Application of a pore-scale reactive transport model to a natural analog for reaction-induced pore alterations.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Measurement of displacement time and length scale dependent dynamics by pulsed gradient spin echo nuclear magnetic resonance in porous media directly provides the preasymptotic hydrodynamic dispersion coefficient. This allows for comparison with nonequilibrium statistical mechanics models of hydrodynamics dispersion in porous media. Preasymptotic dispersion data and models provide characterization of porous media structure length scales relevant to transport and are related to the permeability and sample heterogeneity.
The flagellin epitope flg22, a pathogen-associated molecular pattern (PAMP), binds to the receptor-like kinase FLAGELLIN SENSING2 (FLS2), and triggers Ca 2+ influx across the plasma membrane (PM). The flg22-induced increases in cytosolic Ca 2+ concentration ([Ca 2+ ]i) (FICA) play a crucial role in plant innate immunity. It's well established that the receptor FLS2 and reactive oxygen species (ROS) burst undergo sensitivity adaptation after flg22 stimulation, referred to as desensitization and resensitization, to prevent over responses to pathogens. However, whether FICA also mount adaptation mechanisms to ensure appropriate and efficient responses against pathogens remains poorly understood. Here, we analysed systematically [Ca 2+ ]i increases upon two successive flg22 treatments, recorded and characterized rapid desensitization but slow resensitization of FICA in Arabidopsis thaliana. Pharmacological analyses showed that the rapid desensitization might be synergistically regulated by ligand-induced FLS2 endocytosis as well as the PM depolarization. The resensitization of FICA might require de novo FLS2 protein synthesis. FICA resensitization appeared significantly slower than FLS2 protein recovery, suggesting additional regulatory mechanisms of other components, such as flg22-related Ca 2+ permeable channels. Taken together, we have carefully defined the FICA sensitivity adaptation, which will facilitate further molecular and genetic dissection of the Ca 2+ -mediated adaptive mechanisms in PAMP-triggered immunity.
Unlike many other clastic rocks, relating velocity and permeability to porosity for micrite-bearing carbonate rocks has been largely unsuccessful. Recent studies have shown that additional parameters, most notably the distribution and/or proportion of micrite, can be used to parameterize the velocity and permeability behavior. However, there is currently no scale-consistent, 3D methodology for differentiating macroporosity and microporosity from the total porosity measured on bench-top laboratory equipment. Previous studies estimated microporosity and micrite content by combining total porosity measurements conducted on whole 50 mm cores with measurements of phase volumes on 1 mm digital rocks (i.e., scale-inconsistent). As a step forward from those, we imaged dual-porosity carbonate rocks using X-ray microcomputed tomography and then leveraged a recently developed, optimization-based technique, called data-constrained modeling, to map the macroporosity and microporosity distribution of our samples. We evaluate the volumetric proportions of macropores, micropores, and coarse-grained calcite as a function of micrite content — with their respective uncertainties — all measured on the same digital rock and with the same method. Finally, we determine how measurements of the volumetric phase proportions could be extended using standard effective medium models to predict reservoir physical properties. Here, the sensitivity of these models to the proportion of micrite and microporosity within the micrite is evidence that the nonuniqueness among permeability, velocity, and porosity that is commonly observed of micrite-bearing carbonate rocks can be explained by a variation of micrite content and microporosity at a similar porosity.
The Cambro-Ordovician strata of the Illinois and Michigan Basins underlie most of the states of Illinois, Indiana, Kentucky, and Michigan. This interval also extends through much of the Midwest of the United States and, for some areas, may be the only available target for geological sequestration of CO 2 . We evaluated the Cambro-Ordovician strata above the basal Mt. Simon Sandstone reservoir for sequestration potential. The two targets were the Cambrian carbonate intervals in the Knox and the Ordovician St. Peter Sandstone. The evaluation of these two formations was accomplished using wireline data, core data, pressure data, and seismic data from the USDOE-funded Illinois Basin Decatur Project being conducted by the Midwest Geological Sequestration Consortium in Macon County, Illinois. Interpretations were completed using log analysis software, a reservoir flow simulator, and a finite element solver that determines rock stress and strain changes resulting from the pressure increase associated with CO 2 injection. Results of this research suggest that both the St. Peter Sandstone and the Potosi Dolomite (a formation of the Knox) reservoirs may be capable of storing up to 2 million tonnes of CO 2 per year for a 20-year period. Reservoir simulation results for the St. Peter indicate good injectivity and a relatively small CO 2 plume. While a single St. Peter well is not likely to achieve the targeted injection rate of 2 million tonnes/year, results of this study indicate that development with three or four appropriately spaced wells may be sufficient. Reservoir simulation of the Potosi suggest that much of the CO 2 flows into and through relatively thin, high permeability intervals, resulting in a large plume diameter compared with the St. Peter.
We adopt the standard field matching technique to solve the general electromagnetic problem consisting of two parallel layers with arbitrary complex relative permittivity and permeability. With parameters of the NSLS-II ceramic chambers, we calculate the power dissipated on the metallic coating and compare the result with the power lost by the beam and with the results of [4].
DECOVALEX Task G deals with fracture mechanics at several scales using a combined approach of experimental work, related model development, benchmarking and experimental analysis. Fig. 0.1 provides a graphical abstract for Task G. The experimental basis for the related mechanical (M), hydro-mechanical (HM), and thermo-mechanical (TM) processes comes from the rock mechanics laboratories of Universities of Freiberg (TUBAF) and Edinburgh, as well as the Korea Institute of Civil Engineering and Building Technology (KICT). The experimental work in the rock laboratories is closely linked to the underground research laboratories (URLs) Reiche Zeche (Germany), KURT (Korea), and Mont Terri (Switzerland). The scientific key questions are related to fracture permeability evolution under THM conditions, anisotropy effects on fracturing processes, and thermal fracture slip, which are being addressed in specific steps of the task. A large variety of numerical methods have been developed and applied for experimental analysis, ranging from continuum to discontinuum approaches. A detailed comparison of mechanical and hydro-mechanical processes is given in the section 3 via the benchmarking exercises. As a result of DECOVALEX-2023 Task G we further improved our understanding and predictability of fracturing processes under THM conditions. This was based on robust numerical simulation methods and in-depth experimental analysis.
For near-surface contaminant characterization, the accurate prediction of hydrogeological parameters in anisotropic and heterogeneous environments has been a challenge since the last decades. However, recent advances in near-surface geophysics have facilitated the use of geophysical data for hydrogeological characterization in the last few years. A pseudo 3-D high resolution P-wave shallow seismic reflection survey was performed at the P Reactor Area, Savannah River Site, South Carolina in order to delineate and predict migration pathways of a large contaminant plume including trichloroethylene. This contaminant plume originates from the northwest section of the reactor facility that is located within the Upper Atlantic Coastal Plain. The data were collected with 40 Hz geophones, an accelerated weight-drop as seismic source and 1 m receiver spacing with near- and far-offsets of 0.5 and 119.5 m, respectively. In such areas with near-surface contaminants, a detailed subsurface characterization of the vadose zone hydraulic parameters is very important. Indeed, an inexpensive method of deriving such parameters by the use of seismic reflection surveys is beneficial, and our approach uses the relationship between seismic velocity and hydrogeological parameters together with empirical observations relating porosity to permeability and hydraulic conductivity. Shear wave velocity ( V s ) profiles were estimated from surface wave dispersion analysis of the seismic reflection data and were subsequently used to derive hydraulic parameters such as porosity, permeability, and hydraulic conductivity. Additional geophysical data including core samples, vertical seismic profiling, surface electrical resistivity tomography, natural gamma and electrical resistivity logs allowed for a robust assessment of the validity and geological significance of the estimated V s and hydrogeological models. The results demonstrate the usefulness of this approach for the upper 15 m of shallow unconsolidated sediments even though the survey design parameters were not optimal for surface wave analysis due to the higher than desired frequency geophones.
A feasibility study was made for a salt gradient solar pond power plant in or near the Salton Sea of California. The conclusions support continuance 5-MWe proof-of-concept experiment, and ultimate construction by an electric utility company of a 600-MWe plant. The Solar Pond concept would be an environmental benefit to the Salton Sea by reversing the increasing salinity trend. The greatest cost drivers are the lake dike construction and pond sealing. Problems to be resolved include method of brine production from Salton Sea water for the first unit (which requires evaporation pond area and time), the high turbidity and color content of the Salton Sea water (which requires pretreatment), and other questions related to pond permeability, bio-activity and soil/brine chemical reactions. All technical and environmental problems appear solvable and/or manageable if care is taken in mitigating impacts.
Numerical models of Martian hydrothermal systems demonstrate that systems associated with magmatic intrusions greater than several hundred cubic kilometers can provide sufficient groundwater outflow to form the observed fluvial valleys, if subsurface permeability exceeds about 1.0 darcy. Groundwater outflow increases with increasing intrusion volume and subsurface permeability and is relatively insensitive to intrusion depth and subsurface porosity within the range considered here. Hydrothermally-derived fluids can melt through 1 to 2 km thick ice-rich permafrost layers in several thousand years. Hydrothermal systems thus provide a viable alternative to rainfall for providing surface water for valley formation. This mechanism can form fluvial valleys not only during the postulated early warm, wet climatic epoch, but also during more recent epochs when atmospheric conditions did not favor atmospheric cycling of water. The clustered distribution of the valley networks on a given geologic surface or terrain unit of Mars may also be more compatible with localized, hydrothermally-driven groundwater outflow than regional rainfall. Hydrothermal centers on Mars may have provided appropriate environments for the initiation of life or final oases for the long-term persistence of life.
The leading edge slat of a high-lift system is one of the main contributors to airframe noise during approach. In a previous experimental study, we assessed the performance of an impermeable slat gap filler as a passive flow control device to reduce the slat noise associated with a two-dimensional, three-element high-lift airfoil. The present paper, the first of two parts,represents a follow-on investigation to assess the relative efficacy of permeable gap fillers thatallow successively higher amounts of flow to pass through the gap. To evaluate the influence of this passive flow control device on the acoustics generated by the unsteady flow near the slat, experiments are conducted in an anechoic wind tunnel by mounting a gap filler to the slat element of the two-dimensional 30P30N high-lift configuration. Measurements are performed at a single geometric angle of attack (𝛼𝑘=8◦) and three different flow speeds that correspond to Reynolds numbers of𝑅𝑒𝑐=1.2𝑒6,1.5𝑒6, and1.71𝑒6, respectively. Steady surface pressure measurements are used to gauge the influence of the permeable gap filler treatments on the overall lift. The effect of each treatment on the radiated noise is analyzed via acoustic array measurements, followed by delay-and-sum beamforming to locate the slat noise sources and to provide the integrated acoustic spectra. The porous gap fillers are found to eliminate the narrowband peaks in the acoustic spectra and, also, to yield a 10 dB reduction in the broadband noise in comparison with the baseline case with no gap filler. The porous gap filler with thelowest permeability acts similar to the impermeable gap filler examined previously. However, the aerodynamics and noise reduction both degrade with increasing permeability. An accompanying abstract describes the particle image velocimetry measurements of the flowfield within the slat cove and on either side of the permeable gap f
Development of enhanced geothermal systems (EGS) will require creation of a reservoir of sufficient volume to enable commercial-scale heat transfer from the reservoir rocks to the working fluid. A key assumption associated with reservoir creation/stimulation is that sufficient rock volumes can be hydraulically fractured via both tensile and shear failure, and more importantly by reactivation of naturally existing fractures (by shearing), to create the reservoir. The advancement of EGS greatly depends on our understanding of the dynamics of the intimately coupled rock-fracture-fluid-heat system and our ability to reliably predict how reservoirs behave under stimulation and production. Reliable performance predictions of EGS reservoirs require accurate and robust modeling for strongly coupled thermal-hydrological-mechanical (THM) processes. Conventionally, these types of problems have been solved using operator-splitting methods, usually by coupling a subsurface flow and heat transport simulators with a solid mechanics simulator via input files. An alternative approach is to solve the system of nonlinear partial differential equations that govern multiphase fluid flow, heat transport, and rock mechanics simultaneously, using a fully coupled, fully implicit solution procedure, in which all solution variables (pressure, enthalpy, and rock displacement fields) are solved simultaneously. This paper describes numerical simulations used to investigate the poro- and thermal- elastic effects of working fluid injection and thermal energy extraction on the properties of the fractures and rock matrix of a hypothetical EGS reservoir, using a novel simulation software FALCON (Podgorney et al., 2011), a finite element based simulator solving fully coupled multiphase fluid flow, heat transport, rock deformation, and fracturing using a global implicit approach. Investigations are also conducted on how these poro- and thermal-elastic effects are related to fracture permeability evolution.
Permeability in reactive porous media evolves in complex ways that are hard to predict. Macroscopic empirical equations are often used to estimate permeability evolution but fail to reflect the impact of pore scale reactions on permeability. This work aims to understand the evolution of permeability in systems where mineral dissolution and precipitation occur simultaneously. Pore network models are used for permeability simulation of a Paluxy sandstone using pore and pore-throat size distributions from the analysis of X-ray CT images. Pore and pore-throat radii are increased and decreased to reflect the effects of dissolution and precipitation reactions. Varying spatial distributions of reactions are simulated and the resulting porosity and permeability values compared with commonly used macroscopic equations. It is observed that when dissolution occurs at the inlet and precipitation at the outlet, porosity increases while permeability decreases. Similar results are also observed in the respective opposite scenario where precipitation occurs at the inlet and dissolution at the outlet. When dissolution and precipitation reactions are randomly distributed throughout the network, porosity increases with little change in permeability that is not captured by the empirical equations. When reactions are controlled by pore and pore-throat sizes, such as dissolution occurring in pores and pore-throats of small size and precipitation in pores and pore-throats of larger size, porosity and permeability decrease. When precipitation occurs in pores and pore-throats of smaller size and dissolution in pores and pore-throats of larger size, porosity and permeability increase and is described relatively well by the Verma-Pruess porosity-permeability equation.
Proton translocation is important in membrane-mediated processes such as ATP-dependent proton pumps, ATP synthesis, bacteriorhodopsin, and cytochrome oxidase function. The fundamental mechanism, however, is poorly understood. To test the theoretical possibility that bundles of hydrophobic alpha-helices could provide a low energy pathway for ion translocation through the lipid bilayer, polyamino acids were incorporated into extruded liposomes and planar lipid membranes, and proton translocation was measured. Liposomes with incorporated long-chain poly-L-alanine or poly-L-leucine were found to have proton permeability coefficients 5 to 7 times greater than control liposomes, whereas short-chain polyamino acids had relatively little effect. Potassium permeability was not increased markedly by any of the polyamino acids tested. Analytical thin layer chromatography measurements of lipid content and a fluorescamine assay for amino acids showed that there were approximately 135 polyleucine or 65 polyalanine molecules associated with each liposome. Fourier transform infrared spectroscopy indicated that a major fraction of the long-chain hydrophobic peptides existed in an alpha-helical conformation. Single-channel recording in both 0.1 N HCl and 0.1 M KCl was also used to determine whether proton-conducting channels formed in planar lipid membranes (phosphatidylcholine/phosphatidylethanolamine, 1:1). Poly-L-leucine and poly-L-alanine in HCl caused a 10- to 30-fold increase in frequency of conductive events compared to that seen in KCl or by the other polyamino acids in either solution. This finding correlates well with the liposome observations in which these two polyamino acids caused the largest increase in membrane proton permeability but had little effect on potassium permeability. Poly-L-leucine was considerably more conductive than poly-L-alanine due primarily to larger event amplitudes and, to a lesser extent, a higher event frequency. Poly-L-leucine caused two populations of conductive events, one in the 0.1-0.5 pA range, and one in the 1.0-5.0 pA range, whereas nearly all events caused by poly-L-alanine were in the 0.1-0.5 pA range at an applied voltage of +60 mV. The channel-like activity appeared to switch between conductive and nonconductive states, with most open-times in the range of 50-200 ms. We conclude that hydrophobic polyamino acids produce proton-conducting defects in lipid bilayers that may be used to model functional proton channels in biological membranes.
We studied the relation between rupture and changes in permeability within a fault zone intersecting the Opalinus Clay formation at 300 m depth in the Mont Terri Underground Research Laboratory (Switzerland). A series of water injection experiments were performed in a borehole straddle interval set within the damage zone of the main fault. A three-component displacement sensor allowed an estimation of the displacement of a minor fault plane reactivated during a succession of step rate pressure tests. The experiment reveals that the fault hydromechanical (HM) behavior is different from one test to the other with varying pressure levels needed to trigger rupture and different slip behavior under similar pressure conditions. Numerical simulations were performed to better understand the reason for such different behavior and to investigate the relation between rupture nucleation, permeability change, pressure diffusion, and rupture propagation. Here, our main findings are as follows: (i) a rate frictional law and a rate-and-state permeability law can reproduce the first test, but it appears that the rate constitutive parameters must be pressure dependent to reproduce the complex HM behavior observed during the successive injection tests; (ii) almost similar ruptures can create or destroy the fluid diffusion pathways; (iii) a too high or too low diffusivity created by the main rupture prevents secondary rupture events from occurring whereas “intermediate” diffusivity favors the nucleation of a secondary rupture associated with the fluid diffusion. However, because rupture may in certain cases destroy permeability, this succession of ruptures may not necessarily create a continuous hydraulic pathway.
In future nuclear fuel reprocessing plants and possibly for nuclear power plants, the cleanup of tritiated water will be needed for hundreds of thousands of gallons of water with low activities of tritium. This cleanup concept utilizes graphene oxide laminar membranes (GOx) for the separation of low-concentration (10 -3 -10 µCi/g) tritiated water to create water that can be released to the environment and a much smaller waste stream with higher tritium concentrations. Graphene oxide membranes consist of hierarchically stacked, overlapping molecular layers and represent a new class of materials. A permeation rate test was performed with a 2-µm-thick cast Asbury membrane using mixed gas permeability testing with zero air (highly purified atmosphere) and with air humidified with either H 2 O or D 2 O to a nominal 50% relative humidity. The membrane permeability for both H 2 O and D 2 O was high with N 2 and O 2 at the system measurement limit. The membrane water permeation rate was compared to a Nafion® membrane and the GOx permeation was approximately twice as high at room temperature. The H 2 O vapor permeation rate was 5.9 × 10 2 cc/m 2 /min (1.2 × 10 -6 g/min-cm 2 ), which is typical for graphene oxide membranes. To demonstrate the feasibility of such isotopic water separation through GOX laminar membranes, an experimental setup was constructed to use pressure-driven separation by heating the isotopic water mixture at one side of the membrane to create steam while cooling the other side. Several membranes were tested and were prepared using different starting materials and by different pretreatment methods. The average separation result was 0.8 for deuterium and 0.6 for tritium. Higher or lower temperatures may also improve separation efficiency but neither has been tested yet. A rough estimate of cost compared to current technology was also included as an indication of potential viability of the process. The relative process costs were based on the rough size of facility to accommodate the large surface area of the membranes and the energy needed to evaporate the water and pass through the membranes as compared to the currently used combined electrolysis and catalytic exchange process.
A method of fabricating improved transformer cores from composites of thermoplastic matrices and iron-particles has been invented. Relative to commercially available laminated-iron-alloy transformer cores, the cores fabricated by this method weigh less and are less expensive. Relative to prior polymer-matrix/ iron-particle composite-material transformer cores, the cores fabricated by this method can be made mechanically stronger and more magnetically permeable. In addition, whereas some prior cores have exhibited significant eddy-current losses, the cores fabricated by this method exhibit very small eddy-current losses. The cores made by this method can be expected to be attractive for use in diverse applications, including high-signal-to-noise transformers, stepping motors, and high-frequency ignition coils. The present method is a product of an experimental study of the relationships among fabrication conditions, final densities of iron particles, and mechanical and electromagnetic properties of fabricated cores. Among the fabrication conditions investigated were molding pressures (83, 104, and 131 MPa), and molding temperatures (250, 300, and 350 C). Each block of core material was made by uniaxial-compression molding, at the applicable pressure/temperature combination, of a mixture of 2 weight percent of LaRC (or equivalent high-temperature soluble thermoplastic adhesive) with 98 weight percent of approximately spherical iron particles having diameters in the micron range. Each molded block was cut into square cross-section rods that were used as core specimens in mechanical and electromagnetic tests. Some of the core specimens were annealed at 900 C and cooled slowly before testing. For comparison, a low-carbon-steel core was also tested. The results of the tests showed that density, hardness, and rupture strength generally increased with molding pressure and temperature, though the correlation was rather weak. The weakness of the correlation was attributed to the pores in the specimens. The maximum relative permeabilities of cores made without annealing ranged from 30 to 110, while those of cores made with annealing ranged from 900 to 1,400. However, the greater permeabilities of the annealed specimens were not associated with noticeably greater densities. The major practical result of the investigation was the discovery of an optimum distribution of iron-particle sizes: It was found that eddy-current losses in the molded cores were minimized by using 100 mesh (corresponding to particles with diameters less than or equal to 100 m) iron particles. The effect of optimization of particle sizes on eddy-current losses is depicted in the figure.
The invention relates to porous films comprising crosslinked electrospun hydrogel fibers. Viable microbes are encapsulated within the crosslinked electrospun hydrogel fibers. The crosslinked electrospun hydrogel fibers are water insoluble and permeable. The invention also relates to methods of making and using such porous films.