Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Quantification and visualization of uncertainties in reconstructed penumbral images of implosions at Omega

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference’s uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

Instruments & Instrumentation↗

SCALE Shielding Calculations for Advanced Reactor Accident Scenarios

The study results presented in this paper demonstrate the capabilities of the SCALE computer code for non–light water reactor (non-LWR) radiation source term and shielding calculations in support of the U.S. Nuclear Regulatory Commission non-LWR fuel cycle demonstration project. Representative non-LWR types, including the sodium-cooled fast reactor (SFR), the molten salt reactor (MSR), and the heat pipe microreactor (HPMR), were analyzed to evaluate dose rates associated with postulated accident scenarios (SFR and MSR), reactor operation (MSR and HPMR), and fuel self-protecting characteristics (HPMR). New features were implemented in SCALE depletion codes to better simulate MSR operation.

MSR↗

Phase-controlled direct laser acceleration enabled by longitudinal variation of the laser-driven quasi-static plasma magnetic field

Direct laser acceleration (DLA) enables energy transfer from an ultra-high-intensity laser to plasma electrons and underpins many laser-driven particle and radiation-source concepts. A laser-driven azimuthal plasma magnetic field is a key player in this process: it confines energetic electrons, induces betatron oscillations, and makes possible a resonant interaction between the betatron motion and the laser field. While this betatron resonance can enhance electron energy gain, the gain itself generally drives frequency detuning and promotes largely reversible energy exchange that limits net acceleration. Here we show, using a test-electron model with prescribed fields, that a slow longitudinal increase of the quasi-static plasma magnetic field qualitatively changes DLA by introducing hysteresis in the ratio of the betatron frequency to the laser frequency experienced by the electron, so that this ratio depends on the prior evolution of the electron even at the same energy. This hysteresis enables phase control of the electron-laser energy exchange and suppresses the usual reversibility of DLA, allowing electrons to retain the acquired energy and sustain energy gain without intermittent losses.

direct laser acceleration↗

Extreme radiation emission regime for electron beams in strong focusing ion channels and undulators

A fundamental comparison between a magnetic undulator and an ion channel, or betatron, radiation from relativistic electrons is presented. While conventional theories nominally range from the undulator (𝐾 <1) to the wiggler (𝐾 >1) regime, they are only applicable for sufficiently large Lorentz factors (𝛾 0 ≫𝐾). They therefore do not account for high 𝐾/𝛾 0 cases, for which we show that particle trajectories and radiation characteristics strongly deviate from the linear predictions in both magnetic undulators and ion channels. This problem arises from the fundamental differences between a magnetostatically and electrostatically induced oscillation. A reformulation of both the ion channel betatron wavelength and amplitude, as well as the same parameters in a magnetic undulator, permits us to compare cases with equivalent oscillation period and amplitude in the two different scenarios. The notable differences in spectral features of the two radiation mechanisms can then be addressed via numerical simulations of single particle as well as full beam dynamics. Additionally, we identify and quantify a novel transverse orbit precession effect in ion channels for particles with initial angular momentum relative to the device axis. This effect, which is significant in cases of strong transverse kinetic energy oscillations, alters both the radiation divergence and the beam emittance. In this paper, we present this new theoretical framework and compare its results with numerical simulation applied to realizable experimental tests of such radiation sources.

Frazzitta, Andrea [University of Rome “La Sapienza↗

Neutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators

Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator (OGS) at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239, 338, 583, and 911 keV. 244Cm was identified from emissions of 43, 99, and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.

Lopez, Ricardo [Univ. of Michigan, Ann Arbor, MI (↗

Simple Low-process Radiation Simulation For Unity Game Engine

This is a set of Unity components that use the Unity game engine's transform and collision systems to provide a reasonably representative approximation of any number of unique radiation sources and the collective dose they deliver to a user.

Dunker, Jack [Idaho National Laboratory (INL), Ida↗

Enhancement of harmonic generation by an intense driving laser with high-order waveguide modes in a high-pressure gas-filled hollow waveguide

High-order harmonics have been widely used as reliable tabletop coherent radiation sources recently, but their applications have often been limited by the available pulse energy. Here, we report that by using an overdriven intense laser in a long waveguide with high-pressure gas, phase matching can be achieved in three distinct “regimes”. In the third regime, favorable phase matching is achieved at near-axis positions to enhance harmonic yields. Our results are supported by a full theoretical analysis, and we demonstrate that coupling of the driving laser with the high-order waveguide modes (instead of the fundamental mode used in most prior experiments) is responsible for achieving phase matching. Furthermore, we establish that this phase matching (and harmonic enhancement) is robust, and a scaling relation is derived for the necessary waveguide and gas parameters, allowing our predictions to be tested immediately in any laboratory today.

Li, Baochang [Nanjing University of Science and Te↗

Near-complete extraction of maximum stored energy from large-core fibers using coherent pulse stacking amplification of femtosecond pulses

High field science relies on ultrashort pulse lasers with multi-joule pulse energies for studying light–matter interactions under extreme conditions and for driving particle accelerators and secondary radiation sources of x rays, gamma rays, neutrons, positrons, muons, and protons. Next-generation laser drivers will require a 10 3 -10 4 times increase in pulse repetition rates, producing multi-joule energies at multi-kilowatt average powers to enable practical applications in nuclear engineering, advanced materials, medicine, biology, homeland security, and high-energy physics. Spatially coherently combined femtosecond fiber lasers are recognized as a pathway to these next-generation drivers, with significant practical advantages including high efficiency and the possibility of compact integration. However, chirped pulse amplification in fibers is capable of extracting only a small fraction (usually ~1%) of the maximum stored energy. Here we demonstrate near-complete maximum stored energy extraction with low accumulated nonlinearity from a large-core fiber amplifier using coherent pulse stacking amplification. We have amplified a 81-pulse stacking burst in a 85 µm core chirally coupled core Yb-doped fiber, extracting up to 9.5 mJ (~90% of stored energy) with < 4.5 radians of accumulated nonlinear phase, temporally combined this burst into a single pulse, and achieved 4.2 mJ pulses of 313 fs bandwidth-limited duration after compression. This represents, to our knowledge, the highest energy extracted and compressed into a femtosecond pulse from a single fiber amplifier, enabling approximately two orders of magnitude size reduction of future high-energy coherently spatially combined fiber laser arrays.

47 OTHER INSTRUMENTATION↗

Neutronics Evaluation of the Preliminary Design of the Service Cell Door for the Second Target Station

The service cell door needs to provide sufficient shielding to achieve 0.25 mrem/h dose rates in the adjacent room while remote handling operations of waste materials are going on within the service cell for the Second Target Station (STS). This analysis provides a neutronics evaluation of the preliminary design of the service cell door to evaluate the required thickness and the effect of streaming gaps around the door. As radiation source, we use the decay gamma source of the moderator reflector assembly (MRA) of the STS with a decay time of either two days or six months. As the MRA contains a significant amount of beryllium, photonuclear reactions induce a neutron source, which dictates the required door thickness in certain situations. Four scenarios with different MRA positions and decay times have been analyzed. The required thickness differs drastically depending on the chosen scenario and on the material of the door. The streaming through the gaps around the door is relatively small with high dose rates limited to small sections of the geometry.

43 PARTICLE ACCELERATORS↗

Harnessing Ultra-Intense Long-Wave Infrared Lasers: New Frontiers in Fundamental and Applied Research

This review explores two main topics: the state-of-the-art and emerging capabilities of high-peak-power, ultrafast (picosecond and femtosecond) long-wave infrared (LWIR) laser technology based on CO2 gas laser amplifiers, and the current and advanced scientific applications of this laser class. The discussion is grounded in expertise gained at the Accelerator Test Facility (ATF) of Brookhaven National Laboratory (BNL), a leading center for ultrafast, high-power CO2 laser development and a National User Facility with a strong track record in high-intensity physics experiments. We begin by reviewing the status of 9–10 μm CO2 laser technology and its applications, before exploring potential breakthroughs, including the realization of 100 terawatt femtosecond pulses. These advancements will drive ongoing research in electron and ion acceleration in plasma, along with applications in secondary radiation sources and atmospheric energy transport. Throughout the review, we highlight how wavelength scaling of physical effects enhances the capabilities of ultra-intense lasers in the LWIR spectrum, expanding the frontiers of both fundamental and applied science.

43 PARTICLE ACCELERATORS↗

Charging, aggregation, and electrostatic dispersion of radioactive and nonradioactive particles in the atmosphere

Electrostatic dispersion can significantly impact the microphysical behavior of charged particles and ions until reaching zero space charge. However, although radioactive particles can be strongly charged in air, the influence of electrostatic dispersion has been neglected in understanding their behavior. This study is aimed at investigating the time evolution of the charge and size distributions of radioactive and nonradioactive particles in air and developing simple approaches for applications. With processes involving charging, aggregation, and electrostatic dispersion, a comprehensive population balance model (PBM) has been developed to examine particle charge/size distribution dynamics. It is shown that compared to nonradioactive particles, the charge and size distributions of radioactive particles may evolve differently with time because radioactivity and electrostatic dispersion can significantly affect the charging and aggregation kinetics of the particles. It is found that, after the Fukushima accident, background aerosols in the pathway of radioactive plumes might be highly charged due to ionizing radiation, suggesting that radiation fields may strongly influence in situ measurements of charged atmospheric particles. The comprehensive PBM is simplified, and then the verification and application of the simplified PBMs are discussed. This study provides useful insight into how radioactivity can affect the dynamic behavior of particles in atmospheric systems including radiation sources.

54 ENVIRONMENTAL SCIENCES↗

Densitometer system for liquid hydrogen has high accuracy, fast response

Developmental densitometer system for cryogenic liquids uses two balanced ionization chambers containing xenon gas, with X rays as the radiation source. The X rays are heavily filtered with a lead shield to make the energy spectrum much less dependent on the voltage applied to the X ray tube.

Source record↗

Solar simulation research

Improved measurement techniques for solar simulators, support equipment, and solar cells - pressure arc chamber and vortex stabilized radiation source - radiometry

ARC CHAMBER↗