Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Carbon trimer as a 2 eV single-photon emitter candidate in hexagonal boron nitride: A first-principles study

The generation of single-photon emitters in hexagonal boron nitride around 2 eV emission is experimentally well recognized; however, the atomic nature of these emitters is unknown. In this Letter, we use first-principles calculations to demonstrate that carbon trimer substitutional defect (C 2 C N ) is a possible source of 2 eV single-photon emitter in hBN. Here, we showcase the calculations of a complete set of static and dynamical properties related to quantum defects, including exciton-defect couplings and electron-phonon interactions, from both density functional theory and many-body perturbation theory. In particular, we show that it is critical to consider both radiative and nonradiative processes when comparing with experimental lifetime for known 2 eV emitters. We find that C 2 C N has several key physical properties matching the ones of experimentally observed single-photon emitters. These include the zero-phonon line (2.13 eV), Huang-Rhys factor (1.35), photoluminescence lifetime (2.19 ns), phonon-sideband energy (180 meV), and photoluminescence spectrum. The identification of defect candidates for 2 eV emission paves the way for controllable single-photon emission generation.

36 MATERIALS SCIENCE↗

Advanced data readout technique for Multianode Position Sensitive Photomultiplier Tube applicable in radiation imaging detectors

Most of the best performing PSPMT tubes from Hamamatsu and Burle are designed with a pad-matrix anode layout. However, for obtaining a high resolution, a small-sized anode photomultiplier tubes are preferable; these tubes may have 64, 256 or 1024 anodes per tube. If the tubes are used in array to get a larger area detector, the number of analog channels may range from hundreds to thousands. Multichannel analog readout requires special electronics ICs, ASICs etc., which are attached to multichannel DAQ system. As a result, the data file and data processing time will be increased. Therefore, this readout could not be performed in a small project. Usually, most of radiation imaging applications allow the use of analog data processing in front-end electronics, significantly reducing the number of the detector's output lines to data acquisition without reducing the image quality. The idea of pad-matrix decoupling circuit with gain correction was invented and intensively tested in JLab. Several versions of PSPMT readout electronics were produced and studied. All developments were done and optimized specifically for radiation imaging projects. They covered high resolution SPECT, high speed PET, fast neutron imaging, and single tube and multi tube array systems. This paper presents and discusses the summary of the observed results in readout electronics evaluation with different PSPMTs and radiation imaging systems, as well as the advantages and limitations of the developed approach to radiation imaging detectors readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of a method for activity estimation in Sm-153 EDTMP imaging

Absolute activity evaluation is fundamental for internal radionuclide dosimetry when patient-specific therapy optimization is wanted. Often, quantification is attempted with 3D SPECT image based (IB) methods, but the true concentration values can be underestimated due to the partial volume effect (PVE). This is especially true when small diffuse lesions are present. In this paper, we describe a 3D region of interest (ROI) based quantification method (LS-ROI), which estimates the ROI concentration values directly from the projection data acquired in the tomographic scan once ROIs have been segmented on a CT and/or a SPECT image. The method, which has inherent PVE correction capabilities, was applied both on simulated and on real phantom data. Simulations reflected the case of a patient with bone metastases treated with {sup 153}Sm-EDTMP: Both the activity in the metastases and the total retention in the skeleton were evaluated. Thirty noisy data sets were produced in order to evaluate the accuracy and precision of the method. The effect of region segmentation errors on estimated concentrations was thoroughly investigated. Real data were acquired on a NEMA phantom, where a cylindrical central region (283 cm{sup 3}) simulated the bone and two spheres (10.3 and 25.5 cm{sup 3}) simulated the metastases. The results obtained with the LS-ROI method were compared with those of a conventional 3D IB method and those of a quantitative conjugate view approach derived from LS-ROI and applied to the anterior and posterior views acquired in the tomographic scan (LS-ROI anterior-posterior: LS-ROI-AP). Simulations showed that when the geometry of regions is known, the LS-ROI method recovered the simulated concentration values within 20%, while the IB method underestimated the concentration in high activity small lesions by as much as 49%. Segmentation errors, up to 44% of the true region volume, produced a higher variation in LS-ROI estimates than in IB ones; however, the overall bias of the LS-ROI estimates ({<=}25%) remained lower than that of IB estimates. In the case of the evaluation of the total retention in the skeleton, the LS-ROI method recovered the simulated value within 2%, while IB underestimated it up to 13%. In all the cases, the LS-ROI-AP method showed an accuracy comparable with that of the LS-ROI one, and a worse precision just because of the lower number of counts used in the analysis. However, a worsening of LS-ROI-AP performances was demonstrated in the case of strong overlap of regions: In this case, a bias of up to 40% was observed. The results obtained on real phantom data confirmed the simulation results: The IB method underestimated activity up to 47% in the smallest sphere, while the bias was reduced to 13% with LS-ROI and LS-ROI-AP estimates. The good quantification capabilities of the LS-ROI method can be useful for absolute activity quantification in the case of small active diffused lesions and constitute the basis for the development of an accurate patient-specific planning strategy in internal radionuclide treatments, provided there is a reliable segmentation of lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Monte Carlo-based holmium-166 SPECT reconstruction

Purpose: Quantitative imaging of the radionuclide distribution is of increasing interest for microsphere radioembolization (RE) of liver malignancies, to aid treatment planning and dosimetry. For this purpose, holmium-166 ({sup 166}Ho) microspheres have been developed, which can be visualized with a gamma camera. The objective of this work is to develop and evaluate a new reconstruction method for quantitative {sup 166}Ho SPECT, including Monte Carlo-based modeling of photon contributions from the full energy spectrum.Methods: A fast Monte Carlo (MC) simulator was developed for simulation of {sup 166}Ho projection images and incorporated in a statistical reconstruction algorithm (SPECT-fMC). Photon scatter and attenuation for all photons sampled from the full {sup 166}Ho energy spectrum were modeled during reconstruction by Monte Carlo simulations. The energy- and distance-dependent collimator-detector response was modeled using precalculated convolution kernels. Phantom experiments were performed to quantitatively evaluate image contrast, image noise, count errors, and activity recovery coefficients (ARCs) of SPECT-fMC in comparison with those of an energy window-based method for correction of down-scattered high-energy photons (SPECT-DSW) and a previously presented hybrid method that combines MC simulation of photopeak scatter with energy window-based estimation of down-scattered high-energy contributions (SPECT-ppMC+DSW). Additionally, the impact of SPECT-fMC on whole-body recovered activities (A{sup est}) and estimated radiation absorbed doses was evaluated using clinical SPECT data of six {sup 166}Ho RE patients.Results: At the same noise level, SPECT-fMC images showed substantially higher contrast than SPECT-DSW and SPECT-ppMC+DSW in spheres ≥17 mm in diameter. The count error was reduced from 29% (SPECT-DSW) and 25% (SPECT-ppMC+DSW) to 12% (SPECT-fMC). ARCs in five spherical volumes of 1.96–106.21 ml were improved from 32%–63% (SPECT-DSW) and 50%–80% (SPECT-ppMC+DSW) to 76%–103% (SPECT-fMC). Furthermore, SPECT-fMC recovered whole-body activities were most accurate (A{sup est}= 1.06 × A − 5.90 MBq, R{sup 2}= 0.97) and SPECT-fMC tumor absorbed doses were significantly higher than with SPECT-DSW (p = 0.031) and SPECT-ppMC+DSW (p = 0.031).Conclusions: The quantitative accuracy of {sup 166}Ho SPECT is improved by Monte Carlo-based modeling of the image degrading factors. Consequently, the proposed reconstruction method enables accurate estimation of the radiation absorbed dose in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-94: Development of a Plug-in Based Image Analysis Tool for Integration Into Treatment Planning

Purpose: To extend the functionality of a commercial treatment planning system (TPS) to support (i) direct use of quantitative image-based metrics within treatment plan optimization and (ii) evaluation of dose-functional volume relationships to assist in functional image adaptive radiotherapy. Methods: A script was written that interfaces with a commercial TPS via an Application Programming Interface (API). The script executes a program that performs dose-functional volume analyses. Written in C#, the script reads the dose grid and correlates it with image data on a voxel-by-voxel basis through API extensions that can access registration transforms. A user interface was designed through WinForms to input parameters and display results. To test the performance of this program, image- and dose-based metrics computed from perfusion SPECT images aligned to the treatment planning CT were generated, validated, and compared. Results: The integration of image analysis information was successfully implemented as a plug-in to a commercial TPS. Perfusion SPECT images were used to validate the calculation and display of image-based metrics as well as dose-intensity metrics and histograms for defined structures on the treatment planning CT. Various biological dose correction models, custom image-based metrics, dose-intensity computations, and dose-intensity histograms were applied to analyze the image-dose profile. Conclusion: It is possible to add image analysis features to commercial TPSs through custom scripting applications. A tool was developed to enable the evaluation of image-intensity-based metrics in the context of functional targeting and avoidance. In addition to providing dose-intensity metrics and histograms that can be easily extracted from a plan database and correlated with outcomes, the system can also be extended to a plug-in optimization system, which can directly use the computed metrics for optimization of post-treatment tumor or normal tissue response models. Supported by NIH - P01 - CA059827.

60 APPLIED LIFE SCIENCES↗

X-ray Parametric Down Conversion at an XFEL

Understanding and harnessing X-ray quantum effects could open new frontiers in imaging and quantum optics. In this study, we measured the process of X-ray Parametric Down Conversion, where a single high-energy X-ray photon splits into two lower-energy photons. Using the SACLA X-ray Free Electron Laser in Japan at 9.83 keV, we found clear evidence that pairs of photons were produced along the energy-angle relationship that conserved both energy and momentum, as predicted for down-conversion, and consistent with quantum entanglement of X-ray photons. By matching specific photon pairs for energy and momentum conservation, we observe a signal rate of 1,250 pairs per hour, confirming that correlated photon pairs can be generated and observed in the absence of explicit time correlations. Our results show that with further refinement, the number of entangled photons produced per laser pulse could increase by an order of magnitude. This paves the way for demonstrating quantum-enhanced X-ray imaging, and confirmation of X-ray photon entanglement.

47 OTHER INSTRUMENTATION↗

High-Quality Factor Microwave Resonators using Rhenium

Coplanar waveguide resonators are a perfect tool to evaluate the losses induced by defects and interfaces in superconducting devices. Even if niobium is the most used superconductor for resonators and qubits, its native oxide at the metal-air (MA) interface limits the device results. Tantalum has recently significantly improved qubit performances due to a thinner and less disordered oxide layer compared to Nb. To further improve the MA interface, we used rhenium, a superconducting material with 1.7 K critical temperature resistant to oxidation: it forms an oxide layer thinner than 1 nm. In this study, we will present a thorough investigation of rhenium CPW resonator measurements with internal quality factors at the single photon level exceeding 2 million. The devices have been fabricated on a sapphire substrate while the processing parameters have been varying and optimized. The measurements have been performed as a function of power and temperature to disentangle different sources of losses, such as two-level systems (TLS) and quasi-particles. A peculiar TLS temperature dependence has been measured and analyzed. In this work, we also vary the participation ratio of the devices to extract the losses introduced by the involved interfaces with higher fidelity and precision. We carried on a deep material characterization effort to link the results to the differences in the fabrication steps, and we will present material characterization measurements performed via AFM, ToF-SIMS, XPS, and TEM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A High Dynamic-Range Photon-Counting Receiver for Deep Space Optical Communication

The Deep Space Optical Communication (DSOC) project will demonstrate free-space optical communication at almost 3 AU, or 3 orders of magnitude further than any previous attempt. DSOC will utilize the 5m Palomar Hale Telescope to receive the downlink signal, which will couple the downlink light onto an optical table and into a superconducting nanowire single photon detector (SNSPD). The output of the SNSPD is digitized by the Ground Laser Receiver Signal Processing Assembly (GSPA) using a high throughput streaming time to digital converter (TDC). The GSPA is a scalable FPGA-based receiver which demodulates and decodes the DSOC downlink signal through novel signal processing algorithms implemented on Xilinx UltraScale+ FPGAs, as well as Python-based software monitor and control routines. Exploiting the unique TDC-based architecture, the GSPA supports over four orders of magnitude of downlink data rates across multiple orders of magnitude of signal and background powers. In this paper we present an overview of the hardware, firmware and software architectures to implement this system, as well as performance analysis for links ranging from near-Earth to 2.8 AU.

Srinivasan, Meera↗

Solvent Effect on the Photoinduced Structural Change of a Phosphorescent Molecular Butterfly

Abstract Photoinduced structural changes (PSC) is one of the fundamental excited‐state dynamic processes, and yet often very challenging to distinguish from competing electronic excited‐state relaxation channels having similar or even comparable timescales. Here, we report a detailed study on the PSC of a pyrazolate bridged platinum(II) binuclear complex, BFPtPZ (C^NPt(μ‐pz′) 2 PtC^N, C^N=2‐(2,4‐difluorophenyl)pyridine, pz′=pyrazolate), a molecular butterfly, using time‐correlated single photon counting measurements at different wavelengths and sample temperatures. Analysis of the results obtained using dichloromethane (DCM) and ethylene carbonate (EC) as solvents enabled us to reveal an unexpected, strong solvent effect on the PSC processes. We show that a rapid PSC process with a characteristic timescale of 323 ps is observed in DCM, which leads to an excitation equilibrium between the ligand center/metal‐to‐ligand charge transfer ( 3 LC/MLCT) and metal‐metal‐to‐ligand charge transfer ( 3 MMLCT) triplet states. The subsequent relaxation from these electronic states to the ground state takes place in several nanoseconds. In contrast, the corresponding PSC process in EC appears slow at all temperatures studied in our experiments and showed no sign of such excitation equilibrium. The observed solvent effect is found to arise from distinct solvent properties including their viscosities and polarities as well as the peculiar electronic excited‐states of the butterfly‐like molecules with charge transfer character.

Ma, Ying‐Zhong↗

Impact of extraneous mispositioned events on motion-corrected brain SPECT images of freely moving animals

Purpose: Single photon emission computed tomography (SPECT) brain imaging of freely moving small animals would allow a wide range of important neurological processes and behaviors to be studied, which are normally inhibited by anesthetic drugs or precluded due to the animal being restrained. While rigid body motion of the head can be tracked and accounted for in the reconstruction, activity in the torso may confound brain measurements, especially since motion of the torso is more complex (i.e., nonrigid) and not well correlated with that of the head. The authors investigated the impact of mispositioned events and attenuation due to the torso on the accuracy of motion corrected brain images of freely moving mice. Methods: Monte Carlo simulations of a realistic voxelized mouse phantom and a dual compartment phantom were performed. Each phantom comprised a target and an extraneous compartment which were able to move independently of each other. Motion correction was performed based on the known motion of the target compartment only. Two SPECT camera geometries were investigated: a rotating single head detector and a stationary full ring detector. The effects of motion, detector geometry, and energy of the emitted photons (hence, attenuation) on bias and noise in reconstructed brain regions were evaluated. Results: The authors observed two main sources of bias: (a) motion-related inconsistencies in the projection data and (b) the mismatch between attenuation and emission. Both effects are caused by the assumption that the orientation of the torso is difficult to track and model, and therefore cannot be conveniently corrected for. The motion induced bias in some regions was up to 12% when no attenuation effects were considered, while it reached 40% when also combined with attenuation related inconsistencies. The detector geometry (i.e., rotating vs full ring) has a big impact on the accuracy of the reconstructed images, with the full ring detector being more advantageous. Conclusions: Motion-induced inconsistencies in the projection data and attenuation/emission mismatch are the two main causes of bias in reconstructed brain images when there is complex motion. It appears that these two factors have a synergistic effect on the qualitative and quantitative accuracy of the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Role of dipole-forbidden autoionizing resonances in nonresonant one-color two-photon single ionization of N 2

We present an experimental and theoretical energy- and angle-resolved study on the photoionization dynamics of non-resonant one-color two-photon single valence ionization of neutral N$_2$ molecules. Using 9.3 eV photons produced via high harmonic generation and a 3-D momentum imaging spectrometer, we detect the photoelectrons and ions produced from one-color two-photon ionization in coincidence. Photoionization of N$_2$ populates the X $^2\Sigma^+_g$, A $^2\Pi_u$, and B $^2\Sigma^+_u$ ionic states of N$_2^+$, where the photoelectron angular distributions associated with the X $^2\Sigma^+_g$ and A $^2\Pi_u$ states both vary with changes in photoelectron kinetic energy of only a few hundred meV. We attribute the rapid evolution in the photoelectron angular distributions to the excitation and decay of dipole-forbidden autoionizing resonances that belong to series of different symmetries, all of which are members of the Hopfield series, and compete with the direct two-photon single ionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Metal oxide core shell nanostructures as building blocks for efficient light emission (SISGR)

The objective of this research is to synthesize core-shell nano-structured metal oxide materials and investigate their structural, electronic and optical properties to understand the microscopic pathways governing the energy conversion process, thereby controlling and improving their efficiency. Specifically, the goal is to use a single metal oxide core-shell nanostructure and a single excitation source to generate photons with long emission lifetime over the entire visible spectrum and when controlled at the right ratio, generating white light. In order to achieve this goal, we need to control the energy transfer between light emitting elements, which dictates the control of their interatomic spacing and spatial distribution. We developed an economical wet chemical process to form the nanostructured core and to control the thickness and composition of the shell layers. With the help from using DOE funded synchrotron radiation facility, we delineated the growth mechanism of the nano-structured core and the shell layers, thereby enhancing our understanding of structure-property relation in these materials. Using the upconversion luminescence and the lifetime measurements as effective feedback to materials sysnthes is and integration, we demonstrated improved luminescence lifetimes of the core-shell nano-structures and quantified the optimal core-multi-shell structure with optimum shell thickness and composition. We developed a rare-earths co-doped LaPO 4 core-multishell structure in order to produce a single white light source. It was decided that the mutli-shell method would produce the largest increase in luminescence efficiency while limiting any energy transfer that may occur between the dopant ions. All samples resulted in emission spectra within the accepted range of white light generation based on the converted CIE color coordinates. The white light obtained varied between warm and cool white depending on the layering architecture, allowing for the utilization into a wide range of applications. With DOE’s overall mandate to reduce the US’s dependence on rare-earth elements, this work demonstrated how to make every RE atom count toward white light generation by controlling their spatial distribution thereby significantly reducing the amount needed. This is one approach toward reducing the dependence on RE elements and the strategies we developed can be used in discovering RE-free systems. The project is of benefit to the general public as it improves the optical efficiency of these materials, while reducing US’s dependence on RE elements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multipolariton control in attosecond transient absorption of autoionizing states

Tunable attosecond transient absorption spectroscopy is an ideal tool for studying and manipulating autoionization dynamics in the continuum. We investigate near-resonant two-photon couplings between the bright 3s –1 4p and dark 3s –1 4f autoionizing states of argon that lead to Autler-Townes-like interactions, forming entangled light-matter states or polaritons. We observe that one-photon couplings with intermediate dark states play an important role in this interaction, leading to the formation of multiple polaritonic branches whose energies exhibit avoided crossings as a function of the dressing-laser frequency. Our experimental measurements and theoretical essential-state simulations show good agreement and reveal how the delay, frequency, and intensity of the dressing pulse govern the properties of autoionizing polariton multiplets. Furthermore, these results demonstrate new pathways for quantum control of autoionizing states with optical fields.

74 ATOMIC AND MOLECULAR PHYSICS↗

Focused-ion-beam overlay-patterning of three-dimensional diamond structures for advanced single-photon properties

Sources of single photons are of fundamental importance in many applications as to provide quantum states for quantum communication and quantum information processing. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, even at room temperature. However, the efficiency of photon collection of the color centers in bulk diamond is greatly reduced by refraction at the diamond/air interface. To address this issue, diamond structuring has been investigated by various methods. Among them, focused-ion-beam (FIB) direct patterning has been recognized as the most favorable technique. But it has been noted that diamond tends to present significant challenges in FIB milling, e.g., the susceptibility of forming charging related artifacts and topographical features. In this work, periodically-positioned-rings and overlay patterning with stagger-superimposed-rings were proposed to alleviate some problems encountered in FIB milling of diamond, for improved surface morphology and shape control. Cross-scale network and uniform nanostructure arrays have been achieved in single crystalline diamond substrates. High quality diamond solid immersion lens and nanopillars were sculptured with a nitrogen-vacancy center buried at the desired position. Compared with the film counterpart, an enhancement of about ten folds in single photon collection efficiency was achieved with greatly improved signal to noise ratio. All these results indicate that FIB milling through over-lay patterning could be an effective approach to fabricate diamond structures, potentially for quantum information studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Digital pulse processing for NaI(Tl) detectors

We apply two different post-processing techniques to digital pulses induced by photons in a NaI(Tl) detector and compare the obtained energy resolution to the standard analog approach. Our digital acquisition approach is performed using a single-stage acquisition with a fast digitizer. Both the post-processing techniques we propose rely on signal integration. In the first, the pulse integral is calculated by directly numerically integrating the pulse digital samples, while in the second the pulse integral is estimated by a model-based fitting of the pulse. Our study used a 7.62 cm×7.62 cm cylindrical NaI(Tl) detector that gave a 7.60% energy resolution (at 662 keV), using the standard analog acquisition approach, based on a pulse shaping amplifier. The new direct numerical integration yielded a 6.52% energy resolution. The fitting approach yielded a 6.55% energy resolution, and, although computationally heavier than numerical integration, is preferable when only the early samples of the pulse are available. We also evaluated the timing performance of a fast–slow detection system, encompassing an EJ-309 and a NaI(Tl) scintillator. Here, we use two techniques to determine the pulse start time: constant fraction discrimination (CFD) and adaptive noise threshold timing (ANT), for both the analog and digital acquisition approach. With the analog acquisition approach, we found a system time resolution of 5.8 ns and 7.3 ns, using the constant fraction discrimination and adaptive noise threshold timing, respectively. With the digital acquisition approach, a time resolution of 1.2 ns was achieved using the ANT method and 3.3 ns using CFD at 50% of the maximum, to select the pulse start time. Finally, the proposed direct digital readout and post-processing techniques can improve the application of NaI(Tl) detectors, traditionally considered ‘slow’, for fast counting and correlation measurements, while maintaining a good measurement of the energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoionization and photofragmentation of singly charged positive and negative Sc 3 N @ C 80 endohedral fullerene ions

Photoprocesses of the endohedral fullerene ions $\mathrm{Sc_3N@C_{80}^{+}}$ and $\mathrm{Sc_3N@C_{80}-}$ in the gas phase have been investigated in the photon energy ranges 30-50 eV and 280-420 eV. Single and double ionization as well as single ionization accompanied by the release of a C 2 dimer were observed as a function of the photon energy for the positive parent ion and double detachment was measured for the negative parent ion. The emphasis of the experiments was on the specific effects of the encapsulated trimetallic nitride cluster Sc 3 N on the observed reactions. Clear evidence of photoexcitation near the Sc L edge is obtained with the dominating contributions visible in the one- and two-electron-removal channels. K-vacancy production in the encapsulated central nitrogen atom is seen in the single ionization of $\mathrm{Sc_3N@C_{80}^{+}}$ but is much less pronounced in the photoionization-with-fragmentation channel. Comparison of the cross sections near the carbon K edge with the corresponding channels measured previously in the photoionization of $\mathrm{Lu_3N@C_{80}^+}$ reveal strong similarities. Previously predicted sharp resonance features in the ionization of $\mathrm{Sc_3N@C_{80}^{+}}$ ions below the Sc M edge are not confirmed. Finally, the experiments are accompanied by quantum-chemistry calculations in the Hartree-Fock approximation and by model calculations employing density functional theory (DFT).

74 ATOMIC AND MOLECULAR PHYSICS↗

Laboratory astrophysics under the ultraviolet, visible, and gravitational astrophysics research program: Oscillator strengths for ultraviolet atomic transitions

The conditions within astrophysical environments can be derived from observational data on atomic and molecular lines. For instance, the density and temperature of the gas are obtained from relative populations among energy levels. Information on populations comes about only when the correspondence between line strength and abundance is well determined. The conversion from line strength to abundance involves knowledge of meanlives and oscillator strengths. For many ultraviolet atomic transitions, unfortunately, the necessary data are either relatively imprecise or not available. Because of the need for more and better atomic oscillator strengths, our program was initiated. Through beam-foil spectroscopy, meanlives of ultraviolet atomic transitions are studied. In this technique, a nearly isotopically pure ion beam of the desired element is accelerated. The beam passes through a thin carbon foil (2 mg/cu cm), where neutralization, ionization, and excitation take place. The dominant process depends on the energy of the beam. Upon exiting the foil, the decay of excited states is monitored via single-photon-counting techniques. The resulting decay curve yields a meanlife. The oscillator strength is easily obtained from the meanlife when no other decay channels are presented. When other channels are present, additional measurements or theoretical calculations are performed in order to extract an oscillator strength. During the past year, three atomic systems have been studied experimentally and/or theoretically; they are Ar, I, Cl I, and N II. The results for the first two are important for studies of interstellar space, while the work on N II bears on processes occurring in planetary atmospheres.

Federman, Steven R.↗

Single-pion contribution to the Gerasimov-Drell-Hearn sum rule and related integrals

Phenomenological amplitudes obtained in partial-wave analyses (PWA) of single-pion photoproduction are used to evaluate the contribution of this process to the Gerasimov-Drell-Hearn (GDH), Baldin and Gell-Mann-Goldberger-Thirring (GGT) sum rules, by integrating up to 2 GeV in photon energy. Here, our study confirms that the single-pion contribution to all these sum rules converges even before the highest considered photon energy, but the levels of saturation are very different in the three cases. Single-pion production almost saturates the GDH sum rule for the proton, while a large fraction is missing in the neutron case. The Baldin integrals for the proton and the neutron are both saturated to about four fifths of the predicted total strength. For the GGT sum rule, the wide variability in predictions precludes any definitive statement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗