Search NASA⌕ Search

SEARCH · Search NASA

Results for “Code surrogates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Assessing time-dependent temperature profile predictions using reduced transport models for high performing NSTX plasmas

Time-dependent, predictive simulations were performed with the 1.5D tokamak integrated modeling code TRANSP on a large set of well-analyzed, high performing discharges from the National Spherical Torus Experiment (NSTX) in order to evaluate how well modern reduced transport models can reproduce experimentally observed temperature profiles in spherical tokamaks. Overall, it is found that simulations using the Multi-Mode Model (MMM) more consistently agree with the NSTX observations than those using the Trapped Gyro-Landau Fluid (TGLF) model, despite TGLF requiring orders of magnitude greater computational cost. When considering all examined discharges, MMM has median overpredictions of electron temperature (T e ) and ion temperature (T i ) profiles of 28% and 27%, respectively, relative to the experiment. TGLF overpredicts T e by 46%, with much larger variance than MMM, and underpredicts T i by 25%. As the ratio of kinetic to magnetic field pressure (β) is increased across NSTX discharges, TGLF predicts lower T e and significant flattening of the T i profile, conflicting with NSTX observations. When using an electrostatic version of TGLF, both T e and T i are substantially overpredicted, underscoring the importance of electromagnetic turbulence in the high β spherical tokamak regime. Additionally, calculations with neural net surrogate models for TGLF were performed outside of TRANSP with a time slice flux matching transport solver, finding better agreement with experiment than the TRANSP simulations, highlighting the impact of different transport solvers and simulation techniques. Furthermore, the reasonable agreement with experiment of temperature profiles predicted by MMM motivates a more detailed examination of the sensitivities of the TRANSP simulations with MMM to different NSTX plasma regimes in a companion paper (Lestz et al Plasma Phys. Control. Fusion 67 105030), in preparation for self-consistent, time-dependent predictive modeling of NSTX-U scenarios.

Lestz, J. B. [General Atomics, San Diego, CA (Unit↗

Efficient Probabilistic Prediction and Uncertainty Quantification of Tropical Cyclone–Driven Storm Tides and Inundation

Abstract This study proposes and assesses a methodology to obtain high-quality probabilistic predictions and uncertainty information of near-landfall tropical cyclone–driven (TC-driven) storm tide and inundation with limited time and resources. Forecasts of TC track, intensity, and size are perturbed according to quasi-random Korobov sequences of historical forecast errors with assumed Gaussian and uniform statistical distributions. These perturbations are run in an ensemble of hydrodynamic storm tide model simulations. The resulting set of maximum water surface elevations are dimensionality reduced using Karhunen–Loève expansions and then used as a training set to develop a polynomial chaos (PC) surrogate model from which global sensitivities and probabilistic predictions can be extracted. The maximum water surface elevation is extrapolated over dry points incorporating energy head loss with distance to properly train the surrogate for predicting inundation. We find that the surrogate constructed with third-order PCs using elastic net penalized regression with leave-one-out cross validation provides the most robust fit across training and test sets. Probabilistic predictions of maximum water surface elevation and inundation area by the surrogate model at 48-h lead time for three past U.S. landfalling hurricanes (Irma in 2017, Florence in 2018, and Laura in 2020) are found to be reliable when compared to best track hindcast simulation results, even when trained with as few as 19 samples. The maximum water surface elevation is most sensitive to perpendicular track-offset errors for all three storms. Laura is also highly sensitive to storm size and has the least reliable prediction. Significance Statement The purpose of this study is to develop and evaluate a methodology that can be used to provide high-quality probabilistic predictions of hurricane-induced storm tide and inundation with limited time and resources. This is important for emergency management purposes during or after the landfall of hurricanes. Our results show that sampling forecast errors using quasi-random sequences combined with machine learning techniques that fit polynomial functions to the data are well suited to this task. The polynomial functions also have the benefit of producing exact sensitivity indices of storm tide and inundation to the forecasted hurricane properties such as path, intensity, and size, which can be used for uncertainty estimation. The code implementing the presented methodology is publicly available on GitHub.

54 ENVIRONMENTAL SCIENCES↗

Computational Bayesian Framework for Quantification and Reduction of Predictive Uncertainty in Subsurface Environmental Modeling

Subsurface environmental systems are open and complex, in which intricate hydrologic, microbiologic, and geochemical processes occur and interact at multiple scales. Understanding and predicting system responses to natural forces (e.g., climate changes) and human activities (e.g., contaminant remediation and CO 2 sequestration) is indispensable for managing water resources, cleaning subsurface contamination at many sites of the Department of Energy (DOE), and providing expert analysis to inform policy-making on long-term stewardship of nuclear waste disposal and CO 2 storage sites. Groundwater reactive transport modeling is necessary for understanding and predicting the complex subsurface environmental system. However, as complex systems are never completely predictable, model predictions of the subsurface system are inherently uncertain, and uncertainty is one of the greatest obstacles in simulating the subsurface environment. Quantifying predictive uncertainty of the complex system is critical to test model predictive power, support decision-making, and guide experimental design and data collection for uncertainty reduction. This project tackled two major obstacles to efficient and effective quantification and reduction of predictive uncertainty in simulating the complex subsurface environment. One obstacle is that existing methods of uncertainty quantification are too fragmented and incomplete for understanding and predicting the complex subsurface environment as a whole. The other obstacle is that existing methods of uncertainty quantification are computationally demanding and may not be applicable to groundwater reactive transport modeling that is always computationally expensive. The above two obstacles to uncertainty quantification directly affect the design of data collection schemes for uncertainty reduction. In this project, we developed a comprehensive Bayesian framework to remove the first obstacle. The second obstacle was tackled by using the sparse grid methods, which were originally developed and analyzed for numerical integration in the field of applied mathematics. We integrated the sparse grid methods into the Bayesian framework seamlessly, which led to a sparse-grid-based method of Bayesian uncertainty analysis. The developed computational Bayesian framework has been applied to a number of subsurface environmental problems through collaborating with scientists at the Pacific Northwest National Laboratory and Oak Ridge National Laboratory. The applications demonstrated that the computational Bayesian framework is general and compatible with any models and numerical codes of subsurface modeling. It is thus can be applied to gain insights for subsurface environmental modeling. This project helped the PI achieve his career goal to advance the state-of-the-art computational methods in uncertainty quantification for subsurface environmental modeling. This project supported two doctoral students, two master students, and one post-doc. The two doctoral students, after their graduation, worked as post-docs at the Pacific Northwest National Laboratory and the Oak Ridge National Laboratory. The project produced a total of 29 journal articles (four under review), one book chapter, and a number of conference proceedings and abstracts.

54 ENVIRONMENTAL SCIENCES↗

Feasibility of High-Power Diode Laser Array Surrogate to Support Development of Predictive Laser Lethality Model

Predictive modeling and simulation of high power laser-target interactions is sufficiently undeveloped that full-scale, field testing is required to assess lethality of military directed-energy (DE) systems. The cost and complexity of such testing programs severely limit the ability to vary and optimize parameters of the interaction. Thus development of advanced simulation tools, validated by experiments under well-controlled and diagnosed laboratory conditions that are able to provide detailed physics insight into the laser-target interaction and reduce requirements for full-scale testing will accelerate development of DE weapon systems. The ultimate goal is a comprehensive end-to-end simulation capability, from targeting and firing the laser system through laser-target interaction and dispersal of target debris; a 'Stockpile Science' - like capability for DE weapon systems. To support development of advanced modeling and simulation tools requires laboratory experiments to generate laser-target interaction data. Until now, to make relevant measurements required construction and operation of very high power and complex lasers, which are themselves costly and often unique devices, operating in dedicated facilities that don't permit experiments on targets containing energetic materials. High power diode laser arrays, pioneered by LLNL, provide a way to circumvent this limitation, as such arrays capable of delivering irradiances characteristic of De weapon requires are self-contained, compact, light weight and thus easily transportable to facilities, such as the High Explosives Applications Facility (HEAF) at Lawrence Livermore National Laboratory (LLNL) where testing with energetic materials can be performed. The purpose of this study was to establish the feasibility of using such arrays to support future development of advanced laser lethality and vulnerability simulation codes through providing data for materials characterization and laser-material interaction models and to validate the accuracy of code predictions. This project was a Feasibility Study under the LLNL Laboratory Directed Research and Development (LDRD) Program.

42 ENGINEERING↗

Modeling of the Molten Salt Reactor Experiment with SCALE

A SCALE model was developed for the Molten Salt Reactor Experiment (MSRE) benchmark that was recently added to the International Handbook of Evaluated Reactor Physics Benchmark Experiments. This SCALE model served as a basis for criticality calculations and nuclear data sensitivity and uncertainty analyses with the Monte Carlo code Shift and the TSUNAMI computational capabilities in the SCALE code system. The focus of this work is the assessment of the impact of nuclear data on the calculated eigenvalue results in support of the discussion of differences between the calculated and the experimental eigenvalue result. The differences in the eigenvalues obtained using the ENDF/B-VII.0, ENDF/B-VII.1, and ENDF/B-VIII.0 nuclear data libraries cover a relatively small range of ~230 pcm. Since eigenvalue sensitivity of the MSRE is dominated by the neutron multiplicity and neutron capture of 235 U and elastic scattering in graphite, relevant changes in the ENDF/B libraries for nuclear reactions (such as carbon capture) that caused large differences in other graphite-moderated systems did not have a significant impact. Propagation of nuclear data uncertainty results in an eigenvalue uncertainty of ~700 pcm with the major contributors being 235 U neutron multiplicity, graphite elastic scattering, and 7Li neutron capture. All calculations resulted in large differences of ~2000 pcm in eigenvalue compared to the benchmark experimental value. Several potential contributors to this difference—including uncertainties and gaps in the knowledge of the material, geometry, and nuclear data—were identified. Simplified models of the full MSRE core were developed, and similarity assessments were conduced with the full MSRE core model. It was found that simplified models can serve as adequate surrogates of the full-core model such that they can be used for performing selected nuclear data performance assessments with a lower computational burden.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer

To quantify the daily rotation of the prostate during a radiotherapy course using stereoscopic kilovoltage (kV) x-ray imaging and intraprostatic fiducials for localization and positioning correction. From 2005 to 2009, radio-opaque fiducial markers were inserted into 38 patients via perineum into the prostate. The ExacTrac/Novalis Body X-ray 6-day image acquisition system (ET/NB; BrainLab AG, Feldkirchen, Germany) was used to determine and correct the target position. During the first period in 10 patients we recorded all rotation errors but used only Y (table) for correction. For the next 28 patients we used for correction all rotational coordinates, i.e., in addition Z (superior-inferior [SI] or roll) and X (left-right [LR] or tilt/pitch) according to the fiducial marker position by use of the Robotic Tilt Module and Varian Exact Couch. Rotation correction was applied above a threshold of 1 Degree-Sign displacement. The systematic and random errors were specified. Overall, 993 software-assisted rotational corrections were performed. The interfraction rotation errors of the prostate as assessed from the radiodense surrogate markers around the three axes Y, Z, and X were on average 0.09, -0.52, and -0.01 Degree-Sign with standard deviations of 2.01, 2.30, and 3.95 Degree-Sign , respectively. The systematic uncertainty per patient for prostate rotation was estimated with 2.30, 1.56, and 4.13 Degree-Sign and the mean random components with 1.81, 2.02, and 3.09 Degree-Sign . The largest rotational errors occurred around the X-axis (pitch), but without preferring a certain orientation. Although the error around Z (roll) can be compensated on average by a transformation with 4 coordinates, a significant error around X remains and advocates the full correction with 6 coordinates. Rotational errors as assessed via daily stereoscopic online imaging are significant and dominate around X. Rotation possibly degrades the dosimetric coverage of the target volume and may require suitable strategies for correction.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-225: Histology Study of MR Guided Pulsed Focused Ultrasound On Treatment of Prostate Cancer in Vivo

Purpose: Our previous study demonstrated significant tumor growth delay in the mice treated with pulsed high intensity focused ultrasound (pHIFU). The purpose of this study is to understand the cell killing mechanisms of pHIFU. Methods: Prostate cancer cells (LNCaP), were grown orthotopically in 17 nude mice. Tumor-bearing mice were treated using pHIFU with an acoustic power of 25W, pulse width 100msec and 300 pulses in one sonication under MR guidance. Mutiple sonications were used to cover the whole tumor volume. The temperature (less than 40 degree centigrade in the focal spot) was monitored using MR thermometry. Animals were euthanized at pre-determined time points (n=2) after treatment: 0 hours; 6 hrs; 24 hrs; 48 hrs; 4 days and 7 days. Two tumorbearing mice were used as control. Three tumor-bearing mice were treated with radiation (RT, 2 Gy) using 6 MV photon beams. RT treated mice were euthanized at 0 hr, 6 hrs and 24 hrs. The tumors were processed for immunohistochemical (IHC) staining for PARP (a surrogate of apoptosis). A multispectral imaging analysis system was used to quantify the expression of PARP staining. Cell apoptosis was calculated based on the PARP expression level using the DAB analysis software. Results: Our data showed that PARP related apoptosis peaked at 48 hrs and 7 days in pHIFU treated mice, which is comparable to that for the RT group at 24 hrs. The preliminary results from this study were consistent with our previous study on tumor growth delay using pHIFU. Conclusion: Our results demonstrated that non-thermal pHIFU increased apoptotic tumor cell death through the PARP related pathway. MR guided pHIFU may have a great potential as a safe, noninvasive treatment modality for cancer therapy. This treatment modality may synergize with PARP inhibitors to achieve better therapeutic result.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-08: Dual Modality Verification for Respiratory Gating Using New Real- Time Tumor Tracking Radiotherapy System

Purpose: The respirato ry gating system combined the TrueBeam and a new real-time tumor-tracking radiotherapy system (RTRT) was installed. The RTRT system consists of two x-ray tubes and color image intensifiers. Using fluoroscopic images, the fiducial marker which was implanted near the tumor was tracked and was used as the internal surrogate for respiratory gating. The purposes of this study was to develop the verification technique of the respiratory gating with the new RTRT using cine electronic portal image device images (EPIDs) of TrueBeam and log files of the RTRT. Methods: A patient who underwent respiratory gated SBRT of the lung using the RTRT were enrolled in this study. For a patient, the log files of three-dimensional coordinate of fiducial marker used as an internal surrogate were acquired using the RTRT. Simultaneously, the cine EPIDs were acquired during respiratory gated radiotherapy. The data acquisition was performed for one field at five sessions during the course of SBRT. The residual motion errors were calculated using the log files (E{sub log}). The fiducial marker used as an internal surrogate into the cine EPIDs was automatically extracted by in-house software based on the template-matching algorithm. The differences between the the marker positions of cine EPIDs and digitally reconstructed radiograph were calculated (E{sub EPID}). Results: Marker detection on EPID using in-house software was influenced by low image contrast. For one field during the course of SBRT, the respiratory gating using the RTRT showed the mean ± S.D. of 95{sup th} percentile E{sub EPID} were 1.3 ± 0.3 mm,1.1 ± 0.5 mm,and those of E{sub log} were 1.5 ± 0.2 mm, 1.1 ± 0.2 mm in LR and SI directions, respectively. Conclusion: We have developed the verification method of respiratory gating combined TrueBeam and new real-time tumor-tracking radiotherapy system using EPIDs and log files.

60 APPLIED LIFE SCIENCES↗

Absolute Dosimetry Model of the University of Washington Clinical Neutron Therapy System (CNTS)

The University of Washington (UW) Clinical Neutron Therapy System (CNTS) generates a fast neutron beam using 50.5 MeV protons incident on a beryllium target. The CNTS is mainly used for fast neutron therapy in the treatment of cancer but is also used for radiation effects testing and the production of rare isotopes, or isotopes with a short half-life, for medical imaging and therapy. The accelerator and treatment head is modeled using the MCNP6 Monte Carlo code to enable beam characterization (neutron and photon fluence, linear energy transfer, secondary particle production), study the behavior of neutron dosimeters and ionization chamber (IC) responses, and to conduct first principle studies of the relative biological effectiveness (RBE) of fast neutrons compared to {sup 60}Co γ-rays. Measurements of neutron dose in selected CNTS fields were made using a model-17 ion chamber (IC-17) flowing methane-based, tissue-equivalent (TE) gas. As a first approximation, we compared IC-17 measurements to the MCNP calculated dose in a thin layer of water at selected locations along the central axis of the beam. To examine the impact of the composition of the chamber fill-gas and the chamber design characteristics, we also developed a high-resolution (∼ 50 μm) MCNP model of the IC-17 from a computerized tomography (CT) scan. Initial results indicate that the dose response of the IC-17 ion chamber is up to 30% larger (smaller?) compared to the dose to water for neutrons with energies >20 MeV. Differences in chamber and water response as large as 800% occur for neutrons with kinetic energies below 1 keV. The simulations of IC-17 response (and dose to water) for CNTS fast neutron spectra match measured doses within 4.6% for all field sizes and irradiation geometries considered. This reported studies provide additional evidence establishing use of the IC-17 ion chamber model or a thin layer of water as a reasonable surrogate for CNTS fast neutron dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

CFD unified approach under Eulerian–Lagrangian framework for methanol and gasoline direct injection sprays in evaporative and flash boiling conditions

Innovative synthetic fuels for advanced propulsion systems, such as methanol and ammonia, and synthetic blended fuels (E00, E10, and E30), known for their high volatility, are often injected directly into combustion chambers. It follows that Eulerian–Lagrangian spray models need to accurately capture the spray collapse as a consequence of flash boiling onset and be capable of proficiently handling the preferential evaporation of multi-component fuels in evaporative scenarios. So, we performed the assessment of an Eulerian–Lagrangian CFD code for simulating methanol and E00 gasoline blend sprays in both early and late injection conditions involving flash boiling conditions and preferential evaporation. The adoption of an effervescent breakup model and of a non-equilibrium phase transition model for the discrete phase allows the adoption of a setup that is almost completely free from specific constant tuning, especially for what concerns the breakup model. We validated the simulations using experimental PLV maps of methanol and E00 sprays issued from the ECN Spray M injector. The results highlight a significantly different morphology of the methanol spray compared to the E00 one under late injection conditions. Under stratified combustion, low-volatile fuels are likely to be ignited first, and the flame propagates toward the high-volatile fuels. In conclusion, the spray collapse was also correctly reproduced, inducing the presence of a low-pressure zone and modifying the spray morphology.

E00↗

Neural chaos: A spectral stochastic neural operator

Building surrogate models for operators with uncertainty quantification capabilities is essential for many engineering applications where randomness–such as variability in material properties, boundary conditions, and initial conditions–is unavoidable. Polynomial Chaos Expansion (PCE) is widely recognized as a go-to method for constructing stochastic surrogates in both intrusive and non-intrusive ways, and it has recently been used in the context of operator learning. However, its application becomes challenging for complex or high-dimensional processes, as achieving accuracy requires higher-order polynomials, which can increase computational demand and/or the risk of overfitting. Furthermore, PCE requires specialized treatments to manage random variables that are not independent, and these treatments may be problem-dependent or may fail with increasing complexity. Here, in this work, we adopt the same formalism as the spectral expansion used in PCE; however, we replace the classical polynomial basis functions with neural network (NN) basis functions to leverage their expressivity. To achieve this, we propose an algorithm that identifies NN-parameterized basis functions in a purely data-driven manner, without any prior assumptions about the joint distribution of the random variables involved, whether independent or dependent, or about their marginal distributions. The proposed algorithm identifies each NN-parameterized basis function sequentially, ensuring they are orthogonal with respect to the data distribution. The basis functions are constructed directly on the joint stochastic variables without requiring a tensor product structure or assuming independence of the random variables. This approach may offer greater flexibility for complex stochastic models, while simplifying implementation compared to the tensor product structures typically used in PCE to handle random vectors. This is particularly advantageous given the current state of open-source packages, where building and training neural networks can be done with just a few lines of code and extensive community support. We demonstrate the effectiveness of the proposed scheme through several numerical examples of varying complexity and provide comparisons with classical PCE.

Polynomial chaos expansion↗

Probing the antiknock effect of anisole through an ignition, speciation and modeling study of its blends with isooctane

In order to unravel the reaction pathways relevant to anisole co-oxidation within a fuel blend, a detailed study of isooctane/anisole blends was performed with the ULille RCM. Ignition delays as well as mole fraction profiles were measured during a two-stage ignition delay using sampling and GC techniques. These results are used to validate a kinetic model developed from ab initio calculations for the most relevant rate constants which included H-atom abstraction reactions from anisole, and reactions on the potential energy surfaces of methoxyphenyl + O 2 and anisyl + O 2 . Pressure dependent rate constants were computed for the methoxyphenyl + O 2 and anisyl + O 2 reactive systems using master equation code analysis. The new kinetic model shows good agreement with the experimental data. Dual brute-force sensitivity analysis was performed, on both first- and second-stages of ignition, allowing the identification of the most important reactions in the prediction of both ignition delays. It was observed that while pure anisole does not show NTC behavior, a 60/40 isooctane/anisole blend displays such behavior, as well as two-stage ignition. This suggests anisole addition may not be as beneficial to knock resistance as expected from its high octane number. The kinetic modeling results demonstrate the importance of H-abstraction reactions both from the methoxy group and from the aryl ring in ortho-position and the addition of the resultant radicals to O2, mostly leading to the formation of polar or non-aromatic products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluoride salt static freezing study

Molten salt reactor designs such as the FHR must consider the safety implications of freezing, requiring the development of thermal hydraulics models that account for freezing behavior. Pipe models that couple heat transfer, fluid dynamics, and phase change physics will require verification and validation. A static freezing study is being conducted to provide an initial set of validation data with LiF-BeF{sub 2} (FLiBe). The study will also be performed with LiF-NaF-KF (FLiNaK) in order to quantify the distortion that arises from using FLiNaK as a non-toxic surrogate salt for thermal-hydraulic studies. In order to develop the numerical model, accurate inputs for the thermal hydraulic properties of the two salts of interest need to be measured near the freezing point. For this reason, a series of three experiments including Differential Scanning Calorimetry (DSC) measurements, the Density Measurement Experiment, and the Static Freezing Experiment are being conducted to determine these thermo-physical properties at temperatures near the freezing point. The Static Freezing Experiment is also designed to determine the degree of supercooling that FLiBe and FLiNaK experience. Supercooling is a temperature depression below the freezing point that the liquid experiences before freezing initiates. Increased supercooling in a liquid flowing through a pipe leads to increased dendritic freezing and an increased likelihood of pipe blockage and freeze-shut. Based on previous research on supercooling in water and non-fluoride salts, supercooling is likely affected most strongly by cooling rate and sample size (as well as salt purity). No data has been generated previously on supercooling in fluoride salts such as FLiBe and FLiNaK. The results of this set of DSC, Density Measurement and Static Freezing experiments will be used in an ongoing fluoride salt freezing study being conducted to develop pipe freezing models for molten salts to be used in safety analysis. The thermal hydraulic properties measured in this study will serve as inputs for all future models. With the supercooling behavior of both salts quantified, it can be assessed whether supercooling must be included in future thermal hydraulic models. The validated Static Freezing Experiment model can then serve as the framework for a pipe freezing model and eventually a 1D system code.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Pushered single shell implosions for mix and radiation trapping studies using high-Z layers on National Ignition Facility

Pushered Single Shells (PSSs) are another approach to Inertial Confinement Fusion implosions that employ high-Z materials in the innermost capsule layer (pusher) as a means to enhance radiation trapping and lower core ignition requirements. However, adding high-Z materials can also increase losses due to mix, provide extra tamping, and make the capsule emission opaque to x-ray diagnostics. The first PSS implosions performed on the National Ignition Facility use plastic ablators with a germanium (Ge) dopant as a high-Z surrogate in the pusher to isolate the effects of high-Z mix and radiation trapping without changing tamping. Using a 2-shock laser pulse, the PSS implosions are designed and symmetrized to reach 3.7 keV core temperatures. A low concentration (2.8%) Ge dopant is added to the innermost layer, and the resulting effects on mix and x-ray opacity are observed. The method of separated reactants is used to infer information about mixing between the deuterated plastic pusher and the capsule fill gas (25% tritium) from the resulting nuclear DT reactions. Radiation transport is studied via capsule emission x-ray spectroscopy and imaging. Both nuclear and x-ray data corroborate the hypothesis that the addition of Ge strongly affects the mix region through radiation losses but has a minimal effect on the core and the warm, unmixed regions. Simulations using diffusive and turbulent mix models agree qualitatively with data, but quantitative agreement may require hybrid mix models that can model the transitional regime between turbulence and diffusion. Simulations matching the observables show increased core radiation trapping when Ge is added.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of quantitative structure-activity relationship (QSAR) models to predict the carcinogenic potency of chemicals

Determining the carcinogenicity and carcinogenic potency of new chemicals is both a labor-intensive and time-consuming process. In order to expedite the screening process, there is a need to identify alternative toxicity measures that may be used as surrogates for carcinogenic potency. Alternative toxicity measures for carcinogenic potency currently being used in the literature include lethal dose (dose that kills 50% of a study population [LD{sub 50}]), lowest-observed-adverse-effect-level (LOAEL) and maximum tolerated dose (MTD). The purpose of this study was to investigate the correlation between tumor dose (TD{sub 50}) and three alternative toxicity measures as an estimator of carcinogenic potency. A second aim of this study was to develop a Classification and Regression Tree (CART) between TD{sub 50} and estimated/experimental predictor variables to predict the carcinogenic potency of new chemicals. Rat TD{sub 50}s of 590 structurally diverse chemicals were obtained from the Cancer Potency Database, and the three alternative toxicity measures considered in this study were estimated using TOPKAT, a toxicity estimation software. Though poor correlations were obtained between carcinogenic potency and the three alternative toxicity (both experimental and TOPKAT) measures for the CPDB chemicals, a CART developed using experimental data with no missing values as predictor variables provided reasonable estimates of TD{sub 50} for nine chemicals that were part of an external validation set. However, if experimental values for the three alternative measures, mutagenicity and logP are not available in the literature, then either the CART developed using missing experimental values or estimated values may be used for making a prediction.

60 APPLIED LIFE SCIENCES↗

SU-E-T-350: Verification of Gating Performance of a New Elekta Gating Solution: Response Kit and Catalyst System

Purpose: In this work, we have tested the performance of new respiratory gating solutions for Elekta linacs. These solutions include the Response gating and the C-RAD Catalyst surface mapping system.Verification measurements have been performed for a series of clinical cases. We also examined the beam on latency of the system and its impact on delivery efficiency. Methods: To verify the benefits of tighter gating windows, a Quasar Respiratory Motion Platform was used. Its vertical-motion plate acted as a respiration surrogate and was tracked by the Catalyst system to generate gating signals. A MatriXX ion-chamber array was mounted on its longitudinal-moving platform. Clinical plans are delivered to a stationary and moving Matrix array at 100%, 50% and 30% gating windows and gamma scores were calculated comparing moving delivery results to the stationary result. It is important to note that as one moves to tighter gating windows, the delivery efficiency will be impacted by the linac's beam-on latency. Using a specialized software package, we generated beam-on signals of lengths of 1000ms, 600ms, 450ms, 400ms, 350ms and 300ms. As the gating windows get tighter, one can expect to reach a point where the dose rate will fall to nearly zero, indicating that the gating window is close to beam-on latency. A clinically useful gating window needs to be significantly longer than the latency for the linac. Results: As expected, the use of tighter gating windows improved delivery accuracy. However, a lower limit of the gating window, largely defined by linac beam-on latency, exists at around 300ms. Conclusion: The Response gating kit, combined with the C-RAD Catalyst, provides an effective solution for respiratorygated treatment delivery. Careful patient selection, gating window design, even visual/audio coaching may be necessary to ensure both delivery quality and efficiency. This research project is funded by Elekta.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. The new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗