Search NASASearch

SEARCH · Search NASA

Results for “Landsat 10”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,759 records · Page 18

Predicting Atomistic Transitions with Transformers

Accurate knowledge of the atomistic transition pathways in materials and material surfaces is crucial for many material science problems. However, conventional simulation techniques used to find these transitions are extremely computationally intensive. Even with large-scale, accelerated material simulations, the computational cost constrains the applicable domain in practice. Machine learning models, with the potential to learn the complex emergent behaviors governing atomistic transitions as a fast surrogate model, have great promise to predict transitions with a vastly reduced computational cost. Here, we demonstrate how transformers can be trained to predict atomistic transitions in nano-clusters. We show how we evaluate physical validity of the predictions and how a multitude of additional, different microstates can be generated by slightly varying the data provided to the model.

36 MATERIALS SCIENCE

Challenge of Fielding Experiments at the Annular Core Research Reactor

Conference is the annual Test, Research &Training Reactors (TRTR) meeting. Typically attended by dozens of research reactor operators, educators, trainers, maintenance & service contractors Also, members of the Nuclear Regulatory Commission (NRC) attend. Presentation highlights ACRRs capability and the process used to submit and approve experimental activities. This presentation is adapted from my previous presentation to the Material Test and Research conference, SAND2025-1775526.

Martin, Lonnie E. [Sandia National Laboratories (S

Fast lithium ion diffusion in brownmillerite Li x Sr 2 Co 2 O 5

Transition metal oxides not only exhibits novel magnetic properties but also provides outstanding ionic transports. Ionic conductors have great potential for interesting tunable physical properties via ionic liquid gating and novel energy storage applications such as all-solid-state lithium batteries. In particular, low migration barriers and high hopping attempt frequency are the keys to achieve fast ion diffusion in solids. Taking advantage of the oxygen-vacancy channel in Li x Sr 2 Co 2 O 5 , we show that migration barriers of lithium ion are as small as 0.28–0.17 eV depending on the lithium concentration rates. Our first-principles calculation also investigated hopping attempt frequency and concluded the room temperature ionic diffusivity and ion conductivity are high as 10 −7 –10 −6 cm 2 s −1 and 10 −3 –10 −2 Scm −1 , respectively, which outperform most of perovskite-type, garnet-type, and sulfide Li-ion solid-state electrolytes. This work proves Li x Sr 2 Co 2 O 5 as a promising super-ionic conductor.

Crystallographic defects

Requirements Description of VARPOW

This report presents the modeling and simulation capabilities of Argonne National Laboratory’s VARPOW code that is used in present reactor analysis activities. These capabilities will then be used to establish the set of VARPOW verification tasks necessary to verify VARPOW for usage on commercial projects. A similar approach was taken for the PERSENT, REBUS and DIF3D software packages.

Ramey, Kyle [Argonne National Laboratory (ANL), Ar

Ductless Heat Pump Program

The Verde Ductless Heat Pump (DHP) Program expanded access to high-efficiency electric heating and cooling technologies for households in priority communities within the Portland Metro area. Funded by the U.S. Department of Energy’s Building Technologies Office (DE-EE0010132), the program combined residential ductless heat pump deployment with community-based outreach, participant support, contractor partnerships, and system development to improve program delivery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Challenges for Megawatt-Scale Artificial Intelligence Rack Infrastructure

As artificial intelligence (AI) computing densities continue to increase, industry is pursuing megawatt-scale rack architectures that require tightly coordinated advances in electrical power delivery, thermal management, operations, and infrastructure integration. This document summarizes the primary technical challenges for achieving this target.

Nawaz, Kashif [ORNL] (ORCID:0000000251612491)

Characterization of NBCMA—A DAPO Precursor

As part of our investigation into the process optimization of 2,6-diaminopyrazine-1-oxide (DAPO), small-scale sensitivity testing (impact, friction, and ESD) was conducted on the precursor, N-nitroso-bis(cyanomethyl)amine (NBCMA). NBCMA exhibited moderate sensitivity to friction, whereas no sensitivity to impact or spark was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Crustal Deformation and Gravitational Effects From Dynamic Ocean Mass Redistribution Impact Projected Sea‐Level Change

As the climate warms, associated changes in ocean dynamics will redistribute sea‐water mass within the ocean, contributing to relative sea‐level change. This mass redistribution will cause additional sea‐level changes due to gravitational self‐attraction, deformation of the solid Earth, and shifts in the Earth's rotation axis (GRD), which are not incorporated in sea‐level projections. Using CMIP6 climate model output, we quantify relative sea‐level changes induced by GRD from ocean‐dynamic mass loading through 2100. These effects act to amplify projected ocean‐dynamic sea‐level patterns, causing sea‐level rise in coastal regions, particularly along wide continental shelves and at high latitudes. On average, the magnitude of such GRD‐induced sea‐level change is equivalent to ∼15% of the signal due to dynamic ocean mass redistribution. Although our results show substantial inter‐model spread, they reveal that GRD‐induced relative sea‐level changes from ocean mass redistribution represent a non‐negligible component of regional sea‐level change and should be considered in projections.

58 GEOSCIENCES

India Power Sector Reliability Analysis [Slides]

The objective of the study is to assess pathways for India to achieve its 2070 power sector goals reliably and cost-effectively by considering various supply- and demand-side factors to support planning by national stakeholders including the Central Electricity Authority (CEA).

08 HYDROGEN

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN