Search NASA⌕ Search

SEARCH · Search NASA

Results for “fleets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Light Water Reactor Sustainability Program: Technical and Economic Considerations for Uprate of Existing Nuclear Reactors with Cogeneration

The United States nuclear reactor fleet consists of 63 pressurized water reactors and 31 boiling water reactors and is a pivotal component in the nation's energy infrastructure, supplying approximately 97 GW e of clean power. With the country's commitment to decarbonization by 2050, these reactors are not only instrumental in decarbonizing the electricity grid but also play a critical role in decarbonizing industrial processes, producing clean fuels, and scaling up CO 2 removal. This report delves into the potential for power uprates in the existing fleet to contribute to these decarbonization efforts, focusing on the expansion of capacity for applications such as hydrogen production and carbon capture and sequestration. Building on previous research, the report explores regional market demands for hydrogen, oxygen, and carbon dioxide, financial implications of oxygen and CO 2 sales from high-temperature steam electrolysis systems, and the potential for direct air capture systems paired with uprated nuclear plants.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydropower Supply Chain Gap Analysis

In 2022, DOE conducted supply chain "deep dives" for renewable energy technologies, including hydropower (Uria-Martinez, Hydropower Industry Supply Chain Deep Dive Assessment 2022). The deep dive identified several challenges in the current hydropower supply chain. In addition, Nguyen et. al (2022) conducted an analogous deep-dive assessment on large (> 100-MW) power transformers (LPTs), a critical component of hydropower installations, and concluded that the LPTs as well as several upstream components and materials also have domestic supply chain challenges. These deep dives were the initial high-level assessments of these supply chains and were focused on identifying the biggest issues. Both recommended further investigation. In the two years since the deep dives were published, the Water Power Technologies Office (WPTO) has focused on improving our understanding of the hydropower supply chain and developing strategies for addressing these challenges. Because the challenges outlined above are most acute for large hydropower systems, most of the report and specifically, this report concentrates on the larger > 100-MW hydropower systems. Early in 2023, DOE's Secretary of Energy asked the Water Power Technologies Office (WPTO) to engage the hydropower community and seek input on strategies to secure and encourage domestic manufacturing. WPTO has established three focus areas for engagement: 1) Define the market for planned rehabilitations and new construction of the domestic fleet, 2) Provide insights for policies, incentives, loan programs, and technology investments to encourage domestic content, and 3) Define the existing and required domestic hydropower manufacturing capabilities and workforce. This report summarizes these efforts and complements the earlier work by further exploring the identified challenges and identifying potential actions to address these challenges. Furthermore, we conducted a detailed gap analysis of the domestic hydropower supply chain, down to the component level. From this analysis, we then make specific, actionable recommendations for closing these gaps. Section 2 of the report summarizes recent (i.e., since 2021) legislation impacting hydropower deployment and/or its supply chain. It then describes the efforts of WPTO to assess and improve the hydropower supply chain since the publication of the deep-dive assessments. In Section 3, the report updates the earlier supply chain and market studies, identifying specific capabilities by company and location. Section 4 outlines the hydropower demand signal for both new builds due to clean energy goals as well as refurbishments and upgrading of the current domestic fleet. Section 5 is a detailed gap analysis while Section 6 provides actionable recommendations for closing the gaps. Section 7 concludes the report by linking the recommendations to the identified gaps and discusses future efforts.

13 HYDRO ENERGY↗

Assessment of Alternative Fueling Infrastructure in the United States

NHTSA uses the Corporate Average Fuel Economy (CAFE) Model to analyze potential CAFE standards and their impact on emissions and vehicle fleet composition. The CAFE model analyzes the application of potential technologies to the current automotive industry vehicle fleet to determine the feasibility of future CAFE standards and the associated costs and benefits of the standards. A significant portion of the engineering input development is related to the effectiveness (energy consumption reduction) of each fuel-saving technology and the combination of several fuel-saving technologies, including AFVs. The purpose of this report is to deepen NHTSA's understanding of alternative fueling infrastructure and its potential impact on the adoption of alternative fuel vehicles (AFVs) so that AFVs can be more accurately and comprehensively incorporated into the CAFE Model. This report analyzes the current state of alternative fueling infrastructure in the United States and its relationship to the light-, medium-, and heavy-duty AFV markets; explores the costs associated with alternative fueling infrastructure; investigates trends driving the deployment of alternative fueling infrastructure; explores how the adoption of various vehicle and fuel technologies may look in the future; and analyzes the evolution of alternative fueling corridors.

33 ADVANCED PROPULSION SYSTEMS↗

Kansas City, Missouri, Streetlight Electric Vehicle Charging: Strategies and challenges for site selection of streetlight electric vehicle infrastructure in Kansas City, Missouri (Final Report)

Public streetlight charging, whether on streets in central business districts or residential areas, provides easy charging access for apartment residents and homeowners alike. While most electric vehicle (EV) drivers charge at home, they do so in garages or on driveways they own. For renters and residents of multifamily housing (MFH), however, this may not be an option. EVs have a lower cost of ownership compared to conventional vehicles, and a used EV may be an affordable option for a lower-income household. But without easy access to charging, even a low-cost used EV may not be an option for a prospective buyer. An affordable curbside charging network has the potential to expand EV adoption into neighborhoods that have to date seen minimal interest and uptake of the technology and associated charging infrastructure. Streetlight charging networks can provide an economical, scalable, and effective approach to providing equitable and convenient charging. Metropolitan Energy Center (MEC) is dedicated to the mission of creating resource efficiency, environmental health, and economic vitality in the Kansas City region and beyond. Since 1983, MEC has provided resources, outreach, and training to make alternative fuels and energy efficiency commonplace. MEC led a streetlight charging pilot project that installed limited EV charging infrastructure on the streetlight system in Kansas City, Missouri, to demonstrate and test the benefits of curbside charging for EVs at existing on-street parking locations. The project aimed to cost-effectively expand the charging network in Kansas City to support residential charging and provide infrastructure in one or more charging deserts throughout the city. This pilot evaluates the impact and overall success of streetlight charging based on community feedback, utilization of charging infrastructure, technical feasibility, and cost. The project has pursued a data- and community-driven site selection process designed to identify sites with high demand and high opportunity for EV charging. This project was funded by the U.S. Department of Energy (DOE) and awarded to MEC through a competitive proposal process. The novelty and complexity of this project required an organization that could facilitate collaboration across levels of government, community members, and industry partners. For the past 25 years, through Kansas City Regional Clean Cities, MEC has worked with numerous public and private fleets on a variety of projects to improve the environmental performance and efficiency of the regional vehicle fleet. To advance affordable, efficient, and clean transportation efforts, DOE Clean Cities and Communities coalitions create local networks of public and private sector stakeholders and engage communities. Rooted within their local communities, the coalitions serve as experts and ambassadors, bringing to bear the collective knowledge, experience, and practical know-how of the entire network from within DOE, its national laboratories, and diverse stakeholders in the field. MEC and its project partners made in-kind contributions to leverage federal dollars for the benefit of the Kansas City community. Findings from this project will help determine the best applications for streetlight charging technologies to maximize funding impact and serve community needs. The team evaluated locations based on expected charging demand, technical feasibility, safety considerations, and enhanced charging network siting needs. Throughout the project, the team gathered feedback and evaluated ways to make public charging for EVs available to all community members. The insights will help Kansas City and other communities streamline future efforts to support EV drivers through public charging in the city right-of-way. Furthermore, this project will inform citywide guidance for future installations. MEC is committed to a transparent and publicly accessible approach that encourages the collaborative evaluation of streetlight charging. The project has engaged the community to proactively identify and evaluate the benefits and impacts of streetlight charging. It was a priority for the project to ensure the benefits of this pilot are distributed equitably to all members of the Kansas City community and that new charging opportunities and associated resources are available in diverse neighborhoods across the city. The charging infrastructure supports an affordable curbside charging network that will enable more drivers to choose EVs and provide easy charging access for all community members interested in driving an EV. The community feedback received through this project informed future resources and opportunities to make EVs more accessible to all members of the Kansas City community. MEC worked with several community partners on this project, including Missouri University of Science and Technology (MST), Pennsylvania State University (Penn State), the National Renewable Energy Laboratory (NREL); the city of Kansas City, Missouri; Evergy; Black and McDonald (B&M); LilyPad EV; EVNoire; and Westside Housing Organization (WHO). Project partners contributed to the cost match required for DOE grants through capital expenditures, personnel, and other in-kind contributions. Detailed descriptions of project team organizations can be found in Appendix A. Project Partners. Analysts at NREL and MST/PennState developed site maps based on demand and equity considerations. MEC conducted outreach to community members to garner input on project design and site selection, and received approval from the Missouri Public Service Commission (PSC) for Evergy’s EV charging station ownership. MEC worked with all partners to gather additional siting criteria and developed a site selection evaluation checklist, and partners conducted site visits to proposed installation sites. Next, B&M, Evergy, and the city executed all site agreements, conducted site-specific engineering design, acquired associated permits, and issued notices to proceed site by site or in small batches. Finally, from January to April 2023, the project team installed 23 EV charging stations built on Kansas City’s streetlight system in six council districts. Evergy will own, operate, and monitor the stations for 10 years, sharing charging data with MEC for at least 1 year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero Emission Cargo Transport (ZECT) II Demonstration: South Coast Air Quality Management District (Final Report)

The South Coast Air Quality Management District (South Coast AQMD), California Air Resources Board (CARB) and Southern California Association of Governments (SCAG) — the agencies responsible for preparing the State Implementation Plan required under the federal Clean Air Act — have agreed that attainment of federal air quality standards for the region will require a transition to the broad use of zero and near-zero emission energy sources in cars, trucks and other equipment. Accordingly, the 2012 South Coast AQMD Air Quality Management Plan, the SCAG 2012 Regional Transportation Plan, and the “Vision for Clean Air: A Framework for Air Quality and Climate Control Planning” all identify the need to immediately enact a phasing in of zero and near-zero emission technologies to meet air quality goals. In 2014, South Coast AQMD was awarded grant funding under the US Department of Energy Zero Emission Cargo Transport (ZECT) II Demonstration program to develop and demonstrate zero-emission drayage trucks for goods movement operations between the Port of Los Angeles (POLA) and Port of Long Beach (POLB) near dock rail yards and warehouses: 1) development and demonstration of zero-emission fuel cell range extended electric drayage trucks and 2) development and demonstration of hybrid electric drayage trucks. The purpose of this project was to accelerate deployment of zero emission cargo transport technologies to reduce harmful diesel emissions, petroleum consumption and greenhouse gases in the surrounding communities along the goods movement corridors that are impacted by heavy diesel traffic and the associated air pollution. Between 2014 – 2024, six ZECT II zero-emission fuel cell drayage truck platforms, including fuel cell range extended and CNG hybrid trucks, were successfully designed, developed, integrated, built, tested, and demonstrated with drayage fleet operators in transportation corridors within areas of the South Coast AQMD jurisdiction in Southern California such as in and around POLA and POLB. Portable hydrogen refueling was deployed to support the fuel cell vehicles. The project had real-time improvement with on-going debugging and optimizations while the vehicles were under demonstration. All platforms demonstrated sufficient or excess power, torque, and energy to support 82,000lbs Gross Vehicle Weight Rating and gradeability to perform their daily duty cycles. Collectively, the trucks drove over 23,000 miles during their respective demonstration phases. The ZECT II project was the first of its kind to demonstrate the commercial viability that supported the additional technology breakthroughs for Class 8 zero emission trucks and validations as well as the regulatory basis for all the zero-emission regulation that we know today, such as the Innovative Clean Transit regulation, Advanced Clean Trucks and Clean Fleet regulations.

08 HYDROGEN↗

Hydrogen Transportation and Distributed Energy Systems Risk and Feasibility Assessment for Airport Facilities - CRADA 555 (Abstract)

This CRADA presents the strategy that Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) will take to support PDX in performing a risk assessment for several hydrogen deployment scenarios. It is intended that the deployment of hydrogen at PDX could serve several roles, including decarbonizing its bus fleet and building out a distributed energy system which could also be used to facilitate emergency operations. PDX’s initial plans concern replacing their current fleet of 28 busses with FCEBs. To do so, PDX will need to deploy the hydrogen systems needed to support the buses. This includes hydrogen storage, production, delivery, filling, compression, and maintenance. PDX also has long range plans to build a distributed energy system to support normal and resilient operations. This study will investigate the risks of each plan individually, and a combined plan which serves both. Additionally, PDX is in an area with the potential for high seismic activity, as such this work will also include a seismic risk assessment. A detailed risk assessment using PDX as a test case is necessary to ensure the deployment of large-scale hydrogen is successful and to understand the benefits or drawbacks in contrast to electric only technologies. Many technologies have been proposed that claim to utilize hydrogen for both transportation and distributed energy systems; however, these technologies need to be analyzed as they apply to an actual site. The physical infrastructure and hydrogen use cases for PDX will be analyzed, a risk assessment will be performed on the hydrogen infrastructure and distributed energy system. These assessments will be useful for understanding how each of these technologies would perform as applied to a large public facility and public safety. The results of this CRADA, and an impact of the DOE funding, will evaluate hydrogen as a key fuel for PDX and will accelerate by several years availability of hydrogen, fuel cells, and other low-carbon technologies.

08 HYDROGEN↗

White Paper: Scalable Digital Twin Capabilities for Aging and Surveillance of Engineered Systems

This white paper presents a multi-year initiative to develop practical, secure, and scalable digital twin capabilities for engineered systems in aging and surveillance contexts—an approach pioneered at the National Nuclear Security Administration (NNSA) Lawrence Livermore National Laboratory (LLNL) that maps directly onto the needs and ambitions of the Navy for ship- and fleet-level digital twins. LLNL’s work in building part- and process-level digital twins for advanced manufacturing, with a vision to scale up to entire factory floors and, ultimately, enterprise-wide digital twins, offers an adaptable pathway for the Navy as it seeks to modernize lifecycle management, readiness, and predictive maintenance across ships and fleets. For our application, we integrate physics-based modeling with automated data ingestion, processing, and AI-driven calibration, creating hybrid models that are both interpretable and data responsive. We modernized legacy workflows, established centralized data infrastructure, automated experimental pipelines, and demonstrated end-to-end coupling of accelerated aging data with finite element simulations via optimization and surrogate modeling. The result is a generalizable framework that supports part-level digital twins today and lays the groundwork for future system-level twins suitable for Navy applications.

36 MATERIALS SCIENCE↗

EVI-LOCATE User Manual

One of the longest stages in the deployment of electric vehicle supply equipment (EVSE) is the initial planning of the infrastructure itself. Engineers and fleet experts from the National Renewable Energy Laboratory (NREL) have supported dozens of charging infrastructure site plans over the past couple decades, including the generation of site schematics, determinations of electric capacity, and estimates for likely costs. As the market for electric vehicles (EVs) has matured, this approach should no longer require a time and personnel intensive process. In order to shorten the time taken to develop site plans and cost estimates, NREL developed a tool that fleet managers, facility managers, electricians, EVSE installers, and members of the public can use to develop initial schematics and ballpark pricing for charging station installations. The Electric Vehicle Infrastructure - Locally Optimized Charger Assessment Tool and Estimator (EVI-LOCATE) provides a structured and consistent way for users to enter information about their planned EVSE project in a relatively simple web-based format. EVI-LOCATE then calculates electrical equipment capacity, wiring runs, and project costs. It produces a site diagram optimized around surface characteristics with differential trenching costs for softscape such as grass compared to hardscape such as asphalt that can be adjusted by users in the tool. It also stores the resulting site plans and costs in a dashboard for access at a later date, including plan revisions if necessary. This document guides users through the EVI-LOCATE screens and associated questions. It contains tip text boxes throughout on how best to interface with the tool and find additional information or context. The appendices contain the assumptions and calculations underpinning the tool. Much of the information for EVI-LOCATE was gathered through industry engagements with EVSE installers, invoices from completed EVSE installations, Gordian's RS Means construction data, and the General Services Administration blanket purchase agreement for EVSE. For a visual tutorial of the tool, users can watch EVI-LOCATE Step-by-Step Video. The tool itself is available at https://evi-locate.nrel.gov.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Computational materials reliability assessment of hydrogen fueled gas turbine power generation engines

The use of blended fuel sources in land based gas turbine engines drives variations in the resulting operational profile (temperatures and pressures) which can impact engine reliability. Furthermore, variability in the manufacture of components affects the resulting microstructure which directly impacts material performance and reliability. Currently, data-driven models are typically used for maintaining and inspecting fleets of engines. Without explicitly capturing material and operational sources of variability conservatism must be used in developing component-level reliability models. Therefore, there exists an opportunity to use information from materials-scale physics models to better inform reliability modeling and reduce conservatism; the impact is more cost-efficient operation and maintenance of current and future fleets. Specifically, this work establishes a computational framework for evaluating the probabilistic high temperature creep performance of hot-section Ni-based superalloys where uncertainty comes from both microstructural and operational variability. A novel high-fidelity physics model which phenomenologically captures grain-boundary sensitive phenomena has been established. A probabilistic calibration procedure was used to calibrate the model and capture uncertainty in the parameterized model coefficients. A design of experiments methodology was established for identifying informative microstructural digital representations for suitable for forward model evaluation. Results show that training a machine-learning surrogate using this design criteria outperforms random selection of microstructural representations. Finally, two surrogate models were developed: (1) a deterministic surrogate model which predicts the local field response given microstructure, constitutive model parameters, and operating conditions (stress, temperature) and (2) a probabilistic model, where uncertainty comes from constitutive law uncertainty, built using denoising diffusion probabilistic models which samples responses given (1) microstructure and (2) operating conditions. These surrogate models enable partner Siemens Energy to rapidly perform UQ analysis specific to creep deformation across a range of microstructures and operating conditions. The impact is that these ML and physics codes can be used to establish more advanced reliability models for the inspection, servicing, and maintenance of land based gas turbine engines.

36 MATERIALS SCIENCE↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

Human Factors and Technologies Design to Improve User Acceptance of Pooled Rideshare for Increasing Transportation System Energy Efficiency

This multi-year project delivered a comprehensive, human-factors-driven framework to understand, model, and improve pooled rideshare (PR) adoption in the United States. Through three large-scale national survey studies involving more than 16,000 participants across multiple cities and demographic groups, the research established one of the most extensive datasets to date on user perceptions, behavioral barriers, and service expectations related to pooled rideshare. These data revealed key human factors barriers of user acceptance of PR and suggested potential actionable experience optimizations that could lead to increased PR usage. This foundational knowledge guided the development of novel human-factors models and behavioral choice models that quantify how psychological, demographic, and trip-level factors influence willingness to pool. Building on these empirical insights, the project developed advanced behavioral modeling tools, including mixed logit and integrated choice and latent variable models, to capture both observable and latent influences on PR adoption. These models significantly improved the ability to predict riders’ acceptance of pooled trips, explaining choice heterogeneity through latent constructs such as safety, service experience, privacy concerns, time sensitivity, and environmental attitudes. Together, these models provide a robust analytical foundation for designing PR systems that more effectively meet user needs. The project translated human-factors insights and behavioral models into actionable technology innovations by extending POLARIS—an agent-based, activity-based travel simulation platform—into a fully functional pooled rideshare simulation environment. New PR modules, acceptance models, and regional scenarios were implemented for Greenville, SC and Austin, TX, enabling high-fidelity validation of algorithmic strategies under realistic demand and traffic conditions. The simulation platform supported the development and evaluation of adaptive discount-based assignment algorithms, enhanced willingness-to-pay formulations, demographic-aware incentive mechanisms, and a proactive joint assignment and repositioning strategy. Simulation results demonstrated substantial gains in pooling uptake, average vehicle occupancy, energy efficiency, and fleet profitability. In Greenville, pooling adoption more than doubled, while reductions in vehicle-miles traveled and energy consumption were significant. In Austin, pooling improvements were achieved with minimal service-quality trade-offs, and profitability increased across all fleet sizes. Through this research, we developed a comprehensive understanding of the human factors barriers that limit user acceptance of pooled rideshare services. These insights enabled the design of human-factors-aware pooled rideshare technologies that more effectively address user concerns and improve adoption rates. By integrating these models into an advanced agent-based simulation framework, we demonstrated that higher adoption of pooled rideshare can lead to measurable improvements in energy efficiency and system performance. Together, these contributions establish a validated pathway from human-centered analysis to technology development and energy-saving outcomes, supporting national goals for more sustainable and efficient mobility systems.

Jia, Yunyi↗

Measuring Flexibility through Reduction Potential

As electrical loads, electric vehicles (EVs) are distinguished in many cases by their substantial flexibility. Harnessing this flexibility, however, requires a precise characterization of its timing and degree. Current approaches to flexibility characterization tend to be limited either by the complexity of their representation or their inability to capture aggregate flexibility across multiple vehicles. In this paper, we present the reduction potential matrix, a novel metric capturing fleet-level EV load flexibility while being both straightforward to calculate and intuitive to interpret. We use the metric to quantify flexibility for two operationally distinct commercial groups: freight vehicles and transit buses. While we find that both vehicle groups have substantial flexibility, its timing, magnitude, and duration varies across the groups. We describe how this variability translates into variation in the each group's role as a grid resource, and conclude with a discussion of how system planners, fleet operators, and other stakeholders can use the novel metric to cultivate symbiosis between vehicles and the grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EVs-at-RISC: A Secure and Resilient Interoperable SCM Control System Architecture for Electric Vehicle’s-at-Scale (Final Technical Report)

The EVs-at-RISC project was a five-year research, development, and demonstration initiative to create foundational tools for utility-scale fleet aggregation and Smart Charge Management (SCM) of Electric Vehicles (EV), Electric Vehicle Charging Infrastructure (EVCI), and related Distributed Energy Resources (DER). Rather than seeking to develop and demonstrate highly perfected SCM algorithms and control strategies, this project instead focused on creating foundational software solutions that enable unprecedented digital interoperability across the communications technologies and vendor platforms used to manage EV , EVCI, and DER, as well as existing energy management infrastructure operated by utilities, grid operators, and aggregators. This project then extends these novel interoperability capabilities to develop and deploy powerful middleware abstractions across grid edge networks and EVCI/DER fleet aggregations incorporating modern software tools and best practices, such as CI/CD, to bring the immense capabilities of infrastructure-as-code and policy-as-code to modern grid edge network environments. This addresses the foremost systemic issues preventing realization of any net operational benefits from scaled deployment of behind-the-meter EV, EVCI, and DER assets in electric power grids and markets today. The results of this approach and project unlock massive potential for new SCM capabilities to be easily prototyped, evaluated, and deployed at-scale within the existing grid edge network infrastructure and EVCI/DER technology ecosystem. The EVs-at-RISC project achieves this by extending Open Field Message Bus (OpenFMB), a conceptual model for digital interoperability and distributed intelligence in traditional front-of-meter utility SCADA networks, validating our hypothesis that OpenFMB could be similarly used to solve systemic digital interoperability issues in behind-the-meter environments and unlock real-world utility-scale SCM capabilities without requiring any new proprietary vendor solutions or significant infrastructure reconfiguration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Fuels Campaign Time-at-Temperature Irradiation Campaign and Post-Irradiation Examination Plan

With increasing per capita energy consumption and rapidly growing energy consumption predicted for data centers, the US faces challenges in meeting projected energy demands. The current administration is attempting to accelerate the deployment of new nuclear construction by providing significant investments in advanced nuclear and by modernizing regulatory approaches for the licensing new reactors. However, enabling extended power uprates (EPUs) for the current nuclear reactor fleet would provide a shorter-term solution to better calibrate near-term energy generation capacity to the ever-growing energy demands of the modern era. One pathway to achieve power uprates is to increase the operational window by reassessing fuel safety limits around anticipated transients. Existing light-water reactors (LWRs) utilize a targeted operational window with well-defined operational efficiencies, yet this window is also often bound by conservative safety limits that result in suboptimal operational performance. For example, the operation of the existing fleet is highly constrained by safeguards to operation related to anticipated operational occurrences (AOOs), which are moderate-frequency transients expected with a frequency greater than 0.01 per reactor-year. These AOOs include temperature excursions where the critical heat flux for the system is exceeded, resulting in a departure from nucleate boiling (DNB) at the cladding surface. This DNB event is a thermohydraulic condition that, with current conservative fuel safety limits, results in the fuel rods being classified as “failed,” meaning that the cladding may not be returned to service.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Fuels Campaign Time-at-Temperature Irradiation Campaign and Post-Irradiation Examination Plan

With increasing per capita energy consumption and rapidly growing energy consumption predicted for data centers, the US faces challenges in meeting projected energy demands. The current administration is attempting to accelerate the deployment of new nuclear construction by providing significant investments in advanced nuclear and by modernizing regulatory approaches for the licensing new reactors. However, enabling extended power uprates (EPUs) for the current nuclear reactor fleet would provide a shorter-term solution to better calibrate near-term energy generation capacity to the ever-growing energy demands of the modern era. One pathway to achieve power uprates is to increase the operational window by reassessing fuel safety limits around anticipated transients. Existing light-water reactors (LWRs) utilize a targeted operational window with well-defined operational efficiencies, yet this window is also often bound by conservative safety limits that result in suboptimal operational performance. For example, the operation of the existing fleet is highly constrained by safeguards to operation related to anticipated operational occurrences (AOOs), which are moderate-frequency transients expected with a frequency greater than 0.01 per reactor-year. These AOOs include temperature excursions where the critical heat flux for the system is exceeded, resulting in a departure from nucleate boiling (DNB) at the cladding surface. This DNB event is a thermohydraulic condition that, with current conservative fuel safety limits, results in the fuel rods being classified as “failed,” meaning that the cladding may not be returned to service.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

CMIP6-based Multi-model Hydropower Projection over the Conterminous US, Version 1.1

This dataset presents a suite of hydropower projections for the conterminous United States (CONUS), derived from multiple downscaled and bias-corrected Global Climate Models (GCMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). The CMIP6 GCMs are downscaled using either statistical (DBCCA) or dynamical (RegCM) approaches, based on two meteorological reference datasets (Daymet and Livneh). The resulting downscaled precipitation, temperature, and wind speed data are then used to drive two calibrated hydrologic models (VIC and PRMS), enabling simulations of projected future hydrologic responses across the CONUS. Simulated total runoff is subsequently employed to drive two hydropower models (WMP, now implemented as mosartwmpy-power, and WRES) to evaluate how climate change may affect future hydropower production for both federal and non-federal hydropower fleets. This dataset was developed to support the SECURE Water Act Section 9505 Assessment for the U.S. Department of Energy (DOE) Water Power Technologies Office (WPTO). For further details, see Broman et al. (2024), Thurber et al. (2024), Kao et al. (2022), and Zhou et al. (2023).

Voisin, Nathalie [Pacific Northwest National Labor↗

Design of a SMART Valve Testbed for Nuclear Thermal Dispatch

By the year 2050, the United States aims to achieve net-zero carbon emissions. To achieve this target, the licensing of the Light Water Reactor (LWR) fleet has been extended for 20 more years. To stay economically competitive with other power sources such as renewable and fossil-fuel power plants, the U.S. Department of Energy has introduced a plan to modernize the existing LWR fleet and diversify the revenue stream. One of the plans is to dispatch thermal energy to endothermic industrial processes. SMART valves will play an important role in this initiative by efficiently balancing the load by regulating valves in a coordinated manner while monitoring the thermal-hydraulic systems to enhance safety and maintain the integrity of the power plant. This research aims to develop a facility to test the coordinated control algorithm and produce various test results for training the monitoring system. The constructed facility is capable of simulating various operational and accidental scenarios by coordinating all the valves (positions) and pump (flowrate). The facility is developed with an Internet of Things (IoT)-based custom system and a python-based valve position control and coordination mechanism. It has achieved stable sensor outputs, pump control, and coordinated valve regulation in all three valves with minimum obstruction in the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗