Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedence analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Magnetic potential based formulation for linear and non-linear 3D RF sheath simulation

Abstract This paper reports a new numerical scheme to simulate the radio-frequency (RF) induced RF sheath, which is suitable for a large 3D simulation. In the RF sheath boundary model, the tangential component of the electric field ( E t ) is given by the gradient of a scalar electric field potential. We introduce two additional scalar potentials for the tangential components of the magnetic field, which effectively impose the normal electric displacement ( D n ) on the plasma sheath boundary condition via in-homogeneous Neumann boundary condition and constrain the tangential electric field on the surface as curl-free ( ∇ × E t = 0 ). In our approach, the non-linear sheath impedance is formulated as a natural extension of the large thickness (or asymptotic) sheath limit ( D n = 0 ), allowing for handling both asymptotic and non-linear regimes seamlessly. The new scheme is implemented using the Petra-M finite element method analysis framework and is verified with simulations in the literature. The significance of non-linearity is discussed in various plasma conditions. An application of this scheme to asymptotic RF sheath simulation on the WEST ICRF antenna side limiters is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Review on Solid State Batteries: Life Cycle Perspectives

This report briefly reviews the characteristics of solid-state batteries (SSBs) and the life-cycle analysis (LCA) studies that have been completed for SSBs. Compared with conventional lithium-ion batteries (LIBs), SSBs offer improved safety and potentially higher energy density — both enabled by replacing liquid electrolytes with solid electrolytes and using lithium metal anodes. Several challenges impede the commercialization of SSBs, primarily related to the stability of the interface between the solid electrolyte and the electrodes. Several options are under consideration for SSB electrolyte and cathode chemistries. As a result, the production processes for these components and the corresponding battery packs are still under development and can differ significantly from those used for conventional LIB pack production. A robust comparison of SSBs with LIBs through LCA is important to analyze the environmental benefits and challenges associated with this alternative battery system. While the literature provides only a few LCA studies focused on SSBs, with significant uncertainty in their life-cycle inventories (LCIs), those studies collectively suggest that solid electrolyte manufacturing is the major environmental hotspot, followed by cathode and anode production.

25 ENERGY STORAGE↗

Measurement of stability diagrams in the IOTA ring at Fermilab

Nonlinear focusing elements can enhance the stability of particle beams in high-energy colliders through Landau Damping, by means of the tune spread which is introduced. Here we discuss an experiment at Fermilab's Integrable Optics Test Accelerator (IOTA) which investigates the influence of nonlinear focusing elements, such as octupoles, on the beam’s transverse stability. In this experiment, we employ an anti-damper, an active transverse feedback system, as a controlled mechanism to induce coherent beam instability. By utilizing the anti-damper we can examine the impact of a nonlinear focusing element on the beam's transverse stability. The stability diagram, a tool used to determine the system's stability, is measured using a recently demonstrated method at the LHC. The experiment at IOTA adds insight towards this stability diagram measurement method by supplying a reduced machine impedance to investigate the machine impedance’s effect on the stability diagram, as well as by aiming to map out the full stability diagram by using a large phase range of the anti-damper. From this experiment in IOTA, we present the first results of stability diagram analysis with varying octupole currents.

43 PARTICLE ACCELERATORS↗

An Impedance Humidity Sensor Based on CVD Grown WSe 2 2D Films

2D materials-based planar devices have been sought after for gas and humidity sensor applications owing to their high sensitivity due to their ultrathin nature and increased surface area. Herein, 2D WSe 2 films-based planner devices were fabricated to evaluate their performance for potential application in humidity sensors. The structure and morphology of the WSe 2 sensing films were studied by Raman spectroscopy, photoluminescence, optical microscopy, and scanning electron microscopy (SEM) techniques. The relative humidity-dependent sensing performances of the 2D WSe 2 films were evaluated using current–voltage (I–V), relative impedance, and complex total impedance (electrochemical impedance spectroscopy, EIS) techniques. This sensor showed a very stable and repeatable performance investigated over the period of 18 months. The response and recovery times of the WSe 2 -based impedance sensors were found to be 40 and 30 s, respectively. The WSe 2 sensor exhibits a 2 ± 1% minimum hysteresis at a lower humidity level (50% RH) and around 8 ± 2% maximum hysteresis at relative humidity level (70% RH). This value of hysteresis is in the acceptable range during the initial investigation of any material to explore its potential for application in humidity sensors. The density functional theory (DFT) analysis was performed with the interaction from water molecules of the WSe 2 sample for a better understanding of the sensing mechanism of devices.

2D- WSe2↗

Adaptive Extremum Seeking Control Based LCL Filter Resonant Frequency Online Estimation

The LCL filter has been widely used in the grid-tied inverter systems. However, the resonance of the LCL filter can reduce the system stability margin and the control performance. Moreover, the grid impedance variations can lead to the drift of the resonant frequency, which can further worsen the system robustness. Thus, it is important to know the actual resonant frequency of the LCL filter. In this letter, an adaptive extremum seeking control (AESC) based estimation scheme is proposed to estimate the resonant frequency of the LCL filter online. Further by injecting a high-frequency (HF) signal into the inverter output voltage, the AESC scheme can identify the extremum of the LCL filter amplitude response, i.e., resonant peak. The amplitude of injection signal is adaptive based on the inverter HF response, which can address the tradeoff between the dynamic response and inverter output current quality. Most importantly, compare to other method, the proposed scheme has very low computational complexity, which minimizes the burden to the normal inverter controller operation. Stability analysis is given in this letter, and experimental studies are conducted to validate the effectiveness of the proposed scheme.

42 ENGINEERING↗

Comparative Analysis of Pendulum and Flywheel Power Take-Off Mechanisms for Wave Energy Conversion

Here, this study compares three power-take-off (PTO) mechanisms for wave energy converters—a flywheel -type pitch resonator and two pendulum variants (normal and inverted)—all designed to fit within a fixed envelope. Performance is assessed via linear frequency-domain models and bi-conjugate impedance matching under a representative sea state. The inverted-pendulum PTO achieves 27.9% of the incident wave energy, versus 16.5% for the normal pendulum and 4.2% for the flywheel—that is, 6.6 × and 3.9 × improvements, respectively. These gains arise because pendulum-based systems generate higher torque for a given buoy motion and maintain impedance matching across a wider frequency band. Parametric studies of mass, pendulum arm length, spring stiffness, generator friction, and motor constant quantify the impact of key design choices on power output. By locating the pendulum pivot near the buoy's center of gravity and positioning the center of rotation below the COG, surge–pitch coupling is improved and energy transfer is further boosted.

Keow, Alicia Li Jen [Sandia National Laboratories ↗

Species-Selective Detection of Volatile Organic Compounds by Ionic Liquid-Based Electrolyte Using Electrochemical Methods

The detection of volatile organic compounds (VOCs) is an important topic for environmental safety and public health. However, the current commercial VOC detectors suffer from cross-sensitivity and low reproducibility. In this work, we present species-selective detection for VOCs using an electrochemical cell based on ionic liquid (IL) electrolytes with features of high selectivity and reliability. The voltammograms measured with the IL-based electrolyte absorbing different VOCs exhibited species-selective features that were extracted and classified by linear discriminant analysis (LDA). The detection system could identify as many as four types of VOCs, including methanol, ethanol, acetone, formaldehyde, and additional water. A mixture of methanol and formaldehyde was detected as well. The sample required for the VOCs classification system was 50 μL, or 1.164 mmol, on average. The response time for each VOC measurement is as fast as 24 s. The volume of VOCs such as formaldehyde in solution could also be quantified by LDA and electrochemical impedance spectroscopy techniques, respectively. The system showed a tunable detection range for 1.6 and 16% (w/v) CH 2 O solution by adjusting the composition of the electrolyte. The limit of detection was as low as 1 μL. For the 1.6% CH 2 O solution, the linearity calibration range was determined to be from 5.30 to 53.00 μmol with a limit of detection at 0.53 μmol. The mechanisms for VOCs determination and quantification are also thoroughly discussed. Finally, it is expected that this work could provide a new insight into the concept of electrochemical detection of VOCs with machine learning analysis and be applied to both VOCs gas monitoring and fluid detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insight into the Solid Electrolyte Interphase Formation in Bis(fluorosulfonyl)Imide Based Ionic Liquid Electrolytes

The formation of the solid electrolyte interphase (SEI) in an ionic liquid electrolyte of 0.5 m lithium bis(fluorosulfonyl)imide (LiFSI) in 1-ethyl-3-methylimidazolium bis(fluorosulfonyl)imide at high cell voltages (1.7–1.9 V) is investigated in ordered mesoporous carbon (OMC) based Li metal cells using an operando small-angle neutron scattering (SANS) technique coupled with electrochemical impedance spectroscopy and ex situ X-ray photoelectron spectroscopy (XPS). It is demonstrated that discharging the OMC Li metal cells to ≈2 V and holding the cell voltage constant induces a rapid current increase with time, confirming extensive reduction and SEI formation. XPS analysis reveals that LiF is formed at open cell voltage (OCV), which is attributed to the carbenes generated at the lithium negative electrode because of its reaction with EMIm cation diffusing to and initiating the reaction with FSI - anions at the carbon positive electrode. It is confirmed that the chemical reaction at OCV and electrochemical reduction at high cell voltage of the FSI - anion plays a protective role against EMIm cation co-intercalation into the carbon positive electrode during the initial discharge. Operando SANS studies also suggest that slight differences occur in the surface composition and reaction mechanism as a function of cell voltage.

1-ethyl-3- methylimidazolium bis(fluorosulfonyl)im↗

Electrochemical recovery of Nd using liquid metals (Bi and Sn) in LiCl-KCl-NdCl 3

Highly efficient recovery of Nd into liquid metals of Bi and Sn was achieved in molten LiCl-KCl-NdCl 3 electrolyte at 773–973 K by leveraging the strong interactions of Nd with liquid metals. Based on the emf measurements of Nd-Sn and Nd-Bi alloys, the activity values of Nd were determined as low as 1.1–5.8×10 –13 in both liquid metals at 973 K while the solubility of Nd was found to be 1.46 mol% in Sn and 5.65 mol% in Bi. Both liquid metals demonstrated high round-trip coulombic efficiencies (>99.3%) during deposition-removal cycles of 10–50 mA cm –2 and high recovery capacity up to approximately 20 mol% Nd beyond the solubility limit. In addition, a high Nd recovery yield (84–90%) with respect to the applied charge was confirmed based on chemical analysis of electrolysis products in Bi after constant current electrolysis (–50 mA cm –2 ) at 873–973 K. Overpotentials during the Nd deposition process were attributed to charge-transfer and mass-transport resistances based on the current-potential curve and electrochemical impedance spectroscopy. The charge-transfer kinetics of Nd deposition into liquid metals was facile with high exchange current densities at ~220 mA cm –2 . Finally, the exceptionally high recovery efficiency for Nd in the molten chloride is thought to result from strong chemical interactions (i.e., low activity) of Nd in liquid metals that encourage one-step reduction, i.e., Nd 3+ + 3e → Nd(in Bi or Sn) by effectively suppressing side reaction pathways from multivalent states (Nd 2+ and Nd 3+ ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithium Dendrite-Free Li 7 N 2 I-LiOH Solid Electrolytes for High Energy Lithium Batteries

All-solid-state lithium batteries (ASSLBs) hold great potential to improve the safety and energy density of today’s lithium-ion batteries by using non-flammable inorganic solid electrolytes. Solid electrolytes (SEs) are believed to prevent Li dendrite growth because of high mechanical strength and high Li+ transference numbers. Significant advances in SE have been achieved, among which, Li7La3Zr2O12 (LLZO) and Li2S–P2S5 (LPS) are the most promising SEs for bulk-type solid-state lithium batteries because of high ionic conductivities (>10-4 S/cm2). However, in contrast to our expectations, the growth of lithium dendrites is not suppressed but is facilitated in LLZOs and LPSs regardless of dopants, porosity, and crystallinity of the electrolytes. Despite the unity Li transference number and over two-times of shear modulus than that of Li metal, the critical current densities for Li plating and stripping in these SEs are less than 1.0 mA cm-2, which is one-fourth to one-tenth of that in liquid electrolytes at room temperature. The incompatibility between LLZO and LPS with Li metal seriously limits the energy density of all-solid-state batteries. The mechanism for lithium dendrite formation and growth in SEs are still disputable. Lack of understanding of the Li dendrite formation mechanism seriously impeded the development of solid-state lithium batteries. The development of the criterion for Li dendrite suppression is essential for the success of solid electrolyte lithium batteries. In this project, a criterion for Li dendrite suppression will be developed through thermodynamics and kinetics analysis of lithium dendrite nucleation/growth, which will guide the solid-state electrolyte design. Li7N2I-LiOH, Li5NI2-LiOH and Li3YCl6 solid electrolyte with high ionic conductivity and low electronic conductivity were used to validate the criterion for lithium dendrite suppression. Different surface modifications were also explored to enhance the dendrite suppression capability of SSEs.

25 ENERGY STORAGE↗

Broad Applicability of Electrochemical Impedance Spectroscopy to the Measurement of Oxygen Nonstoichiometry in Mixed Ion and Electron Conductors

Oxygen non-stoichiometry is a fundamental feature of mixed ion and electron conductors (MIECs). In this work a general electrochemical method for determining non-stoichiometry in thin film MIECs, via measurement of the chemical capacitance, is demonstrated using ceria and ceria-zirconia (Ce 0.8 Zr 0.2 O 2-δ ) as representative materials. A.C. impedance data are collected from both materials at high temperature (750-900 °C) under reducing conditions with oxygen partial pressure (pO 2 ) in the range 10-13 to 10-20 atm. Additional measurements of ceria-zirconia films are made under relatively oxidizing conditions with pO 2 in the range 0.2 to 10 -4 atm and temperatures of 800-900 °C. Under reducing conditions, the impedance spectra are described by a simple circuit in which a resistor is in series with a resistor and capacitor in parallel, and thickness dependent measurements are used to resolve the capacitance into interfacial and chemical terms. Under more oxidizing conditions, the impedance spectra (of Ce 0.8 Zr 0.2 O 2-δ ) reveal an additional diffusional feature, which enables determination of the ionic resistance of the film in addition to the capacitance, and hence the transport properties. A generalized mathematical formalism is presented for recovering the non-stoichiometry from the chemical capacitance, without recourse to defect chemical models. The ceria non-stoichiometry values are in good agreement with literature values determined by thermogravimetric measurements but display considerably less scatter and are collected on considerably shorter timescales. Here, the thermodynamic analysis of Ce 0.8 Zr 0.2 O 2-δ corroborates earlier findings that introduction of Zr into ceria enhances its reducibility.

08 HYDROGEN↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SA508 low alloy steel to 316L stainless steel dissimilar metal joint made by powder metallurgy hot isostatic pressing

Joining ferritic SA508 low alloy steel (LAS) and austenitic 316 L stainless steel (SS) via powder metallurgy hot isostatic pressing (PM-HIP) was evaluated as an alternative method to welding. This study investigated the mechanical and microstructural evolutions of the bimetallic interface under different joint designs and heat treatments. Here, the direct joining of dissimilar metal alloys by PM-HIP method resulted in two designs: 1) powder SA508 to solid bar 316 L (P508–B316L) and 2) powder 316 L solid bar SA508 (P316L-B508). In both cases, P508–B316L and P316L-demonstrated satisfactory tensile strength, however, high hardness and severe depreciation in toughness were located on the bimetallic interface. The mechanisms responsible for the detrimental mechanical properties were verified. Large oxides were observed in P508–B316L due to the prior powder boundary (PPB) oxides present in SA508 powder. The intense sensitization occurred from the formation of M 23 C 6 carbides, consequently from the slow cooling after PM-HIP in P316L-B508. Post-HIP heat treatments were explored to reduce the distance of carbide formation; however, the heat treatment could not eliminate the carbides. The experimental results were compared to the diffusion couple simulation as a function of carbide formation with distance. The analysis also showed the high hardness at the bimetallic interface was primarily contributed by solid solution strengthening. In conclusion, the direct joining of P316L-B508 and P508–B316L via PM-HIP was deemed to be unfeasible, and a transitional material is necessary to impede the diffusion of carbon.

316L stainless Steel↗

Non-Electricity Based Renewable Fuels: Theory and Computation for Solar Thermochemical Hydrogen

Dominated by photovoltaics and wind, current renewable energy sources generate mostly electricity, but 80% of the global final energy consumption occurs in form of fuels. Therefore, direct solar fuel generation would be a major breakthrough for the energy transition. Solar thermochemical hydrogen (STCH) is one of the very few potential routes towards scalable renewable fuels, but currently suffers from lack of an oxide working material that could optimally perform energy conversion within the thermodynamic boundary conditions. Theory and computation can contribute in two distinct ways, through materials search and discovery, but also by providing detailed mechanistic models for specific systems so to advance our understanding of possible design strategies. To enable high-throughput materials screening, we developed a defect graph neural network (dGNN) machine learning approach,[1] which accelerates the prediction of defect formation energies by replacing the tedious density functional theory (DFT) supercell calculations for all possible defect sites. This approach enables high-throughput database screening of oxides, which was integrated with thermodynamic modeling to extract the reduction entropies as additional selection criterion for STCH. Once potential candidate materials are identified, detailed models can guide materials design by predicting performance characteristics. One challenge is to quantitatively predict thermochemical equilibria at high concentrations when the redox active defects start to interact with each other, thereby impeding the formation of additional defects. Introducing a model for the free energy of defect interaction, parametrized on the basis of DFT data, we simulated the complete STCH redox cycle for (Sr,Ce)MnO3 alloys, achieving near-quantitative agreement with experimental data.[2] The analysis of these simulations reveals how defect interactions diminish the reduction entropy and H2 yield, suggesting to include these interactions in design considerations. Finally, we revisit the popular van't Hoff method for analyzing reduction enthalpies and entropies. This method is not ideal, as it involves a temperature-dependent convolution of gas-phase and solid-state entropies, causing uncertainties in the same order of magnitude as the physical quantities of interest. To avoid this problem, we suggest a simple alternative approach which can be applied to experimental and simulated data alike.

first-principles calculations↗

Axial magnetic flux amplification in Hall-magnetohydrodynamic simulations of externally magnetized z-pinches

It is shown that externally magnetized gas-puff z-pinches under compression can exhibit robust axial flux amplification under suitable axial boundary conditions. This effect relies upon the Hall term in the generalized Ohm's law to generate azimuthal currents in the presence of a driving axial electric field. Under dynamic compression, the total current tends to flow in a mostly force-free boundary layer, separating the predominately azimuthal field outside the layer and the predominately axial field inside the layer. The effect only appears to occur if the axial boundaries allow for outflow or absorption of electromagnetic energy. The effect is mitigated by imposing either periodic or conducting axial boundary conditions. A semi-analytic equilibrium analysis agrees with steady-state solutions of the time-dependent electron-magnetohydrodynamic equations and provides an estimate of the scaling of the boundary layer as well as suggesting a scenario for the formation of the boundary layer. When operative, the effect can significantly impede plasma compression due to the increase in axial flux that diffuses into the pre-compressed plasma or through the presence of conductors that inhibit movement of the generated axial flux. Several facilities have noted unusual implosion behavior in z-pinch experiments with applied axial fields that does not appear to be explainable within the standard magnetohydrodynamic model. In conclusion, it is suggested that these experiments can be explained by the axial flux amplification and concentration effect

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence for large baryonic feedback at low and intermediate redshifts from kinematic Sunyaev-Zel’dovich observations with ACT and DESI photometric galaxies

Recent advances in cosmological observations have provided an unprecedented opportunity to investigate the distribution of baryons relative to the underlying matter. In this work, we show that the gas is more extended than the dark matter, and the amount of baryonic feedback at $z \lesssim 1$ disfavors low-feedback models such as that of state-of-the-art hydrodynamical simulation IllustrisTNG compared with high-feedback models such as that of the original Illustris simulation. This has important implications for bridging the gap between theory and observations and understanding galaxy formation and evolution. Furthermore, a better grasp of the baryon-dark matter link is critical to future cosmological analyses, which are currently impeded by our limited knowledge of baryonic feedback. Here, we measure the kinematic Sunyaev-Zel'dovich (kSZ) effect from the Atacama Cosmology Telescope (ACT), stacked on the luminous red galaxy (LRG) sample of the Dark Energy Spectroscopic Instrument (DESI) imaging survey. This is the first analysis to use photometric redshifts for reconstructing galaxy velocities. Due to the large number of galaxies comprising the DESI imaging survey, this is the highest signal-to-noise stacked kSZ measurement to date: we detect the signal at 13$σ$, finding strong evidence that the gas is more spread out than the dark matter, as well as a preference for larger feedback compared to some commonly used state-of-the-art hydrodynamical simulations. Here, our work opens up the possibility of recalibrating large hydrodynamical simulations using the kSZ effect. In addition, our findings highlight the importance of properly accounting for baryonic feedback with future surveys such as LSST through direct probes such as the kSZ, and shed light on long-standing enigmas in astrophysics, such as the “missing baryon” problem.

79 ASTRONOMY AND ASTROPHYSICS↗

Challenges and Solutions for Real-Time Phasor Modeling of Large-scale Distribution Network with High PV Penetration

The conversion process of a practical large-scale feeder data from a quasi-static time series (OpenDSS) model into a real-time phasor model (ePHASORSIM in Opal-RT) is discussed in the paper. The process is implemented using an open source Python software. Previous reported implementations for the conversion process lead to several errors when applied to a larger-scale system such as the one considered here. Hence in this work, we describe the common issues in this conversion and propose a customized solution to enhance the efficiency of the conversion and reduce the complexity in the process. A quantitative validation of the enhanced conversion process is presented in this work using an actual high PV penetration feeder model that consists of 2230 buses, and using actual load and PV profile data. After a detailed analysis, this customized conversion software will be made available as an open source tool and is expected to be helpful for researchers who want to pursue a similar conversion. Solutions to various observed issues such as identifying the lines due to islanded network, representation of full impedance model of transformer/lines as sequential models, complexity in the representation of single phase buses/lines as three phase buses/lines to make it compatible with the simulator platform are discussed. Comparison of power flow and time series simulation results obtained from both OpenDSS and ePHASORsim models show very low errors, validating the accuracy of the proposed conversion process.

14 SOLAR ENERGY↗