Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Initial Results of a Phase 2 Trial of 18F-DOPA PET-Guided Dose-Escalated Radiation Therapy for Glioblastoma

Our previous work demonstrated that 3,4-dihydroxy-6-[18F]-fluoro-L-phenylalanine ({sup 18}F-DOPA) positron emission tomography (PET) is sensitive and specific for identifying regions of high density and biologically aggressive glioblastoma. The purpose of this prospective phase 2 study was to determine the safety and efficacy of biologic-guided, dose-escalated radiation therapy (DERT) using {sup 18}F-DOPA PET in patients with glioblastoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy With a High Maximum Dose Improves Local Control, Cancer-Specific Death, and Overall Survival in Peripheral Early-Stage Non-Small Cell Lung Cancer

We investigated whether delivery of a high biologically effective dose (BED) to primary tumors affects systemic outcomes of cancer-specific death (CSD) and overall survival (OS) rates after stereotactic body radiation therapy (SBRT) in patients with early-stage non-small cell lung cancer (ES-NSCLC).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Escalated Radiation Therapy for Glioblastoma Multiforme: An International Systematic Review and Meta-Analysis of 22 Prospective Trials

Limited evidence is available on the utility of dose-escalated radiation therapy (DE-RT) with or without temozolomide (TMZ) versus standard-of-care radiation therapy (SoC-RT) for patients with newly diagnosed glioblastoma multiforme. We performed a systematic review/meta-analysis to compare overall survival (OS) and progression-free survival (PFS) between DE-RT and SoC-RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mixed Effect Modeling of Dose and Linear Energy Transfer Correlations With Brain Image Changes After Intensity Modulated Proton Therapy for Skull Base Head and Neck Cancer

Intensity modulated proton therapy (IMPT) could yield high linear energy transfer (LET) in critical structures and increased biological effect. For head and neck cancers at the skull base this could potentially result in radiation-associated brain image change (RAIC). The purpose of the current study was to investigate voxel-wise dose and LET correlations with RAIC after IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fractionated Low-Dose Radiation Induces Long-Lasting Inflammatory Responses in the Hippocampal Stem Cell Niche

Despite major technical advances in hippocampus-sparing radiation therapy, radiation-induced injury to the neural stem cell compartment may affect neurocognitive functions. In the brain, glial cells modulate neuronal functions and are major mediators of neuroinflammation. In a preclinical mouse model with fractionated low-dose radiation (LDR), the complex response to radiation-induced injury was analyzed in the hippocampal stem cell compartment over a period of 6 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AI-Based Quantification of Planned Radiation Therapy Dose to Cardiac Structures and Coronary Arteries in Patients With Breast Cancer

The purpose of this work is to develop and evaluate an automatic deep learning method for segmentation of cardiac chambers and large arteries, and localization of the 3 main coronary arteries in radiation therapy planning on computed tomography (CT). In addition, a second purpose is to determine the planned radiation therapy dose to cardiac structures for breast cancer therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Clinical Cell-Cycle Risk (CCR) score Is Associated With Metastasis After Radiation Therapy and Provides Guidance on When to Forgo Combined Androgen Deprivation Therapy With Dose-Escalated Radiation

The clinical cell-cycle risk (CCR) score, which combines the University of California, San Francisco's Cancer of the Prostate Risk Assessment (CAPRA) and the cell cycle progression (CCP) molecular score, has been validated to be prognostic of disease progression for men with prostate cancer. This study evaluated the ability of the CCR score to prognosticate the risk of metastasis in men receiving dose-escalated radiation therapy (RT) with or without androgen deprivation therapy (ADT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

UV–Visible reflectance of common light reflectors and their degradation after an ionization dose up to 100 Mrad

We report light reflectors are widely used to enhance scintillation light collection. Their enhancement level depends on the reflector’s reflectance at the scintillator’s emission wavelength. We report UV–Visible reflectance spectra, relative to BaSO 4 , for several common reflectors. Also reported is their radiation hardness against an ionization dose up to 100 Mrad. The results of this investigation provide a reference for applications of these reflectors in a severe radiation environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comprehensive Analysis of Streaming and Shutdown Dose Rate Experiments at JET with ORNL Fusion Neutronics Workflows

Current experimental fusion systems and conceptual designs of fusion pilot plants (FPPs) are growing in complexity and size. Several radiation metrics are crucial to the safe operation of fusion machines, including neutron flux streaming through openings and the shutdown dose rate (SDDR). Most current designs of advanced experimental fusion systems—and the most probable candidates for FPPs—are based on the tokamak concept, which is prone to neutron streaming through the myriad openings needed for diagnostic and support systems. SDDR is caused by decay gamma rays from radionuclides that become activated by neutrons during the operation of a fusion system that use deuterium-deuterium (DD), tritium-tritium, or deuterium-tritium plasma. Because computational tools have become essential for determining these radiation metrics, they must be validated against reliable and applicable experimental data. Experiments at the Joint European Torus (JET) provide a unique source of experimental data for validating computational tools and nuclear data used to determine SDDR and neutron fluxes in streaming-dominated geometries. Here, this paper presents the comprehensive analysis of the high-performance DD JET SDDR, and streaming experiments performed using Oak Ridge National Laboratory (ORNL) fusion workflows. The computational results were compared with experimental results that consist of online SDDR measurements with ionization chambers and neutron fluence streaming measurements using thermoluminescent detectors. The ratio of calculated-to-experimental SDDR values ranges from 0.6 to 2.5, and the streaming results range from 0.5 to 8.0. Future work will include analyzing the JET 2021 DTE2 campaign alongside the integration of the Shift Monte Carlo transport code into all ORNL fusion neutronics workflows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A New Shutdown Dose Rate Benchmark Problem for Representative Fusion Applications

Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.

Benchmark↗

New Total-Ionizing-Dose Resistant Data Storing Technique for NAND Flash Memory

This paper describes a new non-charge-based data storing technique in NAND flash memory called watermark that encodes read-only data in the form of physical properties of flash memory cells. Unlike traditional charge-based data storing method in flash memory, the proposed technique is resistant to total ionizing dose (TID) effects. To evaluate its resistance to irradiation effects, we analyze data stored in several commercial single-level-cell (SLC) flash memory chips from different vendors and technology nodes. These chips are irradiated using a Co-60 gamma-ray source array for up to 100 krad(Si) at Sandia National Laboratories. Experimental evaluation performed on a flash chip from Samsung shows that the intrinsic bit error rate (BER) of watermark increases from 0.8% for TID = 0 krad(Si) to 1% for TID = 100 krad(Si). Conversely, the BER of charge-based data stored on the same chip increases from 0% at TID = 0 krad(Si) to 1.5% at TID = 100 krad(Si). Overall, the results imply that the proposed technique may potentially offer significant improvements in data integrity relative to traditional charge-based data storage for very high radiation (TID > 100 krad(Si)) environments. These gains in data integrity relative to the charge-based data storage are useful in radiation-prone environments, but they come at the cost of increased write times and higher BERs before irradiation.

36 MATERIALS SCIENCE↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

Evaluation of Microreactor Inhalation Dose Consequences

The new generation of microreactors are intended to provide useful, very reliable and safe safe energy for a variety of applications such as supplying to remote locations. Microreactors range from less than 1 MW th to more than 20 MW th . A range of technologies is being considered, including variations in neutron energy spectrum (fast or thermal), variations in primary and secondary coolant choices (e.g. metal cooled, gas cooled, and unique power cycle reactors. The reactors tend to use new fuel forms and types with unique benefits such as metal or TRISO fuel for higher fuel density and safety, respectively. The notional image of a microreactor is a reactor that fits in a seavan or intermodal shipping container. This would allow conventional shipping options, including aircraft, and match other mobile power sources. A development of a capability to test these reactors is needed, whether in a facility or in an open area. INL is in the process of determining acceptable test areas for these various reactors and an understanding of potential bounding consequences is important in informing siting and required infrastructure capability decisions. This ECAR considers the bounding release fractions of these types of reactors at 20 MW th and documents the dose consequences to the public and collocated worker. This is a scoping analysis for the generalized type of reactor, and the analysis will be refined based on the specific reactor design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗