Some of the sections analyze sources of error inherent in the measurement methods or relate the value of the information obtained to the objectives of the test or the overall purpose of the project.

Schultz, R. A.↗

Modern chemical graph theory

Abstract Graph theory has a long history in chemistry. Yet as the breadth and variety of chemical data is rapidly changing, so too do graph encoding methods and analyses that yield qualitative and quantitative insights. Using illustrative cases within a basic mathematical framework, we showcase modern chemical graph theory's utility in Chemists' analysis and model development toolkit. The encoding of both experimental and simulation data is discussed at various levels of granularity of information. This is followed by a discussion of the two major classes of graph theoretical analyses: identifying connectivity patterns and partitioning methods. Measures, metrics, descriptors, and topological indices are then introduced with an emphasis upon enhancing interpretability and incorporation into physical models. Challenging data cases are described that include strategies for studying time dependence. Throughout, we incorporate recent advancements in computer science and applied mathematics that are propelling chemical graph theory into new domains of chemical study. This article is categorized under: Molecular and Statistical Mechanics > Molecular Dynamics and Monte‐Carlo Methods Structure and Mechanism > Computational Materials Science Structure and Mechanism > Molecular Structures

Leite, Leonardo S. G.↗

Systems and methods for dual comb spectroscopy

A frequency-measurement method uses a dual frequency-comb spectrometer as an optical wavemeter to measure the frequency of a reference laser that is used to frequency-stabilize the spectrometer. The method includes measuring a walking rate of center bursts in a sequence of interferograms recorded by the spectrometer, determining a number of teeth in each of a plurality of Nyquist windows formed by the dual frequency-comb spectrometer, and determining a Nyquist number of the one Nyquist window covering the laser frequency. The reference laser frequency can then be determined from the number of teeth in each Nyquist window, the Nyquist number, and the comb spacing of either one of the two frequency combs of the dual frequency-comb spectrometer. The reference laser frequency does not need to be measured with a separate wavemeter, or calibrated with respect to a known atomic or molecular transition.

Rieker, Gregory B.↗

A method of measuring the amplitude-modulated vacuum field near a conducting mirror

Electromagnetic fields of the vacuum mode near a conducting mirror are modified with respect to those in free space, with their amplitudes having a sinusoidal spatial dependence from the mirror. Therefore if we combine this spatially amplitude-modulated vacuum field mode and intense coherent light with a beam splitter, we may detect this fluctuation of the vacuum mode in a homodyne detection scheme. It will give a new method to produce squeezed states of light with a single mirror placed close to an unused port of a beam splitter. We show that the amplitude fluctuation of the combined light can be reduced by a factor of 2 below that of the coherent light. We also discuss the limitations due to the finite line width of the laser and the effective absorption length of the photodiodes.

Youn, Sun-Hyun↗

ATR-SEIRAS Method to Measure Interfacial pH during Electrocatalytic Nitrate Reduction on Cu

This study reports the accuracy and applications of an attenuated total reflectance–surface-enhanced infrared absorption spectroscopy (ATR–SEIRAS) technique to indirectly measure the interfacial pH of the electrolyte within 10 nm of the electrocatalyst surface. This technique can be used in situ to study aqueous electrochemical reactions with a calibration range from pH 1–13, time resolution down to 4 s, and an average 95% confidence interval of 14% that varies depending on the pH region (acidic, neutral, or basic). The method is applied here to electrochemical nitrate reduction at a copper cathode to demonstrate its capabilities, but is broadly applicable to any aqueous electrochemical reaction (such as hydrogen evolution, carbon dioxide reduction, or oxygen evolution) and the electrocatalyst may be any SEIRAS-active thin film (e.g., silver, gold, or copper). The time-resolved results show a dramatic increase in the interfacial pH from pH 2–7 in the first minute of operation during both constant current and pulsed current experiments where the bulk pH is unchanged. Attempts to control the pH polarization at the surface by altering the electrochemical operating conditions—lowering the current or increasing the pulse frequency—showed no significant change, demonstrating the challenge of controlling the interfacial pH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity and comparison evaluation of Saturn 5 liquid penetrants

Results of a sensitivity and comparison evaluation performed on six liquid penetrants that were used on the Saturn 5 vehicle and other space hardware to detect surface discontinuities are described. The relationship between penetrant materials and crack definition capabilities, the optimum penetrant materials evaluation method, and the optimum measurement methods for crack dimensions were investigated. A unique method of precise developer thickness control was envolved, utilizing clear radiographic film and a densitometer. The method of evaluation included five aluminum alloy, 2219-T87, specimens that were heated and then quenched in cold water to produce cracks. The six penetrants were then applied, one at a time, and the crack indications were counted and recorded for each penetrant for comparison purposes. Measurements were made by determining the visual crack indications per linear inch and then sectioning the specimens for a metallographic count of the cracks present. This method provided a numerical approach for assigning a sensitivity index number to the penetrants. Of the six penetrants evaluated, two were not satisfactory (one was not sufficiently sensitive and the other was to sensitive, giving false indications). The other four were satisfactory with approximately the same sensitivity in the range of 78 to 80.5 percent of total cracks detected.

Jones, G. H.↗

Challenges for the statistical gravitational-wave method to measure the Hubble constant

Gravitational waves (GW) can be employed as standard sirens that will soon measure the Hubble constant with sufficient precision to weigh in on the ~5σ Hubble tension. Most GW sources will have no identified electromagnetic counterpart, leading to uncertainty in the redshift of the source, and in turn a degeneracy between host galaxy distance, redshift, and H 0 . In the case where no electromagnetic counterparts are identified, it has been proposed that a statistical canvassing of candidate GW hosts, found in a large galaxy survey for example, can be used to accurately constrain the Hubble constant. We study and simulate this "galaxy voting" method to compute H 0 . Here, we find that the Hubble constant posterior is in general biased relative to the true value even when making optimistic assumptions about the statistical properties of the sample. Using the MICECAT light-cone catalog, we find that the bias in the H0 posteriors depends on the realization of the underlying galaxy sample and the precision of the GW source distance measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

A Novel Variable Extensometer Method for Measuring Ductility Scaling Parameters From Single Specimens

Abstract Macro-scale ductility is not an intrinsic material property but is dependent on the overall geometry of the specimen. To account for variety in specimen geometries, multiple ductility scaling laws have been developed, which scale ductility between different specimen sizes. Traditionally, these ductility laws rely on testing multiple different specimens of varying sizes to obtain material parameters, often done by varying gauge lengths. With the use of digital image correlation (DIC), this study presents a technique where multiple different gauge lengths are extracted from a single specimen to obtain ductility scaling parameters from a single experiment. This technique provides orders of magnitude more data from each specimen than previous techniques. This variable extensometer method is then validated by testing multiple different geometries, and select scaling laws are then compared.

Mechanics↗

Data Analytics Methods to Measure Plant Outage Resilience

Every 18 or 24 months nuclear power plants (depending on plant configuration, pressurized or boiling water reactor respectively) undergo a period of outage where the plant is taken offline and a large number of maintenance and surveillance activities (that cannot be performed while plant is running) are performed in typically 2–3 weeks. Planning of a plant outage is very challenging since all the activities are required to be performed in the shortest amount of time given available resources (typically contractor crews hired for the duration of the outage). Consequently, plant outages can be costly due the actual loss of power generation and crew costs and, because of it, there is a need to maximize resource usage in the outage planning phase and reduce the risk of outage delays. This paper is addressing these needs by providing a set of analytical methods designed to analyze plant outage schedule and identify critical elements based on available resources (time and crews). These methods are based on natural language processing and optimization algorithms. In this respect, two classes of methods have been developed: one that focuses on the time resource and how variability in the time to complete outage tasks may impact outage delays, and one that minimizes the risk of outage delays by integrating available resources to assess when daily activities should be performed.

97 - MATHEMATICS AND COMPUTING↗

A Method for Measuring the Effective Throughput Time Delay in Simulated Displays Involving Manual Control

The advent and widespread use of the computer-generated image (CGI) device to simulate visual cues has a mixed impact on the realism and fidelity of flight simulators. On the plus side, CGIs provide greater flexibility in scene content than terrain boards and closed circuit television based visual systems, and they have the potential for a greater field of view. However, on the minus side, CGIs introduce into the visual simulation relatively long time delays. In many CGIs, this delay is as much as 200 ms, which is comparable to the inherent delay time of the pilot. Because most GCIs use multiloop processing and smoothing algorithms and are linked to a multiloop host computer, it is seldom possible to identify a unique throughput time delay, and it is therefore difficult to quantify the performance of the closed loop pilot simulator system relative to the real world task. A method to address these issues using the critical task tester is described. Some empirical results from applying the method are presented, and a novel technique for improving the performance of GCIs is discussed.

Jewell, W. F.↗