Development of low-resistivity silicon drift detector arrays for soft X-rays
N/A
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
N/A
N/A
Purpose: To accurately measure CT bow-tie profiles from various manufacturers and to provide non-proprietary information for CT system modeling. Methods: A GOS-based linear detector (0.8 mm per pixel and 51.2 cm in length) with a fast data sampling speed (0.24 ms/sample) was used to measure the relative profiles of bow-tie filters from a collection of eight CT scanners by three different vendors, GE (LS Xtra, LS VCT, Discovery HD750), Siemens (Sensation 64, Edge, Flash, Force), and Philips (iBrilliance 256). The linear detector was first calibrated for its energy response within typical CT beam quality ranges and compared with an ion chamber and analytical modeling (SPECTRA and TASMIP). A geometrical calibration process was developed to determine key parameters including the distance from the focal spot to the linear detector, the angular increment of the gantry at each data sampling, the location of the central x-ray on the linear detector, and the angular response of the detector pixel. Measurements were performed under axial-scan modes for most representative bow-tie filters and kV selections from each scanner. Bow-tie profiles were determined by re-binning the measured rotational data with an angular accuracy of 0.1 degree using the calibrated geometrical parameters. Results: The linear detector demonstrated an energy response as a solid state detector, which is close to the CT imaging detector. The geometrical calibration was proven to be sufficiently accurate (< 1mm in error for distances >550 mm) and the bow-tie profiles measured from rotational mode matched closely to those from the gantry-stationary mode. Accurate profiles were determined for a total of 21 bow-tie filters and 83 filter/kV combinations from the abovementioned scanner models. Conclusion: A new improved approach of CT bow-tie measurement was proposed and accurate bow-tie profiles were provided for a broad list of CT scanner models.
This report is a summary of results for the DRiFT Stilbene simulation research at LANL. It describes the project overview and motivation, approach, and results.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Device employs sensitive photoelectric electrodes and solid-state memory, can be used at visible UV and X ray wavelengths, includes nonmagnetic proximity focusing, and is immune to high energy charged-particle background.
Explore the source record for details and available documents.
An introduction to overall IR array concepts and particular array designs is presented, and examples of laboratory and observational data obtained with IR arrays are given. Hybrid array designs, extrinsic silicon accumulation-mode charge injection devices, and switched-FET or switched-sample photoconductor techniques are summarized. Three recent astronomical observation projects which used IR arrays are examined.
Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.
The development of a high density Schottky barrier Infrared Charged Coupled Device (IRCCD) type image sensor for earth observation was initiated. A dual band 512 pixel linear array was developed, which was capable of being butted end to end to make an arbitrarily long linear array. Measurement made on palladium silicide IRCCDs that were two-dimensional 63 x 32 pixel arrays were summarized. The test data on a 512 pixel linear array is also summarized.
High-speed (1 Gbit/x) dual-wavelength demultiplexing and detection in a monolithic linear array of superlattice p-i-n photodetectors in a waveguide configuration is demonstrated. A crosstalk attenuation of 28 dB was achieved between two digital transmission channels with an interchannel wavelength spacing of 30 nm. The device performance is a result of an enhanced electroabsorption due to the quantum-confined Stark effect in the superlattice p-i-n diodes.
The commonly used methods to evaluate the performance of a two-dimensional focal-plane array using charge transfer devices are reviewed. Two figures of merit that attempt to combine quantum efficiency, read noise and dark-current generation into a single parameter are discussed. The figures of merit are suggested as possible alternatives to the D asterisk.
Proposed rectangular array of photodetectors in imaging spectrometer includes integral filter deposited directly on imaging array which would not become misaligned or misregistered as result of mechanical shock, vibration, or differential thermal expansion. Need for precise alignment and registration of filter cannot be over-emphasized.
Infrared polarimetry pictures of star forming regions were obtained. The magnetic field structure of the disk is examined. The design of the infrared telescope is described.
A spectral imaging system having an integrated filter and photodetector array is disclosed. The filter has narrow transmission bands which vary in frequency along the photodetector array. The frequency variation of the transmission bands is matched to, and aligned with, the frequency variation of a received spectral image. The filter is deposited directly on the photodetector array by a low temperature deposition process. By depositing the filter directly on the photodetector array, permanent alignment is achieved for all temperatures, spectral crosstalk is substantially eliminated, and a high signal to noise ratio is achieved.
256 x 256-element IBC Si:As arrays have been evaluated for applications in IR astronomy from space-borne platforms. Basic figures of merit were measured at IR flux levels simulating those expected in space-based astronomical observations. Results include dark current less than 20 e(-)/s, G-eta as high as 3.8, eta/beta of 20%, and read noise below 100 rms(e(-)).