Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Meso-Structured Polymer Electrolyte Fuel Cell Electrode

Increasing the utilization of Pt and Pt alloy catalysts in polymer electrolyte fuel cell cathodes is critical to improving the high power density operation, particularly at low Pt loadings. State of the art electrodes are fabricated in an ink deposition process that leads to uncontrolled electrode architecture with random aggregates of functional domains (catalyst, ionomer, and pore volume) (1). The randomness in the domains induces high tortuosity transport pathways for ions and fluids, which cause severe transport resistance during high current density operation. Thin ionomer films cause additional transport resistance and poisoning of the Pt catalyst, which becomes more significant at low Pt loadings. Reducing the amount of ionomer in the catalyst domain without affecting the ionic transport resistance is key to improving the utilization of the Pt and reducing the transport resistance at low Pt loading. Rational design of the electrode structure with controlled low tortuous ionic transport pathways could improve performance. The introduction of the ionomer pathways could also enable reduction of the ionomer volume in the catalyst domain, reducing the transport resistance. Middelmen et al. proposed electrode structures consisting of aligned components in a low tortuosity configuration to improve performance (2). In this work, we present an alternative electrode structure based on a vertically aligned array of Nafion pillars in the cathode catalyst layer, as shown in Figure 1a. Figure 1b shows the SEM image of the Nafion pillars. Furthermore, Pt supported on carbon catalyst was deposited on the Nafion pillars to fabricate a meso-structured electrode. Nafion pillars provide high conductive and low tortuous pathways for protons, reducing the effective transport distance, and enabling reduction of the ionomer binder in the catalyst domain.

25 ENERGY STORAGE↗

E-tongue 2 REDOX response to heavy metals

E-Tongue 2 an array of electrochemical sensors including REDOX electrodes for Cylic Voltammetry and Anodic Stripping Voltammetry measurements, Galvanic cells for corrosion measurements, and Ion Selective Electrodes.

electromechanical sensors↗

Retarded Charge-Carrier Recombination in Photoelectrochemical Cells from Plasmon-Induced Resonance Energy Transfer

N-type metal oxides such as hematite (α-Fe 2 O 3 ) and bismuth vanadate (BiVO 4 ) are promising candidate materials for efficient photoelectrochemical water splitting; however, their short minority carrier diffusion length and restricted carrier lifetime result in undesired rapid charge recombination. In this paper, a 2D arranged globular Au nanosphere (NS) monolayer array with a highly ordered hexagonal hole pattern (hereafter, Au array) is introduced onto the surface of photoanodes comprised of metal oxide films via a facile drying and transfer-printing process. Through plasmon-induced resonance energy transfer, the Au array provides a strong electromagnetic field in the near-surface area of the metal oxide film. The near-field coupling interaction and amplification of the electromagnetic field suppress the charge recombination with long-lived photogenerated holes and simultaneously enhance the light harvesting and charge transfer efficiencies. Consequently, an over 3.3-fold higher photocurrent density at 1.23 V versus reversible hydrogen electrode (RHE) is achieved for the Au array/α-Fe 2 O 3 . Furthermore, the high versatility of this transfer printing of Au arrays is demonstrated by introducing it on the molybdenum-doped BiVO 4 film, resulting in 1.5-fold higher photocurrent density at 1.23 V versus RHE. The tailored metal film design can provide a potential strategy for the versatile application in various light-mediated energy conversion and optoelectronic devices.

2D pattern array↗

Time-Encoded Gamma-Ray Imaging Using a 3-D Position-Sensitive CdZnTe Detector Array

The gamma-ray response of thick pixelated CdZnTe detectors varies spatially but is relatively constant as a function of time. Detector irregularities arise from flaws in the material, electrode fabrication, and gaps between the detectors in an array. These nonuniformities generate artifacts in coded aperture images that can obscure a source of interest. This article presents the theory, design, and demonstration of a 3-D CdZnTe-based time-encoded imager. Experimental results show the gamma-ray images of point-like and extended 57 Co and HEU-metal sources formed using a spatially nonuniform 3-D CdZnTe detector array and moving coded aperture mask. Image signal-to-noise ratio (SNR) for a point source was within 10% of its statistical limit at 250k counts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-protected electrodes limit field-emission current

One cathode includes array of square-shaped conductor columns. Columns are electrically interconnected by conducting plate on bottom. Each column provides field-emission current. Another cathode includes array of rodlike conductors. Layer is covered by control film made of conducting material. Film is isolated from each conductor.

Lees, W. L.↗

Next-Generation Microshutter Arrays for Large-Format Imaging and Spectroscopy

A next-generation microshutter array, LArge Microshutter Array (LAMA), was developed as a multi-object field selector. LAMA consists of small-scaled microshutter arrays that can be combined to form large-scale microshutter array mosaics. Microshutter actuation is accomplished via electrostatic attraction between the shutter and a counter electrode, and 2D addressing can be accomplished by applying an electrostatic potential between a row of shutters and a column, orthogonal to the row, of counter electrodes. Microelectromechanical system (MEMS) technology is used to fabricate the microshutter arrays. The main feature of the microshutter device is to use a set of standard surface micromachining processes for device fabrication. Electrostatic actuation is used to eliminate the need for macromechanical magnet actuating components. A simplified electrostatic actuation with no macro components (e.g. moving magnets) required for actuation and latching of the shutters will make the microshutter arrays robust and less prone to mechanical failure. Smaller-size individual arrays will help to increase the yield and thus reduce the cost and improve robustness of the fabrication process. Reducing the size of the individual shutter array to about one square inch and building the large-scale mosaics by tiling these smaller-size arrays would further help to reduce the cost of the device due to the higher yield of smaller devices. The LAMA development is based on prior experience acquired while developing microshutter arrays for the James Webb Space Telescope (JWST), but it will have different features. The LAMA modular design permits large-format mosaicking to cover a field of view at least 50 times larger than JWST MSA. The LAMA electrostatic, instead of magnetic, actuation enables operation cycles at least 100 times faster and a mass significantly smaller compared to JWST MSA. Also, standard surface micromachining technology will simplify the fabrication process, increasing yield and reducing cost.

Moseley, Samuel↗

Carbon Nanofiber Nanoelectrode Arrays for Neural Implant Devices

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

carbon nanotubes↗

Sensor array and apparatus for simultaneous observation of tissue electrophysiology, contractility, and growth

A method includes simultaneously measuring electrophysiological responses and contractility responses of a plurality of cells forming a tissue culture using a system comprising a sensor array configured to simultaneously measure the electrophysiological responses and the contractility responses of the plurality of cells forming the tissue culture. Fabrication techniques for making such systems include: forming a sensor array comprising an interpenetrating arrangement of IDEs and electrodes of a MEA in or on a substrate surface; forming a plurality of contacts for interfacing the system with one or more external devices in or on the substrate surface; and forming leads between the plurality of contacts and the sensor array.

Qian, Fang↗

Fluctuations and turbulence in an electric field Bumpy Torus plasma

Fluctuation characteristics of plasma number density and electrostatic potential below the ion plasma and ion cyclotron frequencies in an electric field Bumpy Torus plasma were investigated experimentally, using digitally implemented spectral analysis techniques. The toroidal plasma was biased to high potentials by applying positive or negative voltage to electrodes located in the midplanes of two sectors of the toroidal array. The plasma was observed to be biased to 80 or 90% of the potential on the midplane electrodes, regardless of polarity. The radial electric field exceeded 1 kV/cm at the plasma boundary and penetrated inward to at least one-half of the plasma radius. When the imposed radial electric fields reached values characteristic of the experiment, the E/B drift velocities were comparable to the particle thermal velocities. The amplitude statistics of both the density and the potential fluctuations were found to be Gaussian for the most part, with near-zero skewness and a kurtosis of about 3.0. The spectral index of the density and potential fluctuations ranged from 2 to 6. The higher frequency components were found to propagate faster than the E/B drift velocity, which is the characteristic speed of the lower-frequency components.

Roth, J. R.↗

High power density fuel cell comprising an array of microchannels

A fuel cell according to one embodiment includes a porous electrolyte support structure defining an array of microchannels, the microchannels including fuel and oxidant microchannels; fuel electrodes formed along some of the microchannels; and oxidant electrodes formed along other of the microchannels. A method of making a fuel cell according to one embodiment includes forming an array of walls defining microchannels therebetween using at least one of molding, stamping, extrusion, injection and electrodeposition; processing the walls to make the walls porous, thereby creating a porous electrolyte support structure; forming anode electrodes along some of the microchannels; and forming cathode electrodes along other of the microchannels. Additional embodiments are also disclosed.

30 DIRECT ENERGY CONVERSION↗

Scalable and automated CRISPR-based strain engineering using droplet microfluidics

Abstract We present a droplet-based microfluidic system that enables CRISPR-based gene editing and high-throughput screening on a chip. The microfluidic device contains a 10 × 10 element array, and each element contains sets of electrodes for two electric field-actuated operations: electrowetting for merging droplets to mix reagents and electroporation for transformation. This device can perform up to 100 genetic modification reactions in parallel, providing a scalable platform for generating the large number of engineered strains required for the combinatorial optimization of genetic pathways and predictable bioengineering. We demonstrate the system’s capabilities through the CRISPR-based engineering of two test cases: (1) disruption of the function of the enzyme galactokinase ( galK ) in E. coli and (2) targeted engineering of the glutamine synthetase gene ( glnA ) and the blue-pigment synthetase gene ( bpsA ) to improve indigoidine production in E. coli .

42 ENGINEERING↗

Electric spiking activity in epithelial cells

Epithelial cells (human keratinocyte cells and the canine MDCK cell line), traditionally viewed as electrically non-self-excitable and involved primarily in physiological functions such as barrier presentation, absorption, secretion, and protection, are shown here to exhibit traveling extracellular electric charge when they recover from spatially focused, laser-induced wounding of confluent monolayers cultured on a multielectrode array chip. Voltage spikes measured on these electrodes display depolarization, repolarization, and hyperpolarization phases with amplitudes similar to the action potentials of neurons but with the markedly slower duration of 1 to 2 s. Some propagate distances up to hundreds of μm from the wound with a mean speed of around 10 mm s −1 . Generation and transmission of bioelectric signals are significantly influenced by the perturbation of mechanosensitive cationic ion channels. These direct measurements confirm bioelectric signaling that previous work has hypothesized to regulate epithelial cell development and may have relevance to the frequency parameter selection of bioelectric devices.

Science & Technology - Other Topics↗

Linear charge coupled device detector array for imaging light propagating in an integrated thin-film optical waveguide

Device design, fabrication, and operation of a linear charge coupled device (CCD) detector array integrated with a thin film optical waveguide and applications of this structure to integrated optical signal processing and fiber optical communications were discussed. A two phase, overlapping-gate CCD is connected in parallel by means of a series of gates to an array of photodiodes. The photodiode provides an electrode free surface region so that a highly efficient waveguide detector coupling technique can be implemented. A thermally-oxidized layer of SiO2 forms an effective substrate for the optical waveguide.

Chen, C. L.↗

Conceptual design of a hybrid Ge:Ga detector array

For potential applications in space infrared astronomy missions such as the Space Infrared Telescope Facility and the Large Deployable Reflector, integrated arrays of long-wavelength detectors are desired. The results of a feasibility study which developed a design for applying integrated array techniques to a long-wavelength (gallium-doped germanium) material to achieve spectral coverage between 30 and 200 microns are presented. An approach which builds up a two-dimensional array by stacking linear detector modules is presented. The spectral response of the Ge:Ga detectors is extended to 200 microns by application of uniaxial stress to the stack of modules. The detectors are assembled with 1 mm spacing between the elements. Multiplexed readout of each module is accomplished with integration sampling of a metal-oxide-semiconductor (MOS) switch chip. Aspects of the overall design, including the anticipated level of particle effects on the array in the space environment, a transparent electrode design for 200 microns response, estimates of optical crosstalk, and mechanical stress design calculations are included.

Parry, C. M.↗

Boundary Layer Flow Control with a One Atmosphere Uniform Glow Discharge Surface Plasma

Low speed wind tunnel data have been acquired for planar panels covered by a uniform, glow-discharge surface plasma in atmospheric pressure air known as the One Atmosphere Uniform Glow Discharge Plasma (OAUGDP). Streamwise and spanwise arrays of flush, plasma-generating surface electrodes have been studied in laminar, transitional, and fully turbulent boundary layer flow. Plasma between symmetric streamwise electrode strips caused large increases in panel drag, whereas asymmetric spanwise electrode configurations produced a significant thrust. Smoke wire flow visualization and mean velocity diagnostics show the primary cause of the phenomena to be a combination of mass transport and vortical structures induced by strong paraelectric ElectroHydroDynamic (EHD) body forces on the flow.

J Reece Roth↗

Mars Surveyor Program '01 Mars Environmental Compatibility Assessment wet chemistry lab: a sensor array for chemical analysis of the Martian soil

The Mars Environmental Compatibility Assessment (MECA) instrument was designed, built, and flight qualified for the now canceled MSP (Mars Surveyor Program) '01 Lander. The MECA package consisted of a microscope, electrometer, material patch plates, and a wet chemistry laboratory (WCL). The primary goal of MECA was to analyze the Martian soil (regolith) for possible hazards to future astronauts and to provide a better understanding of Martian regolith geochemistry. The purpose of the WCL was to analyze for a range of soluble ionic chemical species and electrochemical parameters. The heart of the WCL was a sensor array of electrochemically based ion-selective electrodes (ISE). After 20 months storage at -23 degrees C and subsequent extended freeze/thawing cycles, WCL sensors were evaluated to determine both their physical durability and analytical responses. A fractional factorial calibration of the sensors was used to obtain slope, intercept, and all necessary selectivity coefficients simultaneously for selected ISEs. This calibration was used to model five cation and three anion sensors. These data were subsequently used to determine concentrations of several ions in two soil leachate simulants (based on terrestrial seawater and hypothesized Mars brine) and four actual soil samples. The WCL results were compared to simulant and soil samples using ion chromatography and inductively coupled plasma optical emission spectroscopy. The results showed that flight qualification and prolonged low-temperature storage conditions had minimal effects on the sensors. In addition, the analytical optimization method provided quantitative and qualitative data that could be used to accurately identify the chemical composition of the simulants and soils. The WCL has the ability to provide data that can be used to "read" the chemical, geological, and climatic history of Mars, as well as the potential habitability of its regolith.

Non-NASA Center↗

Electrochemical detection of gas phase chemicals

We provide an electrochemical sensor in which working microelectrodes are arranged in an array and interconnected in parallel. The working electrodes are arranged so that in use, they are electrochemically coupled to a counter electrode structure through an electrolyte. The sensor also includes a microporous body arranged so that in use, it is situated at a boundary between a gaseous environment and the electrolyte. In another aspect, we provide a method of sensing in which a sample of gas is admitted to a liquid electrolyte maintained by pores of a porous substrate. A voltage is applied to the liquid electrolyte, and an electrical response to the applied voltage is observed, thereby to detect electrochemical evidence of an analyte within the liquid electrolyte.

Klavetter, Kyle C.↗

Flexible Microsensor Array for the Monitoring and Control of Plant Growth System

Testing for plant experiments in space has begun to explore active nutrient delivery concepts in which water and nutrients are replenished on a continuous basis for long-term growth. The goal of this study is to develop a novel microsensor array to provide information on the dissolved oxygen environment in the plant root zone for the optimum control of hydroponics and solid substrate plant cultivation systems in the space environment. Miniaturized polarographic dissolved oxygen sensors have been designed and fabricated on a flexible Kapton (trademark) (polyimide) substrate. Two capabilities of the new microsensor array were explored. First, measurements of dissolved oxygen in the plant root zone in hydroponics and solid substrate culture systems were made. The microsensor array was fabricated on a flexible substrate, and then cut out into a mesh type to make a suspended array that could be placed either in a hydroponics system or in a solid substrate cultivation system to measure the oxygen environments. Second, the in situ self-diagnostic and self-calibration capability (two-point for oxygen) was adopted by dynamically controlling the microenvironment in close proximity to the microsensors. With a built-in generating electrode that surrounds the microsensor, two kinds of microenvironments (oxygen-saturated and oxygen-depleted phases) could be established by water electrolysis depending on the polarity of the generating electrode. The unique features of the new microsensor array (small size, multiple sensors, flexibility and self-diagnosis) can have exceptional benefits for the study and optimization of plant cultivation systems in both terrestrial and microgravity environments. The in situ self-diagnostic and self-calibration features of the microsensor array will also enable continuous verification of the operability during entire plant growth cycles. This concept of automated control of a novel chemical monitoring system will minimize crew time required for maintenance, as well as reduce volume, mass, and power consumption by eliminating bulky diagnosis systems including calibrant (fluid and gas) reservoir and flow system hardware.

Kim, Chang-Soo↗