Search NASA⌕ Search

SEARCH · Search NASA

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Embedded Sensors in Additively Manufactured Silicon Carbide

Silicon carbide (SiC) components are being considered for a wide range of nuclear applications due to their high-temperature strength retention, low neutron absorption, chemical inertness, and dimensional stability under neutron irradiation. However, machining and joining of SiC components have traditionally limited its application to relatively simple geometries. Recent work has demonstrated additive manufacturing of complex, high-purity, crystalline SiC components using a combination of binder jet printing and densification via chemical vapor infiltration (CVI). The process lends itself to embedding of fuel, absorbers, moderators, and sensors at strategic locations within a component. The latter could allow for enhanced in situ performance monitoring of limiting fuel temperatures, self-shielded neutron flux, and potentially spatially distributed strain within complex SiC components if sensors can be successfully embedded during CVI. This work describes (1) methods for embedding sensors; (2) thermodynamic analyses and material compatibility testing for identifying sensors capable of surviving high temperatures and exposure to hydrogen and hydrogen chloride during CVI; and (3) nuclear applications for embedded sensors, including potential failure modes during fabrication and during reactor operation. Molybdenum-sheathed thermocouples were successfully embedded in a complex SiC component, whereas niobium-sheathed high-temperature irradiation-resistant thermocouples started to drift as soon as the reactant gases were introduced and ultimately failed during CVI due to severe constrained expansion, potentially resulting from niobium hydride formation in the low-temperature region of the CVI system. Optical fibers were successfully embedded in SiC, but further work is needed to protect the fragile fiber leads after their protective coatings are removed during CVI.

thermocouples↗

Advanced Facility Design and AI/ML Enabled Safeguards to Establish Secure, Economical Recycling of Fast Reactor Fuels (Final Scientific/Technical Report)

The project, "Advanced Facility Design and AI/ML Enabled Safeguards to Establish Secure, Economical Recycling of Fast Reactor Fuels," represents a significant advancement in nuclear fuel recycling technology. It integrates cutting-edge multimodal sensor fusion, machine learning (ML), and digital twin (DT) technologies to address challenges in material safeguarding, process optimization, and regulatory compliance for pyroprocessing facilities. This research has significantly enhanced the understanding of pyrochemical fuel recycling processes by developing innovative tools and methodologies. The Multimodal Safeguards Monitoring Unit (MSMU) combines electroanalytical techniques, Raman spectroscopy, and differential thermal analysis (DTA) to enable high-fidelity, near-real-time material accountancy measurements. Machine learning techniques, such as Long Short-Term Memory (LSTM) autoencoders, are utilized to detect anomalies in material balances and sensor data, improving the reliability of safeguards monitoring. Additionally, digital twin technology has been established to provide real-time system-level monitoring and diagnostics, integrating physics-based models with sensor data to optimize process safety and efficiency.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Material gauge factor of directional electric potential drop sensors for creep monitoring

Directional electric potential drop measurements can be exploited for in-situ monitoring of creep in metals. The sensor monitors the variation in the ratio of the resistances measured simultaneously in the axial and lateral directions using a square-electrode configuration. This method can efficiently separate the mostly isotropic common part of the resistivity variation caused by reversible temperature variations from the mostly anisotropic differential part caused by direct geometrical (size and shape) and indirect material (resistivity) effects of creep. Similarly to ordinary strain gauges, the relative sensitivity of the sensor is defined as a gauge factor that can be approximated as the sum of geometrical and material parts. Initially, subtle material changes produce weak electric anisotropy via reversible and irreversible piezoresistivity due to elastic and plastic strains, respectively. At high temperature, much stronger irreversible resistivity changes also occur due to preferentially aligned clusters of cavities developing along grain boundaries approximately perpendicular to the applied stress and subsequent cracks forming between these cavities. The ensuing electric anisotropy is detected by the directional sensor. Although the material effects remain smaller than the geometrical ones up to the initiation of preferentially oriented cracks, later the material gauge factor sharply increases and close to rupture can reach a value of more than 10.

36 MATERIALS SCIENCE↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solvent effect on polystyrene surface roughness on top of QCM sensor

Quartz Crystal Microbalance (QCM) has been used as a basis for many chemical sensors and biosensor. Its sensitivity to mass change which can detect a mass change on its surface down to sub ng/cm2 is one of its interesting aspects. Another interesting feature is its ability to work in liquid environment. However, there are many aspects which influence QCM sensor properties in contact with liquid. One of the aspects is surface roughness of the matrix layer where on top of it a biological sensitive layer will be immobilized. One of matrix layers in the immobilizing biological sensitive layer was polystyrene. Polystyrene was coated on the QCM sensor by using the spin coating method. During the coating process, polystyrene was solved using non-polar solvent. It is known that the physical and chemical properties of the solvent affect a transition process from soluble polymer becoming rigid polymer layer. In this work, we show that polystyrene solved in chloroform has a higher surface roughness compare to one solved in toluene, xylene, or tetrahydrofuran. Surface roughness of the polystyrene coating were measured using a non-contact profilometer. However, we also found that there is no difference on the electrical impedance of the QCM sensor coated with polystyrene resulted from differing solvent when the sensor was in contact with air and water. Thus, all of the mentioned solvent can be used to solve the polystyrene as a coating material for QCM sensor without affecting the electrical performance of the sensor, but the choice of the solution can be used as a simple method to control the difference roughness of the polystyrene coating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Signals from fluorescent materials on the surface of silicon micro-strip sensors

For the High-Luminosity Upgrade of the Large Hadron Collider at CERN, the ATLAS Inner Detector will be replaced with a new, all-silicon tracker (ITk). In order to minimise the amount of material in the ITk, circuit boards with readout electronics will be glued onto the active area of the sensor. Several adhesives, investigated to be used for the construction of detector modules, were found to become fluorescent when exposed to UV light. These adhesives could become a light source in the high-radiation environment of the ATLAS detector. The effect of fluorescent material covering the sensor surface in a high-radiation environment has been studied for a silicon micro-strip sensor using a micro-focused X-ray beam. By positioning the beam parallel to the sensor surface and pointing it both inside the sensor and above the sensor surface inside the deposited glue, the sensor responses from direct hits and fluorescence can be compared with high precision. This contribution presents a setup to study the susceptibility of silicon strip sensors to light contamination from fluorescent materials and shows their impact on the noise and fake signal rate of a sensor operated in a high-radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ATOMIC FORCE LITHOGRAPHY OF NANO MICROFLUIDIC CHANNELS FOR VERIFICATION AND MONITORING IN AQUEOUS SOLUTIONS

The growing interest in the physics of fluidic flow in nanoscale channels, as well as the possibility for high sensitive detection of ions and single molecules is driving the development of nanofluidic channels. The enrichment of charged analytes due to electric field-controlled flow and surface charge/dipole interactions along the channel can lead to enhancement of sensitivity and limits-of-detection in sensor instruments. Nuclear material processing, waste remediation, and nuclear non-proliferation applications can greatly benefit from this capability. Atomic force microscopy (AFM) provides a low-cost alternative for the machining of disposable nanochannels. The small AFM tip diameter (< 10 nm) can provide for features at scales restricted in conventional optical and electron-beam lithography. This work presents preliminary results on the fabrication of nano/microfluidic channels on polymer films deposited on quartz substrates by AFM lithography.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Printable sensors for explosive detonation

Here, we report the development of an organic thin film transistor (OTFT) based on printable solution processed polymers and employing a quantum tunnelling composite material as a sensor to convert the pressure wave output from detonation transmission tubing (shock tube) into an inherently amplified electronic signal for explosives initiation. The organic electronic detector allows detection of the signal in a low voltage operating range, an essential feature for sites employing live ordinances that is not provided by conventional electronic devices. We show that a 30-fold change in detector response is possible using the presented detector assembly. Degradation of the OTFT response with both time and repeated voltage scans was characterised, and device lifetime is shown to be consistent with the requirements for on-site printing and usage. The integration of a low cost organic electronic detector with inexpensive shock tube transmission fuse presents attractive avenues for the development of cheap and simple assemblies for precisely timed initiation of explosive chains.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

pH-Mediated Colorimetric and Luminescent Sensing of Aqueous Nitrate Anions by a Platinum(II) Luminophore@Mesoporous Silica Composite

Increased levels of nitrate (NO 3 – ) in the environment can be detrimental to human health. Herein, we report a robust, cost-effective, and scalable, hybrid material-based colorimetric/luminescent sensor technology for rapid, selective, sensitive, and interference-free in situ NO 3 – detection. These hybrid materials are based on a square-planar platinum(II) salt [Pt(tpy)Cl]PF6 (tpy = 2,2';6',2''-terpyridine) supported on mesoporous silica. The platinum salt undergoes a vivid change in color and luminescence upon exposure to aqueous NO 3 – anions at pH ≤ 0 caused by substitution of the PF6– anions by aqueous NO 3 – . This change in photophysics of the platinum salt is induced by a rearrangement of its crystal lattice that leads to an extended Pt···Pt···Pt interaction, along with a concomitant change in its electronic structure. Furthermore, incorporating the material into mesoporous silica enhances the surface area and increases the detection sensitivity. A NO 3 – detection limit of 0.05 mM (3.1 ppm) is achieved, which is sufficiently lower than the ambient water quality limit of 0.16 mM (10 ppm) set by the United States Environmental Protection Agency. The colorimetric/luminescence of the hybrid material is highly selective to aqueous NO 3 – anions in the presence of other interfering anions, suggesting that this material is a promising candidate for the rapid NO 3 – detection and quantification in practical samples without separation, concentration, or other pretreatment steps.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring of Actinide Concentrations in Molten LiCl-KCl Salt using Alpha Spectroscopy: Final Progress Report

This project addresses the need for real time monitoring of actinide concentrations for spent fuel reprocessing utilizing alpha spectroscopy. This project specifically focuses on spent fuel reprocessing with the pyroprocessing technique that uses high temperature molten salt. Pyroprocessing uses molten salt such as lithium chloride and potassium chloride to separate out uranium and plutonium from spent fuel. To prevent any possible diversion of high purity plutonium in this process, monitoring of the actinide concentrations within the refinery are essential for safeguards and non-proliferation efforts. Alpha spectroscopy enables the identification and quantification of actinide isotopic concentrations. However, current assay methods involving intrusive sampling and ex-suit measurement require weeks to provide accurate information. A near real-time and in-situ measurement system is required to quickly quantify actinide isotopic concentrations within the salt. Semiconductor radiation detectors provide a compact, high energy resolution option for completing these measurement needs. Silicon carbide (SiC) has been shown to operate effectively at high temperatures and high chemical stability in the molten salt environment. 4H-SiC Schottky diode alpha particle detectors were fabricated and tested to determine their alpha spectroscopy capabilities. The detectors need to operate at the elevated temperatures, survive the molten salt environment, be radiation hard, and have sufficient energy resolution under all these conditions to determine isotopic concentrations. Along with the detector, a method of producing samples of the actinides in the salt is required. To produce a thin film of the actinides on the detector, which is a necessity for alpha spectroscopy, electrodeposition can be used. Electrodeposition uses an electric potential difference to selectively deposit uranium or other actinides from the salt using an anode and cathode. Deposition of the material directly onto the sensor would produce a thin film of material that would enable materials accountability measurements to be taken in real time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Working Group Report: Sensors

Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In addition the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges.

HEP↗

Sensor Compendium: A Snowmass Whitepaper

Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In addition the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural analysis of molten materials by a remote fiber optic Raman sensor

This study presents a novel in situ high-temperature fiber optic Raman probe that enables the study of the physical properties and structure of molten samples at temperatures up to 1400 °C. To demonstrate the functionality of the high-temperature fiber optic Raman probe, different composition mold fluxes were evaluated in this report. The Raman spectra at flux molten temperature were successfully collected and analyzed. A deconvolution algorithm was employed to identify peaks in the spectra associated with the molecular structure of the components in each sample. Here, the experimental results demonstrate that the composition-dependent Raman signal shift can be detected at high temperatures, indicating that molten materials analysis using a high-temperature Raman system shows significant promise. This flexible and reliable high-temperature Raman measurement method has great potential for various applications, such as materials development, composition and structure monitoring during high-temperature processing, chemical identification, and process monitoring in industrial production.

47 OTHER INSTRUMENTATION↗