Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESSURE PULSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Turning Limitations into Opportunities in the Development of the Orion Medical System: Incorporation of mHealth Devices

INTRODUCTION: Selection of medical devices for the Orion medical system is a complex task which is dependent on the current state of terrestrial technology. In this work we review the interplay between NASA requirements, constraints, and opportunities for synergy during the development of the Orion medical system. METHODS: The “plan to treat” list of conditions, and subsequently the medical resource list for the Orion Artemis II lunar flyby mission was completed using semi-quantitative methods. During this process, some medical resources were excluded to comply with mass and volume limits, while other resources applicable to multiple medical requirements were prioritized for inclusion. Choices were also examined considering NASA level of care standards for the Artemis design reference missions. As a means to optimize capabilities in spite of mass and volume constraints, ideas for integration of multiple devices into a single platform were explored, including a ‘hackathon’ challenge which was conducted to generate and evaluate concepts for combining medical devices into a single app-based mobile device (ultrasound, ECG, etc.). RESULTS: The Orion team identified 128 medical conditions that we “plan to treat”, with 139 unique medical resources to address these conditions, including 5 digital diagnostic devices (ECG, otoscope, stethoscope, pulse oximeter, and blood pressure monitor). During selection of these digital devices the team noted that miniaturized medical devices often use mobile device platforms (mHealth), some displaying and transmitting data exclusively via mobile device. Of the 5 initially selected devices, all are capable of mobile connection, one which cannot function without a mobile device (ECG). Furthermore, only one of these devices connects natively to a Windows platform, which is currently the only operating system available on Orion. DISCUSSION: Significant savings in mass and volume as well as training and usability improvements can be achieved by leveraging mHealth technologies. However, the platform presents significant challenges for deployment within the Artemis Program including lack of internet connectivity, incompatible operating systems, and radiation concerns. Each of these drawbacks are surmountable with investment in the supporting vehicle architecture, which may become necessary to support the technology trends seen in commercially available medical devices today. Objective: Learn about the opportunities and challenges of leveraging mHealth devices in the development of medical capabilities for austere environments. Learn about the constraints of the NASA spaceflight environment with regards to digital medical device integration.

Douglas Ebert↗

Detonation propulsion experiments and theory

Test data are presented for the use of a single detonation of explosives in long-cone, short-cone, straight, and firing-plug nozzles to provide propulsion in a simulated Jupiter atmosphere, as well as the ambient gases N, CO2 and He. The long-cone nozzle yielded a progressive increase with ambient pressure for the higher molecular weight gases CO2 and N, while the lower molecular weight He and simulated Jupiter atmosphere showed a specific pulse decrease with increasing ambient pressure. The short-plug nozzle yielded a small specific impulse reduction with increasing ambient pressure, and its results were found to be nearly independent of ambient gas molecular weight. All data gathered are analyzed by using first principles, approximate blast wave theory predictions, and two-dimensional numerical calculations. Rarefaction and oscillatory wave phenomena are found to significantly influence specific impulse.

Back, L. H.↗

Feasibility and Utility of a Cryogenic Integrated RCS

Traditional in-space propulsion systems use storable propellants, such as MMH/NTO, for applications beyond Low Earth Orbit (LEO). Modern advancements in Cryogenic Fluid Management (CFM) technologies opens the door for use of more efficient cryogenic propellants, such as LOX/LCH4 or LOX/LH2, in these long-duration missions beyond LEO. As these Main Propulsion Systems (MPS) transition to cryogenic propellants, a cryogenic solution for Reaction Control Systems (RCS) becomes attractive for several reasons. A mixed-fluid vehicle solution with cryogenic (cool) MPS and storable (warm) RCS complicates thermal management. Additionally, a vehicle with common cryogenic propellant across the MPS and RCS could take advantage of shared hardware such as tanks, thermal management equipment, and pressurization system, reducing mass and development time. The fluid system design proposed in this presentation features shared hardware, leading to the designation of Cryogenic Integrated Reaction Control System (iRCS). The iRCS design stores cryogenic propellant in the low-pressure (10’s psia) MPS tanks, creates steady high-pressure (100’s psia) flow through an electric pump (e-pump), feeds pulse-firing RCS thrusters, and returns any excess flow to the tank through a pressure control device on a recirculation line. This iRCS design is inspired by the automotive fuel-rail, where similar elevated-pressure and pulse-firing requirements are levied. This design has several inherent advantages. Because this design is pump-fed rather than pressure-fed, heavy, high-pressure propellant storage is not required. The RCS propellant can therefore be stored by increasing MPS tank volume. Furthermore, by increasing the pressure of the circulated fluid through an e-pump, the propellant quality moves further into the sub-cooled regime. Sub-cooled liquid is desirable for accurate pressure and flow control at the thruster inlet. Lastly, the iRCS allows the distribution system hardware to maintain cryogenic temperatures by slowly recirculating liquid in a low-energy “Idle Mode”. Altogether, the iRCS concept enables a more efficient cryogenic vehicle design.

Integrated Reaction Control System↗

Feasibility and Utility of a Cryogenic Integrated RCS

Traditional in-space propulsion systems use storable propellants, such as MMH/NTO, for applications beyond Low Earth Orbit (LEO). Modern advancements in Cryogenic Fluid Management (CFM) technologies opens the door for use of more efficient cryogenic propellants, such as LOX/LCH4 or LOX/LH2, in these long-duration missions beyond LEO. As these Main Propulsion Systems (MPS) transition to cryogenic propellants, a cryogenic solution for Reaction Control Systems (RCS) becomes attractive for several reasons. A mixed-fluid vehicle solution with cryogenic (cool) MPS and storable (warm) RCS complicates thermal management. Additionally, a vehicle with common cryogenic propellant across the MPS and RCS could take advantage of shared hardware such as tanks, thermal management equipment, and pressurization system, reducing mass and development time. The fluid system design proposed in this presentation features shared hardware, leading to the designation of Cryogenic Integrated Reaction Control System (iRCS). The iRCS design stores cryogenic propellant in the low-pressure (10’s psia) MPS tanks, creates steady high-pressure (100’s psia) flow through an electric pump (e-pump), feeds pulse-firing RCS thrusters, and returns any excess flow to the tank through a pressure control device on a recirculation line. This iRCS design is inspired by the automotive fuel-rail, where similar elevated-pressure and pulse-firing requirements are levied. This design has several inherent advantages. Because this design is pump-fed rather than pressure-fed, heavy, high-pressure propellant storage is not required. The RCS propellant can therefore be stored by increasing MPS tank volume. Furthermore, by increasing the pressure of the circulated fluid through an e-pump, the propellant quality moves further into the sub-cooled regime. Sub-cooled liquid is desirable for accurate pressure and flow control at the thruster inlet. Lastly, the iRCS allows the distribution system hardware to maintain cryogenic temperatures by slowly recirculating liquid in a low-energy “Idle Mode”. Altogether, the iRCS concept enables a more efficient cryogenic vehicle design.

Integrated↗

Lidar profiling of thermodynamic properties of the atmosphere

Principles and applications of pulsed laser methods for temperature, pressure, density, and humidity measurements in the altitude range 0-100 km are discussed. The differential absorption lidar (DIAL) method requires that at least one of the transmitted laser pulses be carefully tuned onto an absorption feature of the species, whereas Raman backscatter methods do not require tunability. OH and Na fluorescence require tuning of the excitation, and are the most suitable methods for high altitude where the atomic and molecular reemission is relatively unquenched by collisions.

Wilkerson, T. D.↗

Noninvasive measurement of pulsatile intracranial pressure using ultrasound

The present study was designed to validate our noninvasive ultrasonic technique (pulse phase locked loop: PPLL) for measuring intracranial pressure (ICP) waveforms. The technique is based upon detecting skull movements which are known to occur in conjunction with altered intracranial pressure. In bench model studies, PPLL output was highly correlated with changes in the distance between a transducer and a reflecting target (R2 = 0.977). In cadaver studies, transcranial distance was measured while pulsations of ICP (amplitudes of zero to 10 mmHg) were generated by rhythmic injections of saline. Frequency analyses (fast Fourier transformation) clearly demonstrate the correspondence between the PPLL output and ICP pulse cycles. Although theoretically there is a slight possibility that changes in the PPLL output are caused by changes in the ultrasonic velocity of brain tissue, the decreased amplitudes of the PPLL output as the external compression of the head was increased indicates that the PPLL output represents substantial skull movement associated with altered ICP. In conclusion, the ultrasound device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. Our technique makes it possible to analyze ICP waveforms noninvasively and will be helpful for understanding intracranial compliance and cerebrovascular circulation.

NASA Center ARC↗

Gas-Liquid Flows Through Porous Media in Microgravity: The International Space Station Packed Bed Reactor Experiment

Experimental results on pressure drop and flow patterns for gas-liquid flow through packed beds obtained in the International Space Station with two types of packing are presented and analyzed. It is found that the pressure drop depends on the packing wettability in the viscous-capillary (V-C) regime and this dependence is compared with previously published results developed using short duration low-gravity aircraft tests. Within the V-C regime, the capillary contribution is the dominant force contributing to the pressure drop for the wetting case (glass) versus the viscous contribution dominating for the non-wetting case (Teflon). Outside of the V-C regime, it is also found that hysteresis effects that are often strong in normal gravity gas-liquid flows are greatly diminished in microgravity and pressure drop is nearly independent of packing wettability. A flow pattern transition map from bubble to pulse flow is also compared with the earlier aircraft data.

Viscous-capiliary regime↗

Ares I Reaction Control System Propellant Feedline Decontamination Modeling

The objective of the work presented here is to quantify the effects of purge gas temperature, pressure, and mass flow rate on Hydrazine (Hz) decontamination rates of the Ares I Roll Control System and Reaction Control System. A survey of experts in this field revealed the absence of any decontamination rate prediction models. Three basic decontamination methods were identified for analysis and modeling. These include low pressure eduction, high flow rate purge, and pulse purge. For each method, an approach to predict the Hz mass transfer rate, as a function of system pressure, temperature, and purge gas mass flow rate, is developed based on the applicable physics. The models show that low pressure eduction is two orders of magnitude more effective than the high velocity purge, which in turn is two orders of magnitude more effective than the pure diffusion component of pulse purging of deadheads. Eduction subjects the system to low pressure conditions that promote the extraction of Hz vapors. At 120 F, Hz is saturated at approximately 1 psia. At lower pressures and 120 F, Hz will boil, which is an extremely efficient means to remove liquid Hz. The Hz boiling rate is predicted by equating the rate at which energy is added to the saturated liquid Hz through heaters at the tube outer wall with the energy removed from the liquid through evaporation. Boil-off fluxes were predicted by iterating through the range of local pressures with limits set by the minimum allowed pressure of 0.2 psia and maximum allowed wall temperature of 120 F established by the heaters, which gives a saturation pressure of approximately 1.0 psia. Figure 1 shows the resulting boil-off fluxes as a function of local eduction pressure. As depicted in figure 1, the flux is a strong inverse function of eduction pressure, and that minimizing the eduction pressure maximizes the boil-off flux. Also, higher outer wall temperatures lead to higher boil-off fluxes and allow for boil-off over a greater range of eduction pressures.

Pasch, James J.↗

A three-electrode streamer chamber

A three electrode streamer chamber has been designed with basic components consisting of two glass boxes with overall dimensions 1.00 x 500 x 200 cu m filled with neon at 1 atm. Serving as a high voltage pulse source is a nanosecond voltage pulse generator with cutoff discharges at 16 atm nitrogen pressure. The discharges are designed for obtaining an adjustable pulse with an amplitude of 600 kV and a nanosecond pump. To match the chamber electrodes with the oscillator, the electrodes are manufactured in the shape of a three-wire strip line. The cutoff discharger plug-in and the operating instructions are also described here.

Nurgozhin, N. N.↗

Numerical Study of Wave Propagation in a Non-Uniform Flow

The propagation of acoustic waves originating from cylindrical and spherical pulses, in a non-uniform mean flow, and in the presence of a reflecting wall is investigated by Hardin and Pope approach using compact approximation of spatial derivatives. The 2-D and 3-D stagnation flows and a flow around a cylinder are taken as prototypes of real world flows with strong gradients of mean pressure and velocity. The intensity and directivity of acoustic wave patterns appear to be quite different from the benchmark solutions obtained in a static environment for the same geometry. The physical reasons for amplification and weakening of sound are discussed in terms of dynamics of wave profile and redistribution of acoustic energy and its potential and kinetic components. For an acoustic wave in the flow around a cylinder, the observed mean acoustic pressure is approximately doubled (upstream pulse position) and halved (downstream pulse position) in comparison with the sound propagation in static ambient conditions.

Povitsky, Alex↗

Pulse Tube Coolers with an Inertance Tube: Theory, Modeling and Practice

We have studied the advantages to be gained by replacing the conventional orifice of a pulse tube cooler by an inertance tube - a long thin tube that introduces the possibility for additional phase shift between pressure and mass flow in the pulse tube section. The case for the use of an inertance tube is most clearly made with an electrical analogy where the 'inductance' added by the inertance tube allows for optimal power transfer at the cold heat exchanger. Detailed modeling of a pulse tube system with an inertance tube confirms these advantages. Comparison between a laboratory cooler with an orifice and with an inertance tube will be presented and reasons wily it is difficult to realize all the expected gain will be given.

Roach, Pat R.↗

An investigation of the diffraction of an acoustic plane wave by a curved surface of finite impedance

Phenomena associated with long range propagation of sound over irregular topography motivated this work, which was to analyze the diffraction effects which would occur near the tops of hills and ridges. The diffraction of a high frequency plane wave due to its grazing of a two-dimensional curved surface of finite impedance was also studied. Laboratory scale models were constructed and measurements were made of the field on, above, and behind either of two curved surfaces possessing distinctly different impedances; that is, one was soft while the other was hard. The experimental technique consisted of simultaneously measuring the pressure at a reference point and at a field point due to a transient pulse generated by an electric spark. The pressure waveforms were digitized and processed. The ratio of the discrete Fourier transforms of the two waveforms provided an estimate of the insertion loss between them. The results of the measurements were compared with the predictions of a theory which was derived by Pierce using the method of Matched Asymptotic Expansions (MAE). The predictions relied upon the experimental evaluation of the impedance of each surface at grazing angles of incidence. This evaluation was achieved by a fairly standard technique involving empirical models of various generic types of surfaces. An example was shown of the important role that the structural intricacies of a surface play in the determination of an appropriate model. The comparison between the measurements and predictions indicated that the theory gives an excellent description of the field anywhere near a curved surface. Further, with a simple modification, the theory was also shown to give nearly as good of a description of the field surrounding a curved surface even at distances far behind the surface yet near the line of sight.

Kearns, James A.↗

Combustion Noise at Elevated Pressures in a Liquid-Fueled Premixed Combustor

Noise generated in gas turbine combustors can exist in several forms-broadband noise, sharp resonant peaks, and regular or intermittent nonlinear pulsing. In the present study, dynamic pressure measurements were made in several JP-5-fueled combustor configurations, at various mean pressures and temperatures. The fluctuating pressure was measured at mean pressures from 6 to 14 atm and inlet temperatures from 550 K to 850 K. The goal of the present work was to study the effect of changes in mean flow conditions on combustor noise: both broadband noise and sharp tones were considered. In general, the shape of the broadband noise spectrum was consistent from one configuration to another. The shape of the spectrum was influenced by the acoustic filtering of the combustion zone. This filtering ensured the basic consistency of the spectra. In general, the trends in broadband noise observed at low mean pressures were also seen at high mean pressures; that is, the total sound level decreased with both increasing equivalence ratio and increasing inlet temperature. The combustor configurations without a central pilot experienced higher broadband noise levels and were more susceptible to narrow peak resonances than configurations with a central pilot. The sharp peaks were more sensitive to the mean flow than was the broadband noise, and the effects were not always the same. In some situations, increasing the equivalence ratio made the sharp peaks grow, while at other conditions, increasing the equivalence ratio made the sharp peaks shrink. Thus, it was difficult to predict when resonances would occur; however, they were reproducible. Acoustic coupling between the upstream and downstream regions of the combustor may play a role in the sharp-peaked oscillations. Noise was also observed near lean blow out. As with other types of noise, lean blow out noise was affected by the combustion chamber acoustics, which apparently maintains the fluctuations at a uniform frequency. However, the actual conditions when this type of noise was experienced appeared to simply follow the lean blow out limit as it varied with mean temperature and pressure.

Darling, Douglas↗

Nickel hydrogen batteries: An overview

This paper on nickel hydrogen batteries is an overview of the various nickel hydrogen battery design options, technical accomplishments, validation test results and trends. There is more than one nickel hydrogen battery design, each having its advantage for specific applications. The major battery designs are individual pressure vessel (IPV), common pressure vessel (CPV), bipolar and low pressure metal hydride. State-of-the-art (SOA) nickel hydrogen batteries are replacing nickel cadmium batteries in almost all geosynchronous orbit (GEO) applications requiring power above 1 kW. However, for the more severe low earth orbit (LEO) applications (greater than 30,000 cycles), the current cycle life of 4000 to 10,000 cycles at 60 percent DOD should be improved. A LeRC innovative advanced design IPV nickel hydrogen cell led to a breakthrough in cycle life enabling LEO applications at deep depths of discharge (DOD). A trend for some future satellites is to increase the power level to greater than 6 kW. Another trend is to decrease the power to less than 1 kW for small low cost satellites. Hence, the challenge is to reduce battery mass,volume, and cost. A key is to develop a light weight nickel electrode and alternate battery designs. A common pressure vessel (CPV) nickel hydrogen battery is emerging as a viable alternative to the IPV design. It has the advantage of reduced mass, volume and manufacturing costs. A 10 Ah CPV battery has successfully provided power on the relatively short lived Clementine Spacecraft. A bipolar nickel hydrogen battery design has been demonstrated (15,000 LEO cycles, 40 percent DOD). The advantage is also a significant reduction in volume, a modest reduction in mass, and like most bipolar designs, features a high pulse power capability. A low pressure aerospace nickel metal hydride battery cell has been developed and is on the market. It is a prismatic design which has the advantage of a significant reduction in volume and a reduction in manufacturing cost.

Smithrick, John J.↗

A review of nickel hydrogen battery technology

This paper on nickel hydrogen batteries is an overview of the various nickel hydrogen battery design options, technical accomplishments, validation test results and trends. There is more than one nickel hydrogen battery design, each having its advantage for specific applications. The major battery designs are individual pressure vessel (IPV), common pressure vessel (CPV), bipolar and low pressure metal hydride. State-of-the-art (SOA) nickel hydrogen batteries are replacing nickel cadmium batteries in almost all geosynchronous orbit (GEO) applications requiring power above 1 kW. However, for the more severe low earth orbit (LEO) applications (greater than 30,000 cycles), the current cycle life of 4000 to 10,000 cycles at 60 percent DOD should be improved. A NASA Lewis Research Center innovative advanced design IPV nickel hydrogen cell led to a breakthrough in cycle life enabling LEO applications at deep depths of discharge (DOD). A trend for some future satellites is to increase the power level to greater than 6 kW. Another trend is to decrease the power to less than 1 kW for small low cost satellites. Hence, the challenge is to reduce battery mass, volume and cost. A key is to develop a light weight nickel electrode and alternate battery designs. A common pressure vessel (CPV) nickel hydrogen battery is emerging as a viable alternative to the IPV design. It has the advantage of reduced mass, volume and manufacturing costs. A 10 Ah CPV battery has successfully provided power on the relatively short lived Clementine Spacecraft. A bipolar nickel hydrogen battery design has been demonstrated (15,000 LEO cycles, 40 percent DOD). The advantage is also a significant reduction in volume, a modest reduction in mass, and like most bipolar designs, features a high pulse power capability. A low pressure aerospace nickel metal hydride battery cell has been developed and is on the market. It is a prismatic design which has the advantage of a significant reduction in volume and a reduction in manufacturing cost.

Smithrick, John J.↗