Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Micron MT29F128G08AJAAA 128GB Asynchronous Flash Memory Total Ionizing Dose Characterization Test Report

The purpose of this test was to characterize the Micron MT29F128G08AJAAAs parameter degradation for total dose response and to evaluate and compare lot date codes for sensitivity. In the test, the device was exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits and overall chip and die health were investigated to determine which lot is more robust.

Flash Memory↗

Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter

Purpose: To compare dosimetric characteristics of 6 MV photon fields originating from a linear accelerator operating with (FF) and without (FFF) a flattening-filter. The main objective is to establish a FFF model that results in similar depth-dose and build-up profiles as the original FF model, and subsequently estimate and compare out-of-field dose distributions. Methods: The EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc are used for photon beam simulations of an Elekta linear accelerator and dose calculations in a water phantom, respectively. Three beam models were analyzed: (1) the conventional linear accelerator with the flattening-filter in place and incident electron energy 6.45 MeV (FF 6.45 MeV), (2) similar flattening-filter-free model (FFF 6.45 MeV), and (3) as (2) but with increased electron energy (FFF 8.0 MeV). The field size 5 Multiplication-Sign 5 cm{sup 2} was used for characterization of dose output, depth dose profiles, and photon spectrum. The field size 40 Multiplication-Sign 40 cm{sup 2} was used for characterization of cross-field photon energy, photon fluence, and dose distributions. Out-of-field dose distributions were analyzed in both in-plane and cross-plane directions for 5 Multiplication-Sign 5 cm{sup 2} and 10 Multiplication-Sign 10 cm{sup 2} fields. Results: Comparable depth dose distributions, including the build-up region, for FF and FFF fields were achieved by increasing the electron energy from 6.45 MeV to 8.0 MeV for the FFF beam. The FFF beams result in reduced out-of-field dose compared to the FF beam: the reduction was most apparent in the cross-plane direction and more pronounced by the FFF 8.0 MeV beam compared to the FFF 6.45 MeV beam. Differences in out-of-field dose due to direction (in-plane vs cross-plane) were up to 40% for the FF beam; this effect was significantly reduced for the FFF beams. As the flattening-filter is a major source of contaminating electrons, superficial out-of-field dose was expected, and was found to be, reduced for FFF beams. Conclusions: The build-up and depth-dose characteristics of a conventional '6 MV' beam can be maintained when changing to a flattening-filter-free modality by increasing the incident electron energy from 6.45 MeV to 8.0 MeV. This will at the same time reduce the out-of-field dose for regions up to 20 cm from the central axis by 10%-30% compared to the original FF situation.

07 ISOTOPE AND RADIATION SOURCES↗

Measurements of the secondary particle energy spectra in the Space Shuttle

Measurements of the energy spectra of secondary particles produced by galactic cosmic rays and trapped protons due to the nuclear interactions of these particles with the Shuttle shielding provide a powerful tool for validating radiation transport codes. A code validated in this way can be used to better estimate the dose and dose equivalent to body organs, measurements that cannot be made directly. The principal cause of single event upsets in electronic devices in the region of the South Atlantic Anomaly is secondary particles, and even in the region of galactic cosmic radiation a significant fraction is produced by secondary particles. In this paper, we describe the first direct measurements of the energy spectra of secondary protons, deuterons, tritons, 3He and 4He produced by galactic cosmic rays inside the Space Shuttle using a charged particle spectrometer. A comparison of these spectra with radiation transport code HZETRN showed reasonably good agreement for secondary protons. However, the code seriously underestimated the flux of all other light ions. The code has been modified to include pick-up and knock-on processes. The modified code leads to good agreement for deuterons and 3He but not for other light ions. This revised code leads to about 10% higher dose equivalent than the original code under moderate shielding, if we assume that higher charge ion fluxes are correctly predicted by the model.

short duration↗

SU-E-T-673: Recent Developments and Comprehensive Validations of a GPU-Based Proton Monte Carlo Simulation Package, GPMC

Purpose: A GPU-based Monte Carlo (MC) simulation package gPMC has been previously developed and high computational efficiency was achieved. This abstract reports our recent improvements on this package in terms of accuracy, functionality, and code portability. Methods: In the latest version of gPMC, nuclear interaction cross section database was updated to include data from TOPAS/Geant4. Inelastic interaction model, particularly the proton scattering angle distribution, was updated to improve overall simulation accuracy. Calculation of dose averaged LET (LETd) was implemented. gPMC was ported onto an OpenCL environment to enable portability across different computing devices (GPUs from different vendors and CPUs). We also performed comprehensive tests of the code accuracy. Dose from electro-magnetic (EM) interaction channel, primary and secondary proton doses and fluences were scored and compared with those computed by TOPAS. Results: In a homogeneous water phantom with 100 and 200 MeV beams, mean dose differences in EM channel computed by gPMC and by TOPAS were 0.28% and 0.65% of the corresponding maximum dose, respectively. With the Geant4 nuclear interaction cross section data, mean difference of primary proton dose was 0.84% for the 200 MeV case and 0.78% for the 100 MeV case. After updating inelastic interaction model, maximum difference of secondary proton fluence and dose were 0.08% and 0.5% for the 200 MeV beam, and 0.04% and 0.2% for the 100 MeV beam. In a test case with a 150MeV proton beam, the mean difference between LETd computed by gPMC and TOPAS was 0.96% within the proton range. With the OpenCL implementation, gPMC is executable on AMD and Nvidia GPUs, as well as on Intel CPU in single or multiple threads. Results on different platforms agreed within statistical uncertainty. Conclusion: Several improvements have been implemented in the latest version of gPMC, which enhanced its accuracy, functionality, and code portability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific Monte Carlo-Based Dose-Kernel Approach for Inverse Planning in Afterloading Brachytherapy

Purpose: Brachytherapy planning software relies on the Task Group report 43 dosimetry formalism. This formalism, based on a water approximation, neglects various heterogeneous materials present during treatment. Various studies have suggested that these heterogeneities should be taken into account to improve the treatment quality. The present study sought to demonstrate the feasibility of incorporating Monte Carlo (MC) dosimetry within an inverse planning algorithm to improve the dose conformity and increase the treatment quality. Methods and Materials: The method was based on precalculated dose kernels in full patient geometries, representing the dose distribution of a brachytherapy source at a single dwell position using MC simulations and the Geant4 toolkit. These dose kernels are used by the inverse planning by simulated annealing tool to produce a fast MC-based plan. A test was performed for an interstitial brachytherapy breast treatment using two different high-dose-rate brachytherapy sources: the microSelectron iridium-192 source and the electronic brachytherapy source Axxent operating at 50 kVp. Results: A research version of the inverse planning by simulated annealing algorithm was combined with MC to provide a method to fully account for the heterogeneities in dose optimization, using the MC method. The effect of the water approximation was found to depend on photon energy, with greater dose attenuation for the lower energies of the Axxent source compared with iridium-192. For the latter, an underdosage of 5.1% for the dose received by 90% of the clinical target volume was found. Conclusion: A new method to optimize afterloading brachytherapy plans that uses MC dosimetric information was developed. Including computed tomography-based information in MC dosimetry in the inverse planning process was shown to take into account the full range of scatter and heterogeneity conditions. This led to significant dose differences compared with the Task Group report 43 approach for the Axxent source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes

Purpose: GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of the total DPKs for the most commonly used radionuclides in nuclear medicine. Methods: Patient-specific absorbed dose calculations can be carried out using Monte Carlo simulations. The latest version of GATE extends its applications to Radiotherapy and Dosimetry. Comparison of the proposed method for the generation of DPKs was performed for (a) monoenergetic electron sources, with energies ranging from 10 keV to 10 MeV, (b) beta emitting isotopes, e.g., {sup 177}Lu, {sup 90}Y, and {sup 32}P, and (c) gamma emitting isotopes, e.g., {sup 111}In, {sup 131}I, {sup 125}I, and {sup 99m}Tc. Point isotropic sources were simulated at the center of a sphere phantom, and the absorbed dose was stored in concentric spherical shells around the source. Evaluation was performed with already published studies for different Monte Carlo codes namely MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE. A complete dataset of total DPKs was generated for water (equivalent to soft tissue), bone, and lung. This dataset takes into account all the major components of radiation interactions for the selected isotopes, including the absorbed dose from emitted electrons, photons, and all secondary particles generated from the electromagnetic interactions. Results: GATE comparison provided reliable results in all cases (monoenergetic electrons, beta emitting isotopes, and photon emitting isotopes). The observed differences between GATE and other codes are less than 10% and comparable to the discrepancies observed among other packages. The produced DPKs are in very good agreement with the already published data, which allowed us to produce a unique DPKs dataset using GATE. The dataset contains the total DPKs for {sup 67}Ga, {sup 68}Ga, {sup 90}Y, {sup 99m}Tc, {sup 111}In, {sup 123}I, {sup 124}I, {sup 125}I, {sup 131}I, {sup 153}Sm, {sup 177}Lu {sup 186}Re, and {sup 188}Re generated in water, bone, and lung. Conclusions: In this study, the authors have checked GATE's reliability for absorbed dose calculation when transporting different kind of particles, which indicates its robustness for dosimetry applications. A novel dataset of DPKs is provided, which can be applied in patient-specific dosimetry using analytical point kernel convolution algorithms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Model calculations of the radiation dose and LET spectra on LDEF and comparisons with flight data

Ionizing radiation environment models, a 3-D spacecraft mass model, and radiation transport codes have been used to predict the radiation dose and linear energy transfer (LET) spectra measured at various locations on the LDEF satellite. The predictions are compared with thermoluminescent dosimeter measurements of the trapped proton and electron doses and with LET spectra measured by plastic nuclear track detectors. The predicted vs observed comparisons indicate some of the uncertainties of present ionizing radiation environment models for low Earth-orbit missions.

LDEF Project↗

SU-E-T-424: Dosimetric Verification of Modulated Electron Radiation Therapy Delivered Using An Electron Specific Multileaf Collimator for Treatment of Scalp Cases

Purpose: Modulated electron radiotherapy (MERT) has the potential to achieve better treatment outcome for shallow tumors such as those of breast and scalp. In a separate study with scalp lesions, MERT was compared to volumetric modulated arc therapy. Our results showed a reduction in the dose reaching the brain with MERT. However dose calculation accuracy and delivery efficiency challenges remain. Thus in the current study we proceed to add more cases to demonstrate MERT beneficial outcome and its delivery accuracy using an electron specific multileaf collimator (eMLC). Methods: We have used the MCBEAM code for treatment head simulation and for generating phase space files to be used as radiation source input for our Monte Carlo based treatment planning system (MC TPS). MCPLAN code is used for calculation of patient specific dose deposition coefficient and for final MERT plan dose calculation. An in-house developed optimization code is used for the optimization process. MERT plans were generated for real patients and head and neck phantom. Film was used for dosimetric verification. The film was cut following the contour of the curved phantom surface and then sealed with black masking tape. In the measurement, the sealed film packet was sandwiched between two adjacent slabs of the head and neck phantom. The measured 2D dose distribution was then compared with calculations. Results: The eMLC allows effective treatment of scalps with multi-lesions spreading around the patient head, which was usually difficult to plan or very time consuming with conventional applicators. MERT continues to show better reduction in the brain dose. The dosimetric measurements showed slight discrepancy, which was attributed to the film setup. Conclusion: MERT can improve treatment plan quality for patients with scalp cancers. Our in-house MC TPS is capable of performing treatment planning and accurate dose calculation for MERT using the eMLC.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulation analysis for radiation damage on Glidcop Al-15 caused by 17-20 MeV/u heavy ions

The Facility for Rare Isotope Beams (FRIB) SRF linear heavy-ion accelerator is designed to accelerate all ions up to uranium to a maximum beam power of 400 kW. Several beam intercepting devices (BIDs) are essential to the successful operation of the accelerator, including a low power charge selector (LPCS) made of copper containing 0.15% precipitated aluminum oxide by weight called Glidcop Al-15. As FRIB ramps up the primary beam power beyond the current 20 kW level, the charge selector must withstand higher radiation damage rates, typically measured in displacements per atom (dpa). Significant beam induced radiation damage including significant deformation, like swelling, blistering, and cracking has been observed on a recently removed LPCS. We also observed physical features up to about 5.5 mm wide and appear to be deeper than the projected range of any ions. This paper presents the results of Monte Carlo simulations carried out using the Particle and Heavy Ion Transport code System (PHITS), quantifying the total damage dose and ion concentration, etc. Simulating an accurate irradiation history is essential to determining the scope of post irradiation examination (PIE) work.

Fletcher, Ethan [Michigan State U.]↗

SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

TU-D-209-03: Alignment of the Patient Graphic Model Using Fluoroscopic Images for Skin Dose Mapping

Purpose: The Dose Tracking System (DTS) was developed to provide realtime feedback of skin dose and dose rate during interventional fluoroscopic procedures. A color map on a 3D graphic of the patient represents the cumulative dose distribution on the skin. Automated image correlation algorithms are described which use the fluoroscopic procedure images to align and scale the patient graphic for more accurate dose mapping. Methods: Currently, the DTS employs manual patient graphic selection and alignment. To improve the accuracy of dose mapping and automate the software, various methods are explored to extract information about the beam location and patient morphology from the procedure images. To match patient anatomy with a reference projection image, preprocessing is first used, including edge enhancement, edge detection, and contour detection. Template matching algorithms from OpenCV are then employed to find the location of the beam. Once a match is found, the reference graphic is scaled and rotated to fit the patient, using image registration correlation functions in Matlab. The algorithm runs correlation functions for all points and maps all correlation confidences to a surface map. The highest point of correlation is used for alignment and scaling. The transformation data is saved for later model scaling. Results: Anatomic recognition is used to find matching features between model and image and image registration correlation provides for alignment and scaling at any rotation angle with less than onesecond runtime, and at noise levels in excess of 150% of those found in normal procedures. Conclusion: The algorithm provides the necessary scaling and alignment tools to improve the accuracy of dose distribution mapping on the patient graphic with the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Radiation Dose Modeling for Niowave’s Accelerator Driven Uranium Target Assembly 3

Molybdenum-99 is a high-value radionuclide commonly used for medical purposes within the United States. The National Nuclear Security Administration (NNSA) seeks to reliably produce the radioisotope 99 Mo without the use of highly enriched uranium. NNSA’s Office of Material Management and Minimization (M3) provides funding and government laboratory expertise to private companies to expedite the production process domestically and currently funds designs that use low-enriched uranium or other 99 Mo production pathways. Several production designs are being explored across the industry, including uranium fission and photonuclear conversion of 100 Mo targets. Niowave Inc. seeks to produce 99 Mo via a high-energy electron accelerator that strikes a lead-bismuth eutectic target that ultimately produces a consistent neutron flux. The neutron flux then interacts in a subcritical reactor core configuration to produce fission in low-enriched or natural uranium targets. These fissionable targets are then processed to extract 99 Mo. The purpose of this work is to estimate the neutron and photon dose response across Niowave’s proposed facility for worker safety during operation. Owing to the size of the proposed Niowave facility and necessary shielding, unbiased Monte Carlo radiation transport is impractical, and variance reduction methods are required. This work focuses on the weight window variance reduction method to produce high confidence dose response results within a Monte Carlo radiation transport code. Specifically, an adjoint-informed weight window methodology was created to improve the dose response estimates for accelerator-driven subcritical reactor designs. This adjoint-informed methodology was implemented for Niowave’s proposed design and improved dose results at far-field locations across the facility. Acceptable dose rate contours for the proposed facility were generated across the facility and are presented in this work.

07 ISOTOPE AND RADIATION SOURCES↗

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

SU-G-TeP3-13: The Role of Nanoscale Energy Deposition in the Development of Gold Nanoparticle-Enhanced Radiotherapy

Purpose: Gold nanoparticles (GNPs) can enhance radiotherapy effects. The high photoelectric cross section of gold relative to tissue, particularly at lower energies, leads to localized dose enhancement. However in a clinical context, photon energies must also be sufficient to reach a target volume at a given depth. These properties must be balanced to optimize such a therapy. Given that nanoscale energy deposition patterns around GNPs play a role in determining biological outcomes, in this work we seek to establish their role in this optimization process. Methods: The PENELOPE Monte Carlo code was used to generate spherical dose deposition kernels in 1000 nm diameter spheres around 50 nm diameter GNPs in response to monoenergetic photons incident on the GNP. Induced “lesions” were estimated by either a local effect model (LEM) or a mean dose model (MDM). The ratio of these estimates was examined for a range of photon energies (10 keV to 2 MeV), for three sets of linear-quadratic parameters. Results: The models produce distinct differences in expected lesion values, the lower the alpha-beta ratio, the greater the difference. The ratio of expected lesion values remained constant within 5% for energies of 40 keV and above across all parameter sets and rose to a difference of 35% for lower energies only for the lowest alpha-beta ratio. Conclusion: Consistent with other work, these calculations suggest nanoscale energy deposition patterns matter in predicting biological response to GNP-enhanced radiotherapy. However the ratio of expected lesions between the different models is largely independent of energy, indicating that GNP-enhanced radiotherapy scenarios can be optimized in photon energy without consideration of the nanoscale patterns. Special attention may be warranted for energies of 20 keV or below and low alpha-beta ratios.

60 APPLIED LIFE SCIENCES↗

Comparison of residual dose rates from MARS and DORIAN simulations with experimental data from the SINBAD database

This benchmarking study aims to compare residual dose rate predictions from the MARS and DORIAN codes with experimental measurements taken from samples irradiated at CERN's CERF facility. The research evaluates the residual dose rates of these samples over varied cooling intervals. Additionally, it delves into the influence of parameter choices, such as specific physics processes and energy thresholds, on the production and transport of particles and their effects on simulation outcomes. While both MARS and DORIAN largely align with experimental findings, discrepancies were observed in the copper sample. This prompted an in-depth examination of the elevated dose rates from MARS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing uncertainty in personnel dosimetry calculations in the VHTR plant using MAVRIC

This work analyzes the efficacy of the MAVRIC sequence of the Scale 6.1 code package with respect to the accuracy of results and the ability to utilize large-memory, parallel machines. MAVRIC implements the hybrid FW-CADIS methodology to solve neutron and photon transport for shielding applications. Using the discrete ordinates method to solve the Boltzmann transport equation, an importance map is generated which MAVRIC then uses to bias a stochastic Monte Carlo simulation. The MAVRIC sequence is applied to generate neutron and photon dose rate distributions of improved accuracy in a model of a proposed VHTR power plant. Problems like this one, with a size on the order of magnitude of a nuclear power plant, require a prohibitive amount of memory to store complete importance maps. The issue is addressed by refining the mesh in areas around the source through the detector regions, while leaving a coarse mesh elsewhere. Additionally through the use of parallel computing, the angular flux can be expanded in higher quadrature sets, which leads to a better importance map while requiring no extra memory requirements during the Monte Carlo portion of the sequence. The final Monte Carlo simulations can be run concurrently on several machines with results combined after the fact, emulating parallelism that is not yet available in MAVRIC sequence. Using a combination of strategies, the MAVRIC sequence is shown to be able to scale across available computational resources, allowing the user to more quickly obtain Monte Carlo results with lower relative uncertainties in large, deep-penetration shielding problems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-122: Dosimetric Comparison Between Cone, HDMLC and MicroMLC for the Treatment of Trigeminal Neuralgia

Purpose: The purpose of this work was to evaluate the dosimetric characteristics of three collimation systems, 5mm circular cone (Brainlab) and square fields of 5mm with HDMLC (Varian) and microMLC Moduleaf, Siemens) for trigeminal neuralgia treatment. Methods: A TPS Iplan v4.5 BrainLAB was used to do treatment plans for each collimations system in a square solid water phantom with isocenter at 5cm depth. Single field and treatment plan including 11 arcs with fix field and 100° gantry range was made for each collimation systems. EBT3 films were positioned at isocenter in a coronal plane to measured dose distribution for all geometries. Films were digitized with a Vidar DosimetryPro Red scanner with a resolution of 89dpi and RIT113v6.1 software was used for analysis. Penumbra region (80%–20%), FWHM and dose percentage at 5mm and 10mm from CAX were determined. All profiles were normalized at CAX. Results: For single beam the penumbra (FWHM) was 1.5mm (5.3mm) for the cone, 1.9mm (5.5mm) for HDMLC and 1.8mm (5.4mm) for the microMLC. Dose percentage at 5mm was 6.9% for cone, 12.5% for HDMLC and 8.7% for the microMLC. For treatment plan the penumbra (FWHM) was 2.58mm (5.47mm) for the cone, 2.8mm (5.84mm) for HDMLC and 2.58mm (6.09mm) for the microMLC. Dose perecentage at 5mm was 13.1% for cone, 16.1% for HDMLC, 15.2% for the microMLC. Conclusion: The cone has a dose falloff larger than the microMLC and HDMLC, by its reduced penumbra, this translates into better protection of surrounding healthy tissue, however, the microMLC and HDMLC have similar accuracy to cone.

60 APPLIED LIFE SCIENCES↗

SU-E-T-102: Determination of Dose Distributions and Water-Equivalence of MAGIC-F Polymer Gel for 60Co and 192Ir Brachytherapy Sources

Purpose: Analyse the water-equivalence of MAGIC-f polymer gel for {sup 60}Co and {sup 192}Ir clinical brachytherapy sources, through dose distributions simulated with PENELOPE Monte Carlo code. Methods: The real geometry of {sup 60} (BEBIG, modelo Co0.A86) and {sup 192}192Ir (Varian, model GammaMed Plus) clinical brachytherapy sources were modelled on PENELOPE Monte Carlo simulation code. The most probable emission lines of photons were used for both sources: 17 emission lines for {sup 192}Ir and 12 lines for {sup 60}. The dose distributions were obtained in a cubic water or gel homogeneous phantom (30 × 30 × 30 cm{sup 3}), with the source positioned in the middle of the phantom. In all cases the number of simulation showers remained constant at 10{sup 9} particles. A specific material for gel was constructed in PENELOPE using weight fraction components of MAGIC-f: wH = 0,1062, wC = 0,0751, wN = 0,0139, wO = 0,8021, wS = 2,58×10{sup −6} e wCu = 5,08 × 10{sup −6}. The voxel size in the dose distributions was 0.6 mm. Dose distribution maps on the longitudinal and radial direction through the centre of the source were used to analyse the water-equivalence of MAGIC-f. Results: For the {sup 60} source, the maximum diferences in relative doses obtained in the gel and water were 0,65% and 1,90%, for radial and longitudinal direction, respectively. For {sup 192}Ir, the maximum difereces in relative doses were 0,30% and 1,05%, for radial and longitudinal direction, respectively. The materials equivalence can also be verified through the effective atomic number and density of each material: Zef-MAGIC-f = 7,07 e .MAGIC-f = 1,060 g/cm{sup 3} and Zef-water = 7,22. Conclusion: The results showed that MAGIC-f is water equivalent, consequently being suitable to simulate soft tissue, for Cobalt and Iridium energies. Hence, gel can be used as a dosimeter in clinical applications. Further investigation to its use in a clinical protocol is needed.

60 APPLIED LIFE SCIENCES↗