Search NASA⌕ Search

SEARCH · Search NASA

Results for “reactivity control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Deep Learning Modeling Framework to Capture Mixing Patterns in Reactive-Transport Systems

Prediction and control of chemical mixing are vital for many scientific areas such as subsurface reactive transport, climate modeling, combustion, epidemiology, and pharmacology. Due to the complex nature of mixing in heterogeneous and anisotropic media, the mathematical models related to this phenomenon are not analytically tractable. Numerical simulations often provide a viable route to predict chemical mixing accurately. However, contemporary modeling approaches for mixing cannot utilize available spatial-temporal data to improve the accuracy of the future prediction and can be compute-intensive, especially when the spatial domain is large and for long-term temporal predictions. To address this knowledge gap, in this work we will present in this paper a deep learning (DL) modeling framework applied to predict the progress of chemical mixing under fast bimolecular reactions. This framework uses convolutional neural networks (CNN) for capturing spatial patterns and long short-term memory (LSTM) networks for forecasting temporal variations in mixing. By careful design of the framework—placement of non-negative constraint on the weights of the CNN and the selection of activation function, the framework ensures non-negativity of the chemical species at all spatial points and for all times. Our DL-based framework is fast, accurate, and requires minimal data for training. The time needed to obtain a forecast using the model is a fraction (≈ O(-6)) of the time needed to obtain the result using a high-fidelity simulation. To achieve an error of 10% (measured using the infinity norm) for capturing local-scale mixing features such as interfacial mixing, only 24% to 32% of the sequence data for model training is required. To achieve the same level of accuracy for capturing global-scale mixing features, the sequence data required for model training is 64% to 70% of the total spatial-temporal data. Hence, the proposed approach—a fast and accurate way to forecast long-time spatial-temporal mixing patterns in heterogeneous and anisotropic media—will be a valuable tool for modeling reactive-transport in a wide range of applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Power Converter Topologies for Electrolyzer Applications to Enable Electric Grid Services

Hydrogen electrolyzers, with their operational flexibility, can be configured as smart dynamic loads which can provide grid services and facilitate the integration of more renewable energy sources into the electrical grid. However, to enable this ability, the electrolyzer system should be able to control both active and reactive power in coordination with the low-level controller of the electrolyzer via the power electronics system interface between the utility grid and electrolyzer. This paper discusses power converter topologies and the control scheme of this power electronics interface for electrolyzer applications to enable electricity grid services. For the sake of unity, in this paper, we consider the power converter system interfacing the utility grid at the line-to-line root mean square (RMS) value of 480 VAC-60 Hz and supplying to the 3500 A-750 kW PEM electrolyzer stack.

electrolyzer↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

grid-following inverter↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This presentation discusses the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

droop control↗

Multiple-Nozzle Spray Head Applies Foam Insulation

Spray head equipped with four-nozzle turret mixes two reactive components of polyurethane and polyisocyanurate foam insulating material and sprays reacting mixture onto surface to be insulated. If nozzle in use becomes clogged, fresh one automatically rotated into position, with minimal interruption of spraying process. Incorporates features recirculating and controlling pressures of reactive components to maintain quality of foam by ensuring proper blend at outset. Also used to spray protective coats on or in ships, aircraft, and pipelines. Sprays such reactive adhesives as epoxy/polyurethane mixtures. Components of spray contain solid-particle fillers for strength, fire retardance, toughness, resistance to abrasion, or radar absorption.

Walls, Joe T.↗

Steering the Methane Dry Reforming Reactivity of Ni/La 2 O 3 Catalysts by Controlled In Situ Decomposition of Doped La 2 NiO 4 Precursor Structures

The influence of A- and/or B-site doping of Ruddlesden-Popper perovskite materials on the crystal structure, stability, and dry reforming of methane (DRM) reactivity of specific A 2 BO 4 phases (A = La, Ba; B = Cu, Ni) has been evaluated by a combination of catalytic experiments, in situ X-ray diffraction, X-ray absorption spectroscopy (XAS), X-ray photoelectron spectroscopy (XPS), and aberration-corrected electron microscopy. At room temperature, B-site doping of La 2 NiO 4 with Cu stabilizes the orthorhombic structure ( Fmmm ) of the perovskite, while A-site doping with Ba yields a tetragonal space group ( I 4/ mmm ). We observed the orthorhombic-to-tetragonal transformation above 170 °C for La 2 Ni 0.9 Cu 0.1 O 4 and La 2 Ni 0.8 Cu 0.2 O 4 , slightly higher than for undoped La 2 NiO 4 . Loss of oxygen in interstitial sites of the tetragonal structure causes further structure transformations for all samples before decomposition in the temperature range of 400 °C-600 °C. Controlled in situ decomposition of the parent or A/B-site doped perovskite structures in a DRM mixture (CH 4 :CO 2 = 1:1) in all cases yields an active phase consisting of exsolved nanocrystalline metallic Ni particles in contact with hexagonal La 2 O 3 and a mixture of (oxy)carbonate phases (hexagonal and monoclinic La 2 O 2 CO 3 , BaCO 3 ). Differences in the catalytic activity evolve because of (i) the in situ formation of Ni-Cu alloy phases (in a composition of >7:1 = Ni:Cu) for La 2 Ni 0.9 Cu 0.1 O 4 , La 2 Ni 0.8 Cu 0.2 O 4 , and La 1.8 Ba 0.2 Ni 0.9 Cu 0.1 O 4 , (ii) the resulting Ni particle size and amount of exsolved Ni, and (iii) the inherently different reactivity of the present (oxy)carbonate species. Based on the onset temperature of catalytic DRM activity, the latter decreases in the order of La 2 Ni 0.9 Cu 0.1 O 4 ~ La 2 Ni 0.8 Cu 0.2 O 4 ≥ La 1.8 Ba 0.2 Ni 0.9 Cu 0.1 O 4 > La 2 NiO 4 > La 1.8 Ba 0.2 NiO 4 . Simple A-site doped La 1.8 Ba 0.2 NiO 4 is essentially DRM inactive. The Ni particle size can be efficiently influenced by introducing Ba into the A site of the respective Ruddlesden-Popper structures, allowing us to control the Ni particle size between 10 nm and 30 nm both for simple B-site and A-site doped structures. Hence, it is possible to steer both the extent of the metal-oxide-(oxy)carbonate interface and its chemical composition and reactivity. Counteracting the limitation of the larger Ni particle size, the activity can, however, be improved by additional Cu-doping on the B-site, enhancing the carbon reactivity. Exemplified for the La 2 NiO 4 based systems, we show how the delicate antagonistic balance of doping with Cu (rendering the La 2 NiO 4 structure less stable and suppressing coking by efficiently removing surface carbon) and Ba (rendering the La 2 NiO 4 structure more stable and forming unreactive surface or interfacial carbonates) can be used to tailor prospective DRM-active catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV

In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.

14 SOLAR ENERGY↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗

Self-Aware Local Autonomous and Semi-Cooperative Control for Cross-Layered Resilience (SLAC3R)

The objective of this work is to develop and demonstrate novel, adaptive, lightweight algorithms that enable the decision-making agents in a large cyber-physical network to act both autonomously and in collaborative harmony to enforce assured resilience across spatiotemporal layers, even under unforeseen adversarial scenarios (e.g., high- impact-low-probability events). Towards this end, the proposed solution will serve as minimally invasive add-on layers that bridge the existing (faster, reactive) local myopic controls and (slower, predictive) centralized optimization. Importantly, the proposed algorithms will enable the multi-agent network to autonomously and collaboratively enforce resilient operation under no or limited communication environment typical of severe cyber- physical adversarial events. The expected outcome of this effort is a suite of prototype, open-source, software algorithms for safety-aware local autonomous and semi-cooperative control (SLAC3R), demonstrated on networked microgrids (via RD2C/Thrust-1 OPAL-RT testbed).

97 MATHEMATICS AND COMPUTING↗

High performance N2O4/amine elements: Blowapart

The mechanisms controlling hypergolic propellant reactive stream separation (RRS) were studied and used to develop design criteria for injectors free from both steady state RSS and cyclic propellant stream separation. This was accomplished through the analysis of single element injectors using N204/MMH propellants; the injectors were representative of the space shuttle orbit maneuvering engine and space tug applications. A gas phase/surface reaction mechanism which controls RSS was identified. Injector design criteria were developed, which defined a critical chamber pressure for those operating conditions above which RSS occurs. It was found that the amount of interfacial surface area at impingement is controlled by injector hydraulics.

Lawver, B. R.↗

Indium–Poly(carboxylic acid) Ligand Interactions Modify InP Quantum Dot Nucleation and Growth

Size control through precursor reactivity in InP quantum dot (QD) synthesis has been difficult due to the presence of kinetically persistent InP clusters when using conventional indium carboxylate and tris(trimethylsilyl)phosphine chemistry. However, the advent of indium halide/aminophosphine-based synthesis creates new opportunities to harness precursor design to impact nucleation and growth. Driven to further explore indium coordination as a synthetic handle in InP QD synthesis, we examined the effect of a strongly chelating anion on the nucleation and growth of InP QDs. Increasing the equivalents of metal-chelating aminopoly(carboxylic acid) EDTA ([CH 2 N(CH 2 CO 2 H) 2 ] 2 ) (0–0.75 equiv per indium) is found to decrease the final diameter of InP QDs from 4.5 to 2.3 nm by lowering the initial InP growth rate. This size trend is rationalized by invoking a continuous nucleation model. Control experiments carried out with substoichiometric equivalents of indium do not exhibit a drastic size decrease, pointing to complex effects of EDTA on the indium precursor reactivity. By 1 H NMR spectroscopy, EDTA is identified to form an octahedral complex with indium that is less reactive. Furthermore, this competitive decrease in reactivity and in the effective concentration of indium precursor is proposed to suppress the initial InP growth rates and consequently decrease the final size of the nanocrystals.

36 MATERIALS SCIENCE↗

Arterial baroreflex control of sympathetic nerve activity during acute hypotension: effect of fitness

We examined arterial baroreflex control of muscle sympathetic nerve activity (MSNA) during abrupt decreases in mean arterial pressure (MAP) and evaluated whether endurance training alters baroreflex function. Acute hypotension was induced nonpharmacologically in 14 healthy subjects, of which 7 were of high fitness (HF) and 7 were of average fitness (AF), by releasing a unilateral arterial thigh cuff after 9 min of resting ischemia under two conditions: control, which used aortic and carotid baroreflex (ABR and CBR, respectively) deactivation; and suction, which used ABR deactivation alone. The application of neck suction to counteract changes in carotid sinus transmural pressure during cuff release significantly attenuated the MSNA response (which increased 134 +/- 32 U/14 s) compared with control (which increased 195 +/- 43 U/14 s) and caused a greater decrease in MAP (19 +/- 2 vs. 15 +/- 2 mmHg; P < 0.05). Furthermore, during both trials, the HF subjects exhibited a greater decrease in MAP compared with AF subjects despite an augmented baroreflex control of MSNA. These data indicate that the CBR contributes importantly to the MSNA response during acute systemic hypotension. Additionally, we suggest that an impaired control of vascular reactivity hinders blood pressure regulation in HF subjects.

Non-NASA Center↗

Predictive and Cooperative Voltage Control with Probabilistic Load and Solar Generation Forecasting

This paper proposes predictive cooperative voltage control method in a power system with high penetration of photovoltaic (PV) units. Cooperative distributed control of the reactive power output of PV inverters is coordinated with operation of voltage regulators (VRs) to maintain system voltages within an appropriate bandwidth. Probabilistic forecasting of the solar power generation and the loads is applied to estimate voltage changes which, in turn, are used to set the VR tap positions for preventing large voltage fluctuations with the lowest risk considering the voltage distribution estimation. The fine tuning of voltage adjustment is achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on the modified IEEE 123-node test feeder with high PV penetration using real insolation data and with constant loads replaced by several different load profiles. Simulation results demonstrate the effectiveness of the coordinated approach for voltage control with cooperative PV and predictive VR controls taking into account probabilistic load and solar power forecasts.

Cooperative Control↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

TRIPOLI-4 neutronics calculations for IAEA-CRP benchmark of CEFR start-up tests using new libraries JEFF-3.3 and ENDF/B-VIII

Sodium-cooled Fast Reactors (SFR) are one of the promising Generation IV fast reactors. The China Experimental Fast Reactor (CEFR) is a 65 MWth pool-type SFR with a high neutron leakage core using high enriched uranium oxide fuel. The CEFR start-up tests in 2010 consist of series of neutronics experiments. Essential experimental data are available from the 2018 IAEA-CEFR-CRP benchmark document and useful for the validation of neutron transport codes and nuclear data libraries. The TRIPOLI-4 Monte Carlo transport code is a general-purpose neutronics code using continuous-energy nuclear data libraries. It has a rich validation database covering different computational and experimental benchmark data sets to assure the accuracy and credibility of numerical studies. Previous TRIPOLI-4 SFR core physics calculations used mainly MOX fuels. SFR control rod worth studies with TRIPOLI-4 were mainly on big-size cores. To test the modeling capability of TRIPOLI-4 on fuel loading patterns and on variable control rods positions for SFRs and to check recent nuclear data libraries, it is interesting to investigate the CEFR start-up tests in this work, including core states from subcritical to supercritical, control rods and rod group worth, point kinetics parameters, and radial foil activation measurements. TRIPOLI-4 calculation results using new data libraries JEFF-3.3, ENDF/B-VIII, and those of ENDF/B-VII.1 for different CEFR core states are reported here. By means of different options of TRIPOLI-4, control-rod SAs reactivity worth, point kinetics parameters, and radial {sup 237}Np(n,f) fission rate distribution were successfully evaluated. Both ENDF/B-VIII and JEFF-3.3 nuclear data libraries provided reliable results with a difference of 170 +/- 11 pcm in k{sub eff}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗