A theoretical and experimental study of light scattering in thermal control materials
Model relating spectral reflectance to thermal control materials properties and environment induced changes
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Model relating spectral reflectance to thermal control materials properties and environment induced changes
Application of thermoelectric devices as thermal control coatings for spacecraft
Formulation of electrically conductive, thermal-control coatings was undertaken for use on the International Sun Earth Explorer (ISEE) spacecraft. Unsuccessful formulation efforts as well as the successful use of oxide pigments fired at 1175 C are described. Problems attributed to reactivity of specific coating vehicles exposed to high humidity are discussed. Measurement and testing methods, including resulting data are mentioned, but the emphasis, in this report, is placed on coating formulation and application techniques. Methods of varying, as desired, optical properties are also described as well as formulations of white, low-absorptance coatings.
Silicate-bonded zinc orthotitanate thermal control coatings for space applications have been developed. This paper discusses preparation of the pigment, paint formulation and application, and some properties of the coatings. Very high reflectance (low solar absorptance), high emittance, and good stability in an ultraviolet-vacuum environment are indicated for this paint.
The Space Station Active Thermal Control System (ATCS) has been modeled using modified SINDA/SINFLO programs to solve two-phase Thermo-fluid problems. The modifications include changes in several subroutines to incorporate implicit solution which allows larger time step as compared to that for explicit solutions. Larger time step saves computer time but involves larger computational error. Several runs were made using various time steps for the ATCS model. It has been found that for a reasonable approach, three times larger time step as compared to that used in explicit method is a good value which will reduce the computer time by approximately 50 percent and still maintain the accuracy of the output data to within 90 percent of the explicit values.
The development of thermal control surfaces, which maintain stable solar absorptivity and infrared emissivity over long periods, is challenging due to severe conditions in low-Earth orbit (LEO). Some candidate coatings are second-surface silver-coated Teflon; second-surface, silvered optical solar reflectors made of glass or quartz; and anodized aluminum. Sulfuric acid anodized and oxalic acid anodized aluminum was evaluated under simulated LEO conditions. Oxalic acid anodizing shows promise of greater stability in LEO over long missions, such as the 30 years planned for the Space Station. However, sulfuric acid anodizing shows lower solar absorptivity.
The Two-Phase Flow Thermal Control Experiment is part of the NASA/OAST In-Space Technology Experiments (In-STEP) Program. The experiment is configured for the Hitchhiker Shuttle payload system and consists of a capillary pumped loop, heatpipe radiator, and two-phase flow heat exchanger. The flight experiment design approach, test plan, payload design, and test components are described in outline and graphic form.
A controlled thermal coefficient product manufacturing system and method is disclosed. The disclosed product relates to the manufacture of metallic material product (MMP) having a thermal expansion coefficient (TEC) in a predetermined range. The disclosed system and method provides for a first material deformation (FMD) of the MMP that comprises at least some of a first material phase (FMP) wherein the FMP comprises martensite randomly oriented and a first thermal expansion coefficient (FTC). In response to the FMD at least some of the FMP is oriented in at least one predetermined orientation. Subsequent to deformation, the MMP comprises a second thermal expansion coefficient (STC) that is within a predetermined range and wherein the thermal expansion of the MMP is in at least one predetermined direction. The MMP may be comprised of a second material phase (SMP) that may or may not transform to the FMP in response to the FMD.
A controlled thermal coefficient product manufacturing system and method is disclosed. The disclosed product relates to the manufacture of metallic material product (MMP) having a thermal expansion coefficient (TEC) in a predetermined range. The disclosed system and method provides for a first material deformation (FMD) of the MMP that comprises at least some of a first material phase (FMP) wherein the FMP comprises martensite randomly oriented and a first thermal expansion coefficient (FTC). In response to the FMD at least some of the FMP is oriented in at least one predetermined orientation. Subsequent to deformation, the MMP comprises a second thermal expansion coefficient (STC) that is within a predetermined range and wherein the thermal expansion of the MMP is in at least one predetermined direction. The MMP may be comprised of a second material phase (SMP) that may or may not transform to the FMP in response to the FMD.
Results are presented for an investigation intended to examine the orbital averaged thermal response of a number of instruments, each being representative of a class of scientific instrumentation, when they are individually mounted on pallets and operated in the cargo bay of the Shuttle. The discussion covers mainly the Shuttle Orbiter thermal models, the solar viewing instrument, and the high-energy instrument. One approach to thermal insulation of smaller instruments is to provide a thermal canister insulated from the cargo bay and equipped with variable conductance heat pipes. Two approaches are proposed for larger instruments. One approach is to provide a thermal curtain across the top of the pallet which shields the pallet cavity from direct sunlight, while the second approach is to provide a fluid system to transfer heat from a specified location on an instrument to either a space viewing radiator on the pallet or instrument or the orbiter cooling system. These thermal control design concepts represent several ideas for standard reusable thermal control systems.
The characterization of polymeric films and thermal control coatings which were exposed for five years and ten months to the low-Earth environment is reported. Changes in solar absorptance, thermal emittance, and transmission are compared to laboratory control specimens. Sputter-deposited metallic coatings are shown to eliminate atomic oxygen erosion of resin matrix composite materials. The effects of long-term atomic oxygen exposure to metallized FEP Teflon film is characterized. Chemical characterization of polymeric films indicates that although surface erosion occurs, the molecular structure of the basic polymeric film has not changed significantly in response to this exposure.
A summary is given of a series of thermal vacuum tests designed to support the development of the orbiter active thermal control system (ATCS) and included testing of a wide heat load range modular radiator system (MRS) configured to the March 1973 orbiter baseline system, a candidate weight reducing radiator/water cooling system, and a smaller radiator system with a high performance radiator coating. The tests verified the performance of the baseline system and obtained detailed design information for application of a wide heat load range modular radiator system to the orbiter. The two candidate ATCS weight reducing designs have undergone extensive concept verification testing and their system operating characteristics have been determined in sufficient detail for application to the orbiter. Design information has been obtained for an integrated radiator/water cooling system that provides for vehicle heat rejection as well as water management of the excess fuel cell water. Processing techniques have been developed and verified for the application of a high performance thermal control coating to large radiator areas subjected to a temperature range of -280 F to +160 F.
NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database are investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components is used as an example in this study.
NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies4,5 at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database were investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components was used as an example in this study.
Flight samples and control samples of optical and thermal control coatings were measured for hemispheric reflectance and transmission. The samples were exposed directly to the orbital environment, but were on the trailing edge of the LDEF satellite. Preliminary analysis shows no significant change in the reflectance of transmission values of most of the samples. Post-flight tests of avalanche photodiodes is also discussed.
Flight samples and control samples of optical and thermal control coatings have been measured for hemispheric reflectance and transmission. Data was recorded for wavelengths from .25 microns to 18 microns. The samples were exposed directly to the orbital environment, but were on the trailing edge of the LDEF satellite. Preliminary analysis shows no significant change in the reflectance or transmission values of most of the samples. Post-flight tests of avalanche photodiodes have yielded results. The tests consist of measuring the following detector parameters: breakdown voltage for set values of reverse current, responsivity vs. bias voltage, noise equivalent power, and uniformity of photoresponse. The avalanche photodiodes were mounted on the leading edge of the LDEF satellite, but were shielded from the outside by a silver-coated teflon foil cover. Small puncture holes are present in the foil, probably caused by impact of particles in orbit. For most of the detectors, there has been no significant change in noise or response.
The investigation of the feasibility of using a membrane device as a water boiler for thermal control is reported. The membrane device permits water vapor to escape to the vacuum of space but prevents the loss of liquid water. The vaporization of the water provides cooling to the water loop. This type of cooling device would have application for various types of short duration cooling needs where expenditure of water is allowed and a low pressure source is available such as in space or on a planet's surface. A variety of membrane samples, both hydrophilic and hydrophobic, were purchased to test for this thermal control application. An initial screening test determined if the membrane could pose a sufficient barrier to maintain water against vacuum. Further testing compared the heat transfer performance of those membranes that passed the screening test.
One of the important issues in the design of a lunar base is the thermal control system (TCS) used to reject low-temperature heat from the base. The TCS ensures that the base and the components inside are maintained within an acceptable temperature range. The temperature of the lunar surface peaks at 400 K during the 336-hour lunar day. Under these circumstances, direct dissipation of waste heat from the lunar base using passive radiators would be impractical. Thermal control systems based on thermal storage, shaded radiators, and heat pumps have been proposed. Based on proven technology, innovation, realistic complexity, reliability, and near-term applicability, a heat pump-based TCS was selected as a candidate for early missions. In this report, Rankine-cycle heat pumps and absorption heat pumps (ammonia water and lithium bromide-water) have been analyzed and optimized for a lunar base cooling load of 100 kW.