Search NASA⌕ Search

SEARCH · Search NASA

Results for “Supervisory control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Quasi-Wireless Capacitive Power Transfer with Secure Data Acquisition for Robotic Systems in Space Infrastructure

Space exploration is dependent on robotic systems that utilize end-effectors to collect samples, probe surfaces, and manipulate objects. These systems can rarely be designed to do all three, forcing engineers to make tradeoffs based on the mission parameters - i.e. should the robotic appendage have a claw, drill, or shovel, and which would be best suited for the mission? Additionally, as more industrial and government entities partake in space exploration, data protection is needed in transit and at rest. To address these challenges, we present a first-of-its- kind robotic linkage that has no wiring between the joints. Instead, quasi-wireless capacitive (QWiC) power transfer is used to send energy over the robot’s chassis without a return wire. This enables the system to be completely modular through the use of single-contact permanent magnet connections, allowing rapid alterations in joint kinematics and/or the changing of end-effectors. For collecting sensor data from the robotic arm and to send remote commands to it, we use a Supervisory Control and Data Acquisition (SCADA) system. Data transmission relies on MQTT and OPC UA communication protocols with encryption. The SCADA server logs and archives sensor data and provides the functionality for authorized users to send remote commands from SCADA client(s) to motors. A SCADA client can be any of the web browsers that connects to a server via a secure communication channel using SSL protocol. Furthermore, as an extra data protection mechanism, we inject noise to the sensor data traffic, which obfuscates the timing of sensor data packets and adds confusion about which data packet represents which motor.

wireless sensor networks↗

A Framework for Dynamic Architecture and Functional Allocations for Increasing Airspace Autonomy

To enable scalability of air travel for use cases such as cargo delivery, it is anticipated that future air traffic operations will involve unmanned aircraft operated by remote pilots. Of particular interest are schemes where a small number of pilots operate a large number of vehicles, mitigating high cost and pilot shortage issues. Such architectures require increased levels of automation and supervisory control modes. They also require ensuring safe operations when the command and control link to the vehicle is degraded or lost completely, rendering the vehicle autonomous. To evaluate these variable and dynamic architectures, this paper will present a framework for decomposing the functions necessary to ensure safe, orderly, and expeditious air travel, assessing the agents in the system, and classifying the levels of autonomy. Then, an example allocation to agents of roles for the function of separation assurance is presented, highlighting the dependency of the allocation on three main factors: time criticality of a potential separation violation, the ratio of pilots to vehicles, and the loss of the command and control link.

air traffic management, function allocation, auton↗

A Framework for Dynamic Architecture and Functional Allocations for Increasing Airspace Autonomy

To enable scalability of air travel for use cases such as cargo delivery, it is anticipated that future air traffic operations will involve unmanned aircraft operated by remote pilots. Of particular interest are schemes where a small number of pilots operate a large number of vehicles, mitigating high cost and pilot shortage issues. Such architectures require increased levels of automation and supervisory control modes. They also require ensuring safe operations when the command and control link to the vehicle is degraded or lost completely, rendering the vehicle autonomous. To evaluate these variable and dynamic architectures, this paper will present a framework for decomposing the functions necessary to ensure safe, orderly, and expeditious air travel, assessing the agents in the system, and classifying the levels of autonomy. Then, an example allocation to agents of roles for the function of separation assurance is presented, highlighting the dependency of the allocation on three main factors; time criticality of a potential separation violation, the ratio of pilots to vehicles, and the loss of the command and control link.

air traffic management↗

RTCA Special Committee 228 Working Group (DAA) 1

The Radio Technical Commission for Aeronautics (RTCA) is an American organization comprised of government, industry, and academic stakeholders in aviation for the purpose of providing technical guidance to regulatory authorities. In late 2022, RTCA Special Committee 228 (Minimum Performance Standards for Unmanned Aircraft Systems) decided to form a working group to study a burgeoning multi-vehicle, supervisory control paradigm colloquially known as "m:N" (vocalized as "em-to-en"). Within the m:N control paradigm, multiple aircraft (N) are collaboratively managed by a body of operators/pilots (m). This presentation describes the scope of the m:N working group and its goal of producing an Operational Service and Environment Definition (OSED) for m:N operations.

RTCA↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

EMIS↗

Solving the Dynamics-Aware Economic Dispatch Problem with the Koopman Operator

The dynamics-aware economic dispatch (DED) problem embeds low-level generator dynamics and operational constraints to enable near real-time scheduling of generation units in a power network. DED produces a more dynamic supervisory control policy than traditional economic dispatch (T-ED) that reduces overall generation costs. However, in contrast to T-ED, DED is a nonlinear, non-convex optimization problem that is computationally prohibitive to solve. We introduce a machine learning-based operator-theoretic approach for solving the DED problem efficiently. Specifically, we develop a novel discrete-time Koopman Operator (KO) formulation that embeds domain information into the structure of the KO to learn high-fidelity approximations of the generator dynamics. Using the KO approximation, the DED problem can be reformulated as a computationally tractable linear program (abbreviated DED-KO). We demonstrate the high solution quality and computational-time savings of the DED-KO model over the original DED formulation on a 9-bus test system.

King, Ethan↗

Companion Assisted Software Based Remote Attestation in SCADA Networks

Critical infrastructure such as power generation and water distribution systems have become a priority target in cyber warfare because of their recent computerization and introduction to the internet. As a result, Supervisory Control and Data Acquisition (SCADA) system security has become a hot topic in academic and industrial research. Among these topics, Remote Attestation is a security method intended to detect the presence of fileless malware in remote devices as they continue to operate. This allows for the detection of malware in the absence of long-term storage artifacts before symptoms of compromise begin to appear. In general, a trusted device (the verifier) makes a request for evidence of innocence from the untrusted device (the prover). In software-based schemes, the verifier can then measure the delay between its request and the prover’s response. If this delay is greater than the known computational time of the evidence gathering algorithm performed by the prover, then evidence may have been forged. Multi-hop networks often introduce too much network jitter to allow accurate measurement of prover response time, which limits the effectiveness of software based Remote Attestation in a real-world setting. In this work, we introduce a companion device that the verifier can trust to perform a subset of attestation, thereby removing any network jitter. This device is a Field Programmable Gate Array (FPGA) that is physically connected to the prover. We provide a communication protocol between the verifier, prover, and companion. To evaluate our scheme, we simulate it in a common SCADA network environment under normal and heavy traffic loads. Our simulations are performed in the discrete event network simulator NS-3, and we perform statistical analysis over our results to show that our scheme allows for tight timing constraints to be placed on the prover such that the verifier can more easily determine the validity of the evidence that it receives.

Johnson, William A.↗

Investigation of Multiple Data Streams for Gearbox Bearing Fault Prediction Through Machine-Learning Models

Operations and maintenance (O&M) cost of wind plant accounts up to 30% of total energy cost, which can be reduced through continuous monitoring and successfully detecting incipient wind turbine failures. To accomplish this, condition monitoring and predictive maintenance systems are being implemented in wind industry to support O&M decision making. A wide range of approaches for condition monitoring and fault prediction have been developed. These approaches generally use historical data of wind turbines collected by Supervisory Control and Data Acquisition (SCADA) system to identify patterns that lead to failure. These SCADA data show the overall condition of a wind turbine and can be leveraged to detect when the turbine's performance is degrading and to identify if a fault is developing. However, it becomes challenging to predict the failure of a specific wind turbine gearbox bearing, because the SCADA data are often not directly linked to the component. To bridge the gap, we have investigated features calculated from SCADA data using physics-based models and the gearbox design over the years. The damaged metric we used in the physics domain is frictional energy. Combining these physics domain variables with SCADA data as inputs to various machine learning models for gearbox bearing fault prediction, we have demonstrated the benefits of leveraging both physics and data domain models. It was an attempt to improve frictional-energy-based damage metric by adding data domain inputs, as we had learned that the frictional-energy-based damage metric alone is not sufficient to single out failed bearings from healthy. As condition monitoring data (either vibration or oil debris data) has become available at more and more wind plants, we would like to evaluate whether by adding the condition monitoring data can help further improve the performance of frictional-energy-based damage metric for gearbox bearing fault prediction. Both cases by modeling through various machine learning algorithms are discussed in this study along with some observations.

fault prediction↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

A Comparison of Preconstruction and Operational Wake Loss Estimates for Land-Based Wind Plants

Recent studies suggest that biases between wind plant pre-construction energy yield estimates and actual energy production are decreasing over time. However, variability in energy yield prediction accuracy across different projects and wind energy consultants remains high. Wake effects are one of the largest categories comprising the pre-construction energy yield assessment process. To assess the accuracy of wake loss predictions, we compare pre-construction wake loss estimates provided by 8 consultants to the estimated operational wake losses for 10 North American wind plants, as part of the Wind Plant Performance Prediction (WP3) Benchmark project. We estimate operational wake losses using supervisory control and data acquisition (SCADA) data by comparing total wind plant energy production to the potential energy production based on the power produced by freestream wind turbines. In the presentation, we will discuss the overall wake loss prediction bias as well as the project-to-project variability in the prediction accuracy. Further, we will highlight challenges encountered when estimating operational wake losses, including the impact of complex terrain and the presence of neighboring wind plants.

benchmark↗

Uncertainty Error Modeling for Non-Linear State Estimation With Unsynchronized SCADA and µPMU Measurements

Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro phasor measurement units (µPMUs) facilitate co-synchronized measurements with high granularity, albeit at an often prohibitively expensive installation cost. Supervisory control and data acquisition (SCADA) measurements can supplement µPMU data, although they are received at a slower sampling rate. Further complicating matters is the uncertainty associated with load dynamics and unsynchronized measurements–not only are the SCADA and µPMU measurements not synchronized with each other, but the SCADA measurements themselves are received at different time intervals with respect to one another. This paper proposes a non-linear state estimation framework which models dynamic load uncertainty error by updating the variances of the unsynchronized measurements, leading to a time-varying system of weights in the weighted least squares state estimator. Case studies are performed on the 33-Bus Distribution System in MATPOWER, using Ornstein–Uhlenbeck stochastic processes to simulate dynamic load conditions.

Cooper, Austin↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications: Preprint

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaNbased DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

Network visualization, intrusion detection, and network healing

The present disclosure is related to a cyber-security system that includes a Supervisory Control and Data Acquisition (SCADA) network monitor configured to receive a data set from a power system network, an event manager, and a mitigation system, where the SCADA network monitor includes an anomaly detector.

Rivera, Joshua Eli↗

SULI End of Summer Presentation

This presentation made on Power Point is a brief summary of my work enhancing the Supervisory Control and Data Acquisition (SCADA) architecture for Idaho National Lab’s Critical Infrastructure Test Range Complex (CITRC). This work was part of an on-going project to create a digital twin of CITRC that will be implemented for resiliency research. Resiliency is growing more important as extreme weather, aging infrastructure, and increasing load all exert stress on the United States power grid. This presentation highlights how I documented the existing devices and data flow on site and then updated specific device settings to better support the needs of the project. It also examines future use of this data in the digital twin data warehouse (DeepLynx), and future Artificial Intelligence and Advanced Distribution Management System applications. It will be presented to the B751 Water and Energy Systems Analysis group at INL during my last week.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Dual-arm supervisory and shared control space servicing task experiments

A dual-arm task execution primitive has been implemented for cooperative dual-arm telerobotic task execution utilizing multiple sensors concurrently. The primitive has been integrated into a telerobot task execution system and can be called by a task planning system for execution of tasks requiring dual-arm sensor based motion, e.g., force control, teleoperation, and shared control. The primitive has a large input parameter set which is used to specify the desired behavior of the motion. Move-squeeze decomposition is utilized to decompose forces sensed at the wrists of the two manipulators into forces in the move subspace, which cause system motion, and forces in the squeeze subspaces, which cause internal forces. The move and squeeze forces are then separately controlled. Several space servicing tasks utilizing the cooperative dual-arm control capability are described, and experimental results from the tasks are given. The supervisory and shared control tasks include capture of a rotating satellite, orbital replacement unit changeout, fluid coupler seating and locking, and contour following.

Backes, Paul G.↗

Adaptive control with an expert system based supervisory level

Adaptive control is presently one of the methods available which may be used to control plants with poorly modelled dynamics or time varying dynamics. Although many variations of adaptive controllers exist, a common characteristic of all adaptive control schemes, is that input/output measurements from the plant are used to adjust a control law in an on-line fashion. Ideally the adjustment mechanism of the adaptive controller is able to learn enough about the dynamics of the plant from input/output measurements to effectively control the plant. In practice, problems such as measurement noise, controller saturation, and incorrect model order, to name a few, may prevent proper adjustment of the controller and poor performance or instability result. In this work we set out to avoid the inadequacies of procedurally implemented safety nets, by introducing a two level control scheme in which an expert system based 'supervisor' at the upper level provides all the safety net functions for an adaptive controller at the lower level. The expert system is based on a shell called IPEX, (Interactive Process EXpert), that we developed specifically for the diagnosis and treatment of dynamic systems. Some of the more important functions that the IPEX system provides are: (1) temporal reasoning; (2) planning of diagnostic activities; and (3) interactive diagnosis. Also, because knowledge and control logic are separate, the incorporation of new diagnostic and treatment knowledge is relatively simple. We note that the flexibility available in the system to express diagnostic and treatment knowledge, allows much greater functionality than could ever be reasonably expected from procedural implementations of safety nets. The remainder of this chapter is divided into three sections. In section 1.1 we give a detailed review of the literature in the area of supervisory systems for adaptive controllers. In particular, we describe the evolution of safety nets from simple ad hoc techniques, up to the use of expert systems for more advanced supervision capabilities.

Sullivan, Gerald A.↗