Search NASA⌕ Search

SEARCH · Search NASA

Results for “multi frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Investigation of radar discrimination of sea ice

The ability of radar to discriminate sea ice types and their thickness was studied. Radar backscatter measurements at 400 MHz (multi-polarization) and 13.3 GHz (VV polarization) obtained from NASA Earth Resources Aircraft Program Mission 126 were analyzed in detail. The scatterometer data were separated into seven categories of sea ice according to age and thickness as interpreted from stereo aerial photographs. The variations of radar backscatter cross-section with sea ice thickness at various angles are presented at the two frequencies. There is a reversal of angular character of radar return from sea ice less than 18 cm thick at the two frequencies. Multi-year ice (sea ice greater than 180 cm thick) gives strongest return at 13.3 GHz. First-year ice (30 cm to 90 cm thick) gives strongest return at 400 MHz. Open water can be differentiated at both the frequencies. Four-polarization 16.5 GHz radar imagery was also obtained. Open water and three categories of sea ice can be identified on the images. The results of the imagery analysis are consistent with the radar scatterometer results.

Parashar, S. K.↗

A sophisticated, multi-channel data acquisition and processing system for high frequency noise research

A sophisticated, multi-channel computerized data acquisition and processing system was developed at the NASA LeRC for use in noise experiments. This technology, which is available for transfer to industry, provides a convenient, cost-effective alternative to analog tape recording for high frequency acoustic measurements. This system provides 32-channel acquisition of microphone signals with an analysis bandwidth up to 100 kHz per channel. Cost was minimized through the use of off-the-shelf components. Requirements to allow for future expansion were met by choosing equipment which adheres to established industry standards for hardware and software. Data processing capabilities include narrow band and 1/3 octave spectral analysis, compensation for microphone frequency response/directivity, and correction of acoustic data to standard day conditions. The system was used successfully in a major wind tunnel test program at NASA LeRC to acquire and analyze jet noise data in support of the High Speed Civil Transport (HSCT) program.

Hall, David G.↗

Multifrequency Models of Black Hole Photon Rings from Low-luminosity Accretion Disks

Images of black holes encode both astrophysical and gravitational properties. Detecting highly lensed features in images can differentiate between these two effects. We present an accretion disk emission model coupled to the Adaptive Analytical Ray Tracing (AART) code that allows a fast parameter space exploration of black hole photon ring images produced from synchrotron emission from 10 to 670 GHz. As an application, we systematically study several disk models and compute their total flux density, average radii, and optical depth. The model parameters are chosen around fiducial values calibrated to general relativistic magnetohydrodynamic (GRMHD) simulations and observations of M87*. For the parameter space studied, we characterize the transition between optically thin and thick regimes and the frequency at which the first photon ring is observable. Our results highlight the need for careful definitions of photon ring radius in the image domain, as in certain models the highly lensed photon ring is dimmer than the direct emission at certain angles. We find that at low frequencies the ring radii are set by the electron temperature, while at higher frequencies the magnetic field strength plays a more significant role, demonstrating how multifrequency analysis can also be used to infer plasma parameters. Lastly, we show how our implementation can qualitatively reproduce multifrequency black hole images from GRMHD simulations when adding time variability to our disk model through Gaussian random fields. This approach provides a new method for simulating observations from the Event Horizon Telescope and the proposed Black Hole Explorer space mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Mesoscale Convective Systems Tracking Method Intercomparison (MCSMIP): Application to DYAMOND Global km‐Scale Simulations

Abstract Global kilometer‐scale models represent the future of Earth system modeling, enabling explicit simulation of organized convective storms and their associated extreme weather. Here, we comprehensively evaluate tropical mesoscale convective system (MCS) characteristics in the DYAMOND (DYnamics of the atmospheric general circulation modeled on non‐hydrostatic domains) simulations for both summer and winter phases. Using 10 different feature trackers applied to simulations and satellite observations, we assess MCS frequency, precipitation, and other key characteristics. Substantial differences (a factor of 2–3) arise among trackers in observed MCS frequency and their precipitation contribution, but model‐observation differences in MCS statistics are more consistent across trackers. DYAMOND models are generally skillful in simulating tropical mean MCS frequency, with multi‐model mean biases ranging from −2%–8% over land and −8%–8% over ocean (summer vs. winter). However, most DYAMOND models underestimate MCS precipitation amount (23%) and their contribution to total precipitation (17%). Biases in precipitation contributions are generally smaller over land (13%) than over ocean (21%), with moderate inter‐model variability. While models better simulate MCS diurnal cycles and cloud shield characteristics, they overestimate MCS precipitation intensity and underestimate stratiform rain contributions (up to a factor of 2), particularly over land, albeit observational uncertainties exist. Additionally, models exhibit a wide range of precipitable water in the tropics compared to reanalysis and satellite observations, with many models showing exaggerated sensitivity of MCS precipitation intensity to precipitable water. The MCS metrics developed here provide process‐oriented diagnostics to guide future model development.

54 ENVIRONMENTAL SCIENCES↗

Technical Report on Waveform Fit Metrics for Global Models

The new WAVEFORMS Initiative in the Ground-based Nuclear Detonation Detection (GNDD) program includes an increased emphasis on the development of Earth models and methods to predict entire seismic and acoustic waveforms more accurately. In general, this increased emphasis is predicated on the need to better characterize seismic events and provide improved model-based discrimination between event types including earthquakes and explosions. More specifically, while current moment tensor inversion methods tend to work well for larger events (M>~4) using tuned 1-D Earth models, the development of state-of-the-art 3-D models and methods is required for the prediction of shorter period waves over large areas for discrimination of smaller events. There is no standard metric for model-based waveform prediction accuracy used in the waveform modeling/inversion community. However, there are several popular waveform misfit definitions; and minimizing the corresponding objective functions is the goal of waveform inversion. Some example misfit definitions employed for adjoint waveform tomography include measures of simple travel time differences (e.g. Tape et al., 2010), cross-correlation travel time differences (e.g. Luo and Schuster, 1991), multi-taper frequency dependent methods (e.g. Lei et al., 2020), time-frequency phase misfit functions (e.g. Fichtner 2010; Rodgers et al., 2022), normalized cross-correlation methods (e.g. Tao et al., 2018), and others. In some cases, these misfit definitions also involve complicated weighting schemes and summations over multiple frequency bands making it difficult to duplicate the misfit measurement with alternative models and datasets. Although each of the misfit definitions mentioned above are useful for developing waveform models, the actual misfit values are not usually meaningful outside of a given project, model, and/or dataset. Therefore, it is difficult to understand and communicate model performance for predicting waveforms and comparing to other models and/or new model iterations with a different dataset. Therefore, there is a need for a generalized method for evaluating overall model performance that is independent from the specific misfit chosen to develop the waveform models that is also intuitive and meaningful. In this report, we describe a new metric we refer to as ‘Percent of Correlated Signal’. The following sections describe and demonstrate the metric with a case study event and a more rigorous test using a random selection of globally distributed events. While the focus here is on global tomography models, the metric is meant to applicable to regional ‘wiggle-for-wiggle’ waveform models/studies as well.

58 GEOSCIENCES↗

Micromechanical Switches on GaAs for Microwave Applications

In this presentation, we describe the fabrication of micro-electro-mechanical system (MEMS) devices, in particular, of low-frequency multi-element electrical switches using SiO2 cantilevers. The switches discussed are related to micromechanical membrane structures used to perform switching of optical signals on silicon substrates. These switches use a thin metal membrane which is actuated by an electrostatic potential, causing the switch to make or break contact. The advantages include: superior isolation, high power handling capabilities, high radiation hardening, very low power operations, and the ability to integrate onto GaAs monolithic microwave integrated circuit (MMIC) chips.

Randall, John N.↗

A Multi-Function AAA Algorithm Applied to Frequency-Dependent Line Modeling: Preprint

We present a new multi-input rational approximation algorithm (MIAAA) and illustrate its advantages respect to the popular Vector Fitting (VF) algorithm using examples of approximations of admittance matrices discussed in a very recent paper and by the creators of VF. We show that not only MIAAA outperforms VF in terms of achieving better accuracy using a smaller number of poles, but also has no numerical issues to achieve convergence. In contrast to VF, MIAA is not sensitive to the location of input sample points and it does not require good estimates for the location of the desired approximation poles.

97 MATHEMATICS AND COMPUTING↗

Multi-axis Heterodyne Interferometry at MHz Frequencies: a Short-Arm Measurement Demonstration for LISA with Off-The-Shelf Hardware

We report the design, construction, and operation of a multi-axis heterodyne interferometry (MAHI) system operating at MHz heterodyne frequencies, which provides a testbed for technologies to be used in the Laser Interferometer Space Antenna (LISA) space-based gravitational wave mission. The system was calibrated for measurement of the piston, pitch, and yaw of a three-axis piezo-actuated mirror, giving measured calibration values that closely match those predicted by a simulation based on Gaussian beam tracing. The piston sensitivity of the MAHI system in the LISA band was measured to be below 10pmHz 1/2 10pmHz1/2 for frequencies above 4 mHz and below 1pmHz 1/2 1pmHz1/2 for frequencies above 35 mHz. The sensitivity is limited above 2 Hz by the mechanical vibrations of the apparatus and below 1 mHz by dimensional changes caused by temperature fluctuations. Evidence points towards scattered light as the limiting noise source at intermediate frequencies. The angular sensitivity of the MAHI system was measured to be close to or below 10nradHz 1/2 10nradHz1/2 for frequencies above 4 mHz and below 1nradHz 1/2 1nradHz1/2 for frequencies above 100 mHz. Noise budgets for both length and angle were determined, indicating the areas in which improvements must be made in order to reach increased sensitivity. The current operating sensitivity already provides a useful testbed for LISA technologies and a potential blueprint for future ground segment equipment.

Fulda, P.↗

Numerical Simulation of Waves Driven by Plasma Currents Generated by Low-Frequency Alfven Waves in a Multi-Ion Plasma

When multi-ion plasma consisting of heavy and light ions is permeated by a lowfrequency Alfien (LFA) wave, the EXB and the polarization drifts of the different ion species and the electrons could be quite different. The relative drifts between the charged-particle species drive waves, which energize the plasma. Using 2.5-D particle-in-cell simulations, we study this process of wave generation and its nonlinear consequences in terms of acceleration and heating plasma. Specifically we study the situation for LFA wave frequency being lower than the heavyion cyclotron frequency in a multi-ion plasma. We impose such a wave to the plasma assuming that its wavelength is much larger than that of the waves generated by the relative drifts. For better understanding, the LFA-wave driven simulations are augmented by those driven by initialized ion beams.

Singh, Nagendra↗

Method for Balancing Detector Output to a Desired Level of Balance at a Frequency

A multi-gas sensor is provided which modulates a polarized light beam over a broadband of wavelengths between two alternating orthogonal polarization components. The two orthogonal polarization components of the polarization modulated beam are directed along two distinct optical paths. At least one optical path contains one or more spectral discrimination elements, with each spectral discrimination element having spectral absorption features of one or more gases of interest being measured. The two optical paths then intersect, and one orthogonal component of the intersected components is transmitted and the other orthogonal component is reflected. The combined polarization modulated beam is partitioned into one or more smaller spectral regions of interest where one or more gases of interest has an absorption band. The difference in intensity between the two orthogonal polarization components is then determined in each partitioned spectral region of interest as an indication of the spectral emission/absorption of the light beam by the gases of interest in the measurement path. The spectral emission/absorption is indicative of the concentration of the one or more gases of interest in the measurement path. More specifically, one embodiment of the present invention is a gas filter correlation radiometer which comprises a polarizer, a polarization modulator, a polarization beam splitter, a beam combiner, wavelength partitioning element, and detection element. The gases of interest are measured simultaneously and, further, can be measured independently or non-independently. Furthermore, optical or electronic element are provided to balance optical intensities between the two optical paths.

Sachse, Glenn W.↗

Numerical schemes for a multi-species BGK model with velocity-dependent collision frequency

Here, we consider a kinetic description of multi-species gas mixture modeled with Bhatnagar-Gross-Krook (BGK) collision operators, in which the collision frequency varies not only in time and space but also with the microscopic velocity. In this model, the Maxwellians typically used in standard BGK operators are replaced by a generalization of such target functions, which are defined by a variational procedure. In this paper we present a numerical method for simulating this model, which uses an Implicit-Explicit (IMEX) scheme to minimize a certain potential function, mimicking the Lagrange functional that appears in the theoretical derivation. We show that theoretical properties such as conservation of mass, total momentum and total energy as well as positivity of the distribution functions are preserved by the numerical method, and illustrate its usefulness and effectiveness with numerical examples.

97 MATHEMATICS AND COMPUTING↗

A Multi-Function AAA Algorithm Applied to Frequency Dependent Line Modeling

Modeling of power distribution system components that are valid for a wide range of frequencies are crucial for highly accurate modeling of electromagnetic transient (EMT) events. This has recently become of interest due to the improvements needed for the resilient operation of distribution systems. Vector fitting (VF) is a very popular and commonly used algorithm for wide band representations of power system components in EMT simulations. In this research, we present a new multi-input rational approximation algorithm (MIAAA) and illustrate its advantages with respect to VF using examples of approximations of admittance matrices discussed in the literature. We show that MIAAA not only outperforms VF in terms of achieving better accuracy using lesser number of poles, but also has no numerical issues achieving convergence. In contrast to VF, MIAAA is not sensitive to the location of input sample points and it does not require good estimates for the location of the desired approximation poles. The novelty of this research work is the use of recent mathematical results to solve existing challenges in distribution system modeling and to develop rational approximations for power system models that intend to be optimal in terms of accuracy and performance.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Ultrafast Narrow Band Modulation of VCSELs

Multimode beating was greatly enhanced by taking output from part (e.g., half) of the output facet. Simpler sources of microwaves and millimeter waves of various frequencies were generated by varying the VCSEL diameter in a single multimode VCSEL our coupling of a few VCSELs. Breathing frequency in multi-mode operations affects modulation response and bandwidth. Optimizing RO frequency and mode beating frequency could potentially expand bandwidths suitable for wide band digital communications.

Ning, Cun-Zheng↗

EMT and Phasor-Domain Co-simulation of a Low Frequency AC Transmission System for Offshore Wind Integration

This work investigates system level interactions of multi-terminal low frequency high-voltage alternating current (LF-HVac) system using back-to back converters and grid-level 60 Hz system. A co-simulation framework by integrating high- fidelity dynamic model of multi-terminal LF-HVac system in electromagnetic transient (EMT) simulation platform and phasor model of IEEE 39 bus system in transient-stability (phasor) program. The co-simulation framework for multi-terminal LF- HVac system with offshore wind integrated in a bulk power system is developed successfully and its steady state and dynamic operation is demonstrated and compared with EMT simulation. The co-simulation results show accurate representation of the dynamic responses with reduced computation burden and time compared to EMT platform.

low-frequency transmission, co-simulation, electro↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗