Search NASA⌕ Search

SEARCH · Search NASA

Results for “space heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fabrication of carbon-carbon heat pipes for space nuclear power applications

Significant advancements have been made in the development of lightweight, high performance, carbon-carbon heat pipes for space nuclear power applications. The subject program has progressed through the concept definition and feasibility analysis stages to the current test article component fabrication and assembly phase. This concept utilizes a carbon-carbon tube with integrally woven fins as the primary structural element and radiative surface, Nb-1Zr liners to contain a potassium working fluid, and welded end caps and fill tubes. Various tests have been performed in the development of suitable liner bonding techniques and in the assessment of material stability.

Rovang, Richard D.↗

Excess liquid in heat-pipe vapor spaces

A mathematical model is developed of excess liquid in heat pipes that is used to calculate the parameters governing the axial flow of liquid in fillets and puddles that form in vapor spaces. In an acceleration field, the hydrostatic pressure variation is taken into account, which results in noncircular meniscus shapes. The two specific vapor-space geometries considered are circular and the 'Dee-shape' that is formed by a slab wick in a circular tube. Also presented are theoretical and experimental results for the conditions under which liquid slugs form at the ends of the vapor spaces. These results also apply to the priming of arteries.

Eninger, J. E.↗

Characterizing Microfluidic Operations Underlying an Electrowetting Heat Pipe on the International Space Station

Electrowetting heat pipes (EHPs) are a newly conceptualized class of heat pipes, wherein the adiabatic wick section is replaced by electrowetting-based pumping of the condensate (as droplets) to the evaporator. Specific advantages include the ability to transport high heat loads over long distances, low thermal resistance and power consumption, and the absence of moving mechanical parts. In this work, we describe characterization of key microfluidic operations (droplet motion and splitting) underlying the EHP on the International Space Station (ISS). The testing was performed under the Advanced Passive Thermal eXperiment (APTx) project, a project to test a suite of passive thermal control devices funded by the ISS Technology Demonstration Office at NASA JSC (Johnson Space Center). A rapid manufacturing method was used to fabricate the electrowetting device on a printed circuit board. Key device-related considerations were to ensure reliability and package the experimental hardware within a confined space. Onboard the ISS, experiments were conducted to study electrowetting-based droplet motion and droplet splitting, by imaging droplet manipulation operations via pre-programmed electrical actuation sequences. An applied electric field of 36 Volts per micron resulted in droplet speeds approaching 10 millimeters per second. Droplet splitting dynamics were observed and the time required to split droplets was quantified. Droplet motion data was analyzed to estimate the contact line friction coefficient. Overall, this demonstration is the first-ever electrowetting experiment in space. The obtained results are useful for future design of the EHP and other electrowetting-based systems for microgravity applications.

Electrowetting↗

Flow and heat transfer in space vehicle tile gaps

The flow patterns and the characteristics of the convective heat transfer in intersecting tile gaps on space vehicles were experimentally investigated using a water channel flow facility for simulating flow conditions in the tile gaps on the Aeroassist Flight Experiment (AFE) vehicle. It was found that penetration of external flow into the perpendicular gap was limited in most cases to roughly two gap widths, while greater entrainment occurred in the parallel gap. Heat transfer in the bulk of the perpendicular gap occurred by natural convection. The Reynolds number and the relative tile-height differences had the strongest influence on heat transfer and affected both the magnitude and the symmetry of the temperature and the flow fields.

Garimella, S. V.↗

Analysis of microwave-heated rocket engines for space propulsion

Microwave-heated plasmas in convergent nozzles are analyzed using a coupled Maxwell and Navier-Stokes solver to examine relevant issues associated with microwave thermal propulsion. Parametric studies are conducted to understand the effect of power, pressure, and plasma location with respect to the nozzle throat. For nozzles in the 0.5 to 3 N range with helium flow, results show that specific impulses up to 550-650 sec are possible, with further increases being limited by severe wall-heating. Coupling efficiencies of over 90 percent are consistently obtained, with overall efficiencies ranging from 40 percent to 80 percent. Size scale-up studies (done by scaling the frequency from 2.45 GHz to 0.91 GHz) indicate that plasma migration toward the walls occurs more frequently for the lower frequency. Increasing the cavity aspect ratio and detuning the cavity are found to be effective ways of keeping the plasma on-axis.

Schwer, D. A.↗

Assessment of CFD Hypersonic Turbulent Heating Rates for Space Shuttle Orbiter

Turbulent CFD codes are assessed for the prediction of convective heat transfer rates at turbulent, hypersonic conditions. Algebraic turbulence models are used within the DPLR and LAURA CFD codes. The benchmark heat transfer rates are derived from thermocouple measurements of the Space Shuttle orbiter Discovery windward tiles during the STS-119 and STS-128 entries. The thermocouples were located underneath the reaction-cured glass coating on the thermal protection tiles. Boundary layer transition flight experiments conducted during both of those entries promoted turbulent flow at unusually high Mach numbers, with the present analysis considering Mach 10{15. Similar prior comparisons of CFD predictions directly to the flight temperature measurements were unsatisfactory, showing diverging trends between prediction and measurement for Mach numbers greater than 11. In the prior work, surface temperatures and convective heat transfer rates had been assumed to be in radiative equilibrium. The present work employs a one-dimensional time-accurate conduction analysis to relate measured temperatures to surface heat transfer rates, removing heat soak lag from the flight data, in order to better assess the predictive accuracy of the numerical models. The turbulent CFD shows good agreement for turbulent fuselage flow up to Mach 13. But on the wing in the wake of the boundary layer trip, the inclusion of tile conduction effects does not explain the prior observed discrepancy in trends between simulation and experiment; the flight heat transfer measurements are roughly constant over Mach 11-15, versus an increasing trend with Mach number from the CFD.

Wood, William A.↗

Space Shuttle base heating

First-stage and second-stage heating environments of the base region of the Space Shuttle are characterized in detail in terms of Orbiter-main-engine-plume and booster-plume radiation, freestream-air convective cooling, and reversed-plume-flow convective heating as they affect each base-region design point. Design predictions are compared with selected heating-rate data from flights STS-1 through STS-5; the flight data are found to show excellent interflight repeatability independent of small changes in trajectory, and to verify the validity of the prediction methodology. The impact of individual flight events on base heating is indicated.

Greenwood, T. F.↗

Absorption heat pump for space applications

In the first part, the performance of the Absorption Heat Pump (AHP) with water-sulfuric acid and water-magnesium chloride as two new refrigerant-absorbent fluid pairs was investigated. A model was proposed for the analysis of the new working pairs in a heat pump system, subject to different temperature lifts. Computer codes were developed to calculate the Coefficient of Performance (COP) of the system with the thermodynamic properties of the working fluids obtained from the literature. The study shows the potential of water-sulfuric acid as a satisfactory replacement for water-lithium bromide in the targeted temperature range. The performance of the AHP using water-magnesium chloride as refrigerant-absorbent pair does not compare well with those obtained using water-lithium bromide. The second part concentrated on the design and testing of a simple ElectroHydrodynamic (EHD) Pump. A theoretical design model based on continuum electromechanics was analyzed to predict the performance characteristics of the EHD pump to circulate the fluid in the absorption heat pump. A numerical method of solving the governing equations was established to predict the velocity profile, pressure - flow rate relationship and efficiency of the pump. The predicted operational characteristics of the EHD pump is comparable to that of turbomachinery hardware; however, the overall efficiency of the electromagnetic pump is much lower. An experimental investigation to verify the numerical results was conducted. The pressure - flow rate performance characteristics and overall efficiency of the pump obtained experimentally agree well with the theoretical model.

Nguyen, Tuan↗

Heating measurements on Space Shuttle Orbiter models with differentially deflected elevons

The phase-change paint technique was used to make heat-transfer measurements on five Space Shuttle Orbiter models with differentially-deflected elevons. The outboard elevons were deflected windward through an angle delta when the inboard elevons were deflected through an angle - 2delta, where delta = 0, 5, 10, 15, and 20 deg. The models were tested in air at Mach 6 and Mach 10 with two different flow conditions at each Mach number. Each test was run at three angles of attack; 20, 28, and 35 deg. This study was restricted to the windward side of the wing/elevons area. Multiple chord-wise streaks of high heating often occurred on the wings and sometimes extended to localized spots of high heating on the windward-deflected elevons. The extent of heating was a function of angle of attack and test conditions, but in general differential deflection of the elevons affected the wing heat-transfer coefficient on the order of 40 percent or less whereas the windward elevon heat-transfer coefficient was a function of the deflection angle and could be many times the value determined for the undeflected elevon.

Wells, W. L.↗

Titanium-alloy, metallic-fluid heat pipes for space service

Reactivities of titanium limit its long-term terrestrial use for unprotected heat-pipe envelopes to about 870 K (1100 F). But this external thermochemical limitation disappears when considerations shift to space applications. In such hard-vacuum utilization much higher operating temperatures are possible. Primary restrictions in space environment result from vaporization, thermal creep, and internal compatibilities. Unfortunately, a respected head-pipe reference indicates that titanium is compatible only with cesium from the alkali-metal working-fluid family. This problem and others are subjects of the present paper which advocates titanium-alloy, metallic-fluid heat pipes for long-lived, weight-effective space service between 500 and 1300 K (440 and 1880 F).

Morris, J. F.↗

Evaluation of coated columbium alloy heat shields for space shuttle thermal protection system application. Volume 3, phase 3: Full size TPS evaluation

The thermal protection system (TPS), designed for incorporation with space shuttle orbiter systems, consists of one primary heat shield thermally and structurally isolated from the test fixture by eight peripheral guard panels, all encompassing an area of approximately 12 sq ft. TPS components include tee-stiffened Cb 752/R-512E heat shields, bi-metallic support posts, panel retainers, and high temperature insulation blankets. The vehicle primary structure was simulated by a titanium skin, frames, and stiffeners. Test procedures, manufacturing processes, and methods of analysis are fully documented. For Vol. 1, see N72-30948; for Vol. 2, see N74-15660.

Baer, J. W.↗

High thermal-transport capacity heat pipes for space radiators

This paper presents the results of performance tests of several dual-slot heat pipe test articles. The dual-slot configuration has a very high thermal transport capability and has been identified as a very promising candidate for the radiator system for the NASA Space Station solar dynamic power modules. Two six-foot long aluminum heat pipes were built and tested with ammonia and acetone. A 20-ft long heat pipe was also built and tested with ammonia. The test results have been compared with performance predictions. A thermal transport capacity of 2000 W at an adverse tilt of 1 in. and a 1000 W capacity at an adverse tilt of 2 in. were achieved on the 20-ft long heat pipe. These values are in close agreement with the predicted performance limits.

Carlson, Albert W.↗

Long titanium heat pipes for high-temperature space radiators

Titanium heat pipes are being developed to provide light weight, reliable heat rejection devices as an alternate radiator design for the Space Reactor Power System (SP-100). The radiator design includes 360 heat pipes, each of which is 5.2 m long and dissipates 3 kW of power at 775 K. The radiator heat pipes use potassium as the working fluid, have two screen arteries for fluid return, a roughened surface distributive wicking system, and a D shaped cross section container configuration. A prototype titanium heat pipe, 5.5 m long, was fabricated and tested in space simulating conditions. Results from startup and isothermal operation tests are presented. These results are also compared to theoretical performance predictions that were used to design the heat pipe initially.

Girrens, S. P.↗

Long titanium heat pipes for high-temperature space radiators

Titanium heat pipes are being developed to provide light weight, reliable heat rejection devices as an alternate radiator design for the Space Reactor Power System (SP-100). The radiator design includes 360 heat pipes, each of which is 5.2 m long and dissipates 3 kW of power at 775 K. The radiator heat pipes use potassium as the working fluid, have two screen arteries for fluid return, a roughened surface distributive wicking system, and a D-shaped cross-section container configuration. A prototype titanium heat pipe, 5.5-m long, has been fabricated and tested in space-simulating conditions. Results from startup and isothermal operation tests are presented. These results are also compared to theoretical performance predictions that were used to design the heat pipe initially.

Girrens, S. P.↗

Rewetting of Monogroove Heat Pipe in Space Station Radiators

Experimental investigation of the rewetting characteristics of a uniformly heated grooved surface was performed, the results of which are presented in this work. It was found that, for a rewetting fluid of 2-propanol, the rewetting temperature was approx. 93-96 C for the upward-facing case and about 2 C lower for the downwardfacing case. When the initial plate temperature was higher than the rewetting temperature, the rewetting speed decreased with the initial plate temperature. The rewetting speed is also faster in the upward-facing case than in the downward-facing case for the same initial plate temperatures, which indicates a gravitational effect on rewetting. This trend is found to be consistent with the previously investigated end heating condition. The rewetting distance that is predicted by the conduction controlled model is found to be in fair agreement with the experimental data. Also, an apparatus that enables experiments to be performed in a reduced gravitational environment has been built and experiments are currently being performed. The design of this apparatus is presented along with preliminary data.

Chan, S. H.↗

Heating measurements on Space Shuttle Orbiter models with differentially deflected elevons

The phase change paint technique was used to make heat transfer measurements on the windward wing/elevons area of Space Shuttle Orbiter models with differentially deflected elevons. Outboard elevons were deflected windward at angles from 0 to 20 deg. The inboard elevons were deflected leeward. The models were tested in air at Mach 6 and 10 with two flow conditions and three angles of attack for both Mach numbers. Heat transfer coefficient contour maps of the wing/elevon area were obtained for all test conditions. The maximum heat transfer coefficient on the outboard elevon and on certain areas of the wing that were obtained when the elevons were deflected are compared to values obtained when the elevons were undeflected.

Wells, W. L.↗