ISS External Microorganisms: A Payload to Close Planetary Protection Knowledge Gaps for Crewed Missions

Before NASA or COSPAR is able to set planetary protection requirements for crewed missions to locations like Mars there are a number of critical knowledge gaps that must be addressed (1). One of the most important knowledge gaps is an understanding of microbial leakage from crewed habitats and space suits. Current ECLSS (Environmental Control and Life Support System) and PLSS (Portable Life Support System) requirements do not include any provisions to control microbes that may escape along with vented or leaked gasses. The current generation of NASA space suits can leak at rates as high as 100 cm2 /min. during nominal operation (2). ISS (International Space Station) intentionally vents atmospheric gases like CO2 to maintain habitable conditions for the crew. Furthermore, every time an airlock is used for EVA (extravehicular activity)there is an accompanying release of internal atmosphere. Since it is not possible to sterilize a crewed mission, it is important that we understand what if any microbes are entrained in these vented and leaked products. It is also important to understand if these microbes can survive on exterior surfaces. Recent sampling of the Russian segments of ISS suggest that bacteria and fungi from inside ISS may be capable of surviving on external surfaces(3). NASA is developing an aseptic sampling tool for use during EVA and plans to collect samples from vents on ISS to build on these results. The results of this work will be used to develop planetary protection requirements for vented and leaked gasses from crewed volumes. NASA has developed and tested a tool kit for collecting microbiological samples during EVA(4). This tool kit contains eight commercially available, 23 mm. diameter, foam swabs that can be used to aseptically collect samples while at vacuum. The swabs are individually housed in aluminum canisters that are equipped with 0.2 μm Teflon filters. These filters allow the canisters to equilibrate to pressure changes while preventing microbiological contamination. The canisters will be cleaned and sterilized before flight. Results from ground-based testing indicate that this tool kit is capable of aseptically collecting microbes while at vacuum without becoming contaminated during pressure changes(5). Based on the results of this ground testing we have modified the tool kit to meet NASA safety requirements and improve the ergonomics. We added additional mounting points to the tool kit to give astronauts more options for securing it during use. We also changed the opening mechanism to improve the precision with which swabs can be extracted from the tool kit. We plan to use this kit on an upcoming EVA to collect samples from non-propulsive vents and areas near the U.S. airlock on ISS. These samples will be frozen at -80 ̊C and stored on station until they can be returned to Earth. We will analyze these returned samples using next generation DNA sequencing to determine the community composition and function of external ISS environments. The results of this study will close planetary protection knowledge gaps for crewed missions and will help NASA determine appropriate planetary protection requirements for life support systems. The tool kit will also be useful for collecting aseptic samples on upcoming crewed or robotic missions and could easily be modified to collect samples with organic contamination control requirements as well.

A B Regberg↗

Developing and Testing a Common Space Systems Ontology using the Ontological Modeling Language

This paper describes the development and testing of the initial version of a common space systems ontology (CoSSO) for use by the Advanced Concepts Office (ACO) at NASA's Marshall Space Flight Center. The ontology provides a shared conceptualization of concepts of interest to the ACO for modeling aerospace systems concepts in a pre-phase A context to aid with the transition to a more model-based paradigm. The ontological concepts and relations, as well as the anticipated use cases, were developed through interactions with the relevant subject matter experts at the ACO and implemented in the Ontological Modeling Language (OML). The ontology builds on the Basic Formal Ontology (BFO) and the Common Core Ontologies (CCO). While most of the ontology is still in the initial stages, an Environmental Control and Life Support System (ECLSS) ontology is being built on top of the main CoSSO and heavily developed as a proof of concept. The ECLSS ontology is designed with different use cases in mind, namely predicting and diagnosing errors in ECLS systems on long-duration missions, with a focus on the Four-Bed CO$_2$ carbon dioxide scrubber currently on board the ISS. The ECLSS ontology is being developed in a similar manner to the CoSSO, and designed to be compatible with it. The current state of both ontologies is presented and discussed, along with plans for future development and testing.

Conceptual Design↗

To Biocide or not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

ISS External Microorganisms: A Planetary Protection Payload Ready-for-Flight

Before NASA or COSPAR is able to set planetary protection requirements for crewed missions to locations like Mars there are a number of critical knowledge gaps that must be addressed (1). One of the most important knowledge gaps is an understanding of microbial leakage from crewed habitats and space suits. Current ECLSS (Environmental Control and Life Support System) and PLSS (Portable Life Support System) requirements do not include any provisions to control microbes that may escape along with vented or leaked gasses. The current generation of NASA space suits can leak at rates as high as 100 cm3/min. during nominal operation (2). ISS (International Space Station) intentionally vents atmospheric gases like CO2to maintain habitable conditions for the crew. Furthermore, every time an airlock is used for EVA (extravehicular activity) there is an accompanying release of internal atmosphere. Since it is not possible to sterilize a crewed mission, it is important that we understand what if any microbes are entrained in these vented and leaked products. It is also important to understand if these microbes can survive on exterior surfaces. Recent sampling of the Russian segments of ISS suggest that bacteria and fungi from inside ISS may be capable of surviving on external surfaces (3). NASA has developed an aseptic sampling tool for use during EVA and plans to collect samples from vents on ISS to build on these results. The results of this work will be used to develop planetary protection requirements for vented and leaked gasses from crewed volumes.

M S Bell↗

Benefits of Trash-to-Gas Versus Jettison of Waste Via Trash-Lock for Mars Transit

Human exploration missions to Mars pose difficulties due to the significant waste that will be generated during transit, which will need to be carried along or disposed of in some fashion. Waste removal from the spacecraft decreases the spacecraft’s mass as well as the associated logistic items necessary for storing the waste. A mission propellant analysis was performed to highlight the mass benefits that may be accessed via waste removal. The propellant mass savings were determined for different waste removal rates (2.9 – 11.6 kg/day) with the highest removal rate leading to the greatest propellant savings of 7,785 kg for an 850-day round-trip mission. Due to these benefits, two methods for waste reduction were studied for the 850-day Mars mission: Trash-to-Gas (TtG) and physical jettison via a trash-lock. The trash-to-gas methods considered were combustion, steam reforming, and pyrolysis, which convert waste into ventable gases (e.g., CO2, CO, CH4, etc.). Combustion and steam reforming require a co-reactant (O2 and/or H2O). Therefore, additional processing units or integration with the spacecraft’s environmental control and life support system (ECLSS) are required to facilitate recycle of the pertinent species. In contrast, pyrolysis is a purely thermal degradation process, which can operate as a standalone system; however, a lower percentage of waste is gasified with pyrolysis. The study herein compares standalone TtG (e.g., Advanced Organic Waste Gasifier, Plasma Pyrolysis, etc.), integrated TtG-ECLSS (e.g., Orbital Syngas Commodity Augmentation Reactor, Incineration/Gasification, etc.), and physical jettison. Each system’s mass, volume, power, and cooling requirements were compared via an equivalent system mass (ESM) analysis to ascertain potentially promising technologies that can achieve efficient waste removal while minimizing their own spacecraft load. This study highlights the advantages and disadvantages of the different waste management technologies and provides recommendations on the promising technologies based on the ESM metric and propellant mass savings.

Jettison↗

To Biocide or not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

Analysis of CDC Bioreactor Internal Thermal Measurements and Sample Coupon Temperatures

The CDC Biofilm Reactor is an integral laboratory tool for the Environmental Control and Life Support Systems (ECLSS) biofilm formation and growth research program. Critical to this research is the need to adjust and maintain various surface temperatures of the coupons housed within the CDC Biofilm Reactor. The purpose of this study was to provide quantitative temperature gradient information when the CDC Biofilm Reactor was operating according to several process scenarios. Two primary process parameters were evaluated. For the first set of test parameters, the liquid level was maintained at 350 mL, with an inlet flowrate of 0.1 mL/min, 1 mL/min, 10 mL/min. The liquid was allowed to gravity drain out of the outlet spout. For the second set of test parameters, the liquid level within the reactor was maintained at 550 mL, with an inlet flow of 0.1 mL/min, 1 mL/min, 10 mL/min and draining intermittently controlled to 0.8 mL/min to maintain the 550 mL level. Due to the placement of the thermocouple in the reactor, a difference in temperature occurred between the coupon surfaces and target biofilm reactor temperature when operated according to the first set of test parameters. When the reactor was operated according to the second set of parameters, which resulted in the thermocouple being submerged, the temperature gradient was eliminated. The results demonstrated minimal temperature gradient between the top and bottom coupon surfaces for coupons placed in a single rod within the CDC Biofilm Reactor for both sets of test parameters evaluated. The collection of this information helped to explain previous ECLSS biofilm formation test runs, along with providing guidance on best operating practices for future ECLSS experiments. The placement of the thermocouple also helps to explain the challenge of achieving and maintaining bulk liquid temperatures when biofilm is grown according to the standardized test methods.

CDC Bioreactor↗

Development of an Efficient Alternative to Recovery O2 From Metabolic CO2 Via Electrolysis Operated at Ambient Temperature and Driven By A Highly Selective Catalysis

The current State of Art (SOA) on oxygen recovery onboard the Environmental Control and Life Support System (ECLSS) at the International Space Station (ISS) is complex, heavy, and power consuming system that recovers approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ). For future long duration beyond low earth orbit missions (LEO), O 2 recovery systems will need to be highly reliable, efficient, and recover a minimum of 75% O 2 from metabolic CO 2 . An alternative technology development effort currently underway at NASA Marshall Space Flight Center (MSFC) has the potential to significantly increase O 2 recovery currently limited to 50% (Sabatier) and reduce the complexity of ECLSS O 2 recovery. MSFC and University of Texas in Arlington (UTA) have jointly designed and fabricated a microfluid electrochemical reactor (MFECR) that operates at ambient conditions and utilizes a proprietary catalysis highly selective on reducing CO 2 to ethylene (C 2 H 4 ) at the cathode while O 2 is generated at the anode. The MFECR would replace three pieces of hardware for future ECLSS architectures: the current CO 2 Reduction Assembly (CRA) (Sabatier reactor), the Plasma Pyrolysis Assembly (PPA), and the Oxygen Generation Assembly (OGA). It is designed to interface directly with the CO 2 Removal Assembly (CDRA) and the Water Processing Assembly (WPA) to supply CO 2 reactant and water replenish respectively. This is expected to substantially improve sustainability of the ISS ECLSS and reduce requirement on power and weight. Here, we discuss the current development and evaluation efforts on different alternatives on not only the configuration and setup of the MFECR at an Engineering Design Unit (EDU) scale but also the selection of component materials.

Jesus A Dominguez↗

Thermal Modeling of a Novel Air-Cooled Temperature Swing Adsorption Compressor (AC-TSAC)

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO 2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO 2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. The current investigation addresses the thermal modeling of potential AC-TSAC designs. An initial thermal model was created and validated by comparing the model outputs to experimental data for the heating phase. Several design trades were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), and configuration of heat spreading elements within the bed. Also investigated is AC-TSAC performance sensitivity to the thermal conductivity of the adsorbent material and the heat pipes as well as the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.

Hannah S. Alpert↗

Alternative Treatment of Crew Wastewater Using a Hybrid Membrane Technology

Environmental Control and Life Support Systems (ECLSS) of future long-duration, deep-space human exploration missions should treat all “waste” streams for recovery and ideally by near closed-loop. Onboard the International Space Station (ISS), the Water Recovery System (WRS) does not treat urine and gray water to recover elements beyond water and utilizes physical-chemical technologies that operate with single-use and hazardous consumables. Urine offers a renewable source of nitrogen and other trace elements that can support sustainable crop production. In response to the lack of flight ready technologies capable of treating urine and gray water for water and nutrient recovery, a Suspended Aerobic Membrane Bioreactor (SAMBR) is under development between the University of South Florida and Kennedy Space Center. SAMBR is optimized for an early planetary base/partial gravity habitat and serves as a hybrid alternative to currently utilized urine treatment technologies and support closing the resource recovery loop. With its ECLSS minded form factor and modular design, SAMBR’s operation can be customized to suit the treatment objectives (i.e., nitrogen conversion) at that time. This proceeding presents preliminary research pertaining to: 1) design challenges in maximizing hydraulic throughput while minimizing mass and volume of the assembly; 2) capabilities for treating high nitrogen waste under steady and non-steady state conditions; and 3) measured performance parameters such chemical oxygen demand (COD), nitrogen conversion, nutrients, turbidity, and system throughput. Future research and development pertaining to further optimization on system safety, reliability, and expanded treatment capabilities will also be presented.

Membrane Filtration↗

To Biocide or Not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

Analysis of CDC Bioreactor Internal Thermal Measurements and Sample Coupon Temperatures

The Center for Disease Control and Prevention (CDC) bioreactor is an integral laboratory tool for the Environmental Control and Life Support Systems (ECLSS) biofilm formation and growth research program. Critical to this research is the need to adjust and maintain various surface temperatures of the coupons housed within the CDC Bioreactor. The purpose of this study was to provide quantitative temperature gradient information when the CDC Bioreactor was operating according to several process scenarios. Two primary process parameters were evaluated. For the first set of test parameters, the liquid level was maintained at 350 mL, with an inlet flowrate of 0.1 mL/min, 1 mL/min, 10 mL/min. The liquid was allowed to gravity drain out of the outlet spout. For the second set of test parameters, the liquid level within the reactor was maintained at 550 mL, with an inlet flow of 0.1 mL/min, 1 mL/min, 10 mL/min and draining intermittently controlled to 0.8 mL/min to maintain the 550 mL level. Due to the placement of the thermocouple in the reactor, a difference in temperature occurred between the coupon surfaces and target Bioreactor temperature when operated according to the first set of test parameters. When the reactor was operated according to the second set of parameters, which resulted in the thermocouple being submerged, the temperature gradient was eliminated. The results demonstrated minimal temperature gradient between the top and bottom coupon surfaces for coupons placed in a single rod within the CDC Bioreactor for both sets of test parameters evaluated. The collection of this information helped to explain previous ECLSS biofilm formation test runs, along with providing guidance on best operating practices for future ECLSS experiments. The placement of the thermocouple also helps to explain the challenge of achieving and maintaining bulk liquid temperatures when biofilm is grown according to the standardized test methods.

CDC Bioreactor↗

Bosch Process Technology Development for Air Revitalization

Closed-loop Environmental Control and Life Support Systems (ECLSS) aim to fully recover resources needed to keep astronauts alive in space– primarily, this means reclaiming oxygen (O2) to breathe and water (H2O) to drink from metabolic products. In air revitalization, this requires reclaiming the oxygen tied up in metabolic carbon dioxide (CO2). The current state of the art for the International Space Station (ISS) uses a Sabatier reaction in a system that has demonstrated a 50% O2 recovery rate. While there are several ongoing projects to improve the recovery of the Sabatier-based process, there are also projects working on an alternative approach centered around the Bosch process. Unlike the Sabatier, which has theoretical limits on maximum O2 recovery, the Bosch process can theoretically recover all of the O2 trapped in metabolic CO2 with only solid carbon (C) as a byproduct. However, the C generated in the process poses a significant challenge, introducing issues with clogging, contamination, and catalyst degradation that ultimately make the Bosch process unfeasible for flight at the current state of development. This poster overviews the promise and challenges of the Bosch process, prior investigations conducted, and current work towards advancing the TRL of Bosch-based O2 recovery systems and dealing with the (C) buildup. It also discusses potential uses of the carbon itself, which could prove to be a useful product in in-situ resource utilization (ISRU) applications.

Lunar↗

Mitigating Microbial Contamination Risks in CO 2 Removal Systems for Long-Duration Space Missions

Crewed missions to Mars and beyond pose new challenges for the crew and the technological solutions they depend upon. Crucial considerations in designing the next generation of Environmental Control and Life Support Systems (ECLSS) include enhanced reliability and autonomy, given the challenges of resupply and resource recovery in remote missions. One significant challenge faced in various sectors of the International Space Station and ECLSS is the phenomena of microbial growth, particularly biofilm formation. As such, microbial growth is a critical consideration in the design phase of new ECLSS systems. Two novel CO2 removal systems—Liquid-Amines CO2 Removal (LACR) and Cold-Surface CO2 Deposition (CDep)—are currently under development at the NASA Ames Research Center to meet the needs of extended space travel. In this presentation, the authors aim to make a risk assessment of microbial growth in LACR and CDep through: 1) a comprehensive literature review to identify LACR and CDep components most vulnerable to microbial contamination and 2) wet lab testing commencing with a subscale test of the most susceptible component of CDep. The literature review revealed that the hollow-fiber Liqui-Cel membrane employed in CDep exhibits the highest susceptibility to microbial growth. Our wet lab tests corroborated these findings, as airborne microbes introduced into the membrane led to considerable biomass accumulation. These results indicate a significant risk of microbial invasion into the membranes. To prevent microbial growth in CDep or other CO2 removal systems, proper ECLSS arrangement is essential—a CO2 removal system should remain behind the charcoal-HEPA filters, condensing heat exchanger, and Trace Contaminant Control System. In summary, anticipating potential microbial interactions within ECLSS for remote crewed missions is vital to mission success. It should, therefore, be included as one of the many factors when designing future ECLSS systems to perform reliably and consistently to support astronaut life.

A. Nicolas Whitlock↗

To Biocide or Not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide↗

The Influence of Smoke Particle Properties and Cabin Characteristics on Smoke Detection in Lunar Gravity

Spacecraft fires pose a threat to the success of future Lunar, Martian, and deep space exploration missions. As NASA plans to return humans to the Moon in the next decade, novel mission requirements will present new fire safety challenges. For example, materials that are fire resistant on Earth are expected to burn under planned habitat conditions (elevated oxygen concentrations and reduced cabin pressure) and partial gravity (0.16g). Optimal smoke detector placement will depend on a combination of buoyant plume velocities, induced by partial gravity, and Environmental Control and Life Support Systems (ECLSS) parameters, including particle filtration rates, supply and return placement within the cabin, and forced air velocities. These ECLSS parameters must also address the need for rapid Lunar dust removal, as Lunar dust exposure poses a risk to crew health and hardware functionality. Here, we present progress toward a computational fluid dynamics model to evaluate smoke transport in a Lunar habitat. Recent work has demonstrated that if air supplies are placed on ceilings and returns on the floor, a buoyant smoke layer at the ceiling may disperse over the order of minutes even under low forced flow conditions. We expand upon these results to examine the influence of different supply and return configurations on smoke plume development. Additionally, we also address differences in the transport of smoke particles and Lunar dust by varying particle parameters like size, density, and shape factor. Finally, we discuss ongoing and future experimental efforts to measure smoke particle properties and transport under partial gravity, elevated oxygen, and reduced pressure conditions.

Claire Fortenberry↗

Thermal Modeling of a Compressor for CO2 Removal in the International Space Station

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. A thermal model of the AC-TSAC was created in COMSOL and validated by comparing the model outputs to experimental data for the heating phase of the cycle. Subsequently, several design trades and performance sensitivities were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), thermal conductivity of the adsorbent material and bed structural materials, and the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.

Hannah Alpert↗