Search NASA⌕ Search

SEARCH · Search NASA

Results for “Padding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Effects of dimerization on the photoelectron angular distribution parameters from chiral camphor enantiomers obtained with circularly polarized vacuum-ultraviolet radiation

As an intermediate state of matter between the free monomeric gas phase and the solid state, clusters may exhibit a specific electronic structure and photoionization dynamics that can be unraveled by different types of electron spectroscopies. From mass-selected ion yield scans measured for photoionization of (R)-camphor, the ionization potentials (IPs) of the monomer (8.66{+-}0.01 eV), and of the homochiral dimer ({<=}8.37{+-}0.01 eV) and trimer ({<=}8.30{+-}0.01 eV) were obtained. These spectra, combined with threshold photoelectron spectroscopy and velocity map ion imaging, allow us to show that the camphor monomer and dimer photoionization channels are decoupled, i.e., that the highest occupied molecular orbital (HOMO) of the dimer does not undergo a dissociative ionization process that would lead to a spurious contribution to the monomer ion channel. Therefore mass selection, as achieved in our imaging photoelectron-photoion coincidence experiments, leads to size selection of the nascent monomer or dimer species. Since both the monomer and dimer are chiral, their photoelectron angular distribution (PAD) not only involves the usual {beta} anisotropy parameter but also a chiral asymmetry parameter b{sub 1} that can generate a forward-backward asymmetry in the PAD. This has been investigated using circularly polarized light (CPL) to record the photoelectron circular dichroism (PECD) in the near-threshold vacuum-ultraviolet (VUV) photoionization region. Analysis of size-selected electron images recorded with left- and right-handed CPL shows that over the first 1.5 eV above the HOMO orbital ionization potentials (IPs), the {beta} parameter is not affected by the dimerization process, while the chiral b{sub 1} parameter shows clear differences between the monomer and the dimer, confirming that PECD is a subtle long-range probe of the molecular potential.

74 ATOMIC AND MOLECULAR PHYSICS↗

Strong-field ionization of a heteronuclear diatomic molecule

We theoretically study strong-field ionization of a heteronuclear diatomic molecule, CO, by calculating the photoelectron angular distributions (PADs) and the total ionization rates using linearly and circularly polarized laser fields. We find that, although the PADs of CO generally do not have inversion symmetry, they become more inversion symmetric as the photoelectron energy increases. Heteronuclear features of CO upon ionization are better understood by comparing the results with those of a representative of homonuclear molecules, N{sub 2}, in that, although there are some similarities between CO and N{sub 2} due to the same orbital symmetry, {sigma}{sub g}, there are some differences between them in terms of the ionization suppression and orientation dependence of the total ionization yield. Namely, CO behaves more like an atom in the low-intensity range in a sense that ionization takes place mainly from the neighborhood of the C core, while it behaves more like a double-core molecule in the high-intensity range since ionization takes place from the neighborhood of both C and O cores. This explains why ionization suppression of CO is not seen at the low intensity but it becomes more visible at the high intensity range.

74 ATOMIC AND MOLECULAR PHYSICS↗

Secure Communication via a Recycling of Attenuated Classical Signals

We describe a simple method of interleaving a classical and quantum signal in a secure communication system at a single wavelength. The system transmits data encrypted via a one-time pad on a classical signal and produces a single-photon reflection of the encrypted signal. This attenuated signal can be used to observe eavesdroppers and produce fresh secret bits. The system can be secured against eavesdroppers, detect simple tampering or classical bit errors, produces more secret bits than it consumes, and does not require any entanglement or complex wavelength division multiplexing, thus, making continuous secure two-way communication via one-time pads practical.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray Characterization of a Multichannel Smart-Pixel Array Detector

The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

CMOS ASIC↗

A Misalignment Tolerant Magnetic Coupler Design and Implementation for Wireless Charging of Unmanned Aerial Vehicles (UAVs)

Wireless power transfer technology is getting more attention these days as a part of expanded battery charging infrastructure and network at a wide range of power levels. Charging Unmanned aerial vehicles (UAVs) is one wireless charging application, and charging their batteries can be challenging because they have short flight times and are frequently charged. For wireless charging of UAVs, the misalignment performance of the magnetic coupler pads is critical because landing on a charging pad at a perfectly aligned position is difficult and can be time-consuming. Different coil shapes and system structures have been proposed in the literature to overcome this challenge. A new design with a high misalignment tolerance is needed; therefore, to fill this gap, a wireless power transfer system has been designed for a 250 W UAV battery charging system with a new magnetic coupler design. A 3D model of the proposed design was created, and finite element simulations were performed. To prove the proposed design, the magnetic coupler prototypes were developed, and experimental results are presented herein. The misalignment tolerance of the proposed system was observed for various rotational positions of the secondary coil, from 0° to 360°. The results demonstrate that DC–DC efficiency varies between 80% and 85% within full 360° rotation of the receiver coil. This result enables the proposed system to address the misalignment problem for wireless charging of UAVs.

UAVs↗

AnalyzeThat: A Programmable Shared-Memory System for an Array of Processing-In-Memory Devices

Processing In Memory (PIM), the concept of integrating processing directly with memory, has been attracting a lot of attention since PIM can assist in overcoming the throughput limitation caused by data movement between CPU and memory. The challenge, however, is that it requires the programmers to have a deep understanding of the PIM architecture to maximize the benefits such as data locality and parallel thread execution on multiple PIM devices. In this study, we present AnalyzeThat, a programmable shared-memory system for parallel data processing with PIM devices. Thematic to AnalyzeThat is a rich PIM-Aware Data Structure (PADS), which is an encapsulation that integrally ties together the data, the analysis tasks and the runtime needed to interface with the PIM device array. The PADS abstraction provides (i) a key-value data container that allows programmers to easily store data on multiple PIMs, (ii) a suite of parallel operations with which users can easily implement data analysis applications, and (iii) a runtime, hidden to programmers, which provides the mechanisms needed to overlay both the data and the tasks on the PIM device array in an intelligent fashion, based on PIM-specific information collected from the hardware. We have developed a PIM emulation framework called AnalyzeThat. Our experimental evaluation with representative data analytics applications suggests that the proposed system can significantly reduce the PIM programming effort without losing its technology benefits.

97 MATHEMATICS AND COMPUTING↗

Severe Temperature Impact Study on Ferrite Electromagnetic Shielding for Wireless Electric Vehicle Charging

Wireless charging of an electric vehicle (EV) is an emerging technology that enables noncontact charging, which has advantages in terms of convenience and flexibility. However, the embedded charging pads under and on the ground expose the charging coils, ferrite shielding, and related components to a potentially severe external environment. To study the electromagnetic shielding performance under such extreme temperature conditions, ferrite shielding material's permeability characteristics are tested under temperatures as low as -50°C to as high as 240°C. Referring to the official recorded lowest and highest temperature of the United States, in this paper, it is assumed that the operation temperature ranges from -50°C to 57°C as the coldest winter and hottest summer environment for WPT application. Electromagnetic performance, shielding, and associated stray magnetic emissions are simulated by using three-dimensional (3D) transient simulations to study the impact of low and high temperature on electromagnetic shielding performance. Based on ferrite testing data, from -50°C low temperature to 57°C high temperature, the ferrite's relative permeability ranges from 2550 to 3727. The simulation study indicates that there won't be significant impact on the EM shielding performance for WPT operated under those severe environment temperature conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dark Lock-in Thermography Identifies Solder Bond Failure as the Root Cause of Series Resistance Increase in Fielded Solar Modules

Correlating the electrical performance of photovoltaic modules to the spatially resolved photoluminescence, electroluminescence, and dark lock-in thermography (DLIT) images is an important long-term goal for developing solar cell technology. These images offer highly sophisticated and detailed information about the spatial distribution and (if imaged at successive time intervals) temporal degradation of local series and shunt resistances. There have been extensive studies to correlate these imaging techniques to local characteristics at the cell level. However, it has been difficult to extract and quantify module-level information from the techniques. In this study, we interpret module current-voltage (I-V) measurements along with corresponding DLIT images within a module-scale simulation framework, demonstrating that series resistance degradation of the module I-V characteristics, in this case, can be attributed to solder bond failures. Our simulations highlight how current crowding associated with a failed solder joint (or a section of the solder pad) translates to the characteristic point-like (asymmetric doublet) heating pattern in neighboring solder joints (or the neighboring regions of the solder pad). Overall, the correlation between series resistance and solder joint degradation could inform expedited diagnosis of field degradation of solar modules.

42 ENGINEERING↗

Glass Additive and Subtractive Manufacturing of a Fiber Optic Rotary Encoder for Downhole Pressure Sensing

This article presents a fiber optic rotary encoder-based pressure sensor for downhole applications. The rotary encoder, which is composed of an encoding pad and an all-glass optical fiber sensing head, converts the rotation angles of a pressure transducer to digital codes. The optical fiber only serves as the telemetry channel to directly transmit the data in digital format such that the environmental temperature influence and the long-time drift are minimized. The glass additive and subtractive manufacturing (ASM) techniques are used to embed the multichannel optical fibers into a bulk-fused silica glass substrate. Because the fused silica glass shares a similar material property to the optical fiber (e.g., thermal expansion coefficient), the optical fiber sensing head is well sealed and fixed even at an elevated temperature. The picosecond laser blackening technique is used to fabricate the high reflectivity contrast encoding pad with high accuracy. Here, the proposed pressure sensor was manufactured and experimentally verified to have a signal-to-noise ratio (SNR) of 23 dB and a linear pressure response with a root-mean-square error (RMSE) of 0.37. During the 400-h 250 °C long-term stability test, there was no digital code variation. In addition, a mathematical model to study the relationships between the sensor’s performances and design parameters was established. According to the model, a 12-bit encoder (0.02% pressure sensitivity) can be achieved with a radius of 20 mm.

02 PETROLEUM↗

LeTID-Affected Cells from a Utility-Scale Photovoltaic System Characterized by Deep Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated temperature-induced degradation (LeTID). Samples of one of the affected monocrystalline silicon cells were cored and extracted from the module packaging and encapsulation. One of the cell fragments was processed using a regeneration cycle of applying short-circuit-rated current in forward bias at 85 degrees C for 2 weeks, while the other fragment was kept in its outdoor-degraded LeTID state. Both samples were scribed to form 2-mm diameter isolated areas using a femtosecond-pulse-width laser micromachining system. Both isolated areas contained front grid line segments which were wire bonded to larger contact pads, and the samples were probed in a cryostat linked to a deep-level transient spectroscopy (DLTS) system. Using DLTS, a majority-carrier, hole-trap defect was detected on each sample with an activation energy of 0.42 eV. The LeTID-degraded sample, however, had a larger signal corresponding to a trap density of 1.1x10^13 cm-3, which was about five times larger than the 2.1x10^12 cm-3 trap density of the regenerated sample.

charge carrier lifetime↗

Arrays of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors: Results From a $4\times 4$ Array Prototype

Position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors offer a unique capability for correcting the response nonuniformities caused by crystal defects. This allowed us to achieve high energy resolution, while using typical-grade commercial CZT crystals with relaxed requirements to their quality, thus reducing the overall cost of detectors. Another advantage of the VFG detectors is that they can be integrated into arrays and used in small compact hand-held instruments or large-area gamma cameras that will enhance detection capability for many practical applications, including nonproliferation, medical imaging, and gamma-ray astronomy. Here in this paper, we present the results from testing small array prototypes coupled with front-end application-specified integrated circuit. Each detector in the array is furnished with 5-mm-wide charge-sensing pads placed near the anode. The pads signals are converted into XY coordinates, which combined with the cathode signals (for Z coordinates) provide 3-D position information of all interaction points. The basic array consists of a number of detectors grouped into 2×2 subarrays, each having a common cathode made by connecting together the cathodes of the individual detectors. Lastly, these features can significantly improve the performance of detectors while using typical-grade low-cost CZT crystals to reduce the overall cost of the proposed instrument.

3-D position-sensitive virtual Frisch-grid (VFG) d↗

Interoperability between Three-Phase and Single-Phase WPT Systems

This paper presents an analysis and optimal position alignments of the transmitting and receiving couplers for achieving interoperability between a three-phase and a single-phase inductive wireless power transfer (WPT) system. In addition, single-phase operation modes for the six-switch three-phase inverter are identified for maximal power transfer from the three-phase transmitter pad to the single-phase receiver pad. Simulation results are included to show the power transfer capability between a 50 kW three-phase and an 11 kW double-D or circular single-phase WPT system at various alignment positions of the couplers.

Su, Gui-Jia↗

Chemistry and Formation of the Beilby Layer During Polishing of Fused Silica Glass

The chemical characteristics and the proposed formation mechanisms of the modified surface layer (called the Beilby layer) on polished fused silica glasses are described. Fused silica glass samples were polished using different slurries, polyurethane pads, and at different rotation rates. The concentration profiles of several key contaminants, such as Ce, K, and H, were measured in the near surface layer of the polished samples using Secondary Ion Mass Spectroscopy (SIMS). The penetration of K, originating from KOH used for pH control during polishing, decreased with increase in polishing material removal rate. In contrast, penetration of the Ce and H increased with increase in polishing removal rate. In addition, Ce penetration was largely independent of the other polishing parameters (e.g., particle size distribution and the properties of the polishing pad). The resulting K concentration depth profiles are described using a two-step diffusion process: (1) steady-state moving boundary diffusion (due to material removal during polishing) followed by (2) simple diffusion during ambient postpolishing storage. Using known alkali metal diffusion coefficients in fused silica glass, this diffusion model predicts concentration profiles that are consistent with the measured data at various polishing material removal rates. On the other hand, the observed Ce profiles are inconsistent with diffusion based transport. Rather we propose that Ce penetration is governed by the ratio of Ce–O–Si and Si–O–Si hydrolysis rates; where this ratio increases with interface temperature (which increases with polishing material removal rate) resulting in greater Ce penetration into the Beilby layer. Calculated Ce surface concentrations using this mechanism are in good agreement to the observed change in measured Ce surface concentrations with polishing material removal rate. In conclusion, these new insights into the chemistry of the Beilby layer, combined together with details of the single particle removal function during polishing, are used to develop a more detailed and quantitative picture of the polishing process and the formation of the Beilby layer.

36 MATERIALS SCIENCE↗

Performance and reliability of β-Ga 2 O 3 Schottky barrier diodes at high temperature

Beta-gallium oxide (ß-Ga 2 O 3 ) is an ultrawide bandgap semiconductor that has potential for power electronic applications and devices operating at high temperatures. Particularly important for these applications are its 4.9 eV bandgap, facile electron doping, and the ability to grow ß-Ga 2 O 3 crystals from the melt. In this work, vertical ß-Ga 2 O 3 Schottky barrier diodes were fabricated using Pt Schottky and Ti-based Ohmic contacts and Au contact pads on unintentionally doped n-type, (2¯01)-oriented single crystal substrates. The diode’s temperature-dependent electrical properties up to 400°C were investigated, and the Pt/Ga 2 O 3 Schottky barrier height was determined to be close to 1.2 eV. The degradation of the contacts over multiple cycles up to 400°C was observed, resulting in a significant increase in series resistance of the diodes by 1000× at ambient temperature after they were cycled. According to electron microscopy measurements, this degradation is likely due in part to the migration and oxidation of Ti at the top surface of the Au contact pads. This degradation highlights the need for further research and development to ensure stable Ohmic and Schottky contacts to Ga 2 O 3 at temperatures above 400°C.

36 MATERIALS SCIENCE↗

High-density electrical and optical probes for neural readout and light focusing in deep brain tissue

To advance neuroscience in vivo experiments, it is necessary to probe a high density of neurons in neural networks with single-cell resolution and be able to simultaneously use different techniques, such as electrophysiological recordings and optogenetic intervention, while minimizing brain tissue damage. We first fabricate electrical neural probes with a high density of electrodes and small tip profile (cross section of shank: 47-μm width × 16-μm thickness). Then, with similar substrate and fabrication techniques, we separately fabricate optical neural probes. We finally indicate a fabrication method that may allow integrating the two functionalities into the same device. High-density electrical probes have been fabricated with 64 pads. Interconnections to deliver the signal are 120-nm wide, and the pads are 5 × 25 μm. Separate optical probes with similar shank dimensions with silicon dioxide and silicon nitride ridge single-mode waveguides have also been fabricated. The waveguide core cross section is 250 nm × 160 nm. Light is focused above the waveguide plane in 2.35-μm diameter spots. The actual probes present two output focusing gratings on the shank.

47 OTHER INSTRUMENTATION↗

SU-E-J-162: Quality Assurance Procedures for MR Guided Focused Ultrasound Treatment of Bone Metastasis

Purpose: The purpose of this work is to develop and verify our quality assurance (QA) procedures to ensure the safety and efficacy of MR-guided focused ultrasound (MRgFUS) treatment of bone metastases. Methods: A practical QA program was developed. Monthly and daily QA (DQA) procedures were performed. The major QA items included the checks of the machine hardware, software and patient safety features. Briefly, these checks/tests include: 1) the cooling system reservoir and treatment table; 2) power to the treatment table; 3) the MR coil; 4) the transducer position with MRI; 5) image display on the treatment work station; 6) the effective focal spot in 3 directions using MR thermometry; and 7) all the safety devices including a sonication lamp, and the emergency stop-sonication switches. In order to avoid patient skin burn, it is important to remove gas bubbles in the interfaces between the treatment table and the gel pad, and the gel pad and patients skin during the patient setup. Our QA procedures have been verified and evaluated through patient treatments. Seven patients with scapula, humeral head, sacrum, ilium, pubic ramus and acetabular bone metastases were treated using MRgFUS. Results: Our study showed that all seven patients tolerated the MRgFUS treatment well. No skin toxicity or other complications were observed. The pain score (0–10) using the visual analog scale (VAS) was significantly reduced from 8.0 ± 1.1 before treatment to 4.7 ± 3.0, 3.0 ± 1.5, 3.2 ± 2.8 and 3.4 ± 1.5 at one day, one month, two months and three months after the MRgFUS treatment, respectively. Conclusion: We demonstrated that with the appropriate QA procedures, MRgFUS is a safe, effective and noninvasive treatment modality for palliation of bone metastases.

60 APPLIED LIFE SCIENCES↗

WE-G-17A-01: Improving Tracking Image Spatial Resolution for Onboard MR Image Guided Radiation Therapy Using the WHISKEE Technique

Purpose: To evaluate the feasibility of using the weighted hybrid iterative spiral k-space encoded estimation (WHISKEE) technique to improve spatial resolution of tracking images for onboard MR image guided radiation therapy (MR-IGRT). Methods: MR tracking images of abdomen and pelvis had been acquired from healthy volunteers using the ViewRay onboard MRIGRT system (ViewRay Inc. Oakwood Village, OH) at a spatial resolution of 2.0mm*2.0mm*5.0mm. The tracking MR images were acquired using the TrueFISP sequence. The temporal resolution had to be traded off to 2 frames per second (FPS) to achieve the 2.0mm in-plane spatial resolution. All MR images were imported into the MATLAB software. K-space data were synthesized through the Fourier Transform of the MR images. A mask was created to selected k-space points that corresponded to the under-sampled spiral k-space trajectory with an acceleration (or undersampling) factor of 3. The mask was applied to the fully sampled k-space data to synthesize the undersampled k-space data. The WHISKEE method was applied to the synthesized undersampled k-space data to reconstructed tracking MR images at 6 FPS. As a comparison, the undersampled k-space data were also reconstructed using the zero-padding technique. The reconstructed images were compared to the original image. The relatively reconstruction error was evaluated using the percentage of the norm of the differential image over the norm of the original image. Results: Compared to the zero-padding technique, the WHISKEE method was able to reconstruct MR images with better image quality. It significantly reduced the relative reconstruction error from 39.5% to 3.1% for the pelvis image and from 41.5% to 4.6% for the abdomen image at an acceleration factor of 3. Conclusion: We demonstrated that it was possible to use the WHISKEE method to expedite MR image acquisition for onboard MR-IGRT systems to achieve good spatial and temporal resolutions simultaneously. Y. Hu and O. green receive travel reimbursement from ViewRay. S. Mutic has consulting and research agreements with ViewRay. Q. Zeng, R. Nana, J.L. Patrick, S. Shvartsman and J.F. Dempsey are ViewRay employees.

62 RADIOLOGY AND NUCLEAR MEDICINE↗