On-Board Calibrator for the Multi-angle Imaging SpectroRadiometer

The EOS/MISR instrument includes nine pushroom cameras, each at different view to Earth, and an on-board calibrator. The latter includes photodiode detectors, used as the radiometric standards for the experiment, and two Spectralon diffuse panels.

Multi-angle Imaging SpectroRadiometer pushroom cam↗

Evaluation of Detector-to-Detector and Mirror Side Differences for Terra MODIS Reflective Solar Bands Using Simultaneous MISR Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the five Earth-observing instruments on-board the National Aeronautics and Space Administration (NASA) Earth-Observing System(EOS) Terra spacecraft, launched in December 1999. It has 36 spectral bands with wavelengths ranging from 0.41 to 14.4 mm and collects data at three nadir spatial resolutions: 0.25 km for 2 bands with 40 detectors each, 0.5 km for 5 bands with 20 detectors each and 1 km for the remaining 29 bands with 10 detectors each. MODIS bands are located on four separate focal plane assemblies (FPAs) according to their spectral wavelengths and aligned in the cross-track direction. Detectors of each spectral band are aligned in the along-track direction. MODIS makes observations using a two-sided paddle-wheel scan mirror. Its on-board calibrators (OBCs) for the reflective solar bands (RSBs) include a solar diffuser (SD), a solar diffuser stability monitor (SDSM) and a spectral-radiometric calibration assembly (SRCA). Calibration is performed for each band, detector, sub-sample (for sub-kilometer resolution bands) and mirror side. In this study, a ratio approach is applied to MODIS observed Earth scene reflectances to track the detector-to-detector and mirror side differences. Simultaneous observed reflectances from the Multi-angle Imaging Spectroradiometer (MISR), also onboard the Terra spacecraft, are used with MODIS observed reflectances in this ratio approach for four closely matched spectral bands. Results show that the detector-to-detector difference between two adjacent detectors within each spectral band is typically less than 0.2% and, depending on the wavelengths, the maximum difference among all detectors varies from 0.5% to 0.8%. The mirror side differences are found to be very small for all bands except for band 3 at 0.44 mm. This is the band with the shortest wavelength among the selected matching bands, showing a time-dependent increase for the mirror side difference. This study is part of the effort by the MODIS Characterization Support Team (MCST) in order to track the RSB on-orbit performance for MODIS collection 5 data products. To support MCST efforts for future data re-processing, this analysis will be extended to include more spectral bands and temporal coverage.

Wu, Aisheng↗

Calibration of the High Energy Replicated Optics to Explore the Sun (HEROES) Hard X-ray Telescope

On September 21-22, 2013, the High Energy Replicated Optics to Explore the Sun (HEROES) hard X-ray telescope, flew as a balloon payload from Ft. Sumner, N.M. HEROES observed the Sun, the black hole binary GRS 1915+105, and the Crab Nebula during its 27 hour flight. In this paper we describe laboratory calibration measurements of the HEROES detectors using line and continuum sources, applications of these measurements to define channel to energy (gain) corrections for observed events and to define detector response matrices. We characterize the HEROES X-ray grazing incidence optics using measurements taken in the Stray-Light (SLF) Facility in Huntsville, AL, and using ray traces.

Wilson-Hodge, Colleen A.↗

Calibrating the broad band X-ray telescope

This paper describes the calibration of the two solid-state Si(Li) X-ray detectors and the X-ray telescopes that flew as part of Goddard Space Flight Center's Broad Band X-Ray Telescope (BBXRT) experiment on board the space shuttle Columbia in 1990 December. During the 9 day shuttle mission, BBXRT performed approximately 150 observations of 82 celestial sources. The content of the archive is summarized here. Although BBXRT had a relatively short life, it stands as a milestone in X-ray astronomy as being the first instrument to offer moderate spectral resolution over a wide bandpass (0.3-12.0 keV). Among other things, this paper discusses the effective area calibration of the instrument, the flux calibration and flux corrections for off-axis observations, the detector background, and optimal background subtraction techniques. The on-axis effective area calibration for the central detector elements was performed using data from the Crab Nebula, while other carefully selected targets were used for calibration of the outer detector elements. The remaining systematic uncertainties in the effective area calibration for point sources observed both on and off axis are generally less than 5%-10%. The energy scale is known to better than 0.5% at 6.0 keV for both detectors. The results presented here have an impact on the calibration of other medium resolution X-ray experiments such as the CCDs on board ASCA (Astro-D) as well as the Advanced X-Ray Astrophysics Facility detectors.

Weaver, K. A.↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Image plane detector for the dynamics explorer Fabry-Perot interferometer

A compact twelve-channel photon-counting device based on existing Generation II imaging technology has been developed for use as the image-plane detector of the Dynamics Explorer Fabry-Perot interferometer. The device has an S-20 photocathode, three-microchannel plate electron multiplication stages, and an equal-area concentric-ring segmented anode whose geometry mimics that of the interference ring pattern produced by a plane etalon. The twelve channels sample equal and contiguous intervals in the spectrum. The purpose of the delopment has been to utilize the signal multiplex advantage of a multichannel detector in the measurement of Doppler shifts and line-broadening effects for naturally occurring atmospheric emission features of low intensity. The design, testing, calibration, and flight performance of the novel detector system are presented. In addition, measured emission line profiles at high resolution from the satellite instrument are presented to illustrate the operation of the device.

Killeen, T. L.↗

A new array for the study of ultra high energy gamma-ray sources

The design and operation of a 32 x 1 10 to the 15th power sq m array of scintillation detectors for the detection of 10 to the 15th power eV cosmic rays is described with an expected angular resolution of 1 deg, thus improving the present signal/background ratio for gamma ray sources. Data are recorded on a hybrid CAMAC, an in-house system which uses a laser and Pockel-Cell arrangement to routinely calibrate the timing stability of the detectors.

Brooke, G.↗

In-Flight Calibration of ESA Hera’s Hyperscout-H Imager

ESA’s Hera space mission is on its way to the mission target, the binary asteroid (65803) Didymos. HyperScout-H, one of the instruments onboard Hera, is a hyperspectral imager operating in the visible and near-infrared regions between 0.65 and 0.95 μm. HyperScout-H will enable a detailed assessment of the composition of both objects, Didymos and its satellite Dimorphos, the characterization of space weathering effects, and the possible presence of exogenous material on their surfaces. To monitor instrument functionality, calibration exposures are acquired regularly. This article describes the in-flight calibrations carried out for HyperScout-H during the commissioning and cruise phases. Bias and dark exposures, as well as stellar field observations, were acquired several times after launch. We update the calibration data and monitor instrument performance in the space environment. In addition, images of Earth and Moon were acquired from distances of 1.5 × 10 6 to 2.0 × 10 6 km, and Mars and its satellite were imaged during the flyby. In five images, the surface of Mars fills the entire field of view, enabling cross-validation of HyperScout-H results with those reported by other Mars missions. We characterize the detector under in-flight operational conditions. The calibration data indicate that the bias pattern is stable, the dark current remains negligible for short exposures, and the detector response is highly linear. We quantify the field-of-view alignment and geometric distortion, and evaluate the point spread function based on the stellar field observations. Stellar observations and Mars swing-by data provide updated radiometric calibration constants, suggesting that in-flight conditions have slightly modified the detector’s spectral response. In-flight calibrations are essential to ensure data quality and reliability.

Image Processing↗

IXPE: The Imaging X-ray Polarimetry Explorer, Implementing a Dedicated Polarimetry Mission

Only a few experiments have conducted x-ray polarimetry of cosmic sources since Weisskopf et al confirmed the 19% polarization of the Crab Nebula with the Orbiting Solar Observatory (OSO-8) in the 70's center dot The challenge is to measure a faint polarized component against a background of non-polarized signal (as well as the other, typical background components) center dot Typically, for a few % minimum detectable polarization, 106 photons are required. center dot So, a dedicated mission is vital with instruments that are designed specifically to measure polarization (with minimal systematic effects) Over the proposed mission life (2- 3 years), IXPE will first survey representative samples of several categories of targets: magnetars, isolated pulsars, pulsar wind nebula and supernova remnants, microquasars, active galaxies etc. The survey results will guide detailed follow-up observations. Precise calibration of IXPE is vital to ensuring sensitivity goals are met. The detectors will be characterized in Italy, and then a full calibration of the complete instrument will be performed at MSFC's stray light facility. Polarized flux at different energies Heritage: X-ray Optics at MSFC polarimetry mission.

Ramsey, Brian↗

A motion detection system for AXAF X-ray ground testing

The concept, implementation, and performance of the motion detection system (MDS) designed as a diagnostic for X-ray ground testing for AXAF are described. The purpose of the MDS is to measure the magnitude of a relative rigid body motion among the AXAF test optic, the X-ray source, and X-ray focal plane detector. The MDS consists of a point source, lens, centroid detector, transimpedance amplifier, and computer system. Measurement of the centroid position of the image of the optical point source provides a direct measure of the motions of the X-ray optical system. The outputs from the detector and filter/amplifier are digitized and processed using the calibration with a 50 Hz bandwidth to give the centroid's location on the detector. Resolution of 0.008 arcsec has been achieved by this system. Data illustrating the performance of the motion detection system are also presented.

Arenberg, Jonathan W.↗

Application of wedge and strip image readout systems to detectors for astronomy

Microchannel plate (MCP) detector systems that use wedge and strip anodes for imaging radiation in the range 50 A to 8000 A are described. Test data, obtained from the calibration of the Extreme Ultraviolet Explorer Satellite detectors and the ARIA EUV aeronomy sensor is presented. The long-term performance characteristics of Z-stack microchannel plates are investigated and it is shown that stable operation is achieved after an initial settling period. Conventional and new anode designs and their potential for increasing the position resolution are discussed. Position resolution of better than 80 microns FWHM has been attained for 50 mm devices, and this is shown to be essentially independent of event location. Image nonlinearity of less than 0.3 percent has been achieved with stability to better than 0.1 percent. Differential nonlinearity of less than 1 percent and stability to better than 1 percent have been obtained. Measurements of the quantum efficiency of a CsI photocathode on an MCP are presented, demonstrating efficiencies as high as 47 percent.

Siegmund, O. H. W.↗

Cryogenic radiometers and intensity-stabilized lasers for Eos radiometric calibrations

Liquid helium-cooled electrical substitution radiometers (ESRs) provide irradiance standards with demonstrated absolute accuracy at the 0.01 percent level, spectrally flat response between the UV and IR, and sensitivity down to 0.1 nW/sq cm. We describe an automated system developed for NASA - Goddard Space Flight Center, consisting of a cryogenic ESR illuminated by servocontrolled laser beams. This system is designed to provide calibration of single-element and array detectors over the spectral range between 257nm in the UV to 10.6 microns in the IR. We also describe a cryogenic ESR optimized for black body calibrations that has been installed at NIST, and another that is under construction for calibrations of the CERES scanners planned for Eos.

Foukal, P.↗

Assessment of Terra MODIS Thermal Emissive Band Calibration Using Cold Targets and Measurements in Lunar Roll Events

Terra MODIS has provided continuous global observations for science research and applications for more than 18 years. The MODIS Thermal emissive bands (TEB) radiometric calibration uses a quadratic function for instrument response. The calibration coefficients are updated using the response of an on-board blackbody (BB) in quarterly warm-up and cool-down (WUCD) events. As instrument degradation and electronic crosstalk of long-wave infrared (LWIR) bands 27 to 30 developed substantial issues, accurate calibration is crucial for a high-quality L1B product. The on-board BB WUCD temperature ranges from 270 K to 315 K and the derived nonlinear response has a relatively large uncertainty for the offset, especially for these LWIR bands, which affects the measurements of low brightness temperature (BT) scenes. In this study, the TEB radiometric calibration impact on the L1B product is assessed using selected cold targets and the measurements during regular lunar rolls. The cold targets include Antarctic Dome Concordia (Dome-C) and deep convective clouds (DCC) for the calibration assessment, focusing on bands 27 to 30. Dome-C area is covered with uniformly-distributed permanent snow, and the atmospheric effect is small and relatively constant. Usually the DCC is treated as an invariant earth target to evaluate the reflective solar band calibration. The DCC can also be treated as a stable target to assess the performance of TEB calibration. During a scheduled lunar observation event with a spacecraft roll maneuver to view the moon through the space view port, the instrument cavity provides a stable reference for calibration assessment. The long-term trending of BT measurements and the relative difference between scan mirror sides and detectors are used for the assessment of the calibration consistency and stability. The comparison of L1B products over the selected targets before and after the calibration coefficients update can be used to assess the impact of a calibration look-up table (LUT) update. This assessment is beneficial for future calibration algorithm and LUT update procedure improvements for enhancing the L1B product quality.

Chang, Tiejun↗

The (55)Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays

The accurate determination of a detector's fundamental parameters, including read noise, dark current, and QE, relies on a proper measurement of a detector's conversion gain (e- ADU(exp -1)). Charge coupling effects, such as interpixel capacitance, attenuate photon shot noise and result in an overestimation of conversion gain when implementing the photon transfer technique. An approach involving (55)Fe X-rays provides a potentially straightforward measurement of conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by the X-ray. This technique is already preferred within the CCD community, as the pair production energy for silicon is well established. In contrast, to date the pair production energy is unknown for HgCdTe, a material commonly used for near-infrared detectors. In this paper, we derive a preliminary calibration of the (55)Fe X-ray energy response of HgCdTe using 8 HST WFC3 1.7 micrometers flight grade detectors. Our conversion of the X-ray intensities from counts into electrons implements a technique that restores the 'true' gain via classical propagation of errors. For these detectors, our analysis yields preliminary results of good statistical precision: each Ka event generates 1849 +/- 46 electrons, which corresponds to a pair production energy of 3.21+/-f 0.08 eV. We are continuing to assess potential systematic effects to further refine the accuracy of this result.

Fox, Ori↗

First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket

Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018, from the White Sands Missile Range, USA. This flight marks the first successful operation of a transition-edge sensor array and its time-division multiplexing readout system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The onboard calibration source provided X-rays in flight, and it is used to compare detector performance during preflight integration, flight, and after the successful post-flight recovery. This calibration data demonstrate the capabilities of the detector in a space environment as well as its potential for future flight.

TES↗

Time Resolved Irradiance of an Integrating Sphere Illuminated by a Mode-Locked Optical Parametric Oscillator

Tunable laser based illumination sources have been adopted by a number of recent hyperspectral instruments for pre-launch spectral radiometric calibration. Some of these sources use mode-locked cavity configurations, which produce a pulse train and create an undesirable fluctuation in the radiometric source at the mode locking frequency. Although typically this frequency is several orders of magnitude higher than the instrument response, care must be taken to ensure the resultant calibration is not biased due to detector or electronic saturation effects. The temporal averaging properties of an integrating sphere can be used to reduce high frequency fluctuations to an acceptable level. In this work, the time resolved output of an integrating sphere coupled with a mode-locked source was measured. A 76 cm diameter sphere with 30 cm output aperture was illuminated using a mode-locked pulse train at 76 MHz, with single pulse durations of 12 ps. The time constant of the sphere was found to be 36 ns, and the resultant temporal averaging of pulses produced a maximum time varying irradiance at the output of 20% of the mean. The form of this time variance is a sawtooth pattern, with a sharp rise during the introduction of each pulse into the sphere followed by a slower decay between pulses. A comparison of instrument calibration data generated with this integrating sphere using both a mode locked source and a continuous wave source is also given. .

McAndrew, Brendan↗

Landsat-8 TIRS Thermal Radiometric Calibration Status

The Landsat-8 Thermal Infrared Sensor (TIRS) has been acquiring two-band thermal infrared images of the Earth’s surface since 2013. The calibration of the two-band system has been monitored using the on-board calibrator and validated with vicarious calibration performed by NASA/JPL and RIT since launch. Soon after launch, it was discovered that the instrument had a significant stray light effect that was affecting the radiometric calibration. The stray light was corrected in the processing system in 2017. Since then, it has become apparent that there was an additional radiometric error, based on the vicarious calibration results. With a failure within the primary electronic system and subsequent switch to the redundant electronic system, the TIRS instrument effectively has two separate calibration regimes. The vicarious calibration found a statistically significant calibration error, primarily a constant over time, in Band 11 on the primary electronics (Feb 11,2013 through March 5,2015) of about -0.6K at 300K. The calibration error in Band 10 was smaller though still statistically significant at about 0.2K at 300K. On the redundant side(March 5,2015 to present), the calibration error is more signal dependent than time dependent. Both bands are affected, with Band 10 having an error between 1K and -0.4K (between 273-320K) and Band 11 having an error between 0.8K and -1.44K (between 273-320K).This calibration error will be corrected within the USGS Landsat Product Generation System with the release of Landsat Collection-2 products. The Collection-2 release also includes a correction to the relative radiometric calibration of TIRS data. Striping as a result of poor detector-to-detector normalization has been increasing in the imagery since launch. The TIRS relative radiometric calibration will be updated based on internal calibrator data to remove the stripes on a quarterly basis. The visible stripes are generally at 0.1-0.2% level, though there are some detectors in each band that have changed by 1% or more. The Collection-2 release will result in much more uniform TIRS images.

Julia A Barsi↗