Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality structure material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Clinical Evaluation of Normalized Metal Artifact Reduction in kVCT Using MVCT Prior Images (MVCT-NMAR) for Radiation Therapy Treatment Planning

Purpose: To evaluate the metal artifacts in diagnostic kilovoltage computed tomography (kVCT) images of patients that are corrected by use of a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images: MVCT-NMAR. Methods and Materials: MVCT-NMAR was applied to images from 5 patients: 3 with dual hip prostheses, 1 with a single hip prosthesis, and 1 with dental fillings. The corrected images were evaluated for visualization of tissue structures and their interfaces and for radiation therapy dose calculations. They were compared against the corresponding images corrected by the commercial orthopedic metal artifact reduction algorithm in a Phillips CT scanner. Results: The use of MVCT images for correcting kVCT images in the MVCT-NMAR technique greatly reduces metal artifacts, avoids secondary artifacts, and makes patient images more useful for correct dose calculation in radiation therapy. These improvements are significant, provided the MVCT and kVCT images are correctly registered. The remaining and the secondary artifacts (soft tissue blurring, eroded bones, false bones or air pockets, CT number cupping within the metal) present in orthopedic metal artifact reduction corrected images are removed in the MVCT-NMAR corrected images. A large dose reduction was possible outside the planning target volume (eg, 59.2 Gy to 52.5 Gy in pubic bone) when these MVCT-NMAR corrected images were used in TomoTherapy treatment plans without directional blocks for a prostate cancer patient. Conclusions: The use of MVCT-NMAR corrected images in radiation therapy treatment planning could improve the treatment plan quality for patients with metallic implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine learning analysis of perovskite oxides grown by molecular beam epitaxy

Reflection high-energy electron diffraction (RHEED) is a ubiquitous in situ molecular beam epitaxial (MBE) characterization tool. Although RHEED can be a powerful means for crystal surface structure determination, it is often used as a static qualitative surface characterization method at discrete intervals during a growth. A full analysis of RHEED data collected during the entirety of MBE growths is made possible using principle component analysis (PCA) and $\textit{k}$-means clustering to examine significant boundaries that occur in the temporal clusters grouped from RHEED data and identify statistically significant patterns. This process is applied to data from homoepitaxial SrTiO 3 growths, heteroepitaxial SrTiO 3 grown on scandate substrates, BaSnO 3 films grown on SrTiO 3 substrates, and LaNiO 3 films grown on SrTiO 3 substrates. We report this analysis may provide additional insights into the surface evolution and transitions in growth modes at precise times and depths during growth, and that video archival of an entire RHEED image sequence may be able to provide more insight and control overgrowth processes and film quality.

36 MATERIALS SCIENCE↗

A Denoising Autoencoder for Improved Kikuchi Pattern Quality and Indexing in Electron Backscatter Diffraction

The rapid collection and indexing of electron diffraction patterns as produced via electron backscatter diffraction (EBSD) has enabled crystallographic orientation and structural determination, as well as additional property-determining strain and dislocation density information with increasing speed, resolution, and efficiency. Pattern indexing quality is reliant on the noise of the collected electron diffraction patterns, which is often convoluted by sample preparation and data collection parameters. EBSD acquisition is sensitive to many factors and thus can result in low confidence index (CI), poor image quality (IQ), and improper minimization of fit, which can result in noisy datasets and misrepresent the microstructure. In an attempt to enable both higher speed EBSD data collection and enable greater orientation fit accuracy with noisy datasets, an image denoising autoencoder was implemented to improve pattern quality. Here, we show that EBSD data processed through the autoencoder results in a higher CI, IQ, and a more accurate degree of fit. In addition, using denoised datasets in HR-EBSD cross correlative strain analysis can result in reduced phantom strain from erroneous calculations due to the increased indexing accuracy and improved correspondence between collected and simulated patterns.

36 MATERIALS SCIENCE↗

Microstructure and defects probed by Raman spectroscopy in lithium niobate crystals and devices

Raman microprobe applied on LiNbO{sub 3} (LN) crystals and derived materials or devices is shown to be a tool to detect either local variations or changes of the whole structure. Position, width, or intensity of one Raman line can be used as markers of a structural change. Indeed, each Raman line can be assigned to a peculiar ionic motion and is differently sensitive to application of strain, temperature change, and electric field. Some vibrational modes are especially associated to the site of Li ion, or Nb ion, or still oxygen octahedron, so that they can be affected by the introduction of dopant ion on one or another site. Therefore, Raman Spectroscopy (RS) can be used as a site spectroscopy to describe the mechanism of doping incorporation in the LN lattice, allowing the optimization of some linear and non-linear optical properties according to the dopant concentration and substitution site. The composition or the content of non-stoichiometry related defects could be derived from the width of some lines. Any damage or local disorder can be detected by a line broadening. The quality or preservation of the structure after chemical treatment, or laser pulses, can be thus checked. The structure of ion-implanted or proton-exchanged wave-guides and periodically poled lithium niobate as well can be imaged from frequency shift or intensity change of some lines. RS is thus a useful way to control the structure of LN and/or to optimize the preparation parameters and its properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of grain-boundary geometry and pores morphology in dense and porous cubic zirconia polycrystals

Highlights: • Cubic zirconia sinters were investigated in three dimensions using dual-beam FEGSEM. • The 3D-EBSD technique was successfully applied to non-conductive ceramics. • New sample preparation approach to automated 3D-EBSD was proposed. • Grain boundary microstructures were reconstructed from inverse pole figure maps. • Pore microstructures were reconstructed from image quality maps. - Abstract: Three-dimensional electron backscatter diffraction technique was used for the visualization of grain boundary geometry and pore morphology in cubic zirconia. A set of four samples sintered under different conditions was investigated. Specimens which were characterized by energy dispersive spectroscopy and X-ray diffraction were entirely composed of cubic phase. Investigations of boundaries and pore structures were carried out in a dual-beam scanning electron microscope. For each sample, a volume of 1000 μm{sup 3} was investigated. The analysis of grain boundary networks reconstructed from inverse pole figure maps revealed a strong dependence between grain boundary density and sample preparation parameters. Sintering also affects the size and distribution of pores. The total number of grains analyzed varied from 17 to 357 and the calculated volume of cavities from 0.01% to 21%. This paper shows the application of three-dimensional crystallographic orientation analysis to characterize the microstructure of yttria stabilized zirconia ceramics.

36 MATERIALS SCIENCE↗

Deep generative learning of magnetic frustration in artificial spin ice from magnetic force microscopy images

Increasingly large datasets of microscopic images with nanoscale resolution facilitate the development of machine learning methods to identify and analyze subtle physical phenomena embedded within the images. In this work, microscopic images of honeycomb lattice spin-ice samples serve as datasets from which we automate the calculation of net magnetic moments and directional orientations of spin-ice configurations. In the first stage of our workflow, machine learning models are trained to accurately predict magnetic moments and directions within spin-ice structures. Variational Autoencoders (VAEs), an emergent unsupervised deep learning technique, are employed to generate high-quality synthetic magnetic force microscopy (MFM) images and extract latent feature representations, thereby reducing experimental and segmentation errors. The second stage of proposed methodology enables precise identification and prediction of frustrated vertices and nanomagnetic segments, effectively correlating structural and functional aspects of microscopic images. This facilitates the design of optimized spin-ice configurations with controlled frustration patterns, enabling potential on-demand synthesis.

36 MATERIALS SCIENCE↗

Multi-Task Learning of Scanning Electron Microscopy and Synthetic Thermal Tomography Images for Detection of Defects in Additively Manufactured Metals

One of the key challenges in laser powder bed fusion (LPBF) additive manufacturing of metals is the appearance of microscopic pores in 3D-printed metallic structures. Quality control in LPBF can be accomplished with non-destructive imaging of the actual 3D-printed structures. Thermal tomography (TT) is a promising non-contact, non-destructive imaging method, which allows for the visualization of subsurface defects in arbitrary-sized metallic structures. However, because imaging is based on heat diffusion, TT images suffer from blurring, which increases with depth. We have been investigating the enhancement of TT imaging capability using machine learning. In this work, we introduce a novel multi-task learning (MTL) approach, which simultaneously performs the classification of synthetic TT images, and segmentation of experimental scanning electron microscopy (SEM) images. Synthetic TT images are obtained from computer simulations of metallic structures with subsurface elliptical-shaped defects, while experimental SEM images are obtained from imaging of LPBF-printed stainless-steel coupons. MTL network is implemented as a shared U-net encoder between the classification and the segmentation tasks. Results of this study show that the MTL network performs better in both the classification of synthetic TT images and the segmentation of SEM images tasks, as compared to the conventional approach when the individual tasks are performed independently of each other.

36 MATERIALS SCIENCE↗

Photoluminescence Characterization of ZnO Thin Films Grown by RF- Sputtering

This article presents photoluminescence (PL) characterization of ZnO thin films deposited by radio-frequency magnetron sputtering method on sapphire and n-type Si (100) substrates. PL measurements were carried out at room temperature to investigate the energy band gaps and optical quality of the ZnO thin films. In order to draw a specific picture of surface morphology of ZnO thin films, atomic force microscope images were taken. All the results were compared to the results obtained from the bulk ZnO sample. The results revealed that the energy band gap of ZnO thin films grown on n-type Si (100) is higher than ZnO on sapphire. However, energy band gap of bulk ZnO is higher compared to both ZnO on n-type Si (100) and sapphire (Al{sub 2}O{sub 3}). This is probably due to the crystalline quality because good crystallinity increases the radiation recombination and hence increase the intensity of the NBE emission.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-temperature synthesis of graphene on nickel foil by microwave plasma chemical vapor deposition

Microwave plasma chemical vapor deposition (MPCVD) was employed to synthesize high quality centimeter scale graphene film at low temperatures. Monolayer graphene was obtained by varying the gas mixing ratio of hydrogen and methane to 80:1. Using advantages of MPCVD, the synthesis temperature was decreased from 750 deg. C down to 450 deg. C. Optical microscopy and Raman mapping images exhibited that a large area monolayer graphene was synthesized regardless of the temperatures. Since the overall transparency of 89% and low sheet resistances ranging from 590 to 1855 {Omega}/sq of graphene films were achieved at considerably low synthesis temperatures, MPCVD can be adopted in manufacturing future large-area electronic devices based on graphene film.

36 MATERIALS SCIENCE↗

WE-EF-207-07: Dual Energy CT with One Full Scan and a Second Sparse-View Scan Using Structure Preserving Iterative Reconstruction (SPIR)

Purpose: Conventional dual energy CT (DECT) reconstructs CT and basis material images from two full-size projection datasets with different energy spectra. To relax the data requirement, we propose an iterative DECT reconstruction algorithm using one full scan and a second sparse-view scan by utilizing redundant structural information of the same object acquired at two different energies. Methods: We first reconstruct a full-scan CT image using filtered-backprojection (FBP) algorithm. The material similarities of each pixel with other pixels are calculated by an exponential function about pixel value differences. We assume that the material similarities of pixels remains in the second CT scan, although pixel values may vary. An iterative method is designed to reconstruct the second CT image from reduced projections. Under the data fidelity constraint, the algorithm minimizes the L2 norm of the difference between pixel value and its estimation, which is the average of other pixel values weighted by their similarities. The proposed algorithm, referred to as structure preserving iterative reconstruction (SPIR), is evaluated on physical phantoms. Results: On the Catphan600 phantom, SPIR-based DECT method with a second 10-view scan reduces the noise standard deviation of a full-scan FBP CT reconstruction by a factor of 4 with well-maintained spatial resolution, while iterative reconstruction using total-variation regularization (TVR) degrades the spatial resolution at the same noise level. The proposed method achieves less than 1% measurement difference on electron density map compared with the conventional two-full-scan DECT. On an anthropomorphic pediatric phantom, our method successfully reconstructs the complicated vertebra structures and decomposes bone and soft tissue. Conclusion: We develop an effective method to reduce the number of views and therefore data acquisition in DECT. We show that SPIR-based DECT using one full scan and a second 10-view scan can provide high-quality DECT images and accurate electron density maps as conventional two-full-scan DECT.

60 APPLIED LIFE SCIENCES↗

A facile route to high-purity BN nanoplates with ultraviolet cathodoluminescence emissions at room temperature

Highlights: • We present a novel and simple approach to great-scale fabrication of BN nanoplates. • The as-synthesized products are extensively characterized. • The formation mechanism of BN nanoplates are elucidated based on experimental observations. • A growth model was proposed according to our experimental observations and analysis. • BN nanoplates’ CL performance envisions its applications such as UV emitters. - Abstract: We present a novel and notably simple approach to fabricate BN nanoplates in large scale employing ammonia borane as a single-source precursor. The structure and chemical composition of the as-synthesized products are extensively characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HRTEM) and electron energy-loss spectroscopy (EELS). XRD analysis indicates that the products are hexagonal BN crystal. SEM images confirm that the BN nanoplates have an average diameter of about 200 nm and thickness of tens of nanometers. HRTEM results illustrate the BN nanoplates to be single-crystals. EELS result suggests the nanoplates are composed of boron and nitride elements. The formation mechanism of the BN nanoplates has been elucidated based on our experimental observations, and a growth model has been proposed accordingly. Cathodoluminescence spectroscopic analysis is performed and strong ultraviolet (UV) emissions are detected. Our method provides a simple route towards the large-scale fabrication of high-quality BN nanoplates, for which various promising applications such as compact UV emitters can be envisioned.

36 MATERIALS SCIENCE↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1 %, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "hits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. Preliminary experiments show that the presence of the fluorescent probe does not affect the nucleation process or the quality of the X-ray data obtained.

Pusey, Marc L.↗

Deep Learning Super-Resolution X-Ray Computed Tomography Algorithms for Additive Manufacturing

Industrial X-ray computed tomography (XCT) is a nondestructive method for inspection and characterization of additively manufactured (AM) materials and parts. In practice, the resolution of XCT can be limited by factors such as detector binning, restricted field of view for large-scale objects, system blur, motion during scanning, and acquisition settings. These limitations can reduce the detectability of critical flaws such as pores, cracks, and lack of fusion. Super-resolution (SR) techniques offer a promising solution for improving the effective resolution and image quality of XCT reconstructions without the need for expensive hardware upgrades or laborious, time-consuming scans. In particular, deep learning-based SR methods have garnered attention in recent years as powerful tools for reconstructing high-resolution volumes from low-resolution inputs. In this work, a novel deep learning-based SR method is proposed for XCT scans of AM parts, and compared against several existing state-of-the-art (SOTA) methods. The proposed method, Simurgh-SR, is built on the pre-existing Simurgh framework and consists of a 2.5D U-Net trained to map low-quality inputs containing noise and artifacts to high-quality reconstructions characterized by higher flaw contrast, better noise texture, and reduced artifacts. The experimental results demonstrate superior performance of Simurgh-SR in performing 4× SR on real industrial XCT scans of thick 316L components, enhancing the structural similarity score and peak signal-to-noise ratio (>7dB) compared to the LR counterpart while improving the F1-score for flaw detection by more than 2.3× when compared to alternative SOTA SR methods. This improvement enables more accurate and significantly faster characterization of metal AM components. Additionally, Simurgh-SR was trained for both 2X and 4X SR and performs effectively at both levels, enabling the use of a single model for various SR factors.

Rahman, Obaid [ORNL] (ORCID:0000000277810840)↗

WE-FG-207B-03: Multi-Energy CT Reconstruction with Spatial Spectral Nonlocal Means Regularization

Purpose: Multi-energy computed tomography (MECT) is an emerging application in medical imaging due to its ability of material differentiation and potential for molecular imaging. In MECT, image correlations at different spatial and channels exist. It is desirable to incorporate these correlations in reconstruction to improve image quality. For this purpose, this study proposes a MECT reconstruction technique that employes spatial spectral non-local means (ssNLM) regularization. Methods: We consider a kVp-switching scanning method in which source energy is rapidly switched during data acquisition. For each energy channel, this yields projection data acquired at a number of angles, whereas projection angles among channels are different. We formulate the reconstruction task as an optimziation problem. A least square term enfores data fidelity. A ssNLM term is used as regularization to encourage similarities among image patches at different spatial locations and channels. When comparing image patches at different channels, intensity difference were corrected by a transformation estimated via histogram equalization during the reconstruction process. Results: We tested our method in a simulation study with a NCAT phantom and an experimental study with a Gammex phantom. For comparison purpose, we also performed reconstructions using conjugate-gradient least square (CGLS) method and conventional NLM method that only considers spatial correlation in an image. ssNLM is able to better suppress streak artifacts. The streaks are along different projection directions in images at different channels. ssNLM discourages this dissimilarity and hence removes them. True image structures are preserved in this process. Measurements in regions of interests yield 1.1 to 3.2 and 1.5 to 1.8 times higher contrast to noise ratio than the NLM approach. Improvements over CGLS is even more profound due to lack of regularization in the CGLS method and hence amplified noise. Conclusion: The proposed ssNLM method for kVp-switching MECT reconstruction can achieve high quality MECT images.

60 APPLIED LIFE SCIENCES↗

Revealing transient powder-gas interaction in laser powder bed fusion process through multi-physics modeling and high-speed synchrotron x-ray imaging

Laser powder bed fusion (LPBF) is an emerging metal additive manufacturing process. The gas-driven powder motions in laser powder bed fusion have significant influence on the build quality. However, the transient powder-gas interaction has not been well understood due to the challenges in quantitative experiment measurements. In this work, the powder-gas interaction for a single pulse laser illuminating on the powder bed is studied. We establish a multi-physics model to simulate the complex liquid/gas flow as well as the gas-driven powder motions, which is substantiated by high-speed synchrotron x-ray imaging. We identify and quantify four characteristic modes of powder-gas interaction in LPBF. The motion of a powder is controlled by one or multiple interaction modes collectively. As revealed by simulations and confirmed by experiments, powders can merge into the molten pool from its rim, be ejected at different divergence angles (powder spattering), or dive into the molten pool to cause significant molten pool fluctuation. Overall, our results provide insights toward the driving forces controlling the dynamic powder behavior, which pave the way for reducing structure defects during the build process.

36 MATERIALS SCIENCE↗

Imaging moiré flat bands in three-dimensional reconstructed WSe 2 /WS 2 superlattices

Moiré superlattices in transition metal dichalcogenide (TMD) heterostructures can host novel correlated quantum phenomena due to the interplay of narrow moiré flat bands and strong, long-range Coulomb interactions. However, microscopic knowledge of the atomically reconstructed moiré superlattice and resulting flat bands is still lacking, which is critical for fundamental understanding and control of the correlated moiré phenomena. Here we quantitatively study the moiré flat bands in three-dimensional (3D) reconstructed WSe 2 /WS 2 moiré superlattices by comparing scanning tunnelling spectroscopy (STS) of high-quality exfoliated TMD heterostructure devices with ab initio simulations of TMD moiré superlattices. A strong 3D buckling reconstruction accompanied by large in-plane strain redistribution is identified in our WSe 2 /WS 2 moiré heterostructures. STS imaging demonstrates that this results in a remarkably narrow and highly localized K-point moiré flat band at the valence band edge of the heterostructure. A series of moiré flat bands are observed at different energies that exhibit varying degrees of localization. Our observations contradict previous simplified theoretical models but agree quantitatively with ab initio simulations that fully capture the 3D structural reconstruction. Furthermore, our results reveal that the strain redistribution and 3D buckling in TMD heterostructures dominate the effective moiré potential and the corresponding moiré flat bands at the Brillouin zone K points.

36 MATERIALS SCIENCE↗

Ghost imaging second harmonic generation microscopy

Second harmonic generation (SHG) microscopy is useful for visualizing interfaces and sub-structures within a wide range of materials due to the propensity for SHG to occur in non-centrosymmetric environments. However, since SHG is a nonlinear process generally necessitating small focal sizes for higher peak powers, a raster scanning approach is usually needed to build an SHG image over a significant sample size. While raster scanning is effective, there is a cost in terms of the time needed to acquire the image and, also, some materials cannot withstand the higher optical intensities within the small focal volume. As such, we describe a SHG microscopy approach based on ghost imaging (GI), which enables imaging data to be collected in parallel rather than sequentially as in raster scanning techniques. We experimentally demonstrate the approach and combine GI-SHG with compressive sensing to make further substantial gains in reducing the amount of sampling required for image reconstruction. Furthermore, GI-SHG is shown to have significant advantages for imaging in highly scattering environments, partly because GI is a background-free approach requiring spatial correlations between photons that travel two paths, with one path entirely devoid of sample interaction. This basic property of GI means that only the photons that travel unimpeded through the sample preserve the spatial correlations needed to reconstruct the image, while more scattered photons do not contribute to the overall GI signal. Finally, we compare the image quality and sampling properties of three different reconstruction algorithms used for compressive sensing.

47 OTHER INSTRUMENTATION↗