Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Application and performance of an ML-EM algorithm in NEXT

The goal of the NEXT experiment is the observation of neutrinoless double beta decay in (136)Xe using a gaseous xenon TPC with electroluminescent amplification and specialized photodetector arrays for calorimetry and tracking. The NEXT Collaboration is exploring a number of reconstruction algorithms to exploit the full potential of the detector. This paper describes one of them: the Maximum Likelihood Expectation Maximization (ML-EM) method, a generic iterative algorithm to find maximum-likelihood estimates of parameters that has been applied to solve many different types of complex inverse problems. In particular, we discuss a bi-dimensional version of the method in which the photosensor signals integrated over time are used to reconstruct a transverse projection of the event. First results show that, when applied to detector simulation data, the algorithm achieves nearly optimal energy resolution (better than 0.5% FWHM at the Q value of (136)Xe) for events distributed over the full active volume of the TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-204-10: Evaluation of a Novel Dedicated Breast PET System (Mammi-PET)

Purpose: To evaluate the performance characteristics of a novel dedicated breast PET system (Mammi-PET, Oncovision). The system has 2 detector rings giving axial/transaxial field of view of 8/17 cm. Each ring consists of 12 monolithic LYSO modules coupled to PSPMTs. Methods: Uniformity, sensitivity, energy and spatial resolution were measured according to NEMA standards. Count rate performance was investigated using a source of F-18 (1384uCi) decayed over 5 half-lives. A prototype PET phantom was imaged for 20 min to evaluate image quality, recovery coefficients and partial volume effects. Under an IRB-approved protocol, 11 patients who just underwent whole body PET/CT exams were imaged prone with the breast pendulant at 5–10 minutes/breast. Image quality was assessed with and without scatter/attenuation correction and using different reconstruction algorithms. Results: Integral/differential uniformity were 9.8%/6.0% respectively. System sensitivity was 2.3% on axis, 2.2% and 2.8% at 3.8 cm and 7.8 cm off-axis. Mean energy resolution of all modules was 23.3%. Spatial resolution (FWHM) was 1.82 mm and 2.90 mm on axis and 5.8 cm off axis. Three cylinders (14 mm diameter) in the PET phantom were filled with activity concentration ratios of 4:1, 3:1, and 2:1 relative to the background. Measured cylinder to background ratios were 2.6, 1.8 and 1.5 (without corrections) and 3.6, 2.3 and 1.5 (with attenuation/scatter correction). Five cylinders (14, 10, 6, 4 and 2 mm diameter) each with an activity ratio of 4:1 were measured and showed recovery coefficients of 1, 0.66, 0.45, 0.18 and 0.18 (without corrections), and 1, 0.53, 0.30, 0.13 and 0 (with attenuation/scatter correction). Optimal phantom image quality was obtained with 3D MLEM algorithm, >20 iterations and without attenuation/scatter correction. Conclusion: The MAMMI system demonstrated good performance characteristics. Further work is needed to determine the optimal reconstruction parameters for qualitative and quantitative applications.

60 APPLIED LIFE SCIENCES↗

Artifacts in X-ray Dark-Field Tomography

Grating-based x-ray imaging provides three principle kinds of contrast: absorption, phase, and dark-field. Due to the availability of tomographic reconstruction algorithms for the dark-field contrast, it is now possible to take advantage of quantitative scatter information. However, the published algorithm is based on several assumptions that might be violated in reality. We use numerical simulations in order to identify artifacts in the reconstructions, which is crucial for the interpretation of experimental data.

07 ISOTOPE AND RADIATION SOURCES↗

An iterative approach to non-overdetermined inverse scattering at fixed energy

We present an iterative approximate reconstruction algorithm for non-overdetermined inverse scattering at fixed energy E with incomplete data, where the dimension d≥2. In particular, we obtain rapidly converging approximate reconstructions for this inverse scattering for E→+∞. Bibliography: 38 titles.

97 MATHEMATICS AND COMPUTING↗

Quantitative Monte Carlo-based holmium-166 SPECT reconstruction

Purpose: Quantitative imaging of the radionuclide distribution is of increasing interest for microsphere radioembolization (RE) of liver malignancies, to aid treatment planning and dosimetry. For this purpose, holmium-166 ({sup 166}Ho) microspheres have been developed, which can be visualized with a gamma camera. The objective of this work is to develop and evaluate a new reconstruction method for quantitative {sup 166}Ho SPECT, including Monte Carlo-based modeling of photon contributions from the full energy spectrum.Methods: A fast Monte Carlo (MC) simulator was developed for simulation of {sup 166}Ho projection images and incorporated in a statistical reconstruction algorithm (SPECT-fMC). Photon scatter and attenuation for all photons sampled from the full {sup 166}Ho energy spectrum were modeled during reconstruction by Monte Carlo simulations. The energy- and distance-dependent collimator-detector response was modeled using precalculated convolution kernels. Phantom experiments were performed to quantitatively evaluate image contrast, image noise, count errors, and activity recovery coefficients (ARCs) of SPECT-fMC in comparison with those of an energy window-based method for correction of down-scattered high-energy photons (SPECT-DSW) and a previously presented hybrid method that combines MC simulation of photopeak scatter with energy window-based estimation of down-scattered high-energy contributions (SPECT-ppMC+DSW). Additionally, the impact of SPECT-fMC on whole-body recovered activities (A{sup est}) and estimated radiation absorbed doses was evaluated using clinical SPECT data of six {sup 166}Ho RE patients.Results: At the same noise level, SPECT-fMC images showed substantially higher contrast than SPECT-DSW and SPECT-ppMC+DSW in spheres ≥17 mm in diameter. The count error was reduced from 29% (SPECT-DSW) and 25% (SPECT-ppMC+DSW) to 12% (SPECT-fMC). ARCs in five spherical volumes of 1.96–106.21 ml were improved from 32%–63% (SPECT-DSW) and 50%–80% (SPECT-ppMC+DSW) to 76%–103% (SPECT-fMC). Furthermore, SPECT-fMC recovered whole-body activities were most accurate (A{sup est}= 1.06 × A − 5.90 MBq, R{sup 2}= 0.97) and SPECT-fMC tumor absorbed doses were significantly higher than with SPECT-DSW (p = 0.031) and SPECT-ppMC+DSW (p = 0.031).Conclusions: The quantitative accuracy of {sup 166}Ho SPECT is improved by Monte Carlo-based modeling of the image degrading factors. Consequently, the proposed reconstruction method enables accurate estimation of the radiation absorbed dose in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Resolving the phase of Fano resonance wave packets with photoelectron frequency-resolved optical gating

The creation of structured electronic wave packets (EWPs) energetically close to Fano resonances has been achieved with ultrafast extreme ultraviolet coherent light sources. However, direct real-time observations of EWP evolution and full reconstructions of the quantum properties of EWPs, including both amplitude and phase, are lacking. Here we introduce and demonstrate a comprehensive approach for the direct measurement and complete characterization of structured EWPs created within a prototypical Fano resonance. Because of its analogy with frequency-resolved optical gating (FROG), we named the method photoelectron FROG. The correlated EWP is initiated by a carefully engineered extreme UV pump pulse. A weak near-infrared laser field, serving as a probe pulse, samples the evolution of the EWPs in the time domain, as well as in the frequency domain. The amplitude and phase of the EWPs are obtained via a time-dependent reconstruction algorithm based on a short-time Fourier transformation. Given the excellent agreement between our experimental results and time-dependent reconstructions, we expect this method to be broadly applicable to the study of ultrafast processes, especially electronic ones, in complex systems, as well as the coherent control of such systems on their fundamental timescales.

quantum optics↗

Towards Full Field-of-View Fourier Ptychography for Extreme Ultraviolet Microscope

We evaluate various Fourier ptychographic microscopy (FPM) reconstruction algorithms using both simulated and experimental data acquired from an Extreme Ultraviolet (EUV, 13.5 nm wavelength) microscope. We specifically focus on the algorithms' ability to robustly address field-dependent aberrations, which enables increased spatial resolution and quantitative phase imaging across an expanded field of view. We systematically compare the algorithms' performance under aberrations for a single zoneplate imaging system, utilizing Fourier Ring Correlation (FRC) as a systematic metric for assessing reconstruction quality. Furthermore, we explore the impact of systematic errors on the reconstruction of experimental data, aiming to increase the effective field of view by 25-fold, from the nominal 5x5 um2 diffraction-limited area. Additionally, our evaluation incorporates innovative FPM-adjacent methodologies, including the Angular Ptychographic Imaging with Closed-form method (APIC), for reconstructing EUV images.

Gu, Chaoying↗

Fidelity of a Time-Resolved Imaging Diagnostic for Electron Beam Profiles

An optical tomographic diagnostic instrument has been fielded at the Dual-Axis Radiographic Hydrodynamic Test Facility at Los Alamos National Laboratory. Four optical lines of sight create projections of an image of an electron beam on a Cerenkov target, which are relayed via optical fiber to streak cameras. From these projections, a reconstruction algorithm creates time histories of the beam’s cross section. The instrument was fielded during and after facility commissioning, and tomographic reconstructions reported beam parameters. Results from reconstructions and analysis are noted.

Dual-Axis Radiographic Hydrodynamic Test, DARHT, e↗

SU-E-J-104: Single Photon Image From PET with Insertable SPECT Collimator for Boron Neutron Capture Therapy: A Feasibility Study

Purpose: The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one positron emission tomography (PET) module with an insertable collimator for brain tumor treatment during the BNCT. Methods: Data from the PET module, neutron source, and collimator was entered in the Monte Carlo n-particle extended (MCNPX) source code. The coincidence events were first compiled on the PET detector, and then, the events of the prompt gamma ray were collected after neutron emission by using a single photon emission computed tomography (SPECT) collimator on the PET. The obtaining of full width at half maximum (FWHM) values from the energy spectrum was performed to collect effective events for reconstructed image. In order to evaluate the images easily, five boron regions in a brain phantom were used. The image profiles were extracted from the region of interest (ROI) of a phantom. The image was reconstructed using the ordered subsets expectation maximization (OSEM) reconstruction algorithm. The image profiles and the receiver operating characteristic (ROC) curve were compiled for quantitative analysis from the two kinds of reconstructed image. Results: The prompt gamma ray energy peak of 478 keV appeared in the energy spectrum with a FWHM of 41 keV (6.4%). On the basis of the ROC curve in Region A to Region E, the differences in the area under the curve (AUC) of the PET and SPECT images were found to be 10.2%, 11.7%, 8.2% (center, Region C), 12.6%, and 10.5%, respectively. Conclusion: We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.2009 00420) and the Radiation Technology R and D program (Grant No.2013M2A2A7043498), Republic of Korea.

07 ISOTOPE AND RADIATION SOURCES↗

CRADA: Data Acquisition and Tomographic Software Development

Dr. Raymond R. Raylman, Professor and Vice Chair for Research, Radiology Department at WVU was the Principal Investigator for the project. The Jefferson Lab partner on this project was the Radiation Detector and Imaging Group in the Physics Division, led by Dr. Drew Weisenberger who was the coordinator of the project execution and the chief contact with WVU. The responsibility of Jefferson Lab was to facilitate optimization of data acquisition software, conversion of JLab Fortran iterative positron emission mammography computer code to C++ and to act as a computer code repository. During the two year project interactions and exchange of information was directed by Dr. Raylman and Dr. Wesienberger. WVU provided the expertise that allowed JLab to continue development of the current JLab data acquisition software referred to as JDAQ. JDAQ is a highly flexible Java language based data acquisition tool that helps to minimize software induced dead-time while maintaining the highest possible data rates from a JLab built FPGA based analog-to-digital convertor (ADC). JDAQ interfaces directly with the FPGA based multi-channel ADCs. Using JDAQ it is possible process data from a number of different detector types such as the PET systems at WVU. Because of the inherent flexibility of our processing software, we are also able adjust detector readout parameters during operation to provide the best possible data presentation and calibration parameters. To accommodate the high rate nature of PET detector systems JDAQ was designed to be scalable across an Ethernet network as well as for multi-cpu computer systems, and it also has the capability to synchronize many ADCs connected to multiple computers. During the project WVU will provided iterative reconstruction algorithm expertise and Fortran programming assistance to facilitate the conversion to C++ of a JLab developed Fortran positron emission mammography (PEM) reconstruction code. Also WVU provided acceptance testing of the new C++ based PEM reconstruction code. The PEM code is a maximization (MLEM) image reconstruction program that created images from the list-mode data acquired from the PET system.

97 MATHEMATICS AND COMPUTING↗

Pushing the Limits of High-speed X-ray Tomography to See the Unknown

First-of-their kind datasets from a high-speed X-ray tomography system were collected, and a novel numerical effort utilizing temporal information to reduce measurement uncertainty was shown. The experimental campaign used three high-speed X-ray imaging systems to collect data at 100 kHz of a scene containing high-velocity objects. The scene was a group of known objects propelled by a 12-gauge shotgun shell reaching speeds of hundreds of meters per second. These data represent a known volume where the individual components are known, with experimental uncertainties that can be used for reconstruction algorithm validation. The numerical effort used synthetic volumes in MATLAB to produce projections along known lines of sight to perform tomographic reconstructions. These projections and reconstructions were performed on a single object at two orientations, representing two timesteps, to increase the reconstruction accuracy.

36 MATERIALS SCIENCE↗

WE-AB-207A-08: BEST IN PHYSICS (IMAGING): Advanced Scatter Correction and Iterative Reconstruction for Improved Cone-Beam CT Imaging On the TrueBeam Radiotherapy Machine

Purpose: To improve CBCT image quality for image-guided radiotherapy by applying advanced reconstruction algorithms to overcome scatter, noise, and artifact limitations Methods: CBCT is used extensively for patient setup in radiotherapy. However, image quality generally falls short of diagnostic CT, limiting soft-tissue based positioning and potential applications such as adaptive radiotherapy. The conventional TrueBeam CBCT reconstructor uses a basic scatter correction and FDK reconstruction, resulting in residual scatter artifacts, suboptimal image noise characteristics, and other artifacts like cone-beam artifacts. We have developed an advanced scatter correction that uses a finite-element solver (AcurosCTS) to model the behavior of photons as they pass (and scatter) through the object. Furthermore, iterative reconstruction is applied to the scatter-corrected projections, enforcing data consistency with statistical weighting and applying an edge-preserving image regularizer to reduce image noise. The combined algorithms have been implemented on a GPU. CBCT projections from clinically operating TrueBeam systems have been used to compare image quality between the conventional and improved reconstruction methods. Planning CT images of the same patients have also been compared. Results: The advanced scatter correction removes shading and inhomogeneity artifacts, reducing the scatter artifact from 99.5 HU to 13.7 HU in a typical pelvis case. Iterative reconstruction provides further benefit by reducing image noise and eliminating streak artifacts, thereby improving soft-tissue visualization. In a clinical head and pelvis CBCT, the noise was reduced by 43% and 48%, respectively, with no change in spatial resolution (assessed visually). Additional benefits include reduction of cone-beam artifacts and reduction of metal artifacts due to intrinsic downweighting of corrupted rays. Conclusion: The combination of an advanced scatter correction with iterative reconstruction substantially improves CBCT image quality. It is anticipated that clinically acceptable reconstruction times will result from a multi-GPU implementation (the algorithms are under active development and not yet commercially available). All authors are employees of and (may) own stock of Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Model-based CT performance assessment and optimization for iodinated and noniodinated imaging tasks as a function of kVp and body size

Purpose: The goal of this study was to assess the comparative performance of iterative reconstruction in space (IRIS) and filtered back projection (FBP) reconstruction algorithms in terms of image quality and dose across kVps and phantom sizes. Methods: The ACR CT phantom (model 464) was supplemented with the addition of an iodinated spherical capsule (1.5 mm diameter, 3.4 mg iodine per ml) to simulate the contrast filled structures and with an additional circular attachment consisting of an array of 500 um brass beads for spatial resolution measurements. A larger sized phantom was also created by wrapping the original phantom with additional tissue equivalent material of 4 cm thickness. The phantoms were imaged on a 64 detector array multidetector computed tomography scanner (Somatom Definition, Siemens, Germany) using clinically applicable protocols (0.5 s rotation time; 80, 100, 120, and 140 kVp; 64 to 640 mA; 220 to 250 mm field of view). Images were reconstructed using the FBP and the IRIS algorithms. Combining measurements of image noise and spatial resolution with a task function, a figure of merit (FOM) for image quality was generated taking into account the type of visualization required from the image for the detection of either large or small image features with and without iodine content. The FOM was further reported in terms of area under the receiver operating characteristic (ROC) curve (A{sub Z}) to predict the comparative diagnostic performance of the two algorithms at different dose levels. Results: For a given dose level, the predicted A{sub Z} for IRIS consistently outperformed that of FBP. At comparative A{sub Z}, depending on protocol and task, the dose requirement for the optimal technique (optimized kVp with IRIS) was 2-3 times lower than that for standard technique (120 kVp with FBP). The potential for dose reduction was found to be higher when performing small feature detection tasks in comparison to larger feature detection tasks. The optimal kVp was from 80 to 100 kVp for the small phantom, 100 to 120 kVp for the larger phantom. Conclusions: Overall, greater dose reduction may be achieved with IRIS compared to FBP, with enhanced advantage at thinner slice reconstructions. The results highlight how IRIS may offer a superior balance between image quality and dose across a range of imaging tasks, thus enabling dose reduction at constant quality or image quality improvement at constant dose. The prediction of the investigation can be used toward effective design of subsequent clinical studies.

60 APPLIED LIFE SCIENCES↗

Inverse transport calculations in optical imaging with subspace optimization algorithms

Inverse boundary value problems for the radiative transport equation play an important role in optics-based medical imaging techniques such as diffuse optical tomography (DOT) and fluorescence optical tomography (FOT). Despite the rapid progress in the mathematical theory and numerical computation of these inverse problems in recent years, developing robust and efficient reconstruction algorithms remains a challenging task and an active research topic. We propose here a robust reconstruction method that is based on subspace minimization techniques. The method splits the unknown transport solution (or a functional of it) into low-frequency and high-frequency components, and uses singular value decomposition to analytically recover part of low-frequency information. Minimization is then applied to recover part of the high-frequency components of the unknowns. We present some numerical simulations with synthetic data to demonstrate the performance of the proposed algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray phase laminography with a grating interferometer using iterative reconstruction

X-ray phase computed laminography is performed using a Talbot interferometer and synchrotron radiation. An iterative reconstruction algorithm which includes prior information about limited support, range of values and sparsity of the imaged object has been developped. It allows the reconstruction of objects with an improved resolution of the unsampled frequencies, compared to the classical filtered backprojection. The imaging method, demonstrated for a nylon mesh sample and a leaf sample, shows promising results for the imaging of flat, laterally extended objects made of low absorbing elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose reconstruction for real-time patient-specific dose estimation in CT

Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

60 APPLIED LIFE SCIENCES↗

Compressive sensing super resolution from multiple observations with application to passive millimeter wave images

In this study we propose a novel framework to obtain high resolution images from compressed sensing imaging systems capturing multiple low resolution images of the same scene. The proposed approach of Compressed Sensing Super Resolution (CSSR), combines existing compressed sensing reconstruction algorithms with a low-resolution to high-resolution approach based on the use of a super Gaussian regularization term. The reconstruction alternates between compressed sensing reconstruction and super resolution reconstruction, including registration parameter estimation. The image estimation subproblem is solved using majorization-minimization while the compressed sensing reconstruction becomes an l 1 -minimization subject to a quadratic constraint. The performed experiments on grayscale and synthetically compressed real millimeter wave images, demonstrate the capability of the proposed framework to provide very good quality super resolved images from multiple low resolution compressed acquisitions.

42 ENGINEERING↗

A Novel 24 GHz One-Shot, Rapid and Portable Microwave Imaging System

Development of microwave and millimeter wave imaging systems has received significant attention in the past decade. Signals at these frequencies penetrate inside of dielectric materials and have relatively small wavelengths. Thus. imaging systems at these frequencies can produce images of the dielectric and geometrical distributions of objects. Although there are many different approaches for imaging at these frequencies. they each have their respective advantageous and limiting features (hardware. reconstruction algorithms). One method involves electronically scanning a given spatial domain while recording the coherent scattered field distribution from an object. Consequently. different reconstruction or imaging techniques may be used to produce an image (dielectric distribution and geometrical features) of the object. The ability to perform this accurate~v and fast can lead to the development of a rapid imaging system that can be used in the same manner as a video camera. This paper describes the design of such a system. operating at 2-1 GHz. using modulated scatterer technique applied to 30 resonant slots in a prescribed measurement domain.

Ghasr, M. T.↗