Design and installation of a solar-powered hot-water system
Package includes performance specifications, design drawings, hazard analysis, and installation for complete solar-powered hot-water system.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Package includes performance specifications, design drawings, hazard analysis, and installation for complete solar-powered hot-water system.
Package consists of installation, operation and maintenance manuals for four commercial solar energy subsystems, including flat plate solar collector pebble bed thermal-storage. Manual gives design information, sizing data, specification drawings, and other material for subsystem.
Installation package for solar-powered hot-air system contains such information as operation and maintenance manuals, hardware brochures, schematics, operating mode descriptions, and drawings.
Installation of commerical solar-heating system at two story, three bedroom house in New Hampshire is described in 65 page report. System collectors are integrated part of building replacing conventional roofing or siding. Report also includes general description of system, its operation and guidelines, orientation and references.
Simple tool based on principle of automobile oil wrench slips over cylindrical thread-on baffle to install or remove it from baffle assembly. Tool consists of curled metal sheet brazed onto handgrip. Handgrip is adapted to be driven by wrench, ratchet, extension, torque wrench, or some other convenient tool. Clockwise twist of handgrip, tightens metal sheet around baffle to advance it into threaded joint. Counterclockwise twist loosens sheet for repositioning or tool removal.
Special handling sleeve, key to method of installing thrust bearings, was developed for assembling bearings on shaft of low-pressure oxygen turbo-pump. Method eliminates cooling and vacuum-drying steps which saves time, while also eliminating possibility of corrosion formation. Procedure saves energy because it requires no liquid nitrogen for cooling shaft and no natural gas or electric power for operating vacuum oven.
The requirements and concepts for the installation of various types of mission and subsystem equipment on large area space systems are discussed.
Included are the system performance specifications, system design drawings, hazard analysis and other information necessary to evaluate the design and install the system.
A description is given of the solar energy hot water system installed in the Days Inns of America, Inc., at Anderson, South Carolina. The building is a low-rise, two-story 114-room motel. The solar system was designed to provide 40 percent of the total hot water demand. The collector is a flat plate, liquid with an area of 750 square feet. Operation of this system was begun in November 1977, and has performed flawlessly for one year.
The Solar system was installed into a new building and was designed to provide 79% of the estimated annual space heating load and 59% of the estimated annual potable hot water requirement. The collectors are flat plate, liquid manufactured by Reynolds Metals Company and cover a total area of 2344 square feet. The storage medium is water inhibited with NALCO 2755 and the container is an underground, unpressurized steel tank with a capacity of 5000 gallons. This report describes in considerable detail the solar heating facility and contains detailed drawings of the completed system.
An aid concept known as the PIDA (Payload Installation and Deployment Aid) is presented as a way to assist the RMS (Remote Manipulator System) by relaxing the accuracy required during payload handling in the payload bay. The aid concept was designed and developed to move payloads through a prescribed path between the confined quarters of the payload bay and a position outside the critical maneuvering area of the Orbiter. A description of the design requirements and the modes of operation of the various functions of the deployment and the docking mechanisms are covered.
Information used to evaluate the design of a solar heating, cooling, and domestic hot water system is given. A conventional heat pump provides summer cooling items as the design data brochure, system performance specification, system hazard analysis, spare parts list, and detailed design drawings. A solar system is installed in a single-family dwelling at Akron, Ohio, and at Duffield, Virginia.
The specification used to install a broadband coaxial cable communication system to support remote terminal operations on the Crew Activity Planning system at the Lyndon B. Johnson Space Center are reported. The system supports high speed communications between a Harris Slash 8 computer and one or more Sanders Graphic 7 displays.
The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.
The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.
The Langley Research Center has conducted an experimental program on a model of the F-18 airplane to determine the performance of nonaxisymmetric nozzles relative to the aircraft's baseline axisymmetric nozzle. The performance of a single expansion ramp (ADEN) and two-dimensional convergent-divergent (2-D C-D) nozzle were compared to the baseline axisymmetric nozzles. The effects of vectoring and reversing were also studied. Performance of a modified YF-17 airplane with the ADEN nozzle was also estimated. The results of this investigation indicate that nonaxisymmetric nozzles can be installed on a twin engine fighter airplane with equal or better performance than axisymmetric nozzles. The nonaxisymmetric nozzles also offer potential for innovative and improved aircraft maneuver through thrust vectoring and reversing. The YF-17/ADEN flown as a technology demonstrator would have reduced performance compared to an unmodified YF-17. However, on an equal aircraft weight basis, performance would essentially be equivalent. This study also showed that the YF-17 can serve as a testbed to validate nonaxisymmetric nozzle technology.
The relationship between the amount of cooling air flow and the corresponding flow pressure difference across an aircraft engine was investigated in flight and on the ground. The flight test results were consistent with theory, but indicated a significant installation leakage problem. A ground test blower system was used to identify and reduce the leakage. The correlation between ground test cell determined engine orifice characteristics and flight measurements showed good agreement if the engine pressure difference was based on total pressure rather than static pressure.
The results of two-dimensional wedge non-axisymmetric nozzle (2D-AIN) tests to determine its performance relative to the baseline axisymmetric nozzle using an F-18 jet effects wind tunnel model are presented. Configurations and test conditions simulated forward thrust-minus drag, thrust vectoring/induced lift, and thrust reversing flight conditions from Mach .6 to 1.20 and attack angles up to 10 degrees. Results of the model test program indicate that non-axisymmetric nozzles can be installed on a twin engine fighter aircraft model with equivalent thrust minus drag performance as the baseline axisymmetric nozzles. Thrust vectoring capability of the non-axisymmetric nozzles provided significant jet-induced lift on the nozzle/aftbody and horizontal tail surfaces. Thrust reversing panels deployed from the 2D-AIN centerbody wedge were very effective for static and inflight operation