Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Modeling of a Low-Background Spectroscopic Position-Sensitive Neutron Detector

A new low-background spectroscopic direction-sensitive neutron detector that would allow one to reduce the neutron background component in passive and active neutron detection techniques is proposed. The detector is based on thermal neutron detectors surrounded by a fast neutron scintillation detector, which serves at the same time as a neutron moderator. Direction sensitivity is achieved by coincidence/anticoincidence analysis between different parts of the scintillator. Results of mathematical modeling of several detector configurations are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron interferometry detection of early crack formation caused by bending fatigue in additively manufactured SS316 dogbones

In our research, fatigue in selective laser melted (SLM) and conventionally manufactured stainless steel (SS) 316 dogbones was studied with neutron imaging methods for attenuation, diffraction, and scattering. Neutron attenuation tomography and Bragg edge imaging did not reveal crack formation. Conversely, to efficiently detect the microcrack evolution, two methods of grating-based neutron interferometry, Talbot-Lau and far-field, were employed. Both interferometry methods detect early crack formation via the dark-field (scattering) images, especially for porous microstructures in the range of 0.6 μm to 2 μm. The dark-field image combines sensitivity to micrometer-sized scattering centers at crack formation with sub-millimeter imaging resolution. The crack formation observed with neutron interferometry dark-field was validated post-imaging with additional fatigue cycles to fracture. Further inspection was performed by scanning electron microscopy (SEM) and optical photography. In the two fatigued dogbones, SLM and conventional crack formation was determined to within 1 mm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fresh Fuel Measurements With the Differential Die-Away Self-Interrogation Instrument

The purpose of the Next Generation Safeguards Initiative (NGSI)-Spent Fuel (SF) Project is to strengthen the technical toolkit of safeguards inspectors and/or other interested parties. Thus the NGSI-SF team is working to achieve the following technical goals more easily and efficiently than in the past using nondestructive assay measurements of spent fuel assemblies: 1) verify the initial enrichment, burnup, and cooling time of facility declaration; 2) detect the diversion or replacement of pins; 3) estimate the plutonium mass; 4) estimate decay heat; and 5) determine the reactivity of spent fuel assemblies. The differential die-away self-interrogation (DDSI) instrument is one instrument that was assessed for years regarding its feasibility for robust, timely verification of spent fuel assemblies. The instrument was recently built and was tested using fresh fuel assemblies in a variety of configurations, including varying enrichment, neutron absorber content, and symmetry. The early die-away method, a multiplication determination method developed in simulation space, was successfully tested on the fresh fuel assembly data and determined multiplication with a root-mean-square (RMS) error of 2.9%. The experimental results were compared with MCNP simulations of the instrument as well. Low multiplication assemblies had agreement with an average RMS error of 0.2% in the singles count rate (i.e., total neutrons detected per second) and 3.4% in the doubles count rates (i.e., neutrons detected in coincidence per second). High-multiplication assemblies had agreement with an average RMS error of 4.1% in the singles and 13.3% in the doubles count rates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterizing the Performance of Fission Chambers for Local Neutron Flux and Spectrum Measurement

Three fission chambers were tested at The Ohio State University Research Reactor (OSURR) to evaluate fission chambers for neutron flux and spectrum measurements. Two of the fission chambers are commercial Photonis CFUR43 fission chambers—one utilizing highly enriched uranium-235 fissile deposits for thermal neutron detection and the other with highly depleted uranium-238 for fast neutron detection. This experiment was also performed in collaboration with French Alternative Energies and Atomic Energy Commission (CEA) with CEA suppling a uranium-235 loaded fission chamber built from the Photonis CFPR CE8/9 kit. The fission chambers were irradiated in a movable 6.5 inch dry tube at reactor powers of 50 kW, 200 kW, and 450 kW at ambient temperature and at 350°C. While all sensors demonstrated good linear sensitivity to reactor power, a leakage current of 6 nA was measured for the CFUR43 detectors. Additionally, the measured signal ratios of the two CFUR43 detectors did not match the theoretical values and are subject to further investigation on individual signal contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of uncertainties for subcritical benchmark measurements - 14387

Subcritical measurements are used for many applications including nonproliferation, treaty verification, in-situ monitoring for criticality, and reactor subcriticality monitoring. Most analysis methods involve correlated neutron detection, based upon the property that fission events can create multiple neutrons that are born at nearly the same time (on a scale of 10{sup -13} or 10{sup -14} seconds). Many different time-correlated methods have been used since the 1950's and are still widely utilized today. This particular work describes an uncertainty analysis of measured data using the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. The Feynman Variance-to-Mean method was introduced by Feynman et al. in 1956 and is based upon the differences between the detector count data and the data that would be expected from measurements taken from a Poissonian source. The Hage-Cifarelli formalism relates moments of the Feynman histograms to several parameters of a system: leakage multiplication (M{sub L}), spontaneous fission rate (F{sub S}), (α,n) neutron emission rate (S{sub α}), detector efficiency (ε), and the moments of the number of neutrons emitted per fission (ν). The first part of the uncertainty method described in this work will show how to determine uncertainties of the first (R{sub 1}) and second (R{sub 2}) reduced factorial moments of the Feynman histograms. The second part of the method will describe how to determine the uncertainties in the other parameters given uncertainties in the reduced factorial moments; in particular, this work will focus on determining the uncertainties in M{sub L} and F{sub S}. This work will utilize measured data from a recent benchmark evaluation with a 4.5 kg sphere of α-phase plutonium to validate the uncertainty analysis. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pillar Structured Thermal Neutron Detector

This work describes an innovative solid state device structure that leverages advanced semiconductor fabrication technology to produce an efficient device for thermal neutron detection which we have coined the 'Pillar Detector'. State-of-the-art thermal neutron detectors have shortcomings in simultaneously achieving high efficiency, low operating voltage while maintaining adequate fieldability performance. By using a three dimensional silicon PIN diode pillar array filled with isotopic {sup 10}boron ({sup 10}B), a high efficiency device is theoretically possible. Here we review the design considerations for going from a 2-D to 3-D device and discuss the materials trade-offs. The relationship between the geometrical features and efficiency within our 3-D device is investigated by Monte Carlo radiation transport method coupled with finite element drift-diffusion carrier transport simulations. To benchmark our simulations and validate the predicted efficiency scaling, experimental results of a prototype device are illustrated. The fabricated pillar structures reported in this work are composed of 2 {micro}m diameter silicon pillars with a 2 {micro}m spacing and pillar height of 12 {micro}m. The pillar detector with a 12 {micro}m height achieved a thermal neutron detection efficiency of 7.3% at a reverse bias of -2 V.

36 MATERIALS SCIENCE↗

Scintillation neutron detectors based on solid-state photomultipliers and lightguides

Neutron detectors based on scintillation screens ZnS(Ag)/LiF and solid-state photomultipliers have been developed. Lightguides are used to collect light. The application of a coincidence scheme provides a low dark count and a neutron detection efficiency as high as 70%. A scheme of x-y neutron detector based on wavelength shifting fibers is also proposed. Tests of the proposed versions of detectors in a neutron beam have shown their efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photofission of {sup 238}U in the giant-resonance region

Data on cross sections for the reaction {sup 238}U(γ,F) in the giant-resonance region were analyzed in connection with the preparation of new experiments aimed at studying {sup 238}U photofission—in particular, in beams of photons from in-flight positron annihilation on internal targets of positron storage rings. These data were taken from measurements also performed with annihilation photons but from positron beams external to the accelerators used. The procedures applied in such measurements and based both on processing the multiplicity of detected neutrons and on detecting fission fragments were also analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Sources for Standard-Based Testing

The DHS TC Standards and the consensus ANSI Standards use 252 Cf as the neutron source for performance testing because its energy spectrum is similar to the 235 U and 239 Pu fission sources used in nuclear weapons. An emission rate of 20,000 ± 20% neutrons per second is used for testing of the radiological requirements both in the ANSI standards and the TCS. Determination of the accurate neutron emission rate of the test source is important for maintaining consistency and agreement between testing results obtained at different testing facilities. Several characteristics in the manufacture and the decay of the source need to be understood and accounted for in order to make an accurate measurement of the performance of the neutron detection instrument. Additionally, neutron response characteristics of the particular instrument need to be known and taken into account as well as neutron scattering in the testing environment.

07 ISOTOPE AND RADIATION SOURCES↗

Basics of Neutrons for First Responders

These are slides from a presentation on the basics of neutrons. A few topics covered are: common origins of terrestrial neutron radiation, neutron sources, neutron energy, interactions, detecting neutrons, gammas from neutron interactions, neutron signatures in gamma-ray spectra, neutrons and NaI, neutron fluence to dose (msV), instruments' response to neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report for Grant

This is the final report for this project. The major objectives were to develop full models and standard cells of CMOS silicon photomultipliers (SiPM) for neutron detection applications. Specifically, the research seeks to replace photomultiplier tubes, used in neutron detection applications, with SiPMs containing integrated readout electronics fabricated in standard CMOS processes. The detectors improve on the detection efficiency, readout speed, resolution (sensitivity), and spatial resolution of current systems. In particular, this work involved collaboration with the instrument and detector group at ORNL who build detectors based on discrete commercially available PMTs and SiPMs. The SiPM detectors developed in this work are based on Perimeter Gated Single Photon Avalanche Diodes (PGSPAD). These devices have tunable breakdown voltage which affects other performance characteristics of the detectors. The ability of the detectors to have integrated readout and tune the noise floor and dynamic range in addition to offering a method for non-uniformity compensation in a compact form significantly impacts the imaging research field and includes the nuclear sciences field, circuits and systems field in addition to varied fields such as geography and biology/medicine.

42 ENGINEERING↗

Breast cancer detection using neutron stimulated emission computed tomography: Prominent elements and dose requirements

Neutron stimulated emission computed tomography (NSECT) is being developed to noninvasively determine concentrations of trace elements in biological tissue. Studies have shown prominent differences in the trace element concentration of normal and malignant breast tissue. NSECT has the potential to detect these differences and diagnose malignancy with high accuracy with dose comparable to that of a single mammogram. In this study, NSECT imaging was simulated for normal and malignant human breast tissue samples to determine the significance of individual elements in determining malignancy. The normal and malignant models were designed with different elemental compositions, and each was scanned spectroscopically using a simulated 2.5 MeV neutron beam. The number of incident neutrons was varied from 0.5 million to 10 million neutrons. The resulting gamma spectra were evaluated through receiver operating characteristic (ROC) analysis to determine which trace elements were prominent enough to be considered markers for breast cancer detection. Four elemental isotopes ({sup 133}Cs, {sup 81}Br, {sup 79}Br, and {sup 87}Rb) at five energy levels were shown to be promising features for breast cancer detection with an area under the ROC curve (A{sub Z}) above 0.85. One of these elements - {sup 87}Rb at 1338 keV - achieved perfect classification at 10 million incident neutrons and could be detected with as low as 3 million incident neutrons. Patient dose was calculated for each gamma spectrum obtained and was found to range from between 0.05 and 0.112 mSv depending on the number of neutrons. This simulation demonstrates that NSECT has the potential to noninvasively detect breast cancer through five prominent trace element energy levels, at dose levels comparable to other breast cancer screening techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

Fast neutrons (energies >0.5 MeV) contribute to the radiation exposure of space hardware and astronaut crew, enable greater understanding of planetary atmospheric and surface compositions and allow unique measurements of solar particle acceleration. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement. These measurements are challenging due to size constraints on satellites, particularly newer small satellites. The SOlar Neutron TRACking instrument (SONTRAC) is a small satellite neutron detector that utilizes fine-grained scintillating fiber bundles with 1-mm pitch silicon photomultiplier (SiPM) array readout. Signal processing is accomplished with multichannel ASICs. SONTRAC is able to image fast neutron (between 20-200 MeV) scatters in a compact scalable package. We discuss below the numerous applications of this technology and recent progress on the development and performance characteristics of the prototype instrument.

Georgia A de Nolfo↗

Introduction to Neutron Coincidence Counter Design Based on Boron-10

The Department of Energy Office of Nonproliferation Policy (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is ultimately to design, build and demonstrate a boron-lined proportional tube based alternative system in the configuration of a coincidence counter. This report, providing background information for this project, is the deliverable under Task 1 of the project.

10B↗

Boron-10 Lined Proportional Counter Wall Effects

The Department of Energy Office of Nuclear Safeguards (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a boron-lined proportional tube based system in the configuration of a coincidence counter. This report provides information about how variations in proportional counter radius and gas pressure in a typical coincident counter design might affect the observed signal from boron-lined tubes. A discussion comparing tubes to parallel plate counters is also included.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uranium Neutron Coincidence Collar Model Utilizing 3 He

The Department of Energy Office of Nuclear Safeguards (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a boron-lined proportional tube based alternative system in a configuration typically used for 3 He-based coincidence counter applications. The specific application selected for boron-lined tube replacement in this project was one of the Uranium Neutron Coincidence Collar (UNCL) designs. This report, providing results for model development of a UNCL, is a deliverable under Task 2 of the project. The current UNCL instruments utilize 3 He tubes. As the first step in developing and optimizing a boron-lined proportional counter based version of the UNCL, models of eight different 3 He-based UNCL detectors currently in use were developed and evaluated. A comparison was made between the simulated results and measured efficiencies for those systems with values reported in the literature. The reported experimental measurements for efficiencies and die-away times agree to within 10%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Novel Approach to β-delayed Neutron Spectroscopy Using the Beta-decay Paul Trap

A new approach to β-delayed neutron spectroscopy has been demonstrated that circumvents the many limitations associated with neutron detection by instead inferring the decay branching ratios and energy spectra of the emitted neutrons by studying the nuclear recoil. Using the Beta-decay Paul Trap, fission-product ions were trapped and confined to within a 1-mm{sup 3} volume under vacuum using only electric fields. Results from recent measurements of {sup 137}I{sup +} and plans for development of a dedicated ion trap for future experiments using the intense fission fragment beams from the Californium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne National Laboratory are summarized. The improved nuclear data that can be collected is needed in many fields of basic and applied science such as nuclear energy, nuclear astrophysics, and stockpile stewardship.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗