Search NASA⌕ Search

SEARCH · Search NASA

Results for “BETA DECAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Sterile neutrinos and the global reactor antineutrino dataset

We present results from global fits to the available reactor antineutrino dataset, as of Fall 2019, to determine the global preference for a fourth, sterile neutrino. We have separately considered experiments that measure the integrated inverse-beta decay (IBD) rate from those that measure the energy spectrum of IBD events at one or more locations. The evidence that we infer from rate measurements varies between ≲ 3σ and negligible depending on the reactor antineutrino flux model employed. Moreover, we find that spectral ratios ostensibly imply ≳ 3σ evidence, consistent with previous work, though these measurements are known to be plagued by issues related to statistical interpretation; these results should therefore be viewed cautiously. The software used is the newly developed GLoBESfit tool set which is based on the publicly available GLoBES framework and will be released as open-source software.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalies in global SMEFT analyses. A case study of first-row CKM unitarity

Recent developments in the Standard Model analysis of semileptonic charged-current processes involving light quarks have revealed ~ 3σ tensions in Cabibbo universality tests involving meson, neutron, and nuclear beta decays. In this paper, we explore beyond the Standard Model explanations of this so-called Cabibbo Angle Anomaly in the framework of the Standard Model Effective Field Theory (SMEFT), including not only low-energy charged current processes (‘L’), but also electroweak precision observables (‘EW’) and Drell-Yan collider processes (‘C’) that probe the same underlying physics across a broad range of energy scales. The resulting ‘CLEW’ framework not only allows one to test explanations of the Cabibbo Angle Anomaly, but is set up to provide near model-independent analyses with minimal assumptions on the flavor structure of the SMEFT operators. Besides the global analysis, we consider a large number of simpler scenarios, each with a subset of SMEFT operators, and investigate how much they improve upon the Standard Model fit. We find that the most favored scenarios, as judged by the Akaike Information Criterion, are those that involve right-handed charged currents. Additional interactions, namely oblique operators, terms modifying the Fermi constant, and operators involving right-handed neutral currents, play a role if the CDF determination of the W mass is included in the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Type II Seesaw leptogenesis

The Type II Seesaw Mechanism provides a minimal framework to explain the neutrino masses involving the introduction of a single triplet Higgs to the Standard Model. However, this simple extension was believed to be unable to successfully explain the observed baryon asymmetry of the universe through Leptogenesis. In our previous work (Phys. Rev. Lett. 128 (2022) 141801), we demonstrated that the triplet Higgs of the Type II Seesaw Mechanism alone can simultaneously generate the observed baryon asymmetry of the universe and the neutrino masses while playing a role in setting up Inflation. This is achievable with a triplet Higgs mass as low as 1 TeV, and predicts that the neutral component obtains a small vacuum expectation value $v_Δ$ < 10 keV. We find that our model has very rich phenomenology and can be tested by various terrestrial experiments as well as by astronomical observations. Particularly, we show that the successful parameter region may be probed at a future 100 TeV collider, upcoming lepton flavor violation experiments such as Mu3e, and neutrinoless double beta decay experiments. Additionally, the tensor-to-scalar ratio from the inflationary scenario will be probed by the LiteBIRD telescope, and observable isocurvature perturbations may be produced for some parameter choices. In this article, we present all the technical details of our calculations and further discussion of its phenomenological implications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scalar and tensor neutrino interactions

We constrain general Dirac neutrino interactions based on the Standard Model Effective Field Theory framework extended with right-handed neutrinos N (SMNEFT) using deep inelastic and coherent elastic neutrino scattering, nuclear beta decay, and meson decay data, and high energy electron-proton and proton-proton collider data. We compute the one-loop anomalous dimensions of the low-energy effective field theory (LEFT) below the electroweak scale and of SMNEFT above the electroweak scale. The tree-level matching between LEFT and SMNEFT is performed at the electroweak scale. Currently, the most stringent limits on scalar and tensor interactions arise from pseudoscalar meson decays and the LHC measurements at the per mille level. In the future, the upcoming High-Luminosity LHC (HL-LHC) has the potential to reach the 10 -4 level and LHeC can play an important role under certain theoretical assumptions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Leptonic anomalous magnetic moments in ν SMEFT

We investigate contributions to the anomalous magnetic moments of charged leptons in the neutrino-extended Standard Model Effective Field Theory (νSMEFT). We discuss how νSMEFT operators can contribute to a lepton’s magnetic moment at one- and two-loop order. We show that only one operator can account for existing electronic and muonic discrepancies, assuming new physics appears above 1 TeV. In particular, we find that a right-handed charged current in combination with minimal sterile-active mixing can explain the discrepancy for sterile neutrino masses of $\mathcal{O}$(100) GeV while avoiding direct and indirect constraints. We discuss how searches for sterile neutrino production at the (HL-)LHC, measurements of h → μ + μ - and searches for h → e + e - , neutrinoless double beta decay experiments, and improved unitarity tests of the CKM matrix can further probe the relevant parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sterile neutrino dark matter within the ν SMEFT

Sterile neutrinos with masses at the keV scale and mixing to the active neutrinos offer an elegant explanation of the observed dark matter (DM) density. However, the very same mixing inevitably leads to radiative photon emission and the non-observation of such peaked X-ray lines rules out this minimal sterile neutrino DM hypothesis. We show that in the context of the Standard Model effective field theory with sterile neutrinos (νSMEFT), higher dimensional operators can produce sterile neutrino DM in a broad range of parameter space. In particular, νSMEFT interactions can open the large mixing parameter space due to their destructive interference, through operator mixing or matching, in the X-ray emission. We also find that, even in the zero mixing limit, the DM density can always be explained by νSMEFT operators. The testability of the studied νSMEFT operators in searches for electric dipole moments, neutrinoless double beta decay, and pion decay measurements is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino properties from muonium-antimuonium mixing

The nature of neutrino mass — whether neutrinos are Dirac or Majorana particles — remains one of the central open questions in particle physics. While observation of neutrinoless double beta decay would confirm the Majorana case, the absence of a signal offers no definitive insight. In light of this, we investigate muonium-antimuonium mixing — proposed for further study at the MACE experiment — as an alternative probe of neutrino properties. We compute the mixing amplitude in the Standard Model minimally extended to include massive Dirac or Majorana neutrinos, and correct previous calculations by properly treating the relevant infrared scales. As the GIM mechanism strongly suppresses the Dirac contribution, we explore whether relaxing unitarity of the PMNS matrix can enhance the mixing without obscuring neutrino properties. Surprisingly, the answer to this question is negative. We also examine the pseudo-Dirac case — predominantly Dirac neutrinos with small Majorana masses — and find that this scenario can significantly enhance the mixing compared to the pure Dirac case, especially for normal mass ordering.

Neutrino interactions↗

Using DUNE to shed light on the electromagnetic properties of neutrinos

We study future DUNE sensitivity to various electromagnetic couplings of neutrinos, including magnetic moments, milli-charges, and charge radii. The DUNE PRISM capabilities play a crucial role in constraining the electron flavored couplings. We find that DUNE will be able to place the strongest beam based constraint on the muon-neutrino magnetic moment by improving on LSND’s bounds by roughly a factor of two, although Borexino’s constraint from solar neutrinos will be stronger. For the muon neutrino millicharge DUNE can place the leading beam based bound, with two orders of magnitude improvement compared to the existing COHERENT constraint, suggesting that DUNE can be useful for light mediators more generally. Despite this strength, the millicharge bounds are not competitive with strong bounds from stellar cooling, beta-decay, and matter stability. Finally, DUNE may be able to test the SM prediction for the muon neutrino charge radius, by placing a constraint two times better than CHARM-II and CCFR experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CUORE Detector and Results

The cryogenic underground observatory for rare events (CUORE) is a cryogenic experiment searching for neutrinoless double beta decay (0νββ) of 130 Te. The detector consists of an array of 988TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. We report the CUORE initial operations and optimization campaigns. We then present the CUORE results on 0νββ and 2νββ decay of 130 Te obtained from the analysis of the physics data acquired in 2017.

0vββ↗

Evaluation of cosmogenic production of 39 Ar and 42 Ar for rare-event physics using underground argon

Underground argon (UAr) with lower cosmogenic activities of 39 Ar and 42 Ar has been planned as a detector in detecting scintillation light and charge collection using time projection chambers for dark matter searches and as a veto detector in suppressing backgrounds for neutrinoless double beta decay (0$vββ$ ) experiments. Long-lived radioactive isotopes, 39 Ar and 42 Ar, can also be produced on the surface when UAr is pumped out from a deep well. Understanding the production of long-lived isotopes in Ar is important for utilizing UAr for dark matter and 0$vββ$ experiments in terms of its production, transportation, and storage. Ar exposure to cosmic rays at sea-level is simulated using Geant4 for a given cosmic ray muon, neutron, and proton energy spectrum. Here we report the simulated cosmogenic production rates of 39 Ar, 42 Ar, and other long-lived isotopes at sea-level from fast neutrons, high energy muons, and high energy protons. Total production rates of 938.53/kg Ar day and 5.81 × 10 -3 /kg Ar day for 39 Ar and 42 Ar are found from our simulation. Utilizing these production rates, we set a time limit of 954 days constrained by the production of 39 Ar for UAr to be on the surface before it compromises the sensitivity for a dark matter experiment. Similarly, a time limit of 1702 days constrained by the production of 42 Ar is found for a 0$vββ$ experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microstructural Effects of High Dose Helium Implantation in ErD 2

Metal hydrides can store hydrogen isotopes with high volumetric density. In metal tritides, tritium beta decay can result in accumulation of helium within the solid, in some cases exceeding 10 at.% helium after only 4 years of aging. Helium is insoluble in most materials, but often does not readily escape, and instead coalesces to form nanoscale bubbles when helium concentrations are near 1 at.%. Blistering or spallation often occurs at higher concentrations. Radioactive particles shed during this process present a potential safety hazard. This study investigates the effects of high helium concentrations on erbium deuteride (ErD 2 ), a non-radioactive surrogate material for erbium tritide (ErT 2 ). To simulate tritium decay in the surrogate, high doses of 120 keV helium ions were implanted into ErD 2 films at room temperature. Scanning and transmission electron microscopy indicated spherical helium bubble formation at a critical concentration of 1.5 at.% and bubble linkage leading to nanoscale crack formation at a concentration of 7.5 at.%. Additionally, crack propagation occurred through the nanocrack region, resulting in spallation extending from the implantation peak to the surface. Electron energy loss spectroscopy was utilized to confirm the presence of high-pressure helium in the nanocracks, suggesting that helium gas plays a predominant role in deformation. This work improves the overall understanding of helium behavior in ErD 2 by using modern characterization techniques to determine: the critical helium concentration required for bubble formation, the material failure mechanism at high concentration, and the nanoscale mechanisms responsible for material failure in helium implanted ErD 2 .

36 MATERIALS SCIENCE↗

A preliminary investigation into the electrodeposition and synthesis of radiopure Copper–Chromium alloys for rare-event physics detector systems

Current investigations into neutrinoless double beta decay and the direct detection of dark matter require increasingly sensitive detector systems that demand ultra-low background materials. These requirements have previously been attained using ultra-radiopure electroformed (EF) copper. However, pure copper possesses high ductility and relatively low strength, which necessitates the need for large amounts of material and extra care during fabrication to help minimize galling and mechanical failure. Furthermore, we investigate an alloying alternative to pure EF copper by examining low wt% copper chrome (Cu–Cr) solid solution alloys, with inquiries into alloy hardness, strength, and radiopurity. Alloyed Cu–Cr layered samples are shown to exhibit significantly increased hardness compared to EF copper, for example showing a 50% increase in exhibited hardness using less than 1% Cr by weight, with limited negative impact to the material’s radiopurity.

Background↗

The JSNS 2 detector

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV 2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this study, we describe the JSNS detector design, construction, and operation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber

The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. Here, we follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent charge barrier height of amorphous germanium contact detector

The exploration of germanium (Ge) detectors with amorphous Ge (a-Ge) contacts has drawn attention to the searches for rare-event physics such as dark matter and neutrinoless double-beta decay. The charge barrier height (CBH) of the a-Ge contacts deposited on the detector surface is crucial to suppress the leakage current of the detector in order to achieve a low-energy detection threshold and high-energy resolution. The temperature-dependent CBH of a-Ge contacts for three Ge detectors is analyzed to study the bulk leakage current (BLC) characteristics. The detectors were fabricated at the University of South Dakota using homegrown crystals. The CBH is determined from the BLC when the detectors are operated in the reverse bias mode with a guard-ring structure, which separates the BLC from the surface leakage current (SLC). Here the results show that CBH is temperature dependent. The direct relation of the CBH variation to temperature is related to the barrier inhomogeneities created on the interface of a-Ge and crystalline Ge. The inhomogeneities that occur at the interface were analyzed using the Gaussian distribution model for three detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible data acquisition system architecture for the Nab experiment

Here, the Nab experiment will measure the electron–neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model physics. Using National Instrument’s PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab’s specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at a rate of at least 1 MHz, while reading out a peak signal rate of approximately 2 GB/s. During the commissioning phase of the experiment, the system ran at a sustained readout rate of 400 MB/s of detector signal data originating from roughly 6 kHz L2 triggers, well within the peak performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗