Search NASA⌕ Search

SEARCH · Search NASA

Results for “waveform analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A comparative study of lock-in-amplifiers and improved duffing chaotic oscillators for the detection and processing of weak signals

The measurement of multiphase flow parameters is of great importance in a wide range of industries. In the measurement of multiphase, the signals from the sensors are extremely weak and often buried in strong background noise. It is thus desirable to develop effective signal processing techniques that can detect the weak signal from the sensor outputs. In this paper, two methods, i.e., lock-in-amplifier (LIA) and improved Duffing chaotic oscillator are compared to detect and process the weak signal. For sinusoidal signal buried in noise, the correlation detection with sinusoidal reference signal is simulated by using LIA. The improved Duffing chaotic oscillator method, which based on the Wigner transformation, can restore the signal waveform and detect the frequency. Two methods are combined to detect and extract the weak signal. Simulation results show the effectiveness and accuracy of the proposed improved method. The comparative analysis shows that the improved Duffing chaotic oscillator method can restrain noise strongly since it is sensitive to initial conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Dead-Time Effects in a WPT System Inverter for Different Fixed-Frequency Modulation Techniques

In this paper, a comparative study of the dead-time effects in a wireless power transfer (WPT) system inverter is performed for different fixed-frequency control techniques. The dead-time is provided between the complementary switching instances of the inverter phase-legs to ensure safe operation of the input power source. Under certain operating conditions, the dead-time results in waveform distortions or voltage-polarity reversal (VPR) at the inverter output. The VPR affects the switching characteristics, harmonic spectrum, switching losses, and output voltage/power of the system. A detailed analysis of the dead-time effect on the WPT system parameters such as output voltage and output power is conducted for the different fixed-frequency control strategies (i.e., traditional phase-shift control, asymmetrical clamped-mode, and asymmetrical duty-cycle control). Furthermore, the impact of dead-time on the inverter switching losses is compared for the different control strategies.

Kavimandan, Utkarsh↗

High-speed, multi-channel detector readout electronics for fast radiation detectors

In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps, MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications.The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the SHARC DSP has been booted with preliminary code. All new ICs and circuitry on the prototype are working properly, however some of the planned firmware and software functions have not yet been completely implemented and debugged. Overall, due to the unanticipated complexity of the PCI Express interface, some aspects of the project could not be completed with the time and funds available in Phase II. These aspects will be completed in self-funded Phase III.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PSR J0030+0451 Mass and Radius from NICER Data and Implications for the Properties of Neutron Star Matter

Neutron stars are not only of astrophysical interest, but are also of great interest to nuclear physicists because their attributes can be used to determine the properties of the dense matter in their cores. One of the most informative approaches for determining the equation of state (EoS) of this dense matter is to measure both a star's equatorial circumferential radius R e and its gravitational mass M. Here we report estimates of the mass and radius of the isolated 205.53 Hz millisecond pulsar PSR J0030+0451 obtained using a Bayesian inference approach to analyze its energy-dependent thermal X-ray waveform, which was observed using the Neutron Star Interior Composition Explorer (NICER). This approach is thought to be less subject to systematic errors than other approaches for estimating neutron star radii. We explored a variety of emission patterns on the stellar surface. In this work, our best-fit model has three oval, uniform-temperature emitting spots and provides an excellent description of the pulse waveform observed using NICER. The radius and mass estimates given by this model are ${R}_{e}={13.02}_{-1.06}^{+1.24}$ km and $M={1.44}_{-0.14}^{+0.15}\,{M}_{\odot }$ (68%). The independent analysis reported in the companion paper by Riley et al. explores different emitting spot models, but finds spot shapes and locations and estimates of R e and M that are consistent with those found in this work. We show that our measurements of R e and M for PSR J0030+0451 improve the astrophysical constraints on the EoS of cold, catalyzed matter above nuclear saturation density.

79 ASTRONOMY AND ASTROPHYSICS↗

Note: The intermodulation lockin analyzer

Nonlinear systems can be probed by driving them with two or more pure tones while measuring the intermodulation products of the drive tones in the response. We describe a digital lockin analyzer which is designed explicitly for this purpose. The analyzer is implemented on a field-programmable gate array, providing speed in analysis, real-time feedback, and stability in operation. The use of the analyzer is demonstrated for intermodulation atomic force microscopy. A generalization of the intermodulation spectral technique to arbitrary drive waveforms is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IDC Re-Engineering Phase 2 System Requirements Document V1.3.

This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data but includes requirements for the dissemination of radionuclide data and products.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

IDC Re-Engineering Phase 2 System Requirements Document Version 1.4

This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data, but includes requirements for the dissemination of radionuclide data and products.

97 MATHEMATICS AND COMPUTING↗

Interparameter trade-off quantification and reduction in isotropic-elastic full-waveform inversion: synthetic experiments and Hussar land data set application

The problem of inverting for multiple physical parameters in the subsurface using seismic full-waveform inversion (FWI) is complicated by interparameter trade-off arising from inherent ambiguities between different physical parameters. Parameter resolution is often characterized using scattering radiation patterns, but these neglect some important aspects of interparameter trade-off. More general analysis and mitigation of interparameter trade-off in isotropic-elastic FWI is possible through judiciously chosen multiparameter Hessian matrix-vector products. We show that products of multiparameter Hessian off-diagonal blocks with model perturbation vectors, referred to as interparameter contamination kernels , are central to the approach. We then apply the multiparameter Hessian to various vectors designed to provide information regarding the strengths and characteristics of interparameter contamination, both locally and within the whole volume. With numerical experiments, we observe that S-wave velocity perturbations introduce strong contaminations into density and phase-reversed contaminations into P-wave velocity, but themselves experience only limited contaminations from other parameters. Based on these findings, we introduce a novel strategy to mitigate the influence of interparameter trade-off with approximate contamination kernels. Furthermore, we recommend that the local spatial and interparameter trade-off of the inverted models be quantified using extended multiparameter point spread functions (EMPSFs) obtained with pre-conditioned conjugate-gradient algorithm. Compared to traditional point spread functions, the EMPSFs appear to provide more accurate measurements for resolution analysis, by de-blurring the estimations, scaling magnitudes and mitigating interparameter contamination. Approximate eigenvalue volumes constructed with stochastic probing approach are proposed to evaluate the resolution of the inverted models within the whole model. With a synthetic Marmousi model example and a land seismic field data set from Hussar, Alberta, Canada, we confirm that the new inversion strategy suppresses the interparameter contamination effectively and provides more reliable density estimations in isotropic-elastic FWI as compared to standard simultaneous inversion approach.

58 GEOSCIENCES↗

Joint Inversion of Regional Waveform, First-Motion Polarity, and Synthetic Aperture Radar Surface Displacement for the Fourth and Sixth North Korean Declared Nuclear Explosions

Here, this study analyzed the Democratic People’s Republic of Korea’s (DPRK) fourth (DPRK4, 6 January 2016 M w 4.49) and sixth (DPRK6, 7 September 2017 M w 5.2) declared nuclear tests, employing a joint seismic and Interferometric Synthetic Aperture Radar (InSAR) inversion to improve understanding of these events and enhance moment tensor (MT) inversion capabilities. The recent efforts have focused on employing seismic waveform and InSAR geodetic deformation data separately to analyze these and the previous nuclear tests (e.g., Chiang et al., 2018; Myers et al., 2018; Wang et al., 2018). Building upon our previous work (Chi-Durán et al., 2021), we performed a joint regional waveform, first-motion (FM) polarity, and surface displacement inversion, which demonstrated improved source-type discrimination, a revised MT solution with reduced scalar moment uncertainty, and an independently constrained location. In this article, we build on the previous results for DPRK6 by including an analysis using a four-layered velocity model with free-surface topography to compute the near-source static deformation Green’s functions. The model consists of a 50 m basalt layer (⁠V P = 2.07 km/s, V S = 1.2 km/s⁠), a 250 m stratified volcanic deposit layer (⁠V P = 1.73 km/s, V S = 1.0 km/s⁠), a 700 m weathered granodiorite layer (⁠V P = 2.5 km/s, V S = 1.3 km/s⁠⁠), and a granodiorite half-space (⁠V P = 5.35 km/s, V S = 3.09 km/s⁠⁠). The half-space shares the velocity of the regional MDJ2 velocity model (Ford et al., 2010), which has proven effective for waveform inversion in the region. This model considers the range of reported values for various lithologies and weathering effects. Our findings show that using the layered velocity model enhances the recovery of source location and depth for both the explosions by improving fits and reducing uncertainties. The joint inversion also improves source-type discrimination and better constrains the scalar seismic moment necessary for downstream yield estimation.

58 GEOSCIENCES↗

SU-F-303-10: Impact of Visual Biofeedback On Respiratory Reproducibility in 4DMRI

Purpose: Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4DCT. 4DMRI offers improved contrast. However, long scan times and irregular breathing patterns can be limiting. To address this, we introduced visual biofeedback (VBF) into 4DMRI. Methods: Eight healthy volunteers were consented to an IRB-approved protocol. Prospective respiratory-triggered, T2-weighted coronal 4DMRIs were acquired on an open 1.0T MR- SIM. VBF was integrated using an MR-compatible interactive breath-hold control system. Subjects visually monitored their breathing patterns to stay within pre-determined tolerances. 4DMRIs were acquired with and without VBF for 2–8 phase acquisitions. Normalized respiratory waveforms were evaluated for scan time, duty cycle (programmed/acquisition time), breathing period, end-inhale (EI) amplitude, and breathing variability (coefficient of variation, EI-COV). B-spline-based deformable image registration propagated contours from end-exhale (EE) to EI phases. Respiration-induced liver motion was calculated via centroid analysis and compared. Results: Incorporating VBF reduced 2-phase acquisition time (4.7±0.6 and 5.6±1.4 minutes with and without VBF, respectively) while reducing the amplitude EI-COV by 53.0±8.1%. On average, incorporating VBF reduced 8-phase 4DMRI acquisition times by 1.7±1.2 minutes and EI-COVs by 46.0±15.8%. Using VBF yielded higher duty cycles than free breathing (34.7% versus 28.3%, respectively). 4DMRI acquisition time was reduced for the cohort with VBF despite breathing rate remaining similar (10.5±4.0 with vs. 10.6±3.3 BPM without). Respiratory waveforms showed higher EI amplitude with VBF (0.84±0.05 a.u.) as compared to 0.72±0.06 a.u. without. This translated to differences in liver excursions, where superior-inferior, anterior-posterior, and left-right EE-EI displacements were 14.3±3.6, 4.8±2.1, and 1.6±1.0 mm, respectively, with VBF compared to 13.0±6.2, 3.8±2.4, and 1.2±1.4 mm without. Conclusion: Incorporating VBF system into 4DMRI substantially reduced acquisition time and breathing variability. While VBF reduced liver motion variability, differences in excursion were observed, suggesting that implementation will be required throughout the RT workflow. Research supported in part by a grant from Philips HealthCare (Best, Netherlands) and an equipment evaluation agreement with MedSpira.

60 APPLIED LIFE SCIENCES↗

Short-Circuit Characterization and Protection of 10-kV SiC mosfet

This paper presents the characterization of the temperature-dependent short-circuit performance of a Gen3 10 kV/20 A silicon carbide (SiC) mosfet. The test platform consisting of a phase-leg configuration and a fast speed 10-kV solid state circuit breaker, with temperature control, is introduced in detail. A novel FPGA-based short-circuit protection circuit having a response time of 1.5 μs is proposed and integrated into the gate driver. The short-circuit protection is validated through the platform. The short-circuit characteristics for both the hard switching fault and fault under load (FUL) types at various dc-link voltages (from 500 V to 6 kV) are tested and discussed. The saturation current increases with dc-link voltage and achieves 360 A at 6 kV. Different from low voltage SiC devices, there is no current spike in FUL type of fault. The temperature-dependent short-circuit performance is also presented from 25 to 125 °C. The difference of short-circuit waveforms at various initial junction temperatures can be neglected. Here, a thermal model of the 10-kV SiC mosfet is built for the junction temperature estimation during the short circuit and for analysis of the initial junction temperature impact on the short-circuit performance.

10-kV SiC mosfet↗

Characterization of the plasma current quench during disruptions in the National Spherical Torus Experiment

A detailed analysis of the plasma current quench in the National Spherical Torus Experiment [M.Ono, et al Nuclear Fusion 40, 557 (2000)] is presented. The fastest current quenches are fit better by a linear waveform than an exponential one. Area-normalized current quench times down to .4 msec/m2 have been observed, compared to the minimum of 1.7 msec/m2 recommendation based on conventional aspect ratio tokamaks; as noted in previous ITPA studies, the difference can be explained by the reduced self-inductance at low aspect ratio and high-elongation. The maximum instantaneous dIp/dt is often many times larger than the mean quench rate, and the plasma current before the disruption is often substantially less than the flat-top value. The poloidal field time-derivative during the disruption, which is directly responsible for driving eddy currents, has been recorded at various locations around the vessel. The Ip quench rate, plasma motion, and magnetic geometry all play important roles in determining the rate of poloidal field change.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring the limits of waveform correlation event detection as applied to three earthquake aftershock sequences.

Swarms of earthquakes and/or aftershock sequences can dramatically increase the level of seismicity in a region for a period of time lasting from days to months, depending on the swarm or sequence. Such occurrences can provide a large amount of useful information to seismologists. For those who monitor seismic events for possible nuclear explosions, however, these swarms/sequences are a nuisance. In an explosion monitoring system, each event must be treated as a possible nuclear test until it can be proven, to a high degree of confidence, not to be. Seismic events recorded by the same station with highly correlated waveforms almost certainly have a similar location and source type, so clusters of events within a swarm can quickly be identified as earthquakes. We have developed a number of tools that can be used to exploit the high degree of waveform similarity expected to be associated with swarms/sequences. Dendro Tool measures correlations between known events. The Waveform Correlation Detector is intended to act as a detector, finding events in raw data which correlate with known events. The Self Scanner is used to find all correlated segments within a raw data steam and does not require an event library. All three techniques together provide an opportunity to study the similarities of events in an aftershock sequence in different ways. To comprehensively characterize the benefits and limits of waveform correlation techniques, we studied 3 aftershock sequences, using our 3 tools, at multiple stations. We explored the effects of station distance and event magnitudes on correlation results. Lastly, we show the reduction in detection threshold and analyst workload offered by waveform correlation techniques compared to STA/LTA based detection. We analyzed 4 days of data from each aftershock sequence using all three methods. Most known events clustered in a similar manner across the toolsets. Up to 25% of catalogued events were found to be a member of a cluster. In addition, the Waveform Correlation Detector and Self Scanner identified significant numbers of new events that were not in either the EDR or regional catalogs, showing a lowering of the detection threshold. We extended our analysis to study the effect of distance on correlation results by applying the analysis tools to multiple stations along a transect of nearly constant azimuth when possible. We expected the number of events found via correlation would drop off as roughly 1/r2, where r is the distance from mainshock to station. However, we found that regional geological conditions influenced the performance of a given station more than distance. For example, for one sequence we clustered 25% of events at the nearest station to the mainshock (34 km), while our performance dropped to 2% at a station 550 km distant. However, we matched our best performance (25% clustering) at a station 198 km distant.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Integration of paper spray ionization high‐field asymmetric waveform ion mobility spectrometry for forensic applications

Rationale Paper spray ionization (PSI) is an attractive ambient ionization source for mass spectrometry (MS) since it allows the combination of surface sampling and ionization. The minimal sample preparation inherent in this approach greatly reduces the time needed for analysis. However, the ions generated from interfering compounds in the sample and the paper substrate may interfere with the analyte ions. Therefore, the integration of PSI with high‐field asymmetric ion mobility spectrometry (FAIMS) is of significant interest since it should reduce the background ions entering the mass analyzer without complicating the analysis or increasing analysis time. Here we demonstrate the integration of PSI with FAIMS/MS and its potential for analysis of samples of forensic interest. Methods In this work, the parameters that can influence the integration, including sampling and ionization by paper spray, the FAIMS separation of analytes from each other and background interferences, and the length of time that a usable signal can be observed for explosives on paper, were evaluated with the integrated system. Results In the negative ion analysis of 2,4,6‐trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), octahydro‐1,3,5,7‐tetranitro‐1,3,5,7‐tetrazocine (HMX), and 1,3,5‐trinitroperhydro‐1,3,5‐triazine (RDX), amounts as low as 1 ng on paper were readily observed. The successful positive ion separation of a set of illicit drugs including heroin, methamphetamine, and cocaine was also achieved. In addition, the positive ion analysis of the chemical warfare agent simulants dimethyl methylphosphonate (DMMP) and diisopropyl methylphosphonate (DIMP) was evaluated. Conclusions The integration of PSI‐FAIMS/MS was demonstrated for the analyses of explosives in negative ion mode and for illicit drugs and CW simulants in positive mode. Paper background ions that could interfere with these analyses were separated by FAIMS. The compensation voltage of an ion obtained by FAIMS provided an additional identification parameter to be combined with the mass spectrum for each analyte.

Tsai, Chia‐Wei↗

A machine learning framework for accurate and robust analysis of radiation detector pulses

The microscopic properties of atomic nuclei are used to study various scientific questions. They are essential for understanding the fundamental forces of nature and the chemical evolution of the universe. Detecting decay radiation from radioactive nuclei makes it possible to probe these fundamental nuclear properties. Detector waveform traces may contain additional information about the radiation. Generally, advanced signal processing techniques are needed to extract this additional information, often involving fitting the waveform with model response functions using non-linear least-squares optimization with second-order gradient methods. While this is a powerful technique, it is also computationally expensive, leading to slow processing time, which scales with the volume of data. To address this problem, we have developed a machine learning (ML) approach that infers the characteristics of traces from a model detector response function. In particular, we are interested in classifying whether a single recorded trace consists of one or two pulse constituents and estimating the pulse parameters. Furthermore, our proposed ML method can precisely extract the pulses’ parameters, such as energy and timing information, and accurately classify the pulse multiplicity of a trace. Unlike non-learning-based approaches, our ML approach uses neural networks that are significantly faster at inference, as they do not require any optimization during this stage.

Curve fitting↗

Note: An improved 3D imaging system for electron-electron coincidence measurements

We demonstrate an improved imaging system that can achieve highly efficient 3D detection of two electrons in coincidence. The imaging system is based on a fast frame complementary metal-oxide semiconductor camera and a high-speed waveform digitizer. We have shown previously that this detection system is capable of 3D detection of ions and electrons with good temporal and spatial resolution. Here, we show that with a new timing analysis algorithm, this system can achieve an unprecedented dead-time (<0.7 ns) and dead-space (<1 mm) when detecting two electrons. A true zero dead-time detection is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing infrasound observations for sample return capsule re-entry: Insights from OSIRIS-REx and Hayabusa2

The atmospheric entry of meteoroids presents a rare and unpredictable phenomenon, posing challenges for systematic observation and detailed characterization. Such events are nonetheless critical for advancing understanding of acoustic wave propagation, atmospheric structure, and entry dynamics. In contrast, sample return capsules (SRCs) from space missions follow well constrained re-entry trajectories, enabling planned observations of shock wave generation and propagation under controlled conditions. This study compares two SRC atmospheric entries, Hayabusa2 in 2020 and OSIRIS-REx in 2023, to assess how different infrasound array configurations influence shock wave detection and trajectory validation. Hayabusa2’s re-entry was monitored using a distributed network of 28 portable infrasound sensors across seven arrays in Woomera, Australia, permitting three-dimensional reconstruction of the trajectory and analysis of wave characteristics. For OSIRIS-REx, a compact four-sensor array deployed near Eureka Airport provided trajectory confirmation through arrival-time differences and back-azimuth estimates. Spectral and waveform analyses revealed differences in signal properties associated with variations in entry angle and velocity. The results illustrate both the strengths and the limitations of the deployed array configurations. The dense and distributed arrays during Hayabusa2’s re-entry enabled detailed trajectory reconstruction, whereas the compact array at Eureka primarily provided confirmation of signal coherence and back-azimuth consistency. These case studies highlight that even relatively small arrays, if located close to the predicted ground track, can still capture useful information on arrival direction and timing. Such insights provide practical guidance for planning future observational campaigns of SRC returns and other controlled atmospheric entries, and may also inform approaches to opportunistic observations of meteoroid events and other atmospheric acoustic phenomena.

celestial mechanics: orbit determination↗

EGS Collab Experiment 2: Microseismic Monitoring

This dataset contains continuous seismic waveform data recorded during stimulation and thermal circulation tests for the Enhanced Geothermal Systems (EGS) Collab Experiment #2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to study and validate models of geothermal systems by injecting high-pressure fluids into rock formations 1200-1500 meters below the surface, inducing microseismic events. The seismic monitoring system included 16 three-component accelerometers and a 24-channel hydrophone array, installed in boreholes surrounding the test area. Data were recorded at high sampling rates using a continuous waveform recording system to monitor seismic activity in real time. The dataset contains the raw data stored in binary format, with files named based on timestamps, and includes calibration certificates for some sensors to facilitate corrections to real units. Users are strongly advised to consult the accompanying detailed report, which outlines the experimental setup, sensor specifications, installation procedures, and data processing methods. The report also describes important nuances, such as the hardware filters on hydrophones, sensor calibration details, and the naming conventions for the recorded data. Proper use of this dataset may require familiarity with seismic data analysis tools, such as the Obspy Python package, and an understanding of the SEED naming conventions used for channel identification.

15 GEOTHERMAL ENERGY↗