Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerated beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The beam business: Accelerators in industry

Most physicists know that particle accelerators are widely used for treating cancer. But few are acquainted with the depth and breadth of their use in a myriad of applications outside of pure science and medicine. Society benefits from the use of particle beams in the areas of communications, transportation, the environment, security, health, and safety - in terms both of the global economy and quality of life. On the manufacturing level, the use of industrial accelerators has resulted in the faster and cheaper production of better parts for medical devices, automobiles, aircraft, and virtually all modern electronics. Consumers also benefit from the use of accelerators to explore for oil, gas, and minerals; sterilize food, wastewater, and medical supplies; and aid in the development of drugs and biomaterials.

07 ISOTOPE AND RADIATION SOURCES↗

Neutron interrogation systems using pyroelectric crystals and methods of preparation thereof

According to one embodiment, an apparatus includes a pyroelectric crystal, a deuterated or tritiated target, an ion source, and a common support coupled to the pyroelectric crystal, the deuterated or tritiated target, and the ion source. In another embodiment, a method includes producing a voltage of negative polarity on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target to produce a neutron beam, and directing the ion beam onto the deuterated or tritiated target to make neutrons using a voltage of the pyroelectric crystal and/or an HGI surrounding the pyroelectric crystal. The directionality of the neutron beam is controlled by changing the accelerating voltage of the system. Other apparatuses and methods are presented as well.

36 MATERIALS SCIENCE↗

Neutron generation using pyroelectric crystals

According to one embodiment, a method for producing a directed neutron beam includes producing a voltage of negative polarity of at least −100 keV on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal of less than about 40° C., the pyroelectric crystal having the deuterated or tritiated target coupled thereto, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target to produce a neutron beam, and directing the ion beam onto the deuterated or tritiated target to make neutrons using at least one of a voltage of the pyroelectric crystal, and a high gradient insulator (HGI) surrounding the pyroelectric crystal. The directionality of the neutron beam is controlled by changing the accelerating voltage of the system. Other methods are presented as well.

Tang, Vincent↗

Design Considerations for Plasma Accelerators Driven by Lasers or Particle Beams

Plasma accelerators may be driven by the ponderomotive force of an intense laser or the space-charge force of a charged particle beam. The implications for accelerator design and the different physical mechanisms of laser-driven and beam-driven plasma acceleration are discussed. Driver propagation is examined, as well as the effects of the excited plasma wave phase velocity. The driver coupling to subsequent plasma accelerator stages for high-energy physics applications is addressed.

43 PARTICLE ACCELERATORS↗

Two-beam, Multi-mode Detuned Accelerating Structure

A two-beam accelerator structure is described having several novel features including all metal construction, no transfer structures required between the drive and accelerator channels, symmetric fields at the axes of each channel, RF micropulse widths on cavity irises that are less than half those for a conventional cavity at the same fundamental frequency by virtue of using several harmonically-related cavity modes, and a transformer ratio much greater than unity by the use of detuned cavities. Detuning is also shown to allow either parallel or anti-parallel directions for the drive and accelerated beams. A preliminary calculation for the dilution of emittance due to short-range wakes for drive beam parameters similar to those for CLIC shows this effect to be acceptably small.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Need for portable accelerators in cultural heritage

Ion Beam Accelerators (IBA) centres have provided researchers with powerful techniques to analyse objects of cultural significance in a non-destructive and non-invasive manner. However, in some cases it is not feasible to remove an object from the field or museum and transport it to the laboratory. In this contributed talk, we present as a manner of a short review, examples of the benefits provided from these techniques in the study of material culture and discuss the initial steps to consider when investigating the feasibility of a compact accelerator that can be taken to sites of cultural significance for PIXE analysis. In particular, we consider the application of a compact, robust 2 MeV proton accelerator that can be taken into the field to perform PIXE measurements on rock art. We detail the main challenges and considerations for such a device.

Charles, T. K.↗

Fermilab Booster Transition Crossing Simulations and Beam Studies

The Fermilab Booster accelerates beam from 400 MeV to 8 GeV at 15 Hz. In the PIP (Proton Improvement Plan) era, it is required that Booster deliver 4.2 x $10^{12}$ protons per pulse to extraction. One of the obstacles for providing quality beam to the users is the longitudinal quadrupole oscillation that the beam suffers from right after transition. Although this oscillation is well taken care of with quadrupole dampers, it is important to understand the source of these oscillations in light of the PIP II requirements that require 6.5 x $10^{12}$ protons per pulse at extraction. This paper explores the results from machine studies, computer simulations and solutions to prevent the quadrupole oscillations after transition.

Bhat, C. M.↗

Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment

Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam image to accurately estimate the beam position under good image quality conditions. Depending on the features present in a particular beam, the analytical template allows us to create a highly tailored template containing only those selected features. The second objective is achieved by exploiting the parallelism inherent in the algorithm to accelerate processing using parallel hardware that provides significant performance improvement over conventional processors. In particular, a Xilinx Virtex II Pro FPGA hardware implementation processing 32 templates provided a speed increase of about 253 times over an optimized software implementation running on a 2.0 GHz AMD Opteron core.

42 ENGINEERING↗

Diagnostic of laser-accelerated ion beams for the ELIMED project

The laser-generated plasma, in non equilibrium conditions, has peculiar properties depending strongly on the laser parameters, on the target composition and on the target geometry. Different fast diagnostic techniques can be employed for the plasma characterization in terms of particles and photons emission, plasma temperature and density, ion energy distribution, angular emission, yield and electric field acceleration. Particular attention is devoted to the proton emission from hydrogenated targets and to the proton diagnostics by using time of flight techniques and Thomson parabola spectrometry. The diagnostic techniques will be presented and discussed on the base of the development of the ELIMED project.

43 PARTICLE ACCELERATORS↗

Voltage holding study of 1 MeV accelerator for ITER neutral beam injector

Voltage holding test on MeV accelerator indicated that sustainable voltage was a half of that of ideal quasi-Rogowski electrode. It was suggested that the emission of the clumps is enhanced by a local electric field concentration, which leads to discharge initiation at lower voltage. To reduce the electric field concentration in the MeV accelerator, gaps between the grid supports were expanded and curvature radii at the support corners were increased. After the modifications, the accelerator succeeded in sustaining -1 MV in vacuum without beam acceleration. However, the beam energy was still limited at a level of 900 keV with a beam current density of 150 A/m{sup 2} (346 mA) where the 3 x 5 apertures were used. Measurement of the beam profile revealed that deflection of the H{sup -} ions was large and a part of the H{sup -} ions was intercepted at the acceleration grid. This causes high heat load on the grids and the breakdowns during beam acceleration. To suppress the direct interception, new grid system was designed with proper aperture displacement based on a 3D beam trajectory analysis. As the result, the beam deflection was compensated and the voltage holding during the beam acceleration was improved. Beam parameter of the MeV accelerator was increased to 980 keV, 185 A/m{sup 2} (427 mA), which is close to the requirement of ITER accelerator (1 MeV, 200 A/m{sup 2}).

43 PARTICLE ACCELERATORS↗

Fast ion studies in the extended high-performance high β P plasma on EAST

Comprehending and optimizing fast ion behaviors is critical for the enhancement of performance in Experimental Advanced Superconducting Tokamak (EAST). This study explores the potential benefits of several factors that can improve the fast ion confinement. First, experiments show the change in the direction of the NBI2 from counter-I p to co-I p leads to a significant reduction in fast ion losses. TRANSP/NUBEAM simulation and tomography results based on fast-ion D-alpha measurements reveal that after the neutral beam injection (NBI) upgrade, the beam ion prompt loss is reduced by approximately 50%. Second, the upgraded ion cyclotron resonant frequency (ICRF) antenna at the N-port features twice the coupling resistance of the original antennas at EAST. This improved ICRF power coupling has enhanced the synergistic heating effect of NBI + ICRF, where the ICRF wave field accelerates beam ions at the harmonics. Experiments demonstrate that NBI + ICRF synergistic not only enhances plasma neutron yield and β P , but also accelerates beam ions to hundreds of keV. Further, the electron density and the neutral beam voltage have been optimized to reduce the fast ion slowing-down time and beam ion losses. Experimental and simulation results indicate that increasing the electron density reduces beam ion losses and enhances the bootstrap current fraction. While higher beam voltage results in a slight decrease in beam power absorption, it can increase the fraction of bootstrap current. With the understanding of these optimization of fast ion confinement, experiments have demonstrated fully non-inductive operation at high density (n e /n G ∼ 0.67, β P ∼ 3.1, β N ∼ 2.1, H 98,y2 ∼ 1.2) even without the support of co-I p beam NBI2. This investigation presents a potential regime to enhance fast ion confinement and extend performance in the high β P plasma for future experiments.

EAST tokamak↗

Search for Muon Neutrino Disappearance in a Short-Baseline Accelerator Neutrino Beam

We report a search for muon neutrino disappearance in the {Delta}m{sup 2} region of 0.5--40 eV{sup 2} using data from both Sci-BooNE and MiniBooNE experiments. SciBooNE data provides a constraint on the neutrino flux, so that the sensitivity to {nu}{sub {mu}} disappearance with both detectors is better than with just MiniBooNE alone. The preliminary sensitivity for a joint {nu}{sub {mu}} disappearance search is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for muon neutrion disappearance in a short-baseline accelerator neutrino beam

Neutrino oscillations have been observed and confirmed at {Delta}m{sup 2} {approx} 10{sup -3} and 10{sup -5} eV{sup 2} with various experiments. While oscillations at other mass splittings are prohibited by the current standard model, the LSND experiment observed an excess of electron antineutrinos in a muon antineutrino beam, indicating a possible oscillation at {Delta}m{sup 2} {approx} 1 eV{sup 2}. To test the oscillation at {Delta}m{sup 2} {approx} 1 eV{sup 2}, we search for muon neutrino disappearance using the Fermilab Booster Neutrino beamline and two experiments, SciBooNE and MiniBooNE. The neutrino fluxes are measured in the SciBooNE and MiniBooNE detectors, located at 100 m and 540 m downstream from the neutrino production target, respectively. We collected beam data from June 2007 through August 2008 with SciBooNE, and over a five year period with MiniBooNE. A preliminary sensitivity for a joint v{sub {mu}} disappearance search is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photocathode Laser Shaping for High Transformer Ratio Collinear Wakefield Acceleration

Beam-driven wakefield acceleration is one of the most promising advanced accelerator concepts. With this approach, the main beam is accelerated by absorbing the energy from a drive beam, which has a lower kinetic energy, but a much higher current. For efficient acceleration, it is important to shape the drive beam axially, to increase the so-called transformer ratio: the energy gain by the main beam over the energy loss of the drive beam. In most cases, the drive beam shaping is done with the help of beam phase space manipulations, along with removing portions of the beam with a scraper. Such shaping is complicated by itself, causing charge loss and thermal heating, but can also lead to beam instabilities, due to the alteration of the beam phase space. How the problem is being addressed: In this project, Euclid Techlabs proposes to reduce the complexity of this process by shaping the laser beam incident on the photocathode instead of the electron beam itself. This approach yields an additional “tuning knob” for shaping the electron beam. The photocathode laser pulse can be modified to have the desired longitudinal profile, which will result in the desired profile of the electron beam after acceleration in the photoinjector. Laser shaping is, in fact, analogous to previous electron beam shaping approaches. A chirped beam is passed through a dispersive element (spatial light modulator), and masked to achieve the desired shape.

43 PARTICLE ACCELERATORS↗

Design Considerations for Plasma Accelerators Driven by Lasers or Particle Beams

Plasma accelerators may be driven by the ponderomotive force of an intense laser or the space-charge force of a charged particle beam. The implications for accelerator design and the different physical mechanisms of laser-driven and beam-driven plasma acceleration are discussed. Driver propagation is examined, as well as the effects of the excited plasma wave phase velocity. The driver coupling to subsequent plasma accelerator stages for high-energy physics applications is addressed.

43 PARTICLE ACCELERATORS↗

Design progress for the 22 GeV CEBAF energy upgrade

In this work we examine the progress made in the design of the proposed FFA upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF). This proposed upgrade will double the number of passes through the two linacs by replacing the two highest energy arcs with new Fixed Field Alternating Gradient (FFA) arcs, roughly doubling the energy. These FFA arcs will use permanent magnets in a Halbach configuration to shape their fields. The design involves new optics for the linacs and remaining electromagnetic arcs, as well as new electromagnetic separators. These feed into the permanent magnet FFA arcs. We also report on ongoing studies of the dynamics of the beams, and an experiment to measure the effects of radiation on the permanent magnets.

Accelerator Physics↗