Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Grid-Assisted Direct-Current Magnetron Sputtering of Titanium: Plasma Discharge Diagnostics

Grid-assisted magnetron sputtering is attractive for the deposition of ultrathick Be coatings in inertial confinement fusion (ICF) applications because it offers improved control over the plasma. Here, we investigate the plasma discharge characteristics of grid-assisted direct current magnetron sputtering with Ti as a surrogate sputter target material instead of Be. We map the magnetic field of our magnetron source assembly, study the current-voltage characteristics of both the source and the substrate, and measure the energy distributions of ions bombarding the film surface during growth. The results reveal a slightly asymmetric magnetic field of the magnetron source array and strong dependencies of the plasma discharge characteristics on both the grid and the substrate voltages. Positive grid voltage increases both target and substrate currents, increases the plasma potential, and broadens the energy distributions of ions bombarding the substrate. Grid biasing effects on the plasma discharge characteristics and substrate current can be attributed to corresponding changes to the plasma potential, while substrate biasing effects are more complex and nonlinear. Furthermore, these results demonstrate that grid-assisted deposition offers additional flexibility in controlling the deposition process for tuning properties of ultrathick films for ICF applications.

ICF targets↗

A Quantitative Failure Analysis on Capacity Fade in Rechargeable Lithium Metal Cells

Rechargeable lithium battery (RLB) technology is transforming portable devices, vehicle electrification, and grid modernization. To make RLB durable, reliable and safe, conducting failure mode and effect analysis (FMEA) to identify failure mechanism under the operating conditions is very desirable. However, this ability is often overlooked or even lacking. The failure analysis (FA) is often conducted by laboratory testing and postmortem analysis, and the knowledge typically empirical. Here we present a quantitative approach for FMEA that can reveal how failure modes and effects reduce the capacity of a RLB. This approach is based on the state of the battery for FMEA, contrary to the conventional approach based on operating or testing conditions. The key aspect of this FMEA method is to convert the experimental results to a state-of-charge (SOC)-based analytic methodology. Such a conversion can separate the thermodynamic and kinetic attributes of capacity fade based on compositional correspondence in the electrode, so the loss and the decreased utilization of the active materials can be determined respectively.

25 ENERGY STORAGE↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling detonation with CartaBlanca simulations

The accurate modeling of high explosive (HE) detonation and the con- sequent large solid deformation, failure, plastic flow, porosity growth, and shock wave propagation is important because simulations can capture spatial and temporal features that experimental diagnostics cannot capture. However, the simulation of the explosive event poses challenges to a computational scientist. These include the accurate modeling of ductile damage, crack formation, plastic deformation, as well as physical and nu- merical instabilities. The material response can be history-dependent and subject to large material deformation. Our research simulates the impact of a high explosive (Detasheet) onto a tantulum metal plate. We performed the simulations using CartaBlanca at different mesh resolutions. We decided the study would be impactful if we perform the simulations with the Material Point Method. Differences were observed at the different mesh resolutions in velocity and nodal stress magnitude, so increased mesh resolutions may be required. In addition, the Discontinuous Galerkin method would be needed to account for the large gas expansion.

97 MATHEMATICS AND COMPUTING↗

Impact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis

Increased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3σ detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 × 1017 n/cm2 neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 ± 610 K to 6900 ± 810 K and from 15,800 ± 400 K to 7200 ± 800 K, respectively, for exposure to the 1.7 × 1017 n/cm2 fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha–Boltzmann method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A novel method to measure ion density in ICF experiments using x-ray spectroscopy of cylindrical tracers

The indirect drive approach to inertial confinement fusion has undergone important advances in the past few years. Improvements in temperature and density diagnostic methods are leading to more accurate measurements of the plasma conditions inside the Hohlraum and therefore to more efficient experimental designs. The implementation of dot spectroscopy has proven to be a versatile approach to extracting space- and time-dependent electron temperatures. In this method, a microdot of a mid-Z material is placed inside the Hohlraum and its K-shell emission spectrum is used to determine the plasma temperature. However, radiation transport of optically thick lines acting within the cylindrical dot geometry influences the outgoing spectral distribution in a manner that depends on the viewing angle. This angular dependence has recently been studied in the high energy density regime at the OMEGA laser facility, which allowed us to design and benchmark appropriate radiative transfer models that can replicate these geometric effects. By combining these models with the measurements from the dot spectroscopy experiments at the National Ignition Facility, we demonstrate here a novel technique that exploits the transport effects to obtain time-resolved measurements of the ion density of the tracer dots, without the need for additional diagnostics. Furthermore, we find excellent agreement between experiment and simulation, opening the possibility of using these geometric effects as a density diagnostic in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low Energy Muon Beam Diagnostics: Scintillating Fiber Profile Monitor

The MeV Test Area (MTA) houses the 400 MeV H- Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam’s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Effects and mitigation of pulsed power radiation on optical fiber velocimetry

We report optical fiber diagnostics are extensively used in pulsed power experiments, such as the Sandia Z machine. However, radiation produced in a pulsed power environment can significantly affect these measurements. Catastrophic fiber darkening may be mitigated with shielding, but no flexible material can stop all radiation produced by the machine and/or target. Radiation-induced refractive index modulations are particularly challenging for optical interferometry. Several approaches for radiation-tolerant photonic Doppler velocimetry are discussed here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

High-Field Quantum Diamond Magnetometers for Fusion Diagnostics (Final Technical Report)

Summary of research performed to enable all-optical quantum diamond magnetometers for fusion diagnostics, including: the physical mechanisms enabling all-optical photoluminescence contrast as a function of magnetic field magnitude and direction for dense ensembles of nitrogen vacancy (NV) centers in diamond; the characterization and optimization of NV-diamond material; and related investigations and student training.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tunable phase-change metasurfaces coupled with mid-infrared molecular vibrations

Chiral optical metasurfaces have emerged as a promising platform in coupling with molecular vibrational fingerprints through the enhanced light-matter interaction under different circularly polarized light illumination. Here, this work reports the mode coupling between the mid-infrared phonon vibrations of polymethyl methacrylate (PMMA) molecules and the thermally tunable chiral metasurfaces based on the phase-change material Ge₂Sb₂Te₅ (GST-225). Phase-change chiral metasurfaces with high circular dichroism (CD) in absorption and tunable plasmonic resonance in the frequency range of 48–56 THz are demonstrated, which covers the phonon vibrational frequency of PMMA molecules at 52 THz. The mode splitting features are observed in the absorption and CD spectra when the metasurface resonance is tuned across the phonon vibrational frequency of PMMA molecules during the phase transition of GST-225. The underlying mechanism of molecule-metasurface coupling is further revealed by studying the electric field and power loss density distributions of the phonon–plasmon coupled modes under both left-handed and right-handed circularly polarized (LCP and RCP) light. The demonstrated results show the potential of dynamically tunable chiral metasurfaces for the applications in label-free molecular sensing, biomedical diagnostics, thermal imaging, and mid-infrared photonics.

Tang, Haotian [Missouri Univ. of Science and Techn↗

Low Energy Muon Beam Diagnostics - Scintillating Fiber Profile Monitor (SFPM)

The MeV Test Area (MTA) houses the 400 MeV H^− Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

Noninvasive Detection, Tracking, and Characterization of Aerogel Implants Using Diagnostic Ultrasound

Medical implants are routinely tracked and monitored using different techniques, such as MRI, X-ray, and ultrasound. Due to the need for ionizing radiation, the two former methods pose a significant risk to tissue. Ultrasound imaging, however, is non-invasive and presents no known risk to human tissue. Aerogels are an emerging material with great potential in biomedical implants. While qualitative observation of ultrasound images by experts can already provide a lot of information about the implants and the surrounding structures, this paper describes the development and study of two simple B-Mode image analysis techniques based on attenuation measurements and echogenicity comparisons, which can further enhance the study of the biological tissues and implants, especially of different types of biocompatible aerogels.

36 MATERIALS SCIENCE↗

Radioimaging for real-time tracking of high-voltage breakdown

Development of a radioimaging diagnostic for high-voltage component reliability testing and electrical breakdown computational model validation is described. Radioimaging has its roots in radio astronomy, where aperture synthesis (also known as synthesis imaging) has been utilized for decades to image radio sources far from Earth. Radioimaging as described herein, in contrast, seeks to image radio sources in close proximity to its receivers (i.e., in a laboratory environment). Here it is shown that corona discharge, a non-destructive precursor to catastrophic (thermal) arc discharge, electromagnetically radiates strongly within a 250 kHz – 2.5 GHz bandwidth, and is readily detected and located by postprocessing the received radio signals. The ability of radioimaging to detect both corona and arc discharge (grouped together herein as high voltage breakdown or HVB) makes it a valuable tool for 100% HVB detection in materials, components, and devices, and has the ability to indicate electrical weakness (via corona detection) prior to a destructive arc discharge event. Radioimaging enables HVB to be located both internal and external to dielectric components under test in near-real-time, with multiple and/or extended HVB events located simultaneously. In contrast, existing non-destructive diagnostics (at the time of this writing) either indicate electrical breakdown without resolving failure locations (e.g., current, voltage, and chemical measurements), locate external HVB (e.g., high-speed optical and ultraviolet (UV) measurements or photography), or locate both external and internal HVB but with low fidelity (e.g., a single HVB source can be located by existing time-of-arrival (TOA) UHF or acoustic emissions). Radioimaging instead creates a sequence of high-fidelity images similar to an optical high-speed camera but at radiofrequencies (RF), and is not limited to two-dimensions. Moreover, radioimaging has already served one internal and two external industry customers, the results of which are detailed in this report. The radioimaging results described herein were part of a three-year effort funded by the Sandia Lab Directed Research and Development (LDRD) program within the Radiation, Electromagnetic, High Energy Density Science (REHEDS) investment area.

47 OTHER INSTRUMENTATION↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗