Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bolometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Tracking antenna arrays for near-millimeter waves

A two-dimensional monolithic array has been developed that gives the elevation and azimuth of point source targets. The array is an arrangement of rows and columns of antennas and bismuth bolometer detectors on a fused quartz substrate. Energy is focused onto the array through a lens placed on the back side of the substrate. At 1.38 mm with a 50 mm diameter objective lens, the array has demonstrated a positioning accuracy of 26 arcmin. In a differential mode this precision improves to 9 arcsec, limited by the mechanics of the rotating stage. This tracking could be automated to a fast two-step procedure where a source is first located to the nearest row and column, and then precisely located by scanning. With signal processing the array should be able to track multiple sources.

Tong, P. P.↗

Sub-Kelvin temperatures in space

It is pointed out that the use of temperatures below 1 K in space would provide a significant improvement in several areas of research. The sensitivity of bolometers, for instance, can be improvead by as much as a factor of 50, if the operating temperature is lowered from 1.5 K to 0.3 K. A decrease in temperature to 0.1 K can provide even an improvement up to three orders of magnitude. Detectors based on the utilization of such improvements could be employed for far-infrared (100-1000 microns) photometry and spectroscopy in the low-background conditions of space. The study of critical phenomena in He-3/He-4 mixtures is also of interest, taking into account investigations at the tricritical point (0.87 K), which represents the junction of a first-order and a second-order transition. Tests in space are needed because gravity-related effects make adequate tests on earth impossible. He-3 refrigeration can be used to attain temperatures below 1 K. Adiabatic demagnetization can produuce temperatures below 0.3 K.

Kittel, P.↗

Air-bridge microbolometer for far-infrared detection

A new microbolometer for far-infrared detection has been fabricated that allows an increase in sensitivity of a factor of 4 over the best previously reported bolometer. By suspending the detector in the air above its substrate, a reduction in the thermal conductance out of the device by a factor of 5 has been achieved. At a modulation frequency of 100 kHz this microbolometer has an electrical noise equivalent power 28 pW/sq rt Hz. A thermal model is also presented that accurately fits the response of the detector.

Neikirk, D. P.↗

Far-infrared and submillimeter observations of the low-luminosity protostars L1455 FIR and L1551 IRS 5 - The confinement of bipolar outflows

Far-IR observations of L1455 FIR and L1551 IRS 5 obtained in December, 1981, and in September, 1982, and January, 1983, respectively, using the H-1 and G-2 bolometer systems on the 91-cm telescope of the NASA Kuiper Aiborne Observatory are reported. Additional observations at 400 microns were obtained with UKIRT in November, 1981, (L1551) and with NASA IRTF in November, 1982 (L1455). The results are presented in tables and graphs, and L1455 and L1551 are compared with other objects in terms of central-star parameters, clouds, and overflows. The characteristics calculated for L1455 and L1551 include luminosity 1.5 and 23 solar luminosity, size less than 7 x 10 to the 16th cm, H2 density greater than or equal to 4 x 10 to the 5th and 1 x 10 to the 6th/cu cm, and 35-K dust cores of 0.2 and 0.7 solar mass, respectively. The bipolar appearance of the L1551 outflow is attributed to circumstellar material only.

Davidson, J. A.↗

Tunable far-infrared spectroscopy

Tunable, CW, far-infrared radiation has been generated by nonlinear mixing of radiation from two CO2 lasers in a metal-insulator-metal (MIM) diode. The FIR difference-frequency power radiated from the MIM diode antenna to a calibrated indium antimonide bolometer. Two-tenths of a microwatt of FIR power was generated by 250 mW from each of the CO2 lasers. The combination of lines from a waveguide CO2 laser, with its larger tuning range, with lines from CO2, N2O, and CO2 isotopic lasers promises complete coverage of the entire far-infrared band from 100 to 5000 GHz (3-200 per cm) with stepwise-tunable CW radiation. To demonstrate the usefulness of the technique, the J = 4-5 line of CO was observed at 567 GHz.

Evenson, K. M.↗

Tunable Heterodyne Receiver from 100 Micron to 1,000 Micron for Airborne Observations

Interest in high resolution spectrometers for the submillimeter wavelength range from 100 micron to 1,000 micron is mostly stimulated by molecular spectroscopy in radioastronomy and atmospheric physics, and by plasma diagnostic experiments. Schottky diodes in waveguide mixer technology and InSb-hot electron bolometers are successfully used in the 0.5 to a few millimeter range whereas tandem Fabry-Perot spectrometers combined with photoconductive detectors (Ge:Sb and Ge:Ga) are used for the 100 micron range. Recent research on heterodyne spectrometers, with Schottky diodes in an open structure mixer and a molecular laser as local oscillators, which can be used over the whole wavelength range is summarized.

Roeser, H. P.↗

Submillimeter wave absorption of n-type InSb at low temperatures

The absorption coefficient of two high-purity n-InSb samples is measured in the 10-40 per cm range using Fourier transform spectroscopy. The absorption coefficient spectrum is presented for both samples at 4.2 K. It is also shown for the lower resistance sample cooled to 2.2 K and heated by dc bias to elevated electron gas temperatures of 7.5 and 17.9 K. ac Drude theory gives rather poor agreement with experiment at 2.2 and 4.2 K but does much better when the sample electron gas is heated. In contrast, a simple quantum mechanical theory of absorption based on inverse Bremsstrahlung yields promising agreement at the lower temperatures although its applicability is questionable. The non-Drudian absorption is shown to have a favorable effect on the performance of InSb hot-electron bolometers.

Brown, E. R.↗

Temperature of comet IRAS-Araki-Alcock (1983d)

Comet 1983d was named IRAS-Araki-Alcock in honor of its codiscoverers, including the Infrared Astronomical Satellite (IRAS) and two amateur astronomers. It is pointed out that the apparition of Comet 1983d was the closest cometary approach to earth since the development of modern astronomy. Because of the evolution of electromagnetic detector technology, a large range of ground-based observations of this object were possible. In the present investigation, attention is given to observations and some interpretations of the spectrum of Comet IRAS-Araki-Alcock in the wavelength region from 1.5 to 20 microns. In addition to the observations made with a bolometer and discrete filters, spectrophotometric observations were made of the nuclear condensation of Comet 1983d in the 1.5- to 2.6-micron wavelength region at 5 percent resolution.

Brown, R. H.↗

Technology for satellite power conversion

The dipole pattern of the antenna was confirmed and work on the MOM diode began. The antenna - detector structure was modified and the measurement apparatus reconfigured to permit precise antenna pattern measurements. Fabrication of the MOM diode was initiated after antenna action from the new structures was observed. A refined antenna structure was developed. The previous antenna design allowed currents induced by the incident radiation in the bonding wires to flow through the bolometer. The detector was thus responding to both the antenna and bonding wire currents. A low pass filter was added to the antenna structure to improve the detection scheme. The new design uses an interdigitated capacitor to prevent the induced current in the bonding wires from flowing through the detection element.

Gouker, M. A.↗

Space infrared telescope facility (SIRTF) focal plane

The Infrared Array Camera (IRAC), Multiband Imaging Photometer (MIP), and the Infrared Spectrometer (IRS) of the Space Infrared Telescope Facility (SIRTF) are described. The configuration and capabilities of the SIRTF are discussed. The small silicon array module, the germanium array module, and bolometer module of MIP, which is designed to provide sensitivity limited only by natural background and telescope emissions over the 3-200 micron spectral range, and allow diffraction limited imaging, super resolution techniques, mapping, and surveying, are examined. The objectives and design of the IRAC, which is constructed for two-dimensional photometry and imaging over a wavelength region from 2-30 microns and to perform extragalactic, galactic and solar system astronomy, are studied. The use of the IRS to study the dynamical and physical phenomena of the universe in the 2.5-200 micron range is analyzed.

Ramos, R.↗

Proceedings of the Second Infrared Detector Technology Workshop

The workshop focused on infrared detector, detector array, and cryogenic electronic technologies relevant to low-background space astronomy. Papers are organized into the following categories: discrete infrared detectors and readout electronics; advanced bolometers; intrinsic integrated infrared arrays; and extrinsic integrated infrared arrays. Status reports on the Space Infrared Telescope Facility (SIRTF) and Infrared Space Observatory (ISO) programs are also included.

Mccreight, C. R.↗

The infrared morphology of galactic centers

Initial results are presented of a program to map the centers of galaxies in the mid-infrared using the NASA-MSFC 20 pixel bolometer array. Maps at 10.8 micrometer of the galaxies NGC 5236 (M82), NGC 1808, NGC 4536, and NGC 4527 reveal complex emitting regions ranging in size from 500 pc to 2 kpc. The infrared spatial distributions generally resemble those in the visible and radio. In all cases a large fraction of the IRAS 12 micrometer flux originates in spatial structures prominent in the maps.

Telesco, C. M.↗

Thermal infrared imaging of Comet Halley

Thermal infrared images (10.8, 12.8, and 19.2 microns) of comet Halley were obtained on 1986 Mar. 28.7, 29.7 and 30.7 UT using the NASA-MSFC 20-pixel bolometer array at the NASA Infrared Telescope Facility. Analysis of the observations shows: the presence of spatial structure indicative of dust ejection occurring mainly on the sunward side of the nucleus; a dust coma deficient in large particles (radius greater than 100 microns) compared with that of Comet P/Giacobini-Zinner, temporal variability consistent with an extrapolation of a quasi-sinusoidal light curve observed by IUE on 1986 March 23, 24, and 25; and a maximum at the nuclear condensation of the color temperature and the strength of the silicate emission feature.

Campins, H.↗

MIPS - The Multiband Imaging Photometer for SIRTF

The Multiband Imaging Photometer for SIRTF (MIPS) is to be designed to reach as closely as possible the fundamental sensitivity and angular resolution limits for SIRTF over the 3 to 700 micron spectral region. It will use high performance photoconductive detectors from 3 to 200 micron with integrating JFET amplifiers. From 200 to 700 microns, the MIPS will use a bolometer cooled by an adiabatic demagnetization refrigerator. Over much of its operating range, the MIPS will make possible observations at and beyond the conventional Rayleigh diffraction limit of angular resolution.

Rieke, G. H.↗

MIPS - The Multiband Imaging Photometer for SIRTF

The Multiband Imaging Photometer System (MIPS) for SIRTF is to be designed to reach as closely as possible the fundamental sensitivity and angular resolution limits for SIRTF over the 3 to 700 microns spectral region. It will use high performance photoconductive detectors from 3 to 200 microns with integrating JFET amplifiers. From 200 to 700 microns, the MIPS will use a bolometer cooled by an adiabatic demagnetization refrigerator. Over much of its operating range, the MIPS will make possible observations at and beyond the conventional Rayleigh diffraction limit of angular resolution.

Rieke, G. H.↗

Noise tube sources for the far IR and millimeter region

The radiant output of a noise tube designed for the 90-140-GHz (3.3-2.1-mm) frequency range has been compared with that from mercury lamps over the wavelength region from 0.4 to about 6 mm. Lamellar grating and Michelson Fourier transform spectrometers were used in conjunction with He cooled bolometers of NEP from 10 to the -12th to 10 to the -14th W/sq rt H2 to measure relative spectral irradiance. With this instrumental arrangement, the radiant power emitted by the noise tube was observed to be less than that from a mercury lamp, at least to a 3-mm wavelength, but it produced less source noise than an ac operated mercury lamp. When the noise tube operating current was reduced, the spectral irradiance peak shifted to longer wavelengths.

Moller, K. D.↗

Infrared observations of eclipses of Io, its thermophysical parameters, and the thermal radiation of the Loki volcano and environs

Observations of Io during eclipses by Jupiter in 1981-1984 are reported. Data obtained at 3.45-30 microns using bolometer system No. 1 on the 3-m IRTF telescope at Mauna Kea are presented in extensive tables and graphs and analyzed by means of least-squares fitting of thermophysical models to the eclipse cooling and heating curves, thermal-radiation calculations for the Io volcanoes, and comparison with Voyager data. Best fits are obtained for a model comprising (1) a bright region with a vertically inhomogeneous surface and (2) a dark vertically homogeneous region with thermal inertia only about 0.1 times that of (1). Little evidence of volcanic-flux variability during the period is found, and the majority (but not all) of the excess thermal IR radiation in the sub-Jovian hemisphere is attributed to the Loki volcano and its lava lake.

Sinton, William M.↗

A spectral radiance comparison of a noise tube and a HgXe arc lamp between 60 GHz and 600 GHz

The relative spectral radiance of a noise tube, model TN-167, designed for the frequency range 90-140 GHz (3.3 mm to 2.1 mm) was compared to that from a 200-watt high pressure HgXe arc lamp over the wavelength region from 0.5 to about 5 mm. A Michelson Fourier transform spectrometer and a lamellar grating instrument were used in conjunction with liquid helium-cooled bolometers of NEP 10 to the -12th to 10 to the -14th watt/(Hz) exp 1/2 to measure relative spectral radiant power. With this instrumental arrangement, the noise tube exhibited a very sharp low frequency cutoff at about 2.2/cm. The HgXe arc lamp emitted more radiant power than the noise tube in the wavelength region below 3 mm (100 GHz) down to 0.5 mm. Above 3 mm, the noise tube had a stronger output. The noise tube spectral radiance shifted to lower frequencies when the input current was lowered from 125 mA to 50 mA.

Heaney, J. B.↗