Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Target normal sheath acceleration with a large laser focal diameter

In this work, the dependence of the laser-driven ion acceleration from thin titanium foils in the Target Normal Sheath Acceleration (TNSA) regime on target and laser parameters is explored using two dimensional particle-in-cell simulations. The oblique incidence (θ L = 45°) and large focal spot size (w 0 = 40μm) are chosen to take an advantage of quasi one-dimensional geometry of sheath fields and effective electron heating. This interaction setup also reveals low and achromatic angular divergence of a proton beam. It is shown that the hot electron temperature deviates from the ponderomotive scaling for short laser pulses and small pre-plasmas. This deviation is mainly due to the laser sweeping, as the short duration laser pulse each moment in time effectively heats only a fraction of a focal spot on the foil. This instantaneous partial heating results in an electron temperature deviation from the ponderomotive scaling and, thus, lower maximum proton energies than it could have been expected from the TNSA theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

Sodium tracer measurements of an expanded dense aluminum plasma from e-beam isochoric heating

Spatially and temporally resolved visible absorption spectroscopy is performed on sodium D-lines present as surface contaminants on an expanded dense aluminum plasma plume. An 80-ns FWHM, intense, relativistic electron beam deposits 5.4 J into a 100- μ m-thick Al foil, which isochorically heats and subsequently hydrodynamically expands the material through the warm dense matter state and into a classical-like plasma state, with a coupling parameter of approximately 0.2 and a degeneracy parameter of approximately 270. The Na contamination, carried along with the expanding plume, shows saturated absorption features in the dense Al continuum for λ > 450 nm. X-ray photoelectron spectroscopy and laser-induced breakdown spectroscopy confirm Na is a surface contaminant with an atomic concentration of ~ 0.1 % when interrogating identical foil samples. Additioanlly, a spectroscopic-quality radiation transport model is used to post-process 2D hydrodynamic simulations to interpret the plasma conditions based on the measured Na 3p-3s doublet line profiles. A sodium number density of 3 × 10 15 cm -3 best matches the experimental spectra, which originate from a dense surface plasma with n e = 3.0 ± 0.8 × 10 18 cm -3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Talbot-Lau x-ray deflectometer: Refraction-based HEDP imaging diagnostic

Talbot-Lau x-ray interferometry has been implemented to map electron density gradients in High Energy Density Physics (HEDP) experiments. X-ray backlighter targets have been evaluated for Talbot-Lau X-ray Deflectometry (TXD). Cu foils, wires, and sphere targets have been irradiated by 10–150 J, 8–30 ps laser pulses, while two pulsed-power generators (∼350 kA, 350 ns and ∼200 kA, 150 ns) have driven Cu wire, hybrid, and laser-cut x-pinches. A plasma ablation front generated by the Omega EP laser was imaged for the first time through TXD for densities >1023 cm−3. Backlighter optimization in combination with x-ray CCD, image plates, and x-ray film has been assessed in terms of spatial resolution and interferometer contrast for accurate plasma characterization through TXD in pulsed-power and high-intensity laser environments. The results obtained thus far demonstrate the potential of TXD as a powerful diagnostic for HEDP.

Valdivia, M. P.↗

High resolution >40 keV x-ray radiography using an edge-on micro-flag backlighter at NIF-ARC

Radiography of low-contrast features in high-density materials evolving on a nanosecond timescale requires a bright photon source in the tens of keV range with high temporal and spatial resolution. One application for sources in this category is the study of dynamic material strength in samples compressed to Mbar pressures at the National Ignition Facility, high-resolution measurements of plastic deformation under conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Here, we present radiographic data and the modulation transfer function (MTF) analysis of a multi-component test object probed at ~100 keV effective backlighter energy using a 5 μm-thin dysprosium foil driven by the NIF Advanced Radiographic Capability (ARC) short-pulse laser (~2 kJ, 10 ps). The thin edge of the foil acts as a bright line-projection source of hard x rays, which images the test object at 13.2× magnification into a filtered and shielded image plate detector stack. The system demonstrates a superior contrast of shallow (5 μm amplitude) sinusoidal ripples on gold samples up to 90 μm thick as well as enhanced spatial and temporal resolution using only a small fraction of the laser energy compared to an existing long-pulse-driven backlighter used routinely at the NIF for dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Current polarity effects on laboratory plasma jets

Plasma jets produced by a pulsed power machine were investigated using Thomson scattering and other diagnostics in order to make detailed comparisons to simulations. These jets were produced from a 15 μm thick disc of Al foil on a 1.2 MA, 100 ns rise time, pulsed power machine. Experiments were performed with both a radially inward and a radially outward current ow in the Al foil to investigate the effects of voltage polarity in the experiments and determine how extended magnetohydrodynamic (XMHD) effects, such as the Hall effect, change the formation of the jet. We recorded Thomson scattering spectra with a low enough laser energy to not perturb the plasma, while providing a high enough signal to noise ratio to resolve the scattered features. This enabled the measurement of the electron temperature in the jet region of the plasma, 15.5±4 eV for both current polarities. Jets with a radially outward current ow were heated more from inverse bremsstrahlung when 10 J of laser energy was used, implying that these jets are denser than the ones with a radially inward current. This higher density was con rmed by interferometry measurements. Experimental results were compared with XMHD computer simulations, which predicted electron temperatures 1.5 to 3 σ above those measured, and significantly higher density than experiments in both polarities. In this paper, possible sources of this discrepancy are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density evolution after shock release from laser-driven polystyrene (CH) targets in inertial confinement fusion

The evolution of the plasma density in the rarefaction wave formed after a laser-driven shock is released from a CH foil was measured using optical interferometry. Here, it was found that the plasma density profile is very sensitive to the conditions at the back surface of the foil before the shock release. Dedicated experiments demonstrated that radiation preheat by coronal x-rays caused early expansion of the back surface and faster expansion of the rarefaction wave. Radiation-hydrodynamics simulations with accurate modeling of radiation preheat from the plasma corona are in good agreement with the experimental results. The early expansion of material interfaces due to coronal x-ray preheat must be evaluated in designing and interpreting laser-driven inertial confinement fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray source characterization and sample heating on x-ray diffraction experiments at the National Ignition Facility

X-ray diffraction is a powerful measurement technique for determining material properties, and it is now possible to perform these experiments at pressures exceeding 1 TPa [Rygg et al., Rev. Sci. Instrum. 91, 043902 (2020)] at the National Ignition Facility (NIF). The x-ray source for these experiments is the quasi-monochromatic Heα emission from metal foils heated to multi-keV temperatures. A critical aspect for understanding the sample's thermodynamic state is the amount of heating caused by absorption of the probe x-rays. In this work, we characterize the performance of the Ge foil x-ray source over more than 60 NIF x-ray diffraction experiments. We use this information to constrain the level of diffraction sample heating from the x-ray source and discuss the impact on the thermodynamic state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Silicon x-ray backlighter improvement by targets with spike-like microstructures

In order to accurately probe high energy density matter states, it is vital to create powerful x-ray backlighters. One approach to create such x-ray sources is based on the usage of short-pulse, high-energy lasers, which greatly benefits from an optimization of the laser target coupling. Here, the spectral and temporal x-ray emission profiles of structured silicon targets with micron-sized spikes on the front surface are studied at laser intensities of 10 17 W cm -2 . The laser pulse length is varied between 1 and 20 ps with an energy of up to 1 kJ. The structured targets show an up to 13× enhancement of silicon He α emission compared to flat foils with a well-defined, sharp emission pulse profile. Furthermore, the performance of the microstructured targets is compared to targets with a CH shield as well as foils irradiated with a UV prepulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient laser-driven proton acceleration from a petawatt contrast-enhanced second harmonic mixed-glass laser system

Efficient laser-driven plasma acceleration of ion beams requires precision control of the target–plasma profile, which is crucial to optimize the laser energy transfer. Along the laser propagation direction, this can be achieved by tailoring the temporal structure of the laser pulse. We show for the first time that frequency-doubling of a short pulse (hundreds-femtosecond range) petawatt-class mixed-glass laser system, which results in temporal intensity contrast enhancement, enables surface and volumetric laser–energy coupling, and the acceleration of proton beams from few-nanometer-thick foil targets. Experimentally, maximum ion energies and laser-to-proton energy conversion efficiencies were found to be both maximized at optimum laser and target conditions manifested when the normalized target density nearly equalizes the normalized laser vector potential, which is in agreement with theory and simulations. These signatures are recognized as a unique indication of the interaction between ultra-intense laser pulses with high temporal intensity contrast and ultra-thin nanometer-scale targets. Transverse modulations of accelerated proton beams in the form of bubble- and ring-like structures measured in the thinnest targets provide additional evidence of volumetric laser-driven particle acceleration regimes and transitional features in ultra-thin foil targets specific to laser–plasma interactions characterized by a high temporal intensity contrast. These results open avenues in the generation of high contrast laser pulses from short-pulse-femtosecond petawatt mixed-glass laser systems and demonstrate the feasibility of this technique for applications requiring high laser intensity contrast with high efficiency.

Physics↗

Characterization of laser-accelerated proton beams from a 0.5 kJ sub-picosecond laser for radiography applications

Laser-accelerated ion beams show promise for many applications, including high-resolution flash imaging of static or dynamic objects in next-generation radiography to probe materials and plasmas in extreme environments and inertial confinement fusion. To scale up ion beam production for radiography applications, we conducted experiments using sub-picosecond lasers up to 0.5 kJ at the OMEGA-EP facility to characterize proton beams from solid targets, primarily CH/CD sub-micron thin films from which ion beams were also used for static and dynamic radiography for the first time. For standalone sub-micron thin CH films, the highest detected proton energy is in the range of 72–97 MeV. Proton beams with highest energy near or above 60 MeV at full laser energy and similar beam profiles are also measured from low-density CD foams and flat CH foil target of micrometer-scale thickness. The ~ 700–800 nm CH/CD foils achieve the highest ion yield among the targets tested. For sub-micron thin films, the laser prepulse can expand the target and lead to complex interactions, which is simulated using coupled hydrodynamic and two-step kinetic models. Simulations suggest the presence of a micrometer-scale preplasma plateau with near-critical density and further indicate that target normal sheath acceleration, electron heating from Relativistic transparency in the preplasma plateau, and background proton reflection from carbon ion front at the rear side contribute to the resulting proton spectrum from these sub-micron thin targets at various stages. These proton beams show strong potential for radiography and for production of secondary sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of improvement of energy conversion rate from kJ PW laser to protons with electron confinement

Kilojoule-class relativistic intensity lasers can produce energetic protons with high energy conversion efficiencies in the interaction with a thin foil target. Using the national ignition facility advanced radiographic capability (NIF-ARC) laser, we demonstrated an enhancement of energy conversion from laser to protons by the effective confinement of fast electrons in the laser spot by random kicks from the self-excited field. The number of fast electrons was increased by 4.6 times by increasing the ratio of the laser spot size to the foil thickness to strengthen the confinement effect. The energy conversion efficiency from laser to protons increases approximately linearly with the enhancement of the number of fast electrons. The conversion rate for protons with energies above 8 MeV was 1.8 %. The result leads to high efficiency proton acceleration which is beneficial in applications, such as proton radiography and plasma heating in laser fusion.

Physics↗

X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids

We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.

Crystal lattices↗

Observation of d(t,n) α Neutrons Following d(d,p)t Reactions in a Deuterium Gas Cell: An Attempt to Repeat Ruhlig’s 1938 Observation of Secondary Reactions

In order to benchmark methods used to calculate reaction-in-flight fusion reactions in inertial confinement fusion and address issues related to the first claimed observation of d(t,n)α reactions in 1938, secondary d(t,n)α reactions have been observed following d(d,p)t reactions in deuterium gas. A pulsed 200-nA, 2.2-MeV deuterium beam from the Triangle Universities Nuclear Laboratory FN tandem accelerator was injected into a cylindrical multiatmosphere deuterium gas target. The incident beam traversed along the target cylinder’s 3-cm symmetry axis after its passage through a Havar entrance foil. Two different Havar foil thicknesses were used to obtain 1.5- and 0.6-MeV deuteron beams entering the deuterium cell. The cylinder’s radius was 2 cm to allow for d(d,p)t tritons emitted perpendicular to the beam to range out in the deuterium gas. The neutron emission from the cell was observed via its time of flight to a liquid scintillator placed at various angles to the beam direction, at a distance of 243 cm. Pulse-shape-discrimination techniques were used to separate neutron and gamma-ray signals seen in the liquid scintillator. The observed probability of ~2 × 10 –4 for inducing secondary d(t,n)α fusion in the gas cell per d(d,p)t reaction is consistent with theoretical expectations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variable energy X-ray fluorescence source

Here we detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8×10 6 dpm) 99 Tc β source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device produces x rays between 4 and 70 keV at a rate near 1 Hz. When the source is placed in a storage position, the external radiation is non-detectable. The design of the shielding and rotation mechanism permits use in vacuum and at liquid nitrogen temperature. The design is intended for the study of the low energy response to radiation impinging upon Ge detector surfaces. The source will be useful for understanding the detector response in large-scale Ge arrays such as MAJORANA and LEGEND.

47 OTHER INSTRUMENTATION↗

Target development using the method of High-Intensity Vibrational Powder Plating (HIVIPP) at the Center for Accelerator Target Science (CATS) at Argonne National Laboratory (ANL)

One of the primary goals of the Center for Accelerator Target Science (CATS) is to provide targets and foils in support of the ATLAS User Facility and the Low-Energy community at large. While a wide array of target production techniques are available at CATS, new methods that must be explored invariably arise. One such technique, the High-Intensity Vibrational Powder Plating (HIVIPP), was first reported in 1997 by Isao Sugai. It was developed to produce targets and stripper foils that were difficult to make by standard methods. At Argonne National Laboratory (ANL), we have successfully constructed and tested a simple system for this purpose. We have produced targets of carbon and titanium on various metal backings using the HIVIPP method. We are currently in the exciting phase of exploring the production of other elements, including isotopically enriched and radioactive material. This work is in progress and will be further detailed with specific examples.

47 OTHER INSTRUMENTATION↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of an atomic layer deposition system for deposition of alumina as a hydrogen permeation barrier

Tritium permeation into and through materials poses a critical challenge for the development of nuclear fusion reactors. Minimizing tritium permeation is essential for the safe and efficient use of available fuel supplies. In this work, we present the design, construction, and validation of custom atomic layer deposition (ALD) and deuterium permeation measurement systems aimed at developing thin-film hydrogen permeation barriers. Using the ALD system, we deposited conformal $\mathrm{Al}_{2}\mathrm{O}_{3}$ films on copper foil substrates and characterized their growth behavior, morphology, and composition. ALD growth rates of ∼1.1 Å/cycle were achieved for temperatures between 100 ∘ C and 210 ∘ C. Permeation measurements on bare and alumina coated copper foils revealed a significant reduction in deuterium flux with the addition of a ∼10 nm $\mathrm{Al}_{2}\mathrm{O}_{3}$ layer. While bare copper followed diffusion-limited transport consistent with Sievert’s law, the alumina-coated samples exhibited surface-limited, pore-mediated transport with linear pressure dependence. Arrhenius analysis showed distinct differences in activation energy for the two transport regimes, and permeation reduction factors exceeding an order of magnitude were observed. These results demonstrate the potential of ALD-grown $\mathrm{Al}_{2}\mathrm{O}_{3}$ films as effective hydrogen isotope barriers and provide a foundation for future studies on film optimization and integration into fusion-relevant components.

atomic layer deposition↗