Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

RCT Continuing Training: Radiological Emergency Response

Objectives: 1) List the revised initial response and supplemental actions while responding to a major injury inside of a radiological area; 2) List the initial response and supplemental actions while responding to a minor injury inside of a radiological area; 3) List the initial response and supplemental actions for responding to a Continuous Air Monitoring (CAM) alarm; 4) List the initial response and supplemental actions for responding to a radioactive spill; 5) List the initial response and supplemental actions of responding to an Area Radiation Monitor (ARM) alarm; 6) List the initial response and supplemental actions of an Electronic Personal Dosimeter (EPD) dose and dose rate alarm; 7) List the initial response and supplemental actions of responding to a Stationary Contamination Monitor (SCM) alarm; 8) Identify the methods to perform personnel decontamination.

61 RADIATION PROTECTION AND DOSIMETRY↗

MONTE CARLO NEUTRONICS ANALYSIS OF THE SNS STS MONOLITH

Neutronics analysis for the Oak Ridge National Laboratory Spallation Neutron Source second target station monolith conceptual design was performed entirely with the Monte Carlo method. It has been demonstrated that even though the monolith provides ~peta-scale attenuation of the dose rates, Monte Carlo simulations are within reach of computing capabilities of relatively inexpensive Linux clusters. Several monolith configurations achieved or exceeded design requirements and provide basis for the final design.

Remec, Igor↗

Monte Carlo neutronics analysis of the SNS STS monolith - 25684

Neutronics analysis for the Oak Ridge National Laboratory's Spallation Neutron Source second target station monolith conceptual design was performed entirely with the Monte Carlo method. It has been demonstrated that even though the monolith provides ∼peta-scale attenuation of the dose rates, Monte Carlo simulations are within reach of computing capabilities of relatively inexpensive Linux clusters. Several monolith configurations achieved or exceeded design requirements and provide basis for the final design. (authors)

43 PARTICLE ACCELERATORS↗

High-accuracy multi-configuration Dirac–Hartree–Fock calculations of the energy levels and transition properties of Ga-like to Br-like gadolinium ions

Highlights: • A complete and accurate data set of excitation energies, lifetimes, wavelengths and E1, M1, E2, M2 and E3 line strengths, transition rates, and oscillator strengths for Ga-like to Br-like Gd ions is reported. • The Multi-configuration Dirac–Hartree–Fock method is employed. • The effects of core–valence electron correlation from the deep subshells 3d and 3p have been investigated. • The computed excitation energies from the present MCDHF calculations of the VV+CV{sub 3d}+CV{sub 3p} model agree well with the experimental values. The differences are less than ±0.1% for most of the levels. - Abstract: Theoretical calculations of Ga-like to Br-like gadolinium ions were performed by using the fully relativistic multi-configuration Dirac–Hartree–Fock (MCDHF) method. Extensive lists of excitation energies, wavelengths, line and oscillator strengths, and E1, M1, E2, M2, and E3 transition rates are presented. The effects of core–valence electron correlation from the deep subshells 3d and 3p are investigated and the accuracy of the results is confirmed by comparing with available theoretical and experimental data sets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Infrared spectroscopic method for uranium isotopic analysis

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of {sup 235}U and {sup 238}U isotopes in uranium hexafluoride gas samples. Sweeping the quantum cascade laser light source over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm-1 spectral resolution, which allowed for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight % content of {sup 235}U. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287 – 93.7 weight % {sup 235}U), and the results were compared to the International Target Values (ITVS) set forth by the International Atomic Energy Agency (IAEA) for non-destructive and destructive analytical techniques. The method meets or surpasses the IAEA ITVs for non-destructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the {sup 235}U weight % content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA lab if higher-resolution or a certified analysis is needed. (author)

07 ISOTOPE AND RADIATION SOURCES↗

Stability evaluation and mitigation strategies in advanced tokamaks using 3D MHD spectroscopy

Multi-modal, active 3D MHD spectroscopy is applied in high-performance advanced tokamak scenarios to study their stability time evolution, revealing an intriguing dependence on both and . A tailored applied 3D field provides a 3D plasma response to extract the growth rate of the least stable mode. The estimated growth rate finds a decrease in stability when the minimum in the safety factor (q) passes through 2.0 and reveals inherent risks of crossing an additional rational surface at integer q min , even above the usual q = 1 sawtooth condition. Based on this result, the potential scenario in which q min ~ 2 can be safely crossed during a more stable lower β N phase was investigated, and the improved stability of this scenario is confirmed by the estimated growth rate. This shows that 3D MHD spectroscopy can offer insights into strategies for improving stability by identifying the vulnerable aspects of such scenarios. In addition, the method highlights its potential for instability avoidance by enabling early detection of multiple modes, even before magnetic coils can measure them. The measured growth rate by the 3D MHD spectroscopy shows its reliability by exhibiting a correlation with the programmed rises in plasma beta across various high β N and high q min discharges. In addition, this method is successfully applied during rapidly evolving I p ramp-up phases, a key part of the scenario development. By achieving reasonable growth rate measurements at high-performance scenario developments, this technique contributes to the development of advanced diagnostic tools for tokamak scenario stability, which will help identify an effective pathway to stable, high-performance scenarios.

Yang, S. M. [Princeton Plasma Physics Laboratory (↗

Pellet-clad mechanical interaction screening using VERA applied to Watts Bar Unit 1, Cycles 1–3

The Consortium for Advanced Simulation of Light Water Reactors (CASL) aims to provide high-fidelity multiphysics simulations of light water nuclear reactors. To accomplish this, CASL is developing the Virtual Environment for Reactor Applications (VERA), which is a suite of code packages for thermal hydraulics, neutron transport, fuel performance, and coolant chemistry. As VERA continues to grow and expand, there has been an increased focus on incorporating fuel performance analysis methods. One of the primary goals of CASL is to estimate local cladding failure probability through pellet-clad interaction, which consists of both pellet-clad mechanical interaction (PCMI) and stress corrosion cracking. Estimating clad failure is important to preventing release of fission products to the primary system and accurate estimates could prove useful in establishing less conservative power ramp rates or when considering load-follow operations.While this capability is being pursued through several different approaches, the procedure presented in this article focuses on running independent fuel performance calculations with BISON using a file-based one-way coupling based on multicycle output data from high fidelity, pin-resolved coupled neutron transport–thermal hydraulics simulations. This type of approach is consistent with traditional fuel performance analysis methods, which are typically separate from core simulation analyses. A more tightly coupled approach is currently being developed, which is the ultimate target application in CASL.Recent work simulating 12 cycles of Watts Bar Unit 1 with VERA core simulator are capitalized upon, and quarter-core BISON results for parameters of interest to PCMI (maximum centerline fuel temperature, maximum clad hoop stress, and minimum gap size) are presented for Cycles 1–3. In conclusion, based on these results, this capability demonstrates its value and how it could be used as a screening tool for gathering insight into PCMI, singling out limiting rods for further, more detailed analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utah FORGE 2439: A Multi-Component Approach to Characterizing In-Situ Stress

Core-based in-situ stress estimation, Triaxial Ultrasonic Velocity (labTUV) data, and Deformation Rate Analysis (DRA) data for Utah FORGE well 16A(78)-32 using triaxial ultrasonic velocity and deformation rate analysis. Report documenting a multi-component approach to characterizing in-situ stress at the U.S. DOE FORGE EGS site: laboratory, modeling and field measurement. Core-based methods for in-situ stress estimation were applied using samples from 5 intervals within the Utah FORGE 16A(78)-32 well. At three of these locations, Triaxial Ultrasonic Velocity (labTUV) tests were performed, resulting in experimentally-determined relationships between wave velocities and stresses. Non-monotonic increase in the velocity-stress relationships are inferred provide evidence of stress history and are therefore used to estimate in-situ stress magnitudes. Additionally, Deformation Rate Analysis (DRA) tests were run on core plugs from various orientations at each of the 5 sampling locations. These, too, provide evidence of stress history based on stress-strain behavior. A novel Weight of Evidence (WoE) method was developed as a means of synthesizing in-situ stress evidence from these two types of tests. Results indicate the minimum horizontal stress gradient ranges from 0.58 psi/ft to 0.69 psi/ft, with 4 of the 5 values between 0.66 psi/ft and 0.69 psi/ft. The vertical stress gradient ranges from 1.05 psi/ft to 1.12 psi/ft, with 4 of the 5 zones given results between 1.09 psi/ft and 1.12 psi/ft. The maximum horizontal stress gradient ranges from 0.98 psi/ft to 1.34 psi/ft, with 4 of the 5 zones falling between 0.98 psi/ft and 1.24 psi/ft. The stress regime thus appears to be on the edge between normal faulting and strike-slip faulting, potentially flipping back and forth between the two regimes due to variability of rock properties, structures such as faults, and/or thermal anomalies.

15 GEOTHERMAL ENERGY↗

Performance of low-cost monitors to assess household air pollution

Highlights: • We assessed PM{sub 2.5} and CO low-cost monitors in semi-controlled and field studies. • Devices experienced high failure rate and susceptibility to environmental changes. • Low-cost monitors tested may not be ready to replace more established methods. Exposure to household air pollution is a leading cause of morbidity and mortality globally. However, due to the lack of validated low-cost monitors with long-lasting batteries in indoor environments, most epidemiologic studies use self-reported data or short-term household air pollution assessments as proxies of long-term exposure. We evaluated the performance of three low-cost monitors measuring fine particulate matter (PM{sub 2.5}) and carbon monoxide (CO) in a wood-combustion experiment conducted in one household of Spain for 5 days (including the co-location of 2 units of HAPEX and 3 units of TZOA-R for PM{sub 2.5} and 3 units of EL-USB-CO for CO; a total of 40 unit-days). We used Spearman correlation (ρ) and Concordance Correlation Coefficient (CCC) to assess accuracy of low-cost monitors versus equivalent research-grade devices. We also conducted a field study in India for 1 week (including HAPEX in 3 households and EL-USB-CO in 4 households; a total of 49 unit-days). Correlation and agreement at 5-min were moderate-high for one unit of HAPEX (ρ = 0.73 / CCC = 0.59), for one unit of TZOA-R (ρ = 0.89 / CCC = 0.62) and for three units of EL-USB-CO (ρ = 0.82–0.89 / CCC = 0.66–0.91) in Spain, although the failure or malfunction rate among low-cost units was high in both settings (60% of unit-days in Spain and 43% in India). Low-cost monitors tested here are not yet ready to replace more established exposure assessment methods in long-term household air pollution epidemiologic studies. More field validation is needed to assess evolving sensors and monitors with application to health studies.

54 ENVIRONMENTAL SCIENCES↗

Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

Purpose: A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, “FLASH”) potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). Methods and Materials: We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Results: Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. Conclusions: We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scalable in situ non-destructive evaluation of additively manufactured components using process monitoring, sensor fusion, and machine learning

Laser Powder Bed Fusion (L-PBF) Additive Manufacturing (AM) is among the metal 3D printing technologies most broadly adopted by the manufacturing industry. However, the current industry qualification paradigm for critical-application L-PBF parts relies heavily on expensive non-destructive inspection techniques, which significantly limits the use-cases of L-PBF. In situ monitoring of the process promises a less expensive alternative to ex situ testing, but existing sensor technologies and data analysis techniques struggle to detect sub-surface flaws (e.g., porosity and cracking) on production-scale L-PBF printers. In this work, an in situ NDE (INDE) system was engineered to detect subsurface flaws detected in X-Ray Computed Tomography (XCT) directly from process monitoring data. A multilayer, multimodal data input allowed the INDE system to detect numerous subsurface flaws in the size range of 200–1000µm using a novel human-in-the-loop annotation procedure. Furthermore, a framework was established for generating probability-of-detection (POD) and probability-of-false-alarm (PFA) curves compliant with NDE standards by systematically comparing instances of detected subsurface flaws to post-build XCT data. Here, we also introduce for the first time in the AM in situ sensing literature the a 90/95 – the flaw size corresponding to a 90% detection rate on the lower 95% confidence interval of the POD curve. The INDE system successfully demonstrated POD capabilities commensurate with traditional NDE methods. Traditional ML performance metrics were also shown to be inadequate for assessing the ability of the INDE system’s flaw detection performance. It is the hope of the authors that future studies will adopt the POD and PFA approach outlined here to provide better insight into the utility of process monitoring for AM.

36 MATERIALS SCIENCE↗

ARCH: Large-scale knowledge graph via aggregated narrative codified health records analysis

Objective: Electronic health record (EHR) systems contain a wealth of clinical data stored as both codified data and free-text narrative notes (NLP). The complexity of EHR presents challenges in feature representation, information extraction, and uncertainty quantification. Here, to address these challenges, we proposed an efficient Aggregated naRrative Codified Health (ARCH) records analysis to generate a large-scale knowledge graph (KG) for a comprehensive set of EHR codified and narrative features. Methods: Using data from 12.5 million Veterans Affairs patients, ARCH first derives embedding vectors and generates similarities along with associated p-values to measure the strength of relatedness between clinical features with statistical certainty quantification. Next, ARCH performs a sparse embedding regression to remove indirect linkage between features to build a sparse KG. Finally, ARCH was validated on various clinical tasks, including detecting known relationships between entity pairs, predicting drug side effects, disease phenotyping, as well as sub-typing Alzheimer’s disease patients. Results: ARCH produces high-quality clinical embeddings and KG for over 60,000 codified and narrative EHR concepts. The KG and embeddings are visualized in the R-shiny powered web-API.3 ARCH achieved high accuracy in detecting EHR concept relationships, with AUCs of 0.926 (codified) and 0.861 (NLP) for similar EHR concepts, and 0.810 (codified) and 0.843 (NLP) for related pairs. It detected drug side effects with a 0.723 AUC, which improved to 0.826 after fine-tuning. Using both codified and NLP features, the detection power increased significantly. Compared to other methods, ARCH has superior accuracy and enhances weakly supervised phenotyping algorithms’ performance. Notably, it successfully categorized Alzheimer’s patients into two subgroups with varying mortality rates. Conclusion: The proposed ARCH algorithm generates large-scale high-quality semantic representations and knowledge graph for both codified and NLP EHR features, useful for a wide range of predictive modeling tasks.

Electronic health records↗

Identification and quantification of distinct active sites in Hf-Beta zeolites for transfer hydrogenation catalysis

Despite the significant progress made in characterizing different framework heteroatom sites that exist in Lewis acidic zeolites with probe molecule adsorption and spectroscopy, methods to reliably quantify site counts remain indefinite and have been primarily limited to Sn and Ti Lewis acid sites. Here, methods to quantify framework Lewis acidic Hf 4+ sites in zeolite Beta (Hf-Beta) with two Lewis base titrants (pyridine, deuterated acetonitrile) were developed using infrared (IR) spectroscopy. Lewis acid site counts for Hf-Beta zeolites were validated by measuring integrated molar extinction coefficients (IMECs; ε, cm μmol –1 ) on Sn-Beta zeolites using identical Lewis base titrants to benchmark site counts with established literature procedures to quantify Lewis acid sites in Beta zeolites from IR spectra. Highlighting the importance of benchmarking active site counts against well-established experimental protocols, IMECs of CD 3 CN bound to open (ε(Sn; 2316 cm –1 ): 1.80 ± 0.25) and closed (ε(Sn; 2308 cm –1 ): 3.76 ± 0.33) Sn sites were ~1.8x larger than those previously reported while total Lewis acid site counts agreed with those measured by pyridine (ε(Sn; 1451 cm –1 ): 1.58 ± 0.16) on six different Sn-Beta zeolites. IMECs measured for IR peaks reflecting pyridine bound to Lewis acidic Hf sites (ε(Hf; 1448 cm –1 ): 1.54 ± 0.21) and CD 3 CN bound to open (ε(Hf; 2313 cm –1 ): 2.40 ± 0.22) and closed (ε(Hf; 2307 cm –1 ): 3.55 ± 0.41) Hf sites, gave similar counts for the total number of Lewis acidic sites across six Hf-Beta zeolites (Si/Hf = 100–413). Consistent with previous reports with Sn-Beta catalysts where open Sn sites are responsible for catalytic turnover, apparent first and zero-order MPVO rate constants (0.01–1 M cyclohexanone in 2-butanol; per total Hf, 373 K) correlated with the total number of open Hf sites, per total Hf, but not with the total number of closed Hf sites or total Lewis acid site counts. Measured initial MPVO rates (0.1 M cyclohexanone in 2-butanol, per open Hf, 373 K) were ~25x higher on hydrophobic Hf-Beta-F than on hydrophilic Hf-Beta-OH zeolites. Overall, the apparent first-order MPVO rate constants (2-butanol solvent, per open Hf, 373 K) were ~6x higher on Hf-Beta-F than on Hf-Beta-OH zeolites. The characterization methods reported here enable normalization of MPVO turnover rates on Sn- and Hf-Beta zeolites by their number of open sites. Finally, this enables performing quantitative rate comparisons across Lewis acid zeolites of varying active site identity, solvation, and pore topology used in liquid-phase catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of the SSO-ASTRO Margin Guideline on Rates of Re-excision After Lumpectomy for Breast Cancer: A Meta-analysis

Background: One in five patients undergoing initial lumpectomy for invasive breast cancer subsequently undergoes re-excision or mastectomy. A lack of clarity of when to re-excise based on lumpectomy margin width contributes to this high rate of reoperation. We sought to determine the impact of the Society of Surgical Oncology (SSO) and American Society of Radiation Oncologist (ASTRO) margin guideline on reoperation rates after lumpectomy. The guideline recommended omission of routine re-excision in specimens with “no ink on tumor”. Methods: A systematic literature review was performed. For eligible studies, a random-effects model was used for a meta-analysis of lumpectomy re-excision prevalence before and after publication of the SSO-ASTRO margin guideline. Study heterogeneity was measured by the Cochran’s Q test. Results: Five institutional, one population-based, and one national registry study met inclusion requirements. Sample size per study ranged from 237 to 26,102. There was significant interstudy heterogeneity (Q = 19.779; p = 0.003). Pooled re-excision prevalence was 22% (confidence interval [CI] 20–23) before and 14% (CI 12–15) after guideline publication. With the pre-guideline re-excision prevalence used as the reference value, the associated odds ratio for re-excision after the guideline was 0.65 (CI 0.54–0.78; p < 0.0001). Conclusions: The findings of a 35% reduction in the odds of re-excision after the guideline publication and a reduction in re-excision prevalence from 22 to 14% supports the notion that the SSO-ASTRO margin guideline was impactful. These findings are congruent with the projected reductions in re-excision at the time of guideline publication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo Neutronics Analysis of the SNS STS Monolith

The neutronics analysis for the Oak Ridge National Laboratory’s Spallation Neutron Source second target station monolith conceptual design was performed entirely with the Monte Carlo method. It has been demonstrated that even though the monolith provides approximately peta-scale attenuation of the dose rates, Monte Carlo simulations are within reach of computing capabilities of relatively inexpensive Linux clusters. Several monolith configurations achieved or exceeded design requirements and provide basis for the final design.

Remec, Igor↗

Application of machine learning techniques for fast MeV x-ray spectra unfolding from filter stack spectrometer data

Recovery of MeV x-ray spectra from detector signals is difficult because the response matrix inversion is ill-conditioned and current methods are too slow for high-repetition-rate experiments. In this work, we make use of neural networks to unfold MeV x-ray spectra from measurements obtained with a filter stack spectrometer at rates of near 40 Hz. The neural network was trained on synthetic data and tested on both synthetic and experimental data, the latter obtained in two separate experiments performed at the Omega EP laser facility. We show here that this unfolding method has good performance on synthetic data and that it is a promising option for experimental data of up to 40 MeV. The accuracy on experimental data is verified by using a simple forward model to compare against measured values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A computational fluid dynamics simulation framework for ventricular catheter design optimization

OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter’s small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter’s fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter’s design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter’s inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using the standard catheter hole configuration as a baseline. While the standard ventricular catheter design featuring uniform inlet hole diameters and hole spacing has a standard deviation of 14.27% for the inlet flow rates, the optimized design has a standard deviation of 0.30%. CONCLUSIONS This customizable framework, paired with high-performance computing, provides a rapid method of design testing to solve complex flow problems. While a relatively simplified ventricular catheter model was used to demonstrate the framework, the computational approach is applicable to any baseline catheter model, and it is easily adapted to optimize catheters for the unique needs of different patients as well as for other fluid-based medical devices.

Neurosciences & Neurology↗